code
162728 Per motori con coppia fino a
For motors with torque up to
Pour moteurs avec couple jusqu’à
Para motores con par de hasta
Para motores com binário até
Für Motoren mit Drehmoment
Voor motoren met een koppel tot
30 Nm
code
162847 30 Nm
code
162829 50 Nm
Fig. 1
Fig. 2

- 3 -
Fig. 4
Fig. 3

White
Blue
Brown
Black
Yellow / Green
White
Blue
Brown
Black
Yellow / Green
METEO / HURRICANE
WIND / MISTRAL
N
N
L
L
N
L
ICOLLEGAMENTI GB CONNECTIONS FBRANCHEMENTS ECONEXIONES
1. BIANCO - ingresso sensori WHITE - input of sensors BLANC - entrée capteurs BLANCO - entrada sensores
2. BLU - Neutro BLUE - Neutral BLEU - neutre AZUL - Neutro
3. MARRONE - Fase BROWN - Phase MARRON - phase MARRON - Fase
4. NERO - Pulsante BLACK - External switch NOIR - touche NEGRO - Pulsador
5. GIALLO-VERDE - Terra YELLOW-GREEN - Ground JAUNE-VERT - terre AMARILLO-VERDE - Tierra
PLIGAÇÕES DANSCHLÜSSE NL AANSLUITINGEN
1. BRANCO - entrada sensores WEISS - Sensoreneingang WIT - Aansluiten van sensoren
2. AZUL - neutro BLAU - Nullleiter BLAUW - Neutraal
3. MARROM - fase BRAUN - Phase BRUIN - Fase
4. PRETO - botão SCHWARZ - Taste ZWART - Drukknop
5. AMARELO-VERDE - terra GELB-GRÜN - Masse GEEL-GROEN - Aarding
230V MODELS

ITALIANO
- 5 -
Yellow
White
Black
Red
Yellow / Green
Yellow
White
Black
Red
Yellow / Green
METEO / HURRICANE
WIND / MISTRAL
N
N
L
L
N
L
ICOLLEGAMENTI GB CONNECTIONS FBRANCHEMENTS ECONEXIONES
1. GIALLO - ingresso sensori YELLOW - input of sensors JAUNE - entrée capteurs AMARILLO - entrada sensores
2. BIANCO - Neutro WHITE - Neutral BLANC - neutre BLANCO - Neutro
3. NERO - Fase BLACK - Phase NOIR - phase NEGRO - Fase
4. ROSSO - Pulsante RED - External switch ROUGE - touche ROJO - Pulsador
5. VERDE - Terra GREEN - Ground VERT - terre VERDE - Tierra
PLIGAÇÕES DANSCHLÜSSE NL AANSLUITINGEN
1. AMARELO - entrada sensores GELB - Sensoreneingang GEEL - Aansluiten van sensoren
2. BRANCO - neutro WEISS - Nullleiter WIT - Neutraal
3. PRETO - fase SCHWARZ - Phase ZWART - Fase
4. VERMELHO - botão ROT - Taste ROOD - Drukknop
5. VERDE - terra GRÜN - Masse GROEN - Aarding
120V MODELS

ITALIANO
- 6 -
Modello carico* coppia velocità alimentazione potenza tempo di
funzionamento
giri fine
corsa
lunghezza
(L)
Model load* torque speed power supply power working time limit
switch
range
length
(L)
Kg Nm rpm V/Hz W min. n° mm
LEX-RM20-230V 35 20 15 230/50 145 4 22 660
LEX-RM30-230V 55 30 15 230/50 191 4 22 660
LEX-RM40-230V 80 40 15 230/50 198 4 22 660
LEX-RM50-230V 95 50 12 230/50 205 4 22 660
LEX-RM20-120V 35 20 19 120/60 276 4 22 660
LEX-RM40-120V 80 40 13 120/60 363 4 22 660
LEX-HRM30-230V 55 30 15 230/50 191 4 22 769
LEX-HRM40-230V 80 40 15 230/50 198 4 22 769
LEX-HRM50-230V 95 50 12 230/50 205 4 22 769
17
25L
52
M4
48
59
Ø45
24
25L
60
48
76,6
Ø45
M6

ENGLISH
- 19 -
EU DECLARATION OF CONFORMITY
AND DECLARATION OF
INCORPORATION FOR PARTLY
COMPLETED MACHINERY
Declaration in accordance with the Directives: 2014/35/UE
(LVD); 2014/30/UE (EMC); 2006/42/EC (MD) APPENDIX II,
PART B
The manufacturer V2 S.p.A., headquarters in
Corso Principi di Piemonte 65, 12035, Racconigi (CN), Italy
Under its sole responsibility hereby declares that:
the partly completed machinery model(s):
• LEX-RM20-230V (*), LEX-RM30-230V (*), LEX-RM40-230V (*),
LEX-RM50-230V (*), LEX-RM20-120V (*), LEX-RM40-120V (*)
• LEX-HRM30-230V (*), LEX-HRM40-230V (*), LEX-HRM50-230V (*)
Description: electromechanical actuator for awnings and
rolling shutters
- is intended to be installed on awnings and rolling shutters
to create a machine according to the provisions of the
Directive 2006/42/EC. The machinery must not be put into
service until the final machinery into which it has to be
incorporated has been declared in conformity with the
provisions of the Directive 2006/42/EC (annex II-A).
- is compliant with the applicable essential safety requirements
of the following Directives:
Machinery Directive 2006/42/EC (annex I, chapter 1)
Low Voltage Directive 2014/35/EU
Electromagnetic Compatibility Directive 2014/30/EU
Radio Directive 2014/53/EU
Directive ROHS2 2011/65/CE
The relevant technical documentation is available at the national
authorities’ request after justifiable request to:
V2 S.p.A., Corso Principi di Piemonte 65,
12035, Racconigi (CN), Italy
The person empowered to draw up the declaration and to provide
the technical documentation:
Giuseppe Pezzetto
Legal representative of V2 S.p.A.
Racconigi, 1st June 2015
(*) made in extra EU Countries on behalf of V2 S.p.A.
mIMPORTANT REMARKS
• Please read the instruction carefully before installation
• Follow all instructions, since incorrect installation can lead to
severe injury
• The installation must be done by a technician following the
safety norms in force
• Only apply to authorized personnel to replace the feeding
cable of the motor
• Do not pierce nor insert screws in the whole length of the
motor
• Avoid any contact of the motor with liquids
• Avoid to crush or knock over the motor
• Possible tampering or wrong connections are not covered by
guarantee
•If a manual release is provided, the actuating member is to be
installed at a height less than 1,8m
•Before installing the drive, remove any unnecessary cords and
disable any equipment not needed for powered operation.
•For installation for awnings, a horizontal distance of at least
0,4 m is to be maintained between the fully unrolled driven
part and any permanent object
•The power supply cable should not be exposed to sunlight or
rain directly
•Assure that all accessories have been fixed so that the motor
works without any mechanical problem. The loading weight
should be matched with the output power of the motor
•Electrical connection must be done by professional technicians
to operate in conformity with the rules
• Do not allow children to play with fixed controls
• Keeps remote controls away from children
• Frequently examine the installation for imbalance and sings of
wear or damage to cables and springs
• Do not use if repair or adjustment is necessary
• Moving parts of the drive must be installed higher than 2.5 m
above the floor or other level that could provide access to it
• The actuating member of a biased-off switch is to be located
within direct sight of the driven part but away from moving
parts. It is to be installed at a minimum height of 1.5 m
• Fixed controls have to be installed visibly
• The appliance can not be used in outside
INSTALLATION
• Fix the stirrup Gto the wall.
• Insert the crown Ain the driving wheel Bof the limit switch
(fig.1).
• Insert the pulley Con the pivot of the motor D(fig.1).
• Insert the copper pin Fon the pulley C.
• ONLY for the models with emergency handling:
- Put the eyelet L in the hole
- Fix the eyelet with the screw M and the washer N
• Insert completely the motor in the roll-tube (fig.2).
• Fix the roll-tube to the driving wheel with m 4 x10 screw
(fig.2).
LIMIT SWITCH ADJUSTMENT
• The limit switches system is electromechanical and through a
micro-switch it interrupts the feeding of the motor when the
roller shutter or the awning reaches the limit of opening and
closing.
• The limit switches are pre-adjusted to approximately 5 crown
revolutions.
• To adjust the opening and closing limit is necessary to turn the
adjusting screw placed on the head of the motor through the
plastic screwdriver included in the box (fig.4).
• Feed the motor and observe the sense of rotation of the pulley
and/or of the crown ; turn the adjusting screw towards (+)
to increa se the speed of the motor, turn the adjusting screw
towards (-) to decrease it (fig.4).
• Reverse the direction of revolution of the motor and operate
on the second limit switch (fig.4).

ENGLISH
- 20 -
DESCRIPTION
This opening system is made of a tubular motor with built-in
control unit with the following characteristics:
• It is provided with a 434.15 MHz super-heterodyne radio
receiver.
• Up to 48 different channel can be stored on each central unit.
• It is driven by means of transmitters PROTEO, DUO, ARTEMIS,
ADLER and DEV-T1.
• It is possible to drive the awning / rolling shutter also by mean
of an external push-button (type: Normally Open, each series
or model).
• The programming phase can be effected via radio or by means
of an external switch.
• It is necessary to use a sesor model WIND, MISTRAL, METEO,
HURRICANE.
FUNCTIONING WITH EXTERNAL WIRED
SWITCH
Pressing the external wired switch, the control unit has the
following functioning logic:
OPENS aSTOPS aCLOSES aSTOPS aOPENS ...
FUNCTIONING WITH TRANSMITTERS
At each push button pressure, the functioning logic is the
following.
UP: CLOSES aCLOSES aCLOSES
STOP: STOPS aSTOPS aSTOPS
DOWN: OPENS aOPENS aOPENS
SENSOR ACTIVATION
To activate the sensors function, at least one transmitter must be
stored.
mIMPORTANT:
• Anemometer causes inhibition of functioning of both radio
transmitter and external push button for ca. 8 minutes.
• The anemometrical sensor should be installed close to the
awnings, in order to avoid damages in case of very strong
wind.
WORKING TIME OF MOTOR
The control unit stops the motor movement after 2 minutes: in
case of limit switches malfunction this “time out” avoids the
motor overheating.
TRANSMITTERS OF THE RANGE
PROTEO / DUO
Using a transmitter of the range PROTEO / DUO it is possible
changing the functions of the control unit controlling the tubular
motor.
The transmitter is equipped with a 10 switches dip-switch thanks
to which it is possible to change the desired functions: set on ON
the switch corresponding to the function required and follow
carefully the dedicated procedure.
WARNING: all the other switches have to be set on OFF
DIP-SWITCHES
PROG
SWITCH FUNCTION
1Storage of the transmitters
3Deletion of all the stored transmitters
7Storing of the level of intervention of the wind
sensor
8Programming of the level of intervention of the sun
sensor
10 Programming of the level of temperature
2 - 4 - 5
6 - 9
NOT USED

ENGLISH
- 21 -
SWITCH 1: STORAGE OF THE TRANSMITTERS
mWARNING: the first transmitter stored fixes the direction of
motion of the motor.
To store a transmitter TX1 on a blank control unit proceed
as follows:
1. Power only the control unit to be programmed
2. Set on ON the switch 1 of the transmitter.
3. Multichannel transmiter only: press several times the key SELC
of the transmitter TX1 until displayed the selected channel (by
the leds or on the display).
4. Press and keep pressed (for about 5 seconds) the key PROG of
the transmitter TX1 until the motor starts to move in one way.
5. Release the key PROG: the motor stops.
6. Press the keys UP or DOWN depending on the way of motion
of the roll-up shutter before stopping:
- if the roll-up shutter was going up, press the key UP;
direction acquired: the key UP moves the roll-up shutter
UPWARDS, the key DOWN moves the roll-up shutter
DOWNWARDS.
- if the roll-up shutter was going down, press the key
DOWN; direction acquired: the key DOWN moves the roll-
up shutter DOWNWARDS, the key UP moves the roll-up
shutter UPWARDS.
7. Set the switch 1 to OFF.
8. Try to operate the roll-up shutter and check that it works
with the logic above described. If the logic is reversed, it is
necessary to delete all the codes stored (read Switch 3) and
start again the above procedure.
To add another transmitter TX2 to the control unit it is
necessary to use a remote control previously stored (TX1)
and proceed as follows:
1. Multichannel transmiter only: press several times the key SELC
of the transmitter TX1 until displayed the channel stored (by
the leds).
2. Multichannel transmiter only: press several times the key SELC
of the new transmitter TX2 until display the channel to be
stored (by the leds).
3. Take the roll-up shutter to half its way with TX1.
4. Set to ON the switch 1 of the transmitter TX1.
5. Press and keep pressed for about 5 seconds the key PROG of
the TX1 until the motor starts to move.
6. Release the key PROG, the motor stops.
7. Press the key UP or DOWN of the TX2: the transmitter is
stored with the same logic of the TX1.
SWITCH 3: DELETION OF ALL THE STORED
TRANSMITTERS
To delete all the transmitters stored on the control unit it
is necessary using a remote control previously stored and
proceed as follows:
1. Power only the control unit to be programmed
2. Multichannel transmiter only: press several times the button
SELC on the transmitter until displayed the channel stored
(by the leds)
3. Position the roll-up shutter at the mid-height.
4. Set on ON the switch 3 of the transmitter.
5. Press and keep pressed the button PROG of the transmitter
until the motor moves in both the ways for 1 second, showing
the end of deletion.
6. Release the button PROG and set on OFF the switch 3 of the
transmitter.
To delete all the codes by means of a transmitter non-
stored, proceed as follows:
1. Position the retractable at the mid-height.
2. Switch off power supply of the system.
3. Set on ON the switch 3 of a transmitter.
4. Press and keep pressed the button PROG.
5. Supply power only to the control unit on which to make the
deletion: after about 1 second the motor moves in both the
ways showing the correct deletion.
6. Release the button PROG and set on OFF the switch 3.
SWITCH 7: STORING OF THE LEVEL OF
INTERVENTION OF THE WIND SENSOR
mWARNING: to make the awning close, the wind sensor has
to detect a value higher then the set threshold value for at least
5 seconds. The automation is blocked for 8 minutes when the
awning is closed because of strong wind.
To set the level of intervention of the wind sensor it is
necessary to use a remote control previously stored and
proceed as follows:
1. Multichannel transmiter only: press several times the button
SELC of the transmitter until shown by leds the channel
stored.
2. Position the roll-up shutter at the mid-height
3. Set on ON the switch 7 of the transmitter.
4. Press and keep pressed (for 5 about seconds) the button PROG
of the transmitter until the motor moves jerkily in both the
ways showing that it enters the storing.
5. The number of jerks made by the motor corresponds to the
level currently set:
1 jerk = level 1 = 10 Km/h
2 jerks = level 2 = 15 Km/h
3 jerks = level 3 = 20 Km/h
4 jerks = level 4 = 30 Km/h (default)
5 jerks = level 5 = 40 Km/h
6. To increase the level press button UP, to decrease it press
button DOWN.
7. As soon as the control unit receives the control, it shows the
new level moving the motor with the corresponding number
of jerks.
8. To exit the programming press STOP: the motor displays again
the set level and exits.

ENGLISH
- 22 -
SWITCH 8: PROGRAMMING OF THE LEVEL OF
INTERVENTION OF THE SUN SENSOR
mWARNING: to make the awning open the sun sensor has
to detect a value higher then the set threshold value for at least 8
minutes. To make it close, the sensor has to detect a value lower
then the set threshold value for at least 8 minutes.
Interruptions of light (due to clouds) shorter than a minute are
not detected, while the 8-minute timer is set at zero when longer
than one minute.
To set the level of intervention of the sun sensor it is
necessary to use a remote control previously stored and
proceed as follows:
1. Multichannel transmiter only: press several times the button
SELC of the transmitter until shown by leds the channel
stored.
2. Position the roll-up shutter at the mid-height
3. Set on ON the switch 8 of the transmitter.
4. Press and keep pressed (for 5 about seconds) the button PROG
of the transmitter until the motor moves jerkily in both the
ways showing that it enters the storing.
5. The number of jerks made by the motor corresponds to the
level currently set:
1 jerk = level 1 = 2 Klux
2 jerks = level 2 = 5 Klux
3 jerks = level 3 = 10 Klux (default)
4 jerks = level 4 = 20 Klux
5 jerks = level 5 = 40 Klux
6. To increase the level press button UP, to decrease it press
button DOWN.
7. As soon as the control unit receives the control, it shows the
new level moving the motor with the corresponding number
of jerks.
8. To exit the programming press STOP: the motor displays again
the set level and exits.
9. Set on OFF the switch 8
To disabling the sun sensor proceed as follows:
1. Multichannel transmiter only: press several times the button
SELC of the transmitter until shown by leds the channel
stored.
2. Position the roll-up shutter at the mid-height
3. Press the key STOP and immediately after the key DOWN
(keeping pressed the key STOP) until the motor moves for
about one second in both the ways, indicating that the
procedure has been finished.
To enable again the sun sensor it is enough to repeat
the procedure above using the key UP instead of the key
DOWN.
SWITCH 10: PROGRAMMING OF THE LEVEL
OF TEMPERATURE
The temperature can be set on 5 levels, under which the sun
sensor must not open the awning, even if the light intensity has
exceeded the level set by switch 8
This function is particularly useful in Countries with wintry
weather, where sunny but very cold days are frequent. In this case,
it is not necessary to open the awnings, to let the sun warm the
inner rooms.
To set the level of temperature it is necessary to use a
remote control previously stored and proceed as follows:
1. Multichannel transmiter only: press several times the button
SELC of the transmitter until shown by leds the channel
stored.
2. Position the roll-up shutter at the mid-height
3. Set on ON the switch 10 of the transmitter.
4. Press and keep pressed (for 5 about seconds) the button PROG
of the transmitter until the motor moves jerkily in both the
ways showing that it enters the storing.
5. The number of jerks made by the motor corresponds to the
level currently set:
1 jerk = level 1 = sensor disabled (default)
2 jerks = level 2 = 0°C
3 jerks = level 3 = 5°C
4 jerks = level 4 = 10°C
5 jerks = level 5 = 15°C
6. To increase the level press button UP, to decrease it press
button DOWN.
7. As soon as the control unit receives the control, it shows the
new level moving the motor with the corresponding number
of jerks.
8. To exit the programming press STOP: the motor displays again
the set level and exits.
9. Set on OFF the switch 10
Other manuals for LEX-RM
1
This manual suits for next models
10
Table of contents
Other V2 Engine manuals