V-Tec DT596/KP User manual

2 -Wire Intercom System
DT596(F)KP User Manual
DT596/KP DT596F/KP
DT-ENG-596(F)KP-V2 110S714
1
4 5 6
98
0 #
7
*
2 3 1
4 5 6
98
0 #
7
*
2 3

Contents
1.Parts and Functions............................................................................................. 1
2.Terminal Descriptions .......................................................................................... 1
3.Door Station Mounting ......................................................................................... 2
4.System Wiring and Connections ......................................................................... 4
5.DIP Switches Setting ........................................................................................... 11
6. Functions Setting Up .......................................................................................... 12
7.Unlock Operations ............................................................................................... 18
8.Power Supply Instructions ................................................................................... 19
9. Precaustions ....................................................................................................... 19
10.Specications .................................................................................................... 19
11.Cables Requirements ........................................................................................ 20

-1-
1.Parts and Functions
Rainy Cover
DT596/KP
DT596F/KP Side View Mounting box
1
4 5 6
98
0 #
7
*
2 3 1
4 5 6
98
0 #
7
*
2 3
Camera Lens
Touch Sensitive
Digital Keypad
Speaker
Indicator(red)
Indicator(blue)
Nameplate
Call Button
Microphone
90 mm
28 mm
176 mm
220 mm
119 mm
1
4 5 6
98
0 #
7
*
2 3
1
4 5 6
98
0 #
7
*
2 3
Camera Lens
Touch Sensitive
Digital Keypad
Speaker
Nameplate
Call Button
Screws for panel
mounting
Microphone
Indicator(red)
Indicator(blue)
2.Terminal Descriptions
1 2 3 4
ON DIP
BUS
PL
S1+ S2+ S-
MIC adjustment
Lock Control Jumper
Doorstation Code DIP
Main Connect Port
1 2 3
SPK adjustment

-2-
Lock Control Jumper:
Doorstation Code DIP:
MIC
SPK
Main Connect Port:
•
3.Door Station Mounting
adjust camera angle
1 2
43
Drill holes in the wall to match the size of
screws and attach the rainy cover to the wall.
Attach the panel to the rainy cover Use the screwdriver and the screw
to fix the panel
Connect the cable correctly and adjust
right angle for camera
DT596/KP Mounting

-3-
DT596F/KP Mounting
1
90mm
174mm
52mm
2
43
Drill a hole in the wall to match the size of the
mounting box and attach to the wall.
Attach the panel to the mounting box and
use screws supplied to fix the panel
Place name label
Connect the cable correctly and adjust
right angle for camera
adjust camera angle
PS
Adjusting Camera Angle

-4-
Basic Connection
4.System Wiring and Connections
-
+
AC~
monitor
DPS PS4
L1 L2 PL S1+ S2+ S-
Placing Name Label
1
4 5 6
98
0 #
7
*
2 3

-5-
Electric Lock Connection
Door Lock Controlled with Internal Power
Unlock Mode
EB
*
LOCK
BUS PL S1+ S2+ S-
LOCK
2nd
1ST
2nd
EB
*1ST
Jumper position in
Connect two locks
2-3
1 2 3
EB
*
LOCK
BUS PL S1
+
S2
+S-
Jumper position in
Connect one lock
2-3
1 2 3
Door Lock Controlled with Dry Contact
Unlock Mode

-6-
Unlock parameter setting(set in monitor)
LOCK
BUS PL S1
+
S2
+S-
Take off the Jumper
POWER
SUPPLY
LOCK
BUS PL S1
+
S2
+S-
Take off the Jumper
POWER
SUPPLY
LOCK
1.Touch item on main
menu page.
2.Touch the screen anywhere
and hold for 2s.
3.Touch Installer setup item
4.A digital keypad and setting
instructions will be showed.
Manual
Monitor
Monitor
Memory
Playback
Album User Setup
09/30/2010 Thu.16:41
Close
Intercom Multimedia
About
?
H/W : --- a1.3
S/W: V17.11.418.00
Local addr: ---
Unlock timing: ---
Video standard: -
UI-CODE: ---
MCM-VER.: ---
Updated: ---
Home
Installer
setup
Caliber
TouchScreen
Code Number:[----]
[0010]#:Remove all remote control
[0011]#:Add remote control
[8000]#:Set as master unit 0
[8001]#:Set as slaver unit 1
[8002]#:Set as slaver unit 2
[8003]#:Set as slaver unit 3
[8004]#:Set as guard unit
[8005]#:Set as not guard unit
[8006]#:Panel on as slaver unit called
[8007]#:Panel off as slaver unit called
[8008]#:Date format:MM/DD/YYYY
[8009]#:Date format:DD/MM/YYYY
[8010]#:Set lock mode to 0
[8011]#:Set lock mode to 1
[8021]~[8029]
#Set the lock time of 1~9s
Multi language settings:
---
1
4
78
0
9
6
5
23
Cancel
Installation settings:

-7-
Multi Door Stations Connection
85~260VAC
DPS PS5
monitors
L1 L2 PL S1+ S2+ S- L1 L2 PL S1+ S2+ S-L1 L2 PL S1+ S2+ S-L1 L2 PL S1+ S2+ S-
123 4
ON
123 4
ON
123 4
ON
123 4
ON
1# Camera
ID=00
ID=10
ID=01ID=11
2# Camera3# Camera4# Camera
DBC4
A B C D
BUS

-8-
Basic IN-OUT Wiring Mode
Multi Monitors Connection
Code=0, DIP-6=off
Code=14, DIP-6=off
Code=15, DIP-6=on
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
monitor
monitor
monitor
123 4
ON
ID=00
85~260AC
DPS PS5
1
4
5 6
98
0 #
7
*
2 3

-9-
With DBC-4 Wiring Mode
HI
HI
monitor
monitor
monitor
monitor
monitor
monitor
monitor
monitor
DBC-4
A B C D
IN
OUT
DBC-4
A B C D
IN
OUT
85~260AC
DPS PS5
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
Code=15, DIP-6=on
Code=13, DIP-6=on
Code=3, DIP-6=on
Code=1, DIP-6=on
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
Code=14, DIP-6=on
Code=12, DIP-6=on
Code=2, DIP-6=on
Code=0, DIP-6=on
ID=00
1 2
ON
1
4
5 6
98
0 #
7
*
2 3

-10-
DCU Code =3(11)
Camera 1
Doorstation 1 Doorstation 2 Doorstation 3
Camera 2
1 2
ON
1 2
ON
ID=00 ID=10
1 2
ON
ID=01
1
4
5 6
98
0 #
7
*
2 3 1
4
5 6
98
0 #
7
*
2 3 1
4
5 6
98
0 #
7
*
2 3
85~260VAC
DPS PS5
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
HI
DBC-4
A B C D
IN
OUT
Code=0, DIP-6=on
CALL
UNLOCK
TALK/MON
IN-USE
Code=3, DIP-6=on Code=2, DIP-6=on
Code=1, DIP-6=on
CALL
UNLOCK
TALK/MON
IN-USE
CALL
UNLOCK
TALK/MON
IN-USE
CALL
UNLOCK
TALK/MON
IN-USE
1 2 3 4 5 6
ON
DCU
1 2 3 4
ON
DBC-4
A B C D
BUS
AC
Extending Connections with DCU unit

-11-
5.DIP Switches Setting
DIP Switches Settings of Monitor
DIP Switches Settings of Door Station
Setting Item Bit state Descriptions
ON(1)
=
OFF(0)
=
ON
ON
Bit state Setting Bit state Setting
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1234
ON
1234
ON
1234
ON
1234
ON
1234
ON
1234
ON

-12-
Bit state User Code Bit state User Code Bit state User Code
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
6. Functions Setting Up

-13-
Order Setting items Setting range Default value Setting code

-14-
1
4 5 6
98
0 #
7
*
2 3 blue
red
Input the master code.
(Default: [ ] +[#] )
- All settings will restore to their
default value.
-
When power on or activate
the reset all setting item,the
keypad checking will carry out,
during this time,the key
illumination will blink and the
touching operation is forbidden,
after finish checking,the key
illumination will stop blinking
and sent out a long sound of beep
- The master code is allowed 1~12
digits,the same code cannot be set
for both the user code and the
master code,it is recommended
that you modify the default master
code.
- The unlock time can be set on
both monitor and door station,
and the valid value is the number
you set last time.
(red)
ON
(blue)
OFF
Beep+, Beep
(red)
ON
(blue)
ON
Beep+, Beep
(red)
ON
(blue)
ON
Beep+, Beep
(red)
ON
(blue)
ON
Beep+, Beep
(red)
ON
(blue)
ON
Beep+, Beep
(red)
ON
(blue)
OFF
Beep+
(red)
ON
(blue)
OFF
Beep+
(red)
ON
(blue)
OFF
Beep+
(red)
ON
(blue)
OFF
Beep+
(red)
OFF
(blue)
OFF
Beep, Beep+
Inputting of code (ex.: 10)
range:00 or 10~99
Inputting of code (ex.: 09)
range:01~99
3.Setting the key
illumination time
4.Setting the
unlock time
2.Setting the master code
(Default 1234) (Default 10s) (Default 1s)
Inputting of new master code
(ex.: 4321)(1~12 digits)
Input the setting code.
Inputting of code
Input the setting code.
1.Reset all settings
00+#
1234+# 4321+#
01+#
10+# 09+#
Input the setting code.
02+#
Input the setting code.
03+#
-
When the “ cancel” key is pressed, the LED lights off, the buzzer beeps, and the system exits the setting mode
-
When there isn’t any operation in 10s, the LED lights off, the buzzer beeps, and the system exits the setting mode
*
- If the key illumination time is set
to 00,the key illumination will light
up all the time when power on.
- If the key illumination time is set to
10~99,the key illumination will light
up for 10~99 seconds.At this mode,
the key illumination lights off in
standby mode, touching any digital
key can illuminate,but this is the
invalid digital.

-15-
Input the master code.
(Default: [ ] +[#])
(red)
ON
(blue)
OFF
Beep+, Beep
(red)
ON
(blue)
ON
Beep+, Beep
(red)
ON
(blue)
ON
Beep+, Beep
(red)
ON
(blue)
ON
Beep+, Beep
(red)
ON
(blue)
ON
Beep+, Beep
(red)
ON
(blue)
OFF
Beep+
(red)
ON
(blue)
OFF
Beep+
(red)
ON
(blue)
OFF
Beep+
(red)
ON
(blue)
OFF
Beep+
7.Reset code setting 8. &# function setting 6.Setting operation tone
(Default ON) (Default Normal)(Default 0(opened))
Input the setting code.
Inputting of code
Input the setting code.
5.Setting the unlock mode
04+# 05+#
range:0:(open)/1:(close)
1+#
0/1 0/1 0/1
1+# 1+#1234+#
Input the setting code.
06+#
Input the setting code.
07+#
(ex.: 1)
Inputting of code Inputting of code Inputting of code
range:0:(on)/1:(off)
(ex.: 1)
range:0:(normal)/1:(reverse)
(ex.: 1)
*
(red)
OFF
(blue)
OFF
Beep, Beep+
-
When the “ cancel” key is pressed, the LED lights off, the buzzer beeps, and the system exits the setting mode
-
When there isn’t any operation in 10s, the LED lights off, the buzzer beeps, and the system exits the setting mode
*
*
*
*
- The unlock mode can be set on
both monitor and door station,
and the valid value is the number
you set last time.
- When the operation tone is
set to 0,pressing the digital
keypad will sent out a sound
of beep.
- When the operation tone is
set to 1,pressing the digital
keypad will blink one time.
- Cancel all the passwords except
the master code.
- Restore the master code to
default value(1,2,3,4)
- When the item is set to 0,press
the button to cancel the input,
and press the # button to confirm
the input.
- When the item is set to 1,press
the # button to cancel the input,
and press the button to confirm
the input .

-16-
Input the master code.
(Default: [ ] +[#])
(red)
ON
(blue)
OFF
Beep+, Beep
(red)
ON
(blue)
ON
Beep+, Beep
(red)
ON
(blue)
ON
Beep+, Beep
(red)
ON
(blue)
OFF
Beep+
(red)
ON
(blue)
OFF
Beep+
10.Interference resistant
grade setting
Input the setting code. Input the setting code.
9. Call tone setting
08+#
0/1
1+#
09+#
Inputting of code (ex.: 3)
range:0~5
3+#
Inputting of code (ex.: 1)
range:0(enable)/1:(disable)
(Default 2)
(Default enable)
(red)
OFF
(blue)
OFF
Beep, Beep+
-
When the “ cancel” key is pressed, the LED lights off, the buzzer beeps, and the system exits the setting mode
-
When there isn’t any operation in 10s, the LED lights off, the buzzer beeps, and the system exits the setting mode
*
-
The larger you set the
interference resistant grade,
the stronger it will be,but the
sensitivity of the keypad will
be more lower.
- The interference resistant
grade setting also will activate
the keypad checking.
-
If the item is set to 0,the unit will
respond a call tone when pressing
the “CALL” button.
- If the item is set to 1, the unit will
have no responds when pressing
the “CALL” button.

-17-
Input the master code.
(Default: [ ]+[#] )
(red)
ON
(blue)
OFF
Beep+, Beep
(red)
ON
(blue)
ON
Beep+, Beep
(red)
ON
(blue)
ON
Beep+, Beep
(red)
ON
(blue)
ON
Beep+, Beep
(red)
ON
(blue)
ON
Beep+, Beep
(red)
ON
(blue)
OFF
Beep+
(red)
ON
(blue)
OFF
Beep+
(red)
ON
(blue)
OFF
Beep+
(red)
ON
(blue)
OFF
Beep
Inputting of code (ex.: 2011)
1~12 digits
Inputting of code (ex.: 2012)
1~12 digits
14.Setting the code
for user group1
15.Setting the code
for user group2
13.Setting the code
forTemporary2
Input the setting code. Input the setting code.
12.Setting the code
forTemporary1
18+# 19+# 21+# 60+#
2011+#
Inputting of code (ex.: 1006)
1~12 digits
1006+#
Inputting of code (ex.: 2011)
1~12 digits
2011+# 2012+#
Input the setting code.
(ex.:21)
Input the setting code.
(ex.:60)
20~59 60~99
-
When the “ cancel” key is pressed, the LED lights off, the buzzer beeps, and the system exits the setting mode
-
When there isn’t any operation in 10s, the LED lights off, the buzzer beeps, and the system exits the setting mode
(red)
OFF
(blue)
OFF
Beep, Beep+
*
- When input the correct temporary password to release the door,
the system will clear the temporary password after 60 seconds
automatically.But you should know that the password is valid within
60 seconds after inputing the correct temporary password
- The temporary1 is used to release the first lock,and the temporary
2 is used to release the second lock.
- If the password length exceeds 12 digits, the system will sent out
the sound of “beep,beep,beep,beep”,and the digitals you input before
will be cleared at the same time.
- The temporary code can not be set the same as the master code
and user code.
- The user code group1 is used to release the first lock,and the user code
group2 is used to release the second lock.
- The user code group1 and user code code group2 can contain 40
group passwords
- If the password length exceeds 12 digits, the system will sent out the
sound of “beep,beep,beep,beep”,and the digitals you input before will
be cleared at the same time.
- The user code can not be set the same as the master code and
temporary code.

-18-
7.Unlock Operations
(red)
ON
(blue)
OFF
Beep+
(red)
OFF
(blue)
ON
Beep+
Blue LED lights up
(during relay2 operation)
Red LED lights up
(during relay1 operation)
Unlocking of user code
This manual suits for next models
1
Table of contents
Other V-Tec Intercom System manuals

V-Tec
V-Tec AT27TD7 User manual

V-Tec
V-Tec DT24 Series User manual

V-Tec
V-Tec DMR11 Series User manual

V-Tec
V-Tec DMR18S User manual

V-Tec
V-Tec Livila VT27 User manual

V-Tec
V-Tec DT-DJ4S User manual

V-Tec
V-Tec DT591 User manual

V-Tec
V-Tec 27SDTD7-V1 User manual

V-Tec
V-Tec DT-DJ4A User manual

V-Tec
V-Tec DT-DJ5A User manual

V-Tec
V-Tec DT-DJ4 User manual

V-Tec
V-Tec 37TD7-V1 User manual

V-Tec
V-Tec DJ4A User manual

V-Tec
V-Tec VIDEO DOOR PHONE SYSTEM User manual

V-Tec
V-Tec dt-dj5a User manual

V-Tec
V-Tec DT31M User manual

V-Tec
V-Tec 2-WIRE User manual

V-Tec
V-Tec DMR11 User manual

V-Tec
V-Tec 2Easy DMR18s User manual

V-Tec
V-Tec DT16D3 User manual