The INF200 non-contact infrared thermometer
provides a faster, easier way to take diagnostic
temperature measurements. Monitor the
temperature of transformers, circuit breaker panels,
motors and bearings, supply and return registers,
ducts, inlet/outlet steam lines, furnace flues and
many other surfaces. use the INF200 when
diagnosing temperature problems to save time and
reduce the risk of burns and injuries.
The INF200
has the following features:
•Laser targeting
•Nine measurement memory
•Measures MIN/MAX/∆T/AVG temperatures
•Switchable ˚F or ˚C readings
• Temperature range: 0˚ to +788˚F (-20 to +420˚C)
•Distance spot ratio of 8 to 1
•Emissivity: adjustable 0.30 to 1.0
•Built-in barrel sight
• Backlight
•User programmable alarm
•Quick and simple operation
•Protective high-impact case included
• One year limited warranty
Copyright © 2004 UEi Specifications are subject to change without notice. L504 10/04
INF200 • Infrared Thermometer
Specifications
Distributed By:
1-800-547-5740 • Fax: (503) 643-6322
Service: (800) 308-7709
IN CANADA
Vancouver: Phone: (604) 278-4511 • Fax: (604) 278-8299
Toronto: Phone: (905) 238-6760 • Fax: (905) 238-5117
IN EUROPE
Phone: +44 1707 375550 • Fax: +44 1707 393277
Te m p e rature ra n g e 0˚ to 788˚F (-20˚ to 420˚C)
Accura cy ±2% of rdg. or ±3˚F (±2˚C) whichever is greater @
73˚ ± 9˚F (23˚ ± 5˚C) ambient operating temperature and
a known blackbody emissivity
Re p ea t ab i li ty ±1% of rdg or ±2˚F (1˚C) whichever is greater
Response time 500 m sec. (95% response)
Spectral response 7 - 18 microns nominal thermopile detector
Memory 9 measurements / 5 functions each
laser* (class 2 output) Yes
E m i s s i v i ty.30 - 1.00 digitally adjustable
Te m p e rature display ˚F or ˚C (selectable) 3 digit LC D
Display resolution 1˚F or 1˚C in all modes
Ambient operating rage 32˚ to 120˚F (0˚ to 50˚C)
Relative humidity 10 - 95% RH noncondensing @ up to 85˚F (30˚C)
Storage tempera t ure -13˚ to 158˚F (-25˚ to 70˚C) without battery
Pow e r 9V alkaline battery
Battery life (alkaline) 50 hours (backlight not used)
16 hours laser used 50%, backlight used 50 % **
Dimens i o n s 5.4” x 1.6” x 7.7” (137 mm x 41 mm x 196 mm)
We i g ht 9.5 oz. (270 gm)
Access o r i es Manual and water resistant hard ca s e
Distance spotra t i o 8 to 1
*Laser is offset 0.5” (1-2 cm) below center of target spot
* * B a t t e rylife will vary based on backlight and laser use