Cleaning
Always take care to switch off the appliance with energy doser, thermostat and switch before
cleaning. This unit is not impermeable to water. Do not use a high pressure water jet to clean it
inside or out.
Every day:
•Metal surfaces:
Stainless steel should be cleaned with soapy warm water or a special product for high quality
metal surfaces. Never use abrasive sponges or scourers to avoid scratching the surface.
•Glass (breath shield):
All glass displays must be cleaned using a high quality glass cleaning product and clean cloth.
Never use abrasive sponges or scourers to avoid scratching the surface.
Diagnostic
Symptoms Possible causes Remedies
No electricity supply Check the general circuit breaker
Burnt fuse Check the fuse in the electric cabling
Light off, no heat
Faulty supply Check the supply cable
Defective contactor Replace the contactor
Cable disconnected or cut Check and test the electric input on the heating elements
Light on, no heat
Defective heating element Replace the heating element
Water inlet closed Check the water inlet
Water level poorly adjusted Re-adjust the water level see “Installation” section
The well is not
filled Defective solenoid valve Check that the solenoid valve works properly.
Bain-marie well
The water does
not stop running Water level poorly adjusted Re-adjust the water level see “Installation” section
No electricity supply Check the general circuit breaker
Burnt fuse Check the fuse in the electric cabling
Light off, no
heating or
ventilation Faulty supply Check the supply cable
Defective heating element Replace the heating element if necessary
Cable disconnected or cut Check and test the electric input on the heating elements
Light on, no heat
Defective safety thermostat Check and test the electric inlet on the safety thermostat.
Ventilator blocked or defective
Clean or replace the ventilator
Ventilated heat cupboard
Light on, no
ventilation Cable disconnected or cut Check and test the electric input on the ventilator
Halogen bulb burnt Replace the bulb with one of equivalent power
A halogen lamp
does not come
on Supply of this defective
halogen Check supply of halogen
No electricity supply Check the general circuit breaker
Burnt fuse Check the fuse in the electric cabling
Faulty supply Check the supply cable to the heating display
Halogen lighting:
None of the
halogen lights
come on
Defective switch Check the switch, replace it if necessary
NB
•
Bulbs should be replaced with bulbs of equivalent power. (see the Spare Parts section)
•Fuses should be replaced by gG fuses of the same calibre.