UV SunUVStatio User manual

User’s Guide
Maintaining the SunUVStation
Battery Replacement
• The SunUVStation is designed for a one year battery life. It is
recommended that the batteries be replaced once a year even if the
unit is still operating to insure continuous operation
• The unit will not operate when the batteries are low. If the needle
does not move during a period of sun exposure, replace the
batteries. If you suspect the batteries are low and the unit is not
responding, block the sunlight with your hand placed a short
distance above the white detector area. The needle should move
down if the batteries have sufficient charge. Replace the batteries
indoors so that the unit does not inadvertently recalibrate.
Keep the Detector Area Clean
•To maintain accuracy, it is important to keep the white circular
detector area clean of dust, debris and water film. Wipe it gently with
asoft cloth to remove debris. Water or common household cleaners
such as window cleaner may also be used.
•CAUTION:the white circular window of the detector area is delicate.
Clean it with care, do not press hard. Avoid contact with sharp or
heavy objects that may damage it.
Important Safety Precautions
UV Meter Inc. does not warrant or represent that use of the
SunUVStation™ and the “UV Protection Guidelines” chart included with
the product will prevent sunburn, wrinkles, skin cancer, cataracts,
immune suppression or any other risks associated with UV radiation
exposure. Many factors can contribute to an individual’ s response to UV
and the total UV to which they are exposed, including his/her skin type,
use of sunscreen, use of certain medications, ingestion of alcohol,
variable weather conditions, reflected UV, extreme temperature and/or
humidity , and other factors, known and unknown. The SunUVStation is a
monitoring device which, when used in conjunction with good judgment
and appropriate protective measures, may lower the probability of harm
from ultraviolet (UV) exposure. UV Meter Inc.shall have no liability to any
pur chaser or user of this product except for liability to replace or repair
the product in the event of malfunction in accordance with UV Meter Inc’s
limited product warranty.
This product is designed to measure only solar radiation, and should not
be used for monitoring UV from artificial sour ces.
Limited Warranty
This warranty is expressly extended and limited to the original
“consumer” purchaser and warrants the SunUVStation™ to be free from
defects in materials and workmanship, under normal use, for a period of
30 days from the date of original purchase. This warranty shall be
governed by and interpreted in accordance with the Laws of the United
States of America. This limited warranty does not cover any failure to
function properly due to misuse, such as water immersion or severe
mechanical shock. In the unlikely event that your product does not
operate as specified, please return it to UV Meter Inc.
UV Meter Inc
26101 Harbour Pointe Dr. N
Harrison Township, MI 48045
USA
586-790-8025
This User's Guide ©2005

No Protection
Required
You Can Safely
Stay Outside!
Protection Required
Seek shade during
midday hours!
Slip on a shirt, slop on sunscreen
and slap on a hat!
Extra Protection
Avoid being outside during
midday hours!
Make sure you seek shade!
Shirt, sunscreen and hat
are a must!
SunUVStation™: Background Information About the UV Index
The SunUVStation displays a number called the “UV Index.” The UV
Index is a standardized scale indicating the intensity of the sun's UV
radiation that affects human skin. (UV can also damage eyes) The UV
intensity varies from one place to another, and in the same location it
varies throughout the day and as the seasons change. The variations are
caused by the sun’s changing position in the sky, clouds, the altitude, and
other factors, so each location has its own range of UV index values from
dawn to sundown. The UV Index is used in the United States, Canada,
Australia, New Zealand and many other countries by agencies such as the
US Environmental Protection Agency and Environment Canada.
The higher the UV Index, the more care you should take when working,
playing or exercising outdoors. For most places on Earth the Index will
read between 1 and 15, but some high altitude places such as the Mauna
Loa Observatory in Hawaii have measured a UV Index of 20. The UV
Index can make a large difference in the amount of time you can spend in
the sun before sunburn. For example, if you are very fair skinned and are
not using sunscreen or wearing protective clothing, you could spend an
hour or more in the sun without sunburn on a low UV index day (1 to 2),
but have less than 10 minutes before sunburn on a day with a UV Index
of 10. The UV Index stated in newspapers and broadcast media weather
reports in the USA is a forecast from the National W eather Service of the
highest reading for the day for a general area. The SunUVStation
provides a continuous actual measurement of the UV Index for the
specific location it is in. In addition to the numbers, UV Index ranges are
described in categories and with colors:
Protecting Skin from Too Much UV
The amount of UV that skin can tolerate before it burns varies greatly
from one person to another. But even if it were possible to stop UV
exposure just short of sunburn, this is not advised. Tanned skin is
considered damaged and tanning is the skin’ s attempt to prevent further
damage. The World Health Organization (WHO) recommends that any
time the UV Index is greater than 2 you should take precautions to limit
sun exposure with sunblock, a hat and shirt, and limit time in the sun as
the index moves to higher values. The WHO has established general
guidelines for protective measures and sun avoidance based on the UV
Index. These are shown in the chart below .
Included with the SunUVStation is a larger copy of this chart that can be
posted in a convenient place for reference. For more information on the
UV Index and how to take precautions against overexposure, visit the
following websites on the Internet:
The US EPA’s site for the “Sunwise” UV awareness program:
http://www.epa.gov/sunwise/
The World Health Organization site: http://www.who.int/uv/en/
Acolor pamphlet from WHO on the UV Index:
http://www .who.int/uv/publications/en/GlobalUVI.pdf
Directions for Use (Batteries already included)
Set Up
Batteries
• 3 AA batteries are required to power the SunUVStation
• Remove the two screws in the battery compartment cover. Place the
batteries in the compartment in the orientation shown in the graphic.
Install the batteries in the shade so the unit does not inadvertently
recalibrate.
•CAUTION:be sure that the +/- orientation is correct. If the batteries
are placed in the unit incorrectly it may be damaged.
•After the batteries are inserted, the pointer in the unit will move all the
way to the right and then all the way to the left (0 UV). If there is UV
present, it will then move to the
correct UV Index.
•Replace the battery compartment
cover. Snug the screws but do not
overtighten.
•CAUTION: Do not damage the seal
around the battery compartment cover
to insure that water cannot enter .
Using the SunUVStation
The SunUVStation should be used in an outdoor sunny location, either
placed on its stand, hung by a nail or screw mounted in a post or fence,
or attached to fence, pole or other structure using the nylon strap. Do
leave out in rain.
• The ideal location for the unit is free of shade during all or most of the
day. Mounting it on the outside wall of a house or at a low point on a
solid fence could significantly limit its ability to measure the UV
during much of the day.
• Do not use the unit indoors next to a window or under a skylight, or
with any other transparent material between the detector area and the
sunlight. Window glass, plexiglass, automobile glass, plastic sheet
and many other transparent materials can block UV and make the
measurement inaccurate.
• When it is mounted, it is important that the circular white detector
area on the top of the instrument be pointed straight up so that the
measurements will be correct for any position of the sun.
• The white circular detector area must be kept clean for accurate
readings (see below – Maintaining the SunUVStation.) Keep this in
mind when selecting a location. If it is difficult to access -- for
example, located in a ver y high position -- it will be difficult to check
the cleanliness of the detector area and clean it if necessary.
• Also, consider if the location will place the unit in the path of sports
balls or other objects that may strike it and cause damage.
Using the Stand
• Insert the stand into the holes in the
bottom of the unit by pressing the two legs
slightly outwards. Push the stand in until it
stops.
• The unit can be placed on any level surface
in a location that is exposed to the sun as
much of the day as possible. If it is
extremely windy, you may wish to place a
weight on the stand.
Using a Hanger
• The SunUVStation can be hung from the
keyhole-shaped slot in the back using a
screw, nail or hook of the appropriate size.
• The unit should rest against the structure
holding the hanger so that it does not sway
or rotate excessively in the wind.
• Be sure to locate the white circular detector
area so that it is level and exposed to the
sun as much of the day as possible.
Using the Nylon Strap and Buckle
•The SunUVStation can be attached to a
pole, fence or other structure using the
nylon strap and buckle
•Feed the strap through the two slots in the
back of the unit
•When strapping to an object, snug the
strap so that it is firm. CAUTION : do not
apply excessive force tightening the strap.
•Be sure to locate the white circular detector area so that it is
level and exposed to the sun as much of the day as possible.
low = 1-2 = green
moderate = 3-5 = yellow
high = 6-7 = orange
very high = 8-10 = red
extreme = 11 and higher = violet
Popular Test Equipment manuals by other brands

Reed Instruments
Reed Instruments R5600 instruction manual

W Box Technologies
W Box Technologies 0E-TELBSET user manual

Chauvin Arnoux
Chauvin Arnoux 10141 Getting started guide

Agilent Technologies
Agilent Technologies 3000 Series User's and service guide

GeoInsight
GeoInsight HydraSleeve Standard operating procedure

gs yuasa
gs yuasa GYT117 user guide