Veeder-Root TLS RF Troubleshooting guide

Manual No: 577013-877• Revision: A
TLS RF Wireless System
Quick Startup Guide
ALARM
WARNING
POWER
MonitoringSystem
TLS-300
(iii) Making Electrical Connections
1. Connect Mag-Probe/Mag-Sump-sensor wires to the left con-
nector and battery connections to the right connector.
2. Verify that green LED (Fig.12) flashes every 6 seconds fol-
lowed by the adjacent red LED.
3. Make sure the LED closest to J3 connector in RCVR also
flashes with an interval of 6 seconds or smaller. Make sure
both the RS485 Transmit & Receive LEDs flash.
4. Close the lid.
Make sure the rubber gasket (O-ring) is properly placed
on the inner lining of lid and on screws that secure lid.
Overtightening lid screws may result in plastic damage
resulting in water infiltration.
5. Similarly install all other transmitters.
PWR +IN -IN
GND
BATTERY
S3
S2S1
J4
J3
PROBE
Fig. 12
F. Connect TLS to TLS-RF
1. In this example, device output 1 (Item 1 Fig. 13) is
a Mag probe - Observe polarity.
2. In this example, device output 2 (Item 2) is a Mag
Sump Sensor - Observe polarity.
3. 0.5 inch (12.7mm) i.p.s. conduit (Item 3) to TLS
console.
4. Probe interface module (Item 4) in TLS console.
5. Smart Sensor interface module (Item 5) in TLS con-
sole.
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
PROBE 5
PROBE 4
PROBE 3
PROBE 2
PROBE 1
+
G
15V
G
REPEATER
RS-485
P
R
O
B
E /
TH
E
RM
IS
T
O
R
MA
XI
MUM
P
R
O
B
E
O
UT
P
UT
RAT
I
N
G
S
:
13V
DC
0.2
AM
P
PROBE / THERMISTOR INTERFACE MODULE
12341234
P
R
O
B
E
TH
E
RM
IS
T
O
R
+ + + +
15V
S
MART
SE
N
S
O
R
MA
XI
MUM
O
UT
P
UT
RAT
I
N
G
S
13V
DC
0.2
AM
P
+ + + + + + + +
1 2 3 4 5 6 7 8
SMART SENSOR INTERFACE MODULE
1
4
5
3
2
Fig. 13
G. Repeater Installation
Install repeater with clear line of sight to maximum number of transmitters as possible. You can give
power to repeater (Item 1 Figs. 14/15) either:
REPEATER
J4
S3
S2 S1
J3
RS-485
GND
+15V
+15v
+
GND
TRANSMIT
RECEIVE
PWR
REPEATER
J4
S3
S2 S1
J3
RS-485
GND
+15V
+15v
+
GND
TRANSMIT
RECEIVE
PWR
2
1
Fig. 14
REPEATER
J4
S3
S2 S1
J3
RS-485
GND
+15V
+15v
+
GND
TRANSMIT
RECEIVE
PWR
+15 Vdc
Gnd
ACDC
1
2
Fig. 15
• From Receiver (Item 2 Fig. 14), or
• From a 15V/100mA power adapter (Item 2 Fig. 15)
H. Installation Verification
Select the Diagnostic Mode in the TLS Console and go to In-Tank Diagnostic Function. Verify that all
Mag probe/Mag Sump Sensor serial numbers correctly match their installed locations.

A. Install TLS-RF:
1. Mount TLS-RF unit indoors on 4 holes separated vertically by 5.7 inches/
145 mm and horizontally by 6.7 inches/170mm and using screws up to
0.187 inch/4.7mm diameter (dimensions shown in Fig. 1 are maximums).
2. Install 0.5 inch/12.7mm metal conduit on upper knockout on TLS-RF and
15A circuit breaker in power panel, or a 5A switched fuse spur with neon
indication.
3. Turn off all the 8 DIP switches inside TLS-RF.
4. Make arrow in rotary switch point to “1”.
1000mm
39 inches
1500mm
59 inches
1. In TLS-RF connect 1 end of the RS-485
cable (Belden #3107A or equiv.) to RS-485
connectors - one twisted pair connects to
terminals (- & +) and the second twisted
pair connects to terminals (+15 & G).
2. Connect the shield of the RS-485 cable to
the ground lug.
3. Run the RS-485 cable to Receiver, maxi-
mum length 250 feet/76 m.
4. In Receiver, turn off all 16 DIP switches
marked as S1 & S2.
5. Connect 2nd end of RS-485 cable to RS-
485 connectors as shown.
B. Install RCVR
+
G
G
15V
REPEATER
RS-485
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
15V
S3
S
2S1
J3
RS-485
GND
+15V
+15v
+
GND
P
TLS-RF Receiver
C. Connect Power to TLS-RF, check PWR LED inside RCVR
1. From an independent 24 hour power supply at the distri-
bution panel, run three 2.5 mm2 (minimum) standard color
coded wires (item 1 in Fig. 4); two for ac power and one
for earth to the fused spur.
2. Run one #12AWG (4 mm2) barrier ground wire (color
coded green/ yellow) from the earth bus bar at the distri-
bution panel direct to the console location. Leave at least
1 meter of free cable for connection to the console.
3. Turn on power.
4. Near the left-lower corner inside TLS-RF, verify that
POWER LED is on and RX-485 TX LED is flashing at a
fast rate (10 times a second).
5. Near the top-central part inside Receiver, verify that PWR
LED is ON and RECEIVE LED is also flashing at the
same rate. Else check RS-485 wire connection.
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
PROBE 8
PROBE 7
PROBE 6
PROBE 5
PROBE 4
PROBE 3
PROBE 2
PROBE 1
+
G
G
15V
AC
INPUT
REPEATER
RS-485
15V
1
D. Set Station ID Inside Receiver
Watch red LED, D8, between the 2 connectors, J4 & J3, for
more than 2 minutes, it should not flash (even once). If it does,
meaning it is receiving packets from nearby station, change to
another station ID on S2 DIP switches (see example settings
below). Note down Station ID for use in transmitter set-up.
REPEATER
J4 J3
RS-485
GND
+15V
+15v
+
GND
Receiver
ID:0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Fig. 1
Fig. 2 Fig. 3
Fig. 4
Fig. 5
E. Install XMTR
1. Set the station ID, same as in receiver, on S2 DIP switches inside transmitter. Make sure switches 1
through 4 are turned off unless you want to use non-standard mode (refer site-prep manual).
2. Set unique Device ID for every transmitter on S1 DIP switches (4-8) inside transmitter (see below):
S1
3. Mount transmitter & battery pack.
Antenna is a sensitive part, please don’t try to rotate, unscrew or bend it and handle carefully. For
best communication quality, transmitter antenna should be horizontal and point in the direction of
receiver.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1
2
1
1
(i). Installing Transmitter on Mag Probe Riser
1. Bolt appropriate size hangers to Battery pack support bracket as
shown using 1/4 x 20 x 0.5” (13 mm) hex head bolt/nuts (Item 1
Fig 6) - 2 places.
2. Loosely attach conduit hanger tightening bolts using 1/4 x 20 x 1.25
inch (32 mm) hex head bolt/nuts (Item 2 Fig. 6) – 1 each hanger.
3. Attach 2 small clamps to bracket as shown using two #10 x 0.5 inch
(M5x0.8 x 12.7) screws and nuts (Item 1 Fig. 7).
4. Attach 2 small clamps to back of transmitter as shown using #10 x
0.5 inch (M5x0.8 x 12.7) taptite screw (Item 1 Fig. 8) - 2 places.
(Go to iii).
(ii). Installing Transmitter in Dispenser Sump
1. Transmitter (Item 1 Fig. 10) at-
taches to battery support
bracket using 2-#10 x 0.5 inch
(M5x0.8 x 12.7) taptite screws
(Item 2 Fig. 10).
2. Get 1x 6 inch (25 x 152mm)
slotted flat bar and two 0.25 x
3 inch (13 x 76mm) bolts (Item
1 Fig. 11) from kit and clamp
battery support bracket to
square tubing support.
(Go to iii).
2
1
Caution:
Battery
Connection
1
Fig. 6
Fig. 8
Fig. 7
Fig. 9
Fig. 10
Fig. 11
Caution:
Battery
Connection
Caution:
Battery
Connection
Do not reset Dip Switches 1 - 3
Do not reset Dip Switches 1 - 3
Do not reset Dip Switches 1 - 3
Do not reset Dip Switches 1 - 3
Popular Diagnostic Equipment manuals by other brands

NEXIQ Technologies
NEXIQ Technologies USB-Link 3 Wireless Installation and setup manual

Agilent Technologies
Agilent Technologies 5DX Operator instructions

Hella Gutmann
Hella Gutmann 9XS 861 736-011 Installation instruction

Autel
Autel MaxiLink ML629 Quick reference guide

ELM
ELM EcoPro2 Operation manual

Haldex
Haldex EB+ Info Centre Operator's guide