Vauconsant EXIGENCE A62608VCP User manual

USER MANUAL
Rue Charles Hermite
Z.I des Sables – BP 59
54110 Dombasle-sur- eurthe
France
Tel: + 33 (0)3 83 45 82 82
Fax: +33 (0)3 83 45 82 93
www.vauconsant.com
Public limited company with executive
and supervisory board capitalised at €1,000,000
Chèques Postaux account: 2145 J Nancy
NAF 28.93.Z
RCS (French business registration n°) Nancy B 757.804.042
EU VAT number: FR 52 757 804 042
E
EX
XI
IG
GE
EN
NC
CE
E
–
–
T
TO
OU
UG
GH
HE
EN
NE
ED
D
G
GL
LA
AS
SS
S
T
TO
OP
P
F
FR
RE
EE
E
S
SP
PA
AC
CE
E
B
BE
EL
LO
OW
W
W
WI
IT
TH
H
P
PR
RE
ES
SE
EN
NT
TA
AT
TI
IO
ON
N
H
HE
EA
AT
TI
IN
NG
G
D
DI
IS
SP
PL
LA
AY
Y
A62608VCP (2GN) :
9 0 x 820 x 900 (+600) mm
A6261 VCP ( GN) : 1 80 x 820 x 900 (+600) mm
A62615VCP (4GN) : 1580 x 820 x 900 (+600) mm
A62619VCP (5GN) : 19 0 x 820 x 900 (+600) mm

USER MANUAL
Vauconsant SA, all rights reserved A622xx & E633xx -rev0-ENG, 2/12/2010 - 2 -
anual to be read and kept
Contents
Introduction …………………………………………………………
3
Installation / Controls ……………………………………………..
4
Commissioning / Use ……………………………………………..
6
Cleaning / Diagnostic ……………………………………………..
7
Maintenance ……………………………………………………….
8
Electric diagram ……………………………………………………
9
Spare parts …………………………………………………………
10
Technical support / Warranty …………………………..………...
11

USER MANUAL
Vauconsant SA, all rights reserved A622xx & E633xx -rev0-ENG, 2/12/2010 - 3 -
Introduction
Performance of the unit
the heating top with heating presentation display is designed to keep food warm at a temperature
above 63°C, according to hygiene requirements, for 90 minutes, using GN1/1 65 mm deep gastronorme
trays.
The temperature of the food provided should be between 70°C and 80°C.
These units comply with applicable EC norms and should be installed and used following the
instructions in this manual to ensure good performance and to be covered by the warranty.

USER MANUAL
Vauconsant SA, all rights reserved A622xx & E633xx -rev0-ENG, 2/12/2010 - 4 -
Installation / Controls
•
Installation:
o
Before connecting to the mains, you must check that the existing voltage is suitable for the
one mentioned on the unit's identity plaque.
Connect to the mains on the cabling fuse holder or connect the plug to the mains in the
case of a mobile unit.
The line should be protected by a differential circuit breaker on the general electricity panel.
•
Overhang adjustment
The unit’s overhangs should be positioned as shown below.
The unit should be level.

USER MANUAL
Vauconsant SA, all rights reserved A622xx & E633xx -rev0-ENG, 2/12/2010 - 5 -
•
Assembly / dismantling of facing
•
Controls:
The controls are placed on a removable panel to the right of the unit.
oAn energy doser with orange on-off light for the toughened glass plate or plates.
oAn energy doser with orange on-off light for the toughened glass plate or plates on the
heating shelf.
oA switch with orange light for the heating display option.
ounting with
spanner (rack supply
)
Step 1
Step 2

USER MANUAL
Vauconsant SA, all rights reserved A622xx & E633xx -rev0-ENG, 2/12/2010 - 6 -
Commissioning / Use
•
Commissioning:
Pre-heating of toughened glass plates 30 minutes before use.
The heating display should be switched on at the start of service.
•
Use:
Toughened glass
Turn the energy doser button to the right, set it to the maximum position. This position maintains
the temperature of food above 63°C which is the minimum temperature defined by the hygiene
department.
To maintain this temperature, it is indispensable to heat food to a temperature between
+70°C and +80°C.
GN A/A gastronorme trays should be 65 mm deep.
The temperature of the heating tops may be set from 40 to 110 °C.
Lighting
Press the switch:
Position 0: Off
Position 1: On.
IMPORTANT / WARNING
•It is imperative not to add containers with a temperature above 160°C to avoid
weakening and breaking the plate.
•If the surface of the toughened glass plate is cracked or has just broken, immediately
switch off the electricity supply to the energy doser that controls the plate
•Toughened glass heating plates are shock-sensitive.

USER MANUAL
Vauconsant SA, all rights reserved A622xx & E633xx -rev0-ENG, 2/12/2010 - 7 -
Cleaning
Always take care to switch off the appliance with energy doser before cleaning. This unit is not
impermeable to water. Do not use a high pressure water jet to clean it inside or out.
Every day:
•Metal surfaces:
Stainless steel should be cleaned with soapy warm water or a special product for high quality
metal surfaces. Never use abrasive sponges or scourers to avoid scratching the surface.
•Glass:
All glass displays must be cleaned using a high quality glass cleaning product and clean cloth.
Never use abrasive sponges or scourers to avoid scratching the surface.
Diagnostic
Symptoms Possible causes Remedies
No electricity supply Check the general circuit breaker
Burnt fuse Check the fuse in the electric cabling
Orange light off
No heat Faulty supply Check the supply cable
Defective toughened glass
plate Replace the toughened glass plate
Orange light on
No heat Cable disconnected or cut Check and test electricity input to the toughened glass
plates
Halogen bulb burnt Replace the bulb with one of equivalent power
A halogen lamp
does not come on Supply of this defective
halogen Check supply of halogen
No electricity supply Check the general circuit breaker
Burnt fuse Check the fuse in the electric cabling
Faulty supply Check the supply cable to the heating display
None of the
halogen lights
come on Defective switch Check the switch, replace it if necessary
NB
•
Bulbs should be replaced with bulbs of equivalent power. (see the Spare Parts section)
•Fuses should be replaced by gG fuses of the same calibre.

USER MANUAL
Vauconsant SA, all rights reserved A622xx & E633xx -rev0-ENG, 2/12/2010 - 8 -
Maintenance
Always remember to switch off the appliance by opening the fuse holder before any
maintenance operations.
•Toughened glass:
The electrical part of the toughened glass
plates is accessible by dismantling the riveted
lid under the plate.
•Built-in lighting:
Water-resistant lighting to be built-in is
clipped into the support sheet.
•Electric cabling:
Electric cabling is fixed behind the built-in control panel. To access this, remove the 4 screws
holding the panel.
The installer should check electric connections when commissioning the unit then once a year.
Any maintenance operation should be done by an electrician.
Cover
Top
Toughened glass
Support sheet
Water
-
resistant lighting

USER MANUAL
Vauconsant SA, all rights reserved A622xx & E633xx -rev0-ENG, 2/12/2010 - 9 -
Electric diagram
Caption
Features
Unit reference
A62608VCP A62613VCP A62615VCP A62619VCP
Number of GN2/1 600 W toughened glass plates 1 1 2 2
Number of GN1/1 300 W toughened glass plates 0 1 0 1
Heating top
Total power of the top (W) 600 900 1 200 1 500
Number of toughened glass plates, 330 W 1 1 2 2
Number of toughened glass plates, 200 W 0 1 0 1
Heating shelf
Shelf's total power (W) 330 530 660 860
Number of water resistant lighting, 40W 2 4 4 6
Lighting Lighting's total power (W) 80 160 160 240
Unit's total power (W) 1 010 1 590 2 020 2 600
gG (A) fuse calibre 6 8 10 12
Dd
Top's energy doser
Re
Shelf heating toughened glass
De
Shelf energy doser
S
Lighting on-off
L
Water-resistant lighting
Vd
Top's heating toughened glass light
Q
Fuse holder
Ve
Shelf heating toughened glass light
Rd
Top's heating toughened glass

USER MANUAL
Vauconsant SA, all rights reserved A622xx & E633xx -rev0-ENG, 2/12/2010 - 10 -
Spare parts
Unit capacity
Code Name 2GN GN 4GN 5GN
Accessories
02.1260 Plexiglas upper mirror support X X X X
02.1262 2 axis mirror link piece X X X
02.1264 3 axis mirror link piece X X X X
02.2320 Rose + side mirror mounting clips X X X X
03.0718 Rounded front mirror, 6mm lg 782mm thick X
03.0719 Rounded front mirror, 6mm lg 1,112mm thick X
03.0720 Rounded front mirror, 6mm lg 1,437mm thick X
03.0721 Rounded front mirror, 6mm lg 1,762mm thick X
03.1058 Cube-shaped front mirror, 6 mm thick, 567x782mm X
03.1060 Cube-shaped front mirror, 6 mm thick, 567x1112mm X
03.1070 Cube-shaped front mirror, 6 mm thick, 567x1437mm X
03.1072 Cube-shaped front mirror, 6 mm thick, 567x1762mm X
03.1074 Cube-shaped front mirror, 6 mm thick, 461x782mm X
03.1076 Cube-shaped front mirror, 6 mm thick, 461x1112mm X
03.1078 Cube-shaped front mirror, 6 mm thick, 461x1437mm X
03.1080 Cube-shaped front mirror, 6 mm thick, 461x1762mm X
03.1094 Cube-shaped side mirror, 6 mm thick X X X X
03.1096 Round side mirror, 6 mm thick X X X X
Toughened glass top and shelf
06.0925 GN2/1, 650x530mm C00W toughened glass heating plate X X X X
06.0927 GN1/1, 530x325mm 300W toughened glass heating plate X X
06.0930 643x318mm 330 W toughened glass heating plate X X X X
06.0932 318x318mm 200 W toughened glass heating plate X X
07.2210 Black silicone joint to stick the heating plates X X X X
Electric equipment
06.1070 Black PVC button, 43 mm X X X X
06.1505 Energy doser X X X X
06.1600 Orange light X X X X
Lighting
06.4760 40 W built-in lighting X X X X
06.1005 Orange switch light X X X X
This manual suits for next models
3
Table of contents
Other Vauconsant Commercial Food Equipment manuals
Popular Commercial Food Equipment manuals by other brands

Blue Seal
Blue Seal EF30 Installation & operation manual

Tecfrigo
Tecfrigo Snelle 400 GS installation instructions

Follett
Follett PFT Series Operation and maintenance manual

MEFE
MEFE CAT 206 PTR User manual and maintenance

Premier
Premier 900cl Product manua

Diamond
Diamond AL1TB/H2-R2 Installation, Operating and Maintenance Instruction

Salva
Salva IVERPAN FC-18 User instructions

Hussmann
Hussmann Rear Roll-in Dairy Installation & operation manual

Cornelius
Cornelius IDC PRO 255 Service manual

Moduline
Moduline HSH E Series Service manual

MINERVA OMEGA
MINERVA OMEGA DERBY 270 operating instructions

Cambro
Cambro IBSD37 Setup guide and user manual