Vega VEGAPULS 6X User manual

Operating Instructions
Radar sensor for continuous level
measurement of liquids
VEGAPULS 6X
Two-wire 4 … 20 mA/HART
Document ID: 66101

2
Contents
VEGAPULS 6X • Two-wire 4 … 20 mA/HART
66101-EN-211011
Contents
1 About this document ............................................................................................................... 4
1.1 Function ........................................................................................................................... 4
1.2 Target group ..................................................................................................................... 4
1.3 Symbols used................................................................................................................... 4
2 For your safety ......................................................................................................................... 5
2.1 Authorised personnel ....................................................................................................... 5
2.2 Appropriate use................................................................................................................ 5
2.3 Warning about incorrect use............................................................................................. 5
2.4 General safety instructions............................................................................................... 5
2.5 Modes for worldwide use.................................................................................................. 6
2.6 Installation and operation in the USA and Canada ........................................................... 6
3 Product description ................................................................................................................. 7
3.1 Conguration.................................................................................................................... 7
3.2 Principle of operation........................................................................................................ 8
3.3 Packaging, transport and storage..................................................................................... 9
3.4 Accessories.................................................................................................................... 10
4 Mounting................................................................................................................................. 11
4.1 General instructions ....................................................................................................... 11
4.2 Housing features ............................................................................................................ 11
4.3 Mounting preparations, mounting strap.......................................................................... 13
4.4 Mounting versions, plastic horn antenna ........................................................................ 15
4.5 Mounting instructions ..................................................................................................... 17
4.6 Measuring rigs - bypass ................................................................................................. 35
4.7 Measurement setup - Flow............................................................................................. 36
5 Connecting to power supply................................................................................................. 39
5.1 Preparing the connection ............................................................................................... 39
5.2 Connecting..................................................................................................................... 40
5.3 Wiring plan, single chamber housing.............................................................................. 41
5.4 Wiring plan, double chamber housing ............................................................................ 42
5.5 Wiring plan - version IP66/IP68, 1 bar ............................................................................ 43
5.6 Switch-on phase............................................................................................................. 44
6 IT-Security and access protection........................................................................................ 45
6.1 IT-Security ...................................................................................................................... 45
6.2 Bluetooth radio interface ................................................................................................ 46
6.3 Protection of the parameterization.................................................................................. 46
6.4 Storing the codes in myVEGA........................................................................................ 47
7 Set up with the display and adjustment module ................................................................ 48
7.1 Insert display and adjustment module............................................................................ 48
7.2 Adjustment system......................................................................................................... 49
7.3 Measured value indication - Selection of national language........................................... 50
7.4 Parameterization ............................................................................................................ 51
7.5 Saving the parameterisation data................................................................................... 70
8 Setup with PACTware............................................................................................................. 71
8.1 Connect the PC.............................................................................................................. 71
8.2 Parameter adjustment with PACTware............................................................................ 71

3
Contents
VEGAPULS 6X • Two-wire 4 … 20 mA/HART
66101-EN-211011
8.3 Saving the parameterisation data................................................................................... 73
9 Menu overview ....................................................................................................................... 74
9.1 Display and adjustment unit (on site).............................................................................. 74
9.2 VEGA Tools-App (Bluetooth) and DTM (on-site, signal line, Bluetooth).......................... 78
9.3 Expert settings ............................................................................................................... 83
10 Set up with other systems .................................................................................................... 86
10.1 DD adjustment programs ............................................................................................... 86
10.2 Field Communicator 375, 475 ........................................................................................ 86
11 Diagnosis, asset management and service ........................................................................ 87
11.1 Maintenance .................................................................................................................. 87
11.2 Measured value and event memory ............................................................................... 87
11.3 Asset Management function........................................................................................... 88
11.4 Rectify faults................................................................................................................... 91
11.5 Exchanging the electronics module................................................................................ 95
11.6 Software update ............................................................................................................. 96
11.7 How to proceed if a repair is necessary.......................................................................... 97
12 Dismount................................................................................................................................. 98
12.1 Dismounting steps.......................................................................................................... 98
12.2 Disposal ......................................................................................................................... 98
13 Certicatesandapprovals(inpreparation) ........................................................................ 99
13.1 Radio licenses................................................................................................................ 99
13.2 Approvals for Ex areas ................................................................................................... 99
13.3 Approvalsasoverllprotection....................................................................................... 99
13.4 Foodandpharmaceuticalcerticates............................................................................. 99
13.5 EU conformity................................................................................................................. 99
13.6 NAMUR recommendations ............................................................................................ 99
13.7 Environment management system............................................................................... 100
14 Supplement .......................................................................................................................... 101
14.1 Technical data .............................................................................................................. 101
14.2 Radio astronomy stations............................................................................................. 117
14.3 Dimensions .................................................................................................................. 117
14.4 Industrial property rights............................................................................................... 130
14.5 Licensing information for open source software ........................................................... 130
14.6 Trademark .................................................................................................................... 130
Safety instructions for Ex areas
TakenoteoftheExspecicsafetyinstructionsforExapplications.
These instructions are attached as documents to each instrument
with Ex approval and are part of the operating instructions.
Editing status: 2021-09-27

4
1 About this document
VEGAPULS 6X • Two-wire 4 … 20 mA/HART
66101-EN-211011
1 About this document
1.1 Function
This instruction provides all the information you need for mounting,
connection and setup as well as important instructions for mainte-
nance,faultrectication,theexchangeofpartsandthesafetyofthe
user. Please read this information before putting the instrument into
operation and keep this manual accessible in the immediate vicinity
of the device.
1.2 Target group
This operating instructions manual is directed to trained personnel.
Thecontentsofthismanualmustbemadeavailabletothequalied
personnel and implemented.
1.3 Symbols used
Document ID
This symbol on the front page of this instruction refers to the Docu-
ment ID. By entering the Document ID on www.vega.com you will
reach the document download.
Information, note, tip: This symbol indicates helpful additional infor-
mation and tips for successful work.
Note: This symbol indicates notes to prevent failures, malfunctions,
damage to devices or plants.
Caution: Non-observance of the information marked with this symbol
may result in personal injury.
Warning: Non-observance of the information marked with this symbol
may result in serious or fatal personal injury.
Danger: Non-observance of the information marked with this symbol
results in serious or fatal personal injury.
Ex applications
This symbol indicates special instructions for Ex applications.
• List
The dot set in front indicates a list with no implied sequence.
1 Sequence of actions
Numbers set in front indicate successive steps in a procedure.
Battery disposal
This symbol indicates special information about the disposal of bat-
teries and accumulators.

5
2 For your safety
VEGAPULS 6X • Two-wire 4 … 20 mA/HART
66101-EN-211011
2 For your safety
2.1 Authorised personnel
All operations described in this documentation must be carried out
onlybytrained,qualiedpersonnelauthorisedbytheplantoperator.
During work on and with the device, the required personal protective
equipment must always be worn.
2.2 Appropriate use
VEGAPULS 6X is a sensor for continuous level measurement.
Youcannddetailedinformationabouttheareaofapplicationin
chapter " Product description".
Operational reliability is ensured only if the instrument is properly
usedaccordingtothespecicationsintheoperatinginstructions
manual as well as possible supplementary instructions.
2.3 Warning about incorrect use
Inappropriate or incorrect use of this product can give rise to applica-
tion-specichazards,e.g.vesseloverllthroughincorrectmounting
or adjustment. Damage to property and persons or environmental
contamination can result. Also, the protective characteristics of the
instrument can be impaired.
2.4 General safety instructions
This is a state-of-the-art instrument complying with all prevailing
regulations and directives. The instrument must only be operated in a
technicallyawlessandreliablecondition.Theoperatorisresponsi-
ble for the trouble-free operation of the instrument. When measuring
aggressive or corrosive media that can cause a dangerous situation
if the instrument malfunctions, the operator has to implement suitable
measures to make sure the instrument is functioning properly.
The safety instructions in this operating instructions manual, the na-
tional installation standards as well as the valid safety regulations and
accident prevention rules must be observed by the user.
For safety and warranty reasons, any invasive work on the device
beyond that described in the operating instructions manual may be
carried out only by personnel authorised by the manufacturer. Arbi-
traryconversionsormodicationsareexplicitlyforbidden.Forsafety
reasons,onlytheaccessoryspeciedbythemanufacturermustbe
used.
To avoid any danger, the safety approval markings and safety tips on
the device must also be observed.
The low transmitting power of the radar sensor is far below the inter-
nationally approved limits. No health impairments are to be expected
with intended use.The band range of the measuring frequency can
be found in chapter " Technical data".

6
2 For your safety
VEGAPULS 6X • Two-wire 4 … 20 mA/HART
66101-EN-211011
2.5 Modes for worldwide use
Countryspecicsettingsfortheradarsignalsaredeterminedviathe
operating mode.The operating mode must be set in the operating
menu via the respective adjustment tool at the beginning of the setup
(see chapter " Setup" resp. " Menu overview".
Caution:
Operating the device without selecting the appropriate country group
constitutes a violation of the regulations of the radio approvals of the
respective country.
Further information can be found in the document " Regulations for
radar level measuring instruments with radio licenses" on our home-
page.
2.6 Installation and operation in the USA and
Canada
This information is only valid for USA and Canada. Hence the follow-
ing text is only available in the English language.
Installations in the US shall comply with the relevant requirements of
the National Electrical Code (ANSI/NFPA 70).
Installations in Canada shall comply with the relevant requirements of
the Canadian Electrical Code
A Class 2 power supply unit has to be used for the installation in the
USA and Canada.

7
3 Product description
VEGAPULS 6X • Two-wire 4 … 20 mA/HART
66101-EN-211011
3 Product description
3.1 Conguration
The scope of delivery encompasses:
• Radar sensor, possibly with accessories
– Discsprings(forangeversionwithplasticplating)1)
– Hexagon socket wrench (for instruments with swivel holder)
– Optional accessory
• Information sheet " PINs and Codes" (in versions SIL, IT-Security,
Bluetooth) with:
– Bluetooth access code
• Information sheet " Access protection" with:
– Bluetooth access code
– Emergency Bluetooth unlock code
– Emergency device code
• Documentation
– Quick setup guide VEGAPULS 6X
– Instructions for optional instrument components
– Ex-specic"Safety instructions" (with Ex versions)
– Radio licenses
– Ifnecessary,furthercerticates
Note:
Optional instrument features are also described in this operating
instructions manual.The respective scope of delivery results from the
orderspecication.
This operating instructions manual applies to the following instrument
versions:
• Hardware version from 1.0.0
• Software version from 1.0.0
Thetypelabelcontainsthemostimportantdataforidenticationand
use of the instrument:
Scope of delivery
Scope of this operating
instructions
Type label
1) Use see chapter "Mounting instructions, sealing to the process"

8
3 Product description
VEGAPULS 6X • Two-wire 4 … 20 mA/HART
66101-EN-211011
VEGAPULS64 GEN2
PS64.2AXXXXXXATCYRMA
PS64W Gen 2, FCC ID: IC:
5
4
6
3
2
1
12...35VDC
30m
4...20mA HART two wire
123456
Fig. 1: Layout of the type label (example)
1 Instrument type, product code
2 Field for approvals
3 Technical data
4 Data matrix code for VEGA Tools app
5 Reminder to observe the instrument documentation
6 Bluetooth access code
The type label contains the serial number of the instrument. With it
youcanndthefollowinginstrumentdataonourhomepage:
• Product code (HTML)
• Delivery date (HTML)
• Order-specicinstrumentfeatures(HTML)
• Operating instructions and quick setup guide at the time of ship-
ment (PDF)
• Testcerticate(PDF)-optional
Move to " www.vega.com"andenterinthesearcheldtheserial
number of your instrument.
Alternatively, you can access the data via your smartphone:
• Download the VEGA Tools app from the " Apple App Store" or the
" Google Play Store"
• Scan the QR-code on the type label of the device or
• Enter the serial number manually in the app
3.2 Principle of operation
The VEGAPULS 6X is a radar sensor for continuous level measure-
mentofliquidsaswellasbulksolidsunderdierentprocesscondi-
tions.
Thesmallthreadedttingsoerparticularadvantagesinsmalltanks
or tight mounting spaces.The very good signal focusing ensures the
use in vessels with many installations such as stirrers and heating
spirals.
Theangeconnectionsareidealforlevelmeasurementinveryhigh
silos, large bunkers and segmented vessels.The very good signal
focussing ensures easy setup and reliable measurement.
Theinstrumentisavailablewithdierentantennasystems:
Serial number - Instru-
ment search
Application area
Antenna systems

9
3 Product description
VEGAPULS 6X • Two-wire 4 … 20 mA/HART
66101-EN-211011
1 2 3 4
Fig. 2: Antenna systems VEGAPULS 6X
1 Plastic horn antenna
2 Thread with integrated antenna system
3 Flange with plastic plating
4 Flange with lens antenna
The instrument emits a continuous, frequency-modulated radar signal
throughitsantenna.Theemittedsignalisreectedbythemedium
andreceivedbytheantennaasanechowithmodiedfrequency.The
frequency change is proportional to the distance and is converted into
the level.
3.3 Packaging, transport and storage
Your instrument was protected by packaging during transport. Its
capacity to handle normal loads during transport is assured by a test
based on ISO 4180.
The packaging consists of environment-friendly, recyclable card-
board. For special versions, PE foam or PE foil is also used. Dispose
of the packaging material via specialised recycling companies.
Transport must be carried out in due consideration of the notes on the
transport packaging. Nonobservance of these instructions can cause
damage to the device.
The delivery must be checked for completeness and possible transit
damage immediately at receipt. Ascertained transit damage or con-
cealed defects must be appropriately dealt with.
Up to the time of installation, the packages must be left closed and
stored according to the orientation and storage markings on the
outside.
Unless otherwise indicated, the packages must be stored only under
the following conditions:
• Not in the open
• Dry and dust free
• Not exposed to corrosive media
• Protected against solar radiation
• Avoiding mechanical shock and vibration
Functional principle
Packaging
Transport
Transport inspection
Storage

10
3 Product description
VEGAPULS 6X • Two-wire 4 … 20 mA/HART
66101-EN-211011
• Storage and transport temperature see chapter " Supplement -
Technical data - Ambient conditions"
• Relative humidity 20 … 85 %
With instrument weights of more than 18 kg (39.68 lbs) suitable and
approved equipment must be used for lifting and carrying.
3.4 Accessories
The instructions for the listed accessories can be found in the down-
load area on our homepage.
The display and adjustment module is used for measured value indi-
cation, adjustment and diagnosis.
The integrated Bluetooth module (optional) enables wireless adjust-
ment via standard adjustment devices.
The interface adapter VEGACONNECT enables the connection of
communication-capable instruments to the USB interface of a PC.
The VEGADIS 81 is an external display and adjustment unit for VEGA
plics®sensors.
VEGADIS 82 is suitable for measured value indication and adjustment
of sensors with HART protocol. It is looped into the 4 … 20 mA/HART
signal cable.
The PLICSMOBILE T81 is an external GSM/GPRS/UMTS radio unit
for transmission of measured values and for remote parameter adjust-
ment of HART sensors.
PLICSMOBILE 81 is an internal GSM/GPRS/UMTS radio unit for
HART sensors for transmitting measured values and for remote
parameterization.
Welded sockets are used to connect the devices to the process,
threaded and hygienic adapters for easy adaptation of devices with
standardthreadedttings,e.g.tohygienicconnectionsonthepro-
cess side.
Screwedangesareavailableindierentversionsaccordingtothe
following standards: DIN 2501, EN 1092-1, BS 10, ASME B 16.5,
JIS B 2210-1984, GOST 12821-80.
Storage and transport
temperature
Lifting and carrying
PLICSCOM
VEGACONNECT
VEGADIS 81
VEGADIS 82
PLICSMOBILE T81
PLICSMOBILE 81
Welded socket, threaded
and hygienic adapter
Flanges

11
4 Mounting
VEGAPULS 6X • Two-wire 4 … 20 mA/HART
66101-EN-211011
4 Mounting
4.1 General instructions
Protect your instrument against moisture ingress through the following
measures:
• Use a suitable connection cable (see chapter " Connecting to
power supply")
• Tighten the cable gland or plug connector
• Lead the connection cable downward in front of the cable entry or
plug connector
This applies mainly to outdoor installations, in areas where high
humidity is expected (e.g. through cleaning processes) and on cooled
or heated vessels.
Note:
Make sure that during installation or maintenance no moisture or dirt
can get inside the instrument.
To maintain the housing protection, make sure that the housing lid is
closed during operation and locked, if necessary.
Note:
For safety reasons, the instrument must only be operated within the
permissibleprocessconditions.Youcannddetailedinformationon
the process conditions in chapter " Technical data" of the operating
instructions or on the type label.
Hence make sure before mounting that all parts of the instrument ex-
posed to the process are suitable for the existing process conditions.
These are mainly:
• Active measuring component
• Processtting
• Process seal
Process conditions in particular are:
• Process pressure
• Process temperature
• Chemical properties of the medium
• Abrasionandmechanicalinuences
As a standard feature, the VEGAPULS 6X is separate from the pro-
cess through its plastic antenna encapsulation.
Optionally, the instrument is available with a Second Line of Defense
(SLOD), a second process separation. It is located as gas-tight
leadthrough between the process component and the electronics.
This means additional safety against penetration of the medium fron
the process into the instrument.
4.2 Housing features
Thelterelementinthehousingisusedforventilationofthehousing.
Protection against mois-
ture
Process conditions
Second Line of Defense
Filter element

12
4 Mounting
VEGAPULS 6X • Two-wire 4 … 20 mA/HART
66101-EN-211011
Foreectiveventilation,thelterelementmustalwaysbefreeof
deposits.Therefore,mountthedevicesothatthelterelementis
protected against deposits.
Caution:
Donotuseahigh-pressurecleaner.Thelterelementcouldbedam-
aged, which would allow moisture into the housing.
2 3 4
1
1
11
1
6
5
Fig. 3: Position of the lter element depending on housing
1 Filter element
2 Plastic single chamber
3 Aluminium single chamber, stainless steel single chamber (precision cast-
ing)
4 Stainless steel single chamber (electropolished)
5 Plastic double chamber
6 Aluminium, stainless steel double chamber housing (precision casting)
For devices in protection class IP66/IP68 (1 bar), ventilation is pro-
videdbyacapillaryinthexedcable.Inthesedevices,ablindplugis
installedinthehousinginsteadofthelterelement.
The housing of VEGAPULS 6X can be rotated completely through
360°.This allows the display to be read optimally and the device to be
aligned for easy cable insertion. 2)
Depending on the version and housing material, the locking screw on
the housing neck must be loosened.The housing can then be turned
to the correct position. As soon as the this position is reached, tighten
the locking screw. Use an hexagon spanner size 3.
Housing orientation
2) No limitation by a rotation stop

13
4 Mounting
VEGAPULS 6X • Two-wire 4 … 20 mA/HART
66101-EN-211011
11
Fig. 4: Position of the locking screw depending on housing
1 Locking screw
2 Aluminium single chamber, stainless steel single chamber (precision cast-
ing)
3 Aluminium, stainless steel double chamber housing (precision casting)
Information:
For the housing orientation, observe the information on polarization in
chapter " Mounting instructions".
The housing lid on housings made of aluminium and stainless steel
(ne-cast)canbesecuredbyascrew.Thisprotectstheinstrument
from unauthorised opening of the lid.
The locking screw has two holes drilled through the head which allow
it also to be sealed.
32
11
Fig. 5: Position of the safety screw depending on housing
1 Safety screw
2 Single chamber housing
3 Double chamber housing
4.3 Mounting preparations, mounting strap
The mounting strap is supplied unassembled (optionally) as acces-
sory part of the plastic horn antenna and must be screwed to the
sensor before setup with three hexagon socket screws M5 x 10 and
spring washers. Max. torque, see chapter " Technical data". Required
tools: Allen wrench size 4.
Therearetwodierentvariantsofscrewingthestraptothesensor,
see following illustration:
Cover catch

14
4 Mounting
VEGAPULS 6X • Two-wire 4 … 20 mA/HART
66101-EN-211011
1 2
Fig. 6: Mounting strap for screwing to the sensor
1 For angle of inclination in steps
2 For angle of inclination, innitely variable
Depending on the selected variant, the sensor can be rotated in the
strap:
• Single chamber housing
– Angle of inclination in three steps 0°, 90° and 180°
– Angleofinclination180°,innitelyvariable
• Double chamber housing
– Angle of inclination in two steps 0° and 90°
– Angleofinclination90°,innitelyvariable
Fig. 7: Adjustment of the angle of inclination
Fig. 8: Turning by fastening in the centre

15
4 Mounting
VEGAPULS 6X • Two-wire 4 … 20 mA/HART
66101-EN-211011
4.4 Mounting versions, plastic horn antenna
The optional mounting strap allows simple mounting of the instrument
on a wall, ceiling or boom. Especially in the case of open vessels, this
isasimpleandeectivewaytoalignthesensortothesurfaceofthe
bulk solid material.
The following versions are available:
• Length 300 mm
• Length 170 mm
The instrument is normally mounted vertically with a bracket on the
ceiling.
This allows swivelling the sensor up to 180° for optimal orientation
and rotating for optimal connection.
Fig. 9: Ceiling mounting via the mounting strap with length 300 mm
As an alternative the strap mounting is carried out horizontally or
obliquely.
> 200 mm
(7.87")
Fig. 10: Wall mounting horizontally via the mounting strap with length 170 mm
Mounting strap
Mounting strap - Ceiling
mounting
Mounting strap - Wall
mounting

16
4 Mounting
VEGAPULS 6X • Two-wire 4 … 20 mA/HART
66101-EN-211011
Fig. 11: Wall mounting with inclined wall via the mounting strap with length
300 mm
Two versions are available for mounting the instrument on a nozzle:
• Combicompressionange
• Adapterange
Combicompressionange
Thecombicompressionangeissuitablefordierentvesselanges
DN 80, ASME 3" and JIS 80. It comes not sealed against the radar
sensorandcanthusonlybeusedunpressurized.Itcanberetrotted
oninstrumentswithsinglechamberhousing,retrottingtoadouble
chamber housing is not possible.
1
Fig. 12: Combi compression ange
1 Combi compression ange
Adapterange
TheadapterangeisavailablefromDN100,ASME4"andJIS100.It
is permanently connected with the radar sensor and sealed.
Flange

17
4 Mounting
VEGAPULS 6X • Two-wire 4 … 20 mA/HART
66101-EN-211011
3
1
2
Fig. 13: Adapter ange
1 Connection screw
2 Adapter ange
3 Process seal
4.5 Mounting instructions
Radar sensors for level measurement emit electromagnetic waves.
The polarization is the direction of the electrical component of these
waves.
The polarization direction is marked by a nose on the housing, see
following drawing:
1
Fig. 14: Position of the polarisation
1 Nose for marking the direction of polarisation
Note:
Turningthehousingchangesthepolarisationandthustheeectof
false echoes on the measured value.
In order to avoid a change in the metrological properties, observe
the position of the polarisation during installation or in the case of
subsequent changes.
When mounting the device, keep a distance of at least 200 mm
(7.874 in) from the vessel wall. If the device is installed in the center
of dished or round vessel tops, multiple echoes can arise. However,
these can be suppressed by an appropriate adjustment (see chapter
" Setup").
If you cannot maintain this distance, you should carry out a false
signal suppression during setup. This applies particularly if buildup on
Polarisation
Mounting position -
liquids

18
4 Mounting
VEGAPULS 6X • Two-wire 4 … 20 mA/HART
66101-EN-211011
the vessel wall is expected. In such cases, we recommend repeating
the false signal suppression at a later date with existing buildup.
> 200 mm
(7.87
")
Fig. 15: Mounting of the radar sensor on round vessel tops
In vessels with conical bottom it can be advantageous to mount the
device in the centre of the vessel, as measurement is then possible
down to the bottom.
Fig. 16: Mounting of the radar sensor on vessels with conical bottom
Mount the instrument at least 200 mm (7.874 in) away from the vessel
wall.
200 mm
(7.87
")
Fig. 17: Mounting the radar sensor on the vessel top
If you cannot maintain this distance, you should carry out a false
signal suppression during setup. This applies particularly if buildup on
Mounting position - bulk
solids

19
4 Mounting
VEGAPULS 6X • Two-wire 4 … 20 mA/HART
66101-EN-211011
the vessel wall is expected. In such cases, we recommend repeating
the false signal suppression at a later date with existing buildup.
The measuring range of VEGAPULS 6X begins physically at the end
of the antenna.The min./max. adjustment, however, begins at the
referenceplane.Thereferenceplaneisdierentdependingonthe
sensor version.
• Plastic horn antenna: The reference plane is the sealing surface
on the lower edge
• Thread with integrated antenna system: The reference plane is
the sealing surface at the bottom of the hexagon
• Flange with plastic plating: The reference plane is the lower
sideoftheangeplating
• Hygienictting: The reference plane is the highest contact point
betweensensorprocessttingandweldedsocket
• Flange with lens antenna: The reference plane is the lower side
oftheange
The following graphic shows the position of the reference plane with
dierentsensorversions.
1
2
1
1
1
1
3 4
56
Fig. 18: Position of the reference plane
1 Reference plane
2 Plastic horn antenna
3 Threaded ttings
4 Flange connections
5 Hygienic ttings
6 Flange with lens antenna
Donotmounttheinstrumentsinorabovethellingstream.Makesure
thatyoudetectthemediumsurface,nottheinowingproduct.
Reference plane
Inowingmedium-liq-
uids

20
4 Mounting
VEGAPULS 6X • Two-wire 4 … 20 mA/HART
66101-EN-211011
Fig. 19: Mounting of the radar sensor with inowing medium
Theinstrumentshouldnotbemountedtooclosetotheinowing
medium, as the radar signal could be disrupted.
Silowithllingfromtop
Theoptimalmountingpositionisoppositethellingaperture.Toavoid
heavysoiling,thedistancetoanylterordustexhaustershouldbeas
large as possible.
Fig. 20: Mounting of the radar sensor with inowing medium
Silowithlaterallling
Inbulksolidssiloswithlateralpneumaticllingtheinstrumentshould
notbemountedabovethellingstream,astheradarsignalwillbe
disrupted.Theoptimalmountingpositionistothesideofthelling
aperture.Toavoidheavysoiling,thedistancetoanylterordust
exhauster should be as large as possible.
Inowingmedium-bulk
solids
Other manuals for VEGAPULS 6X
9
Table of contents
Other Vega Accessories manuals

Vega
Vega VEGAPULS 62 User manual

Vega
Vega VEGAPULS 66 User manual

Vega
Vega vegaflex 83 User manual

Vega
Vega VEGABAR 82 User manual

Vega
Vega vegaflex 83 User manual

Vega
Vega VEGASON 63 User manual

Vega
Vega VEGAFLEX 86 User manual

Vega
Vega VEGAPULS 67 User manual

Vega
Vega VEGAFLEX 82 User manual

Vega
Vega VEGABAR 38 User manual

Vega
Vega VEGAFLEX 86 User manual

Vega
Vega DP-1 User manual

Vega
Vega vegaflex 83 User manual

Vega
Vega POINTRAC 31 User manual

Vega
Vega VEGAPULS Air 23 User manual

Vega
Vega VEGACAP 27 User manual

Vega
Vega VEGASON 61 User manual

Vega
Vega VEGAPULS 6X User manual

Vega
Vega VEGAFLEX 81 User manual

Vega
Vega VEGAPULS C 22 User manual