V-Tec DT591 User manual

2 -Wire Intercom System
DT591/592 User Manual
DT-ENG-591/592-V1 100S503
DT591 DT592

CONTENTS
1.Parts and Functions............................................................................................. 1
2.Terminal Descriptions .......................................................................................... 1
3.Specications ...................................................................................................... 2
4.Mounting.............................................................................................................. 2
4.1 Mounting Without Rainy Cover...................................................................... 2
4.2 Mounting With Rainy Cover........................................................................... 3
4.3 Placing Name Label ...................................................................................... 3
4.4 Adjusting Camera Angle ................................................................................ 4
5.System Wiring and Connections ......................................................................... 4
5.1 Basic Connection........................................................................................... 4
5.2 Electric Lock Connection............................................................................... 5
5.2.1 Door Lock Controlled with Internal Power ............................................ 5
5.2.2 Door Lock Controlled with Dry Contact ................................................ 5
5.2.3 How to setup the unlock parameter in Monitor...................................... 6
5.3 Multi Doorstations Connection....................................................................... 7
5.4 Multi Monitors Connection............................................................................. 8
5.4.1 Basic IN-OUT Wiring Mode ................................................................. 8
5.4.2 With DBC-4 Wiring Mode .................................................................... 9
6.Setup ................................................................................................................... 10
6.1 DIP Switches Settings of Doorstation............................................................ 10
6.2 DIP Switches Settings of Monitor .................................................................. 10
6.3 Notices........................................................................................................... 12
7.Cables Requirements .......................................................................................... 13

-1-
1.Parts and Functions
Rainy Cover
Camera Lens
Night View LED
Speaker
Nameplate
Call Button
Microphone
90 mm
176 mm
23 mm
2.Terminal Descriptions
BUS
PL
S1+ S2+ S-
1 2
ON
1 2
ON
MIC adjustment
Lock Control Jumper
Doorstation Code DIP
Main Connect Port
1 2 3
SPK adjustment
Note: DT592 has two call buttons.

-2-
•Lock Control Jumper: To select the lock type: see 5.2.1 , 5.2.2
•Doorstation Code DIP: Total 4 doorstations can be supported,see 6.1
•Main Connect Port: To connect the bus line and the electronic locks.
•BUS: Connect to the bus line, no polarity.
•PL: External lock power input, connect to the power positive(power +).
•S1+, S2+: Lock power(+) output, to connect 2 locks.
•S-: Lock power(-) output, connect to the power(-) input of locks(only when using the camera to power the locks,
if using the external power supply for the locks, the S- will not be connected).
3.Specications
Lock Power supply: 12Vdc, 300mA(Internal Power)
Power Consumtion: 1W in standby, 12W in working
NO, COM dry contact: Max. 48V dc 1.5A
Unlocking time: 1 to 9 seconds, set by Monitor
Working temperature: -10ºC ~ 45ºC
4.Mounting
4.1 Mounting Without Rainy Cover
160-165cm
1
2
1 2 3 4

-3-
4.2 Mounting With Rainy Cover
160-165cm
1
2
1 2 3 4
4.3 Placing Name Label
Move the plastic cover away to open the transparent name label cover, insert a name paper, then put the plastic
cover back to the panel.
name label
1 2
ON

-4-
4.4 Adjusting Camera Angle
5.1 Basic Connection
use a screwdriver to loosen the screw and then adjust the angle
of the camera ,then x the screw.
5.System Wiring and Connections
1 2
ON
-
+
L1 L2 PL S1+ S2+ S-
AC~
monitor
DPS PS4

-5-
5.2 Electric Lock Connection
5.2.1 Door Lock Controlled with Internal Power
connect one lock connect two locks
Note:
1. Electronic lock of Power-on-to-unlock type should be used.
2. The door lock is limited to 12V, and holding current must be less than 250mA.
3. The door lock control is not timed from Exit Button(EB)
4. The Unlock Mode Parameter of Monitro must be set to 0 (by default)
12
ON
1 2 3
-
+
BUS PL S1+ S2+ S-
-
+
Jumper position in 1-2
lock #2
lock #1
EB
EB
12
ON
1 2 3
-
+
BUS PL S1+ S2+ S-
Jumper position in 1-2
EB
5.2.2 Door Lock Controlled with Dry Contact
Note:
1. The external power supply must be used according to the lock
2. The inside relay contact is restricted to AC or DC 24V/3A
3. The jumper must be taken off before connecting
4. Setup the Unlock Mode of Monitor for different lock types
•Power-on-to-unlock type:Unlock Mode=0 (by default)
•Power-off-to-unlock type:Unlock Mode=1

-6-
12
ON
1 2 3
-
-
+
+
BUS PL S1+ S2+ S-
Take off the Jumper
Take off the Jumper
12
ON
1 2 3
-
-
+
+
BUS PL S1+ S2+ S-
Power supply Power supply
-
+
lock #2
lock #1
connect one lock connect two locks
5.2.3 How to setup the unlock parameter in Monitor
monitor
intercom
setup
exit
Outdoor Tone -- 01
Intercom Tone -- 05
Monitor Time -- 1min
Advanced Set...
Auto Record -- OFF
Exit
0
* * *
Password:
Slave Addr Set -- 0
Guard Unit Set -- 0
Date/Time Set...
Other Settings...
Information...
Exit
Hardware ver 0302
Software ver 0168
Voltage 22.4V
Manufacture 00.0T
Restore to default
Exit
Unlock Time 1
Unlock Mode 0
Exit
1.Press MENU button two
times to enter the MAIN MENU
page,then press setup item
2.Select Advanced Set...item and
press MENU button to enter,a
password will be asked
4.Select Information...item and
press MENU button to enter next
page.
Note:
1.must connect DT591/592 completely before setting
2.the parameter will be saved in doorstation automatically,so you need only set on one monitor
5.Press UNLOCK button
and hold for 2s
6.Use / to select the item,
use / to change the value
of the item.select Exit item,press
MENU button to save the settings
automatically.
3.The default password is ****
press / button to increase/
decrease the value,Press /
button to select the location,after
finishing,press MENU button to
enter next step.

-7-
5.3 Multi Doorstations Connection
85~260VAC
DPS PS5
monitors
12
ON
L1 L2 PL S1+ S2+ S-
12
ON
L1 L2 PL S1+ S2+ S-
12
ON
L1 L2 PL S1+ S2+ S-
12
ON
L1 L2 PL S1+ S2+ S-
1 2
ON
1 2
ON
1 2
ON
1 2
ON
1# Camera
ID=00
ID=10
ID=01ID=11
2# Camera3# Camera4# Camera
DBC4
A B C D
BUS

-8-
5.4.1 Basic IN-OUT Wiring Mode
5.4 Multi Monitors Connection
ID=00
1 2
ON
Code=0, DIP-6=off
Code=14, DIP-6=off
Code=15, DIP-6=on
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
85~260AC
DPS PS5
monitor
monitor
monitor

-9-
5.4.2 With DBC-4 Wiring Mode
HI
HI
monitor
monitor
monitor
monitor
monitor
monitor
monitor
monitor
DBC-4
A B C D
IN
OUT
DBC-4
A B C D
IN
OUT
85~260AC
DPS PS5
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
Code=15, DIP-6=on
Code=13, DIP-6=on
Code=3, DIP-6=on
Code=1, DIP-6=on
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
Code=14, DIP-6=on
Code=12, DIP-6=on
Code=2, DIP-6=on
Code=0, DIP-6=on
ID=00
1 2
ON

-10-
6.Setup
6.2 DIP Switches Settings of Monitor
6.1 DIP Switches Settings of Doorstation
Total 2 bits on the DIP switches can be congured.The switches can be modied etther before or after installation.
Bit state Descriptions
Default setting, ID = 0(00), set to the rst Door Station.
ID = 1(10), set to the second Door Station.
ID = 2(01), set to the third Door Station.
ID = 3(11), set to the fourth Door Station.
12
ON
1 2
ON
1 2
ON
1 2
ON
There are 6 bit switches in total. The DIP switches are used to congure the User Code for each Monitor.
ON(1)
=
OFF(0)
=
ON
ON
Bit-6 is line terminal switch, which have to be set to ON if the Monitor is in the end of the line(bus), otherwise set to OFF.
Bit state Setting Bit state Setting
The monitor is
not at the end
of the bus.
The monitor is
at the end of
the bus.
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON

-11-
Bit state User Code Bit state User Code Bit state User Code
Code=0 Code=11 Code=22
1 2 3 4 5 6
ON
Code=1
1 2 3 4 5 6
ON
Code=12
1 2 3 4 5 6
ON
Code=23
1 2 3 4 5 6
ON
Code=2
1 2 3 4 5 6
ON
Code=13
1 2 3 4 5 6
ON
Code=24
1 2 3 4 5 6
ON
Code=3
1 2 3 4 5 6
ON
Code=14
1 2 3 4 5 6
ON
Code=25
1 2 3 4 5 6
ON
Code=4
1 2 3 4 5 6
ON
Code=15
1 2 3 4 5 6
ON
Code=26
1 2 3 4 5 6
ON
Code=5
1 2 3 4 5 6
ON
Code=16
1 2 3 4 5 6
ON
Code=27
1 2 3 4 5 6
ON
Code=6
1 2 3 4 5 6
ON
Code=17
1 2 3 4 5 6
ON
Code=28
1 2 3 4 5 6
ON
Code=7
1 2 3 4 5 6
ON
Code=18
1 2 3 4 5 6
ON
Code=29
1 2 3 4 5 6
ON
Code=8
1 2 3 4 5 6
ON
Code=19
1 2 3 4 5 6
ON
Code=30
1 2 3 4 5 6
ON
Code=9
1 2 3 4 5 6
ON
Code=20
1 2 3 4 5 6
ON
Code=31
1 2 3 4 5 6
ON
Code=10
1 2 3 4 5 6
ON
Code=21
Note:Monitors response button A must set the user code from 0 to 15.and
button B set the user code from 16 to 31.
A
B
A
Bit-1 to Bit-5 are used to User Code setting. The value is from 0 to 31, which have 32 different codes .
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON

-12-
6.3 Notices
Name Discription Useage
PS5-24V Power supply,85~260Vac input,24Vdc/3A output,10
DIN modeules
Connect with multi doorstations or multi
monitors(up to 2 or above)
PS4-24V Power supply,85~260Vac input,24Vdc/1A output,for
basic kit only,4 DIN modules
Connect with one doorstation and one
monitor(DT16 can be connected two)

-13-
7.Cables Requirements
The maximum distance of the wiring is limited in the DT system. Using different cables may also effect the maximum distance
the system can reach.
When Monitor quantity < 20
Cable Usage A B C
Twisted cable 2x0.75 mm260 60 30
Twisted cable 2x1 mm280 80 40
When Monitor quantity > 20
Cable Usage A B C
Twisted cable 2x1 mm270 30 20
Twisted cable 2x1.5 mm270 50 30
The farest monitor
B
A
C
DPS PS5
DBC/DBC-4
monitor
monitor
monitor
with two or four monitors

-14-
The design and specications can be changed without notice to the user. Right to
interpret and copyright of this manual are preserved.
Other manuals for DT591
1
This manual suits for next models
1
Table of contents
Other V-Tec Intercom System manuals

V-Tec
V-Tec DT-DJ5A User manual

V-Tec
V-Tec DT-DJ4 User manual

V-Tec
V-Tec DT16D3 User manual

V-Tec
V-Tec 2Easy DMR18s User manual

V-Tec
V-Tec DT31M User manual

V-Tec
V-Tec DT24 Series User manual

V-Tec
V-Tec C5-AT25/D4 User manual

V-Tec
V-Tec Livila VT27 User manual

V-Tec
V-Tec DJ4A User manual

V-Tec
V-Tec DT591 User manual

V-Tec
V-Tec 27SDTD7-V1 User manual

V-Tec
V-Tec 2-WIRE User manual

V-Tec
V-Tec DMR11 Series User manual

V-Tec
V-Tec AT27TD7 User manual

V-Tec
V-Tec 27TD7-V1 User manual

V-Tec
V-Tec DMR11 User manual

V-Tec
V-Tec DT37MG User manual

V-Tec
V-Tec VT596/KP User manual

V-Tec
V-Tec VIDEO DOOR PHONE SYSTEM User manual

V-Tec
V-Tec AT16/C5 User manual