VanGaa Lighting VG-LVF400G User manual

VG-LVF400G 400W RGBAL LED Profile Spot light User Manual VG-LVF400G 400W RGBAL LED Profile Spot light User Manual
400W RGBAL LED Profile Spot Light
VG-LVF400G
CE RoHS
User Manual
Please read this user manual before using this product!
Keep it for further reference!
http://www.vangaa.com

VG-LVF400G 400W RGBAL LED Profile Spot light User Manual VG-LVF400G 400W RGBAL LED Profile Spot light User Manual
INDEX
ⅠPRODUCT MAIN FEATURES ............................................. 01
ⅡOVERVIEW AND DIMENSIONS ......................................... 02
ⅢSAFETY INFORMATION ................................................... 02
ⅣPOWER CONNECTION...................................................... 03
ⅤCONTROL PANNEL .......................................................... 05
ⅥDMX PROTOCOL.............................................................. 10
ⅦTECHNICAL SPECIFICATION ........................................... 11
ⅧLUX CHART ..................................................................... 12
ⅨAPPENDIX ........................................................................ 13
Thank you for using our product! Please read this manual carefully and completely. For
technical reference in future, please keep this user manual well. This user manual contains
all installation and operation information of this LED Profile Spot Light, it’s very useful for
user to install and operate the light. Please strictly abide by the relevant instruction for the
installation and operation.
This light has very beautiful appearance. Based on the LED Film and Television Light
Technology, using high brightness COB LED chips beads matrix arrangement of large area,
through the whole aluminum shell to realize heat dissipation naturally, we have designed
this light. This light has high brightness, good head dissipation, ultra-quiet and other
features. It can satisfy the requirement of indoor movie filming for the lighting layout. It is
a good substitute of the traditional Fresnel spot light, which is very suitable for the studio
room, TV station, Meeting room, stage, show and other entertainment places.
This light meets the following criteria:
GB7000.1-2007/IEC60598-1:2003
GB7000.217-2008/IEC60598-2-17:1984+A2:1990
ⅠPRODUCT MAIN FEATURES
The light’s lighting function is controlled by DMX-512 and RDM, very convenient;
Using international standard (1990) DMX single, digital control panel display;
With 12 DMX channel layout, every color can be controlled;
Dimmer range: 0~100%, 0~15% dimmer smoothly;
CRI more than 92, 1800-10000K color temperature adjustable, light effective distance is
3~50 meters;
Cast aluminum radiator, equips copper tube radiator, and mute fan cooling, realize the
01

VG-LVF400G 400W RGBAL LED Profile Spot light User Manual VG-LVF400G 400W RGBAL LED Profile Spot light User Manual
silent, intelligent temperature control system, improve the quality of our products stable
performance, apply to indoor installation.
Using brand LED chips, integrated encapsulation, improve reliability and long lifespan.
Using the advanced optical reflective material, make the light on the projection distance
and brightness is higher than traditional film soft light.
ⅡOVERVIEW AND DIMENSIONS
All dimensions are in millimeters
ⅢSAFETY INFORMATION
※Important
Every person involved with the installation, operation and maintenance of this device has to
be qualified and follow the instructions of this manual. Manufacturer will not with
responsibility for those operations which are not according to this Instruction.
Verify that the voltage matches the rated voltage.
When the voltage is 110V, Do not connect more than 10 lightings in total to AC mains
power in one interconnected daisy chain
When the voltage is 220V, Do not connect more than 20 lightings in total to AC mains
power in one interconnected daisy chain
Before using the fixture, check that all power distribution equipment and cables are in
perfect condition and rated for the current requirements of all connected devices.
Always ground (earth) the fixture electrically.
Avoiding hit the Light when you are move or install the light.
The minimum distance between light-output and the illuminated surface must be more
than 0.5 meters. Keep all combustible materials (for example fabric, wood, paper) at least
0.2 meters away from the fixture.
Do not expose the fixture to rain or moisture.
Avoid looking directly into the light source (especially those who suffer from epileptic fits)
Maximum ambient temperature (Ta) is 40°C. Do not operate fixture at temperatures higher
than this.
The Maximum surface temperature is 50°C
When suspending the fixture above ground level, verify that the structure can hold at least
10 times the weight of all installed devices.
Verify that all external covers and rigging hardware are securely fastened and use an
approved means of secondary attachment such as a safety cable.
ⅣPOWER CONNECTION
INSTALLING A NENUTRIK CONNECTOR ON A POWER CABLE
03
02
03

VG-LVF400G 400W RGBAL LED Profile Spot light User Manual VG-LVF400G 400W RGBAL LED Profile Spot light User Manual
Put bushing and chuck onto the cable.
Prepare cable as shown above. The power cable must is a three-conductor 2.5mm2 cable.
Insert the wire into the terminals and fasten the clamping device by a flat screw driver.
Push insert and chuck into housing (pay attention to the guiding keyway).
Fasten bushing.
The color-coding schemes and some possible pin identification schemes; if pins are not
clearly identified, or if you have any doubts about proper installation, consult a qualified
electrician.
RELAYING POWER TO OTHER DEVICES
The lightings can be linked in a chain by power cables which installed a blue and a
light-gray connectors on the two ends. The light-gray connector connects to the power out
socket of the first lighting, and the blue connector connects to the power in socket of the
subsequent lighting, and so on.
The power cable must is a three-conductor 2.5mm2 cable.
When the voltage is 110V, Do not connect more than 10 lightings in total to AC mains
power in one interconnected daisy chain.
When the voltage is 220V, Do not connect more than 20 lightings in total to AC mains
power in one interconnected daisy chain.
PHYSICAL INSTALLATION
This lighting can be placed on a horizontal surface such as a stage or clamped to a truss or
similar rigging structure in any orientation using a rigging clamp.
When suspending the fixture above ground level, verify that the structure can hold at least
10 times the weight of all installed devices.
Verify that all external covers and rigging hardware are securely fastened and use an
approved means of secondary attachment such as a safety cable.
ⅤCONTROL PANNEL
Wire color
Conductor
Symbol
Brown
Live
L
Blue
Neutral
N
Yellow/green
ground
05
04

VG-LVF400G 400W RGBAL LED Profile Spot light User Manual VG-LVF400G 400W RGBAL LED Profile Spot light User Manual
BUTTON
MENU
ENTER
DOWN
UP
Call the main menu, or escape the current menu, (i.e. return to the
upper menu and give up the selected item or parameter).
Confirm the selected item or parameter, (i.e. enter into the next menu,
or escape the current menu and save the selected item or parameter).
Browse the menu item backward or decrease the parameter.
Browse the menu item forward or increase the parameter.
MAIN MENU
The way into the menu as below:
1. Press ENTER when the display show the title information;
2. Press UP or DOWN button to choose the right menu which you need;
3. Press ENTER into the menu;
4. Press UP and DOWN button to set the parameter or setting;
5. Press ENTER to save the setting;
6. Press MENU/SET button to back.
MENU MAP
07
06
Table of contents
Other VanGaa Lighting Lighting Equipment manuals