Vega VEGALOG 571 User manual

Level and Pressure
in out
Operating Instructions
VEGALOG 571
on on
on
PC
on
VEGALOG
1
2
3
4
5
6
7
8
9
10
571 CPU VEGALOG
571 EA VEGALOG
571 EV VEGALOG
571 AR
!!!!

2VEGALOG 571
Contents
Contents
Safety information ........................................................................ 3
Note Ex-area ................................................................................ 3
1 Product description
1.1 Function and configuration .................................................. 4
1.2 Software ................................................................................ 5
1.3 Module card types ............................................................... 6
1.4 Technical data .................................................................... 10
1.5 Dimensions ......................................................................... 18
1.6 Applications ........................................................................ 19
2 Mounting
2.1 Carrier ................................................................................. 25
2.2 Mounting in carrier ............................................................. 25
2.3 Selection of the plug position ............................................ 26
2.4 Coding ................................................................................ 26
2.5 Co-ordination ...................................................................... 27
3 Electrical connection
3.1 General connection instructions ........................................ 28
3.2 Coupling of the carriers ..................................................... 29
3.3 Interface cable PC - VEGALOG ......................................... 29
3.4 Connection plans ............................................................... 30
3.5 Connection instructions for VBUS-sensors ....................... 32
3.6 Installation example for VBUS-sensors ............................. 34
3.7 Screening of the VBUS-line ................................................ 34
3.8 Galvanic isolation ............................................................... 35
3.9 Additional instructions for Ex-applications ........................ 35

VEGALOG 571 3
Contents
Safety information
The described module must only be installed
and operated as described in these operating
instructions. Please note that other action can
cause damage for which VEGA does not take
responsibility.
NoteEx-area
Please note the approval documents attached
(yellow binder), and especially the included
safety data sheet.
4 Set-up
4.1 Indicating and adjustment elements ................................. 38
4.2 Adjustment software VVO .................................................. 38
5 Diagnosis
5.1 Maintenance ....................................................................... 44
5.2 Status indication ................................................................. 44
5.3 Failure removal ................................................................... 44
5.4 Repair ................................................................................. 44
6 Supplement
6.1 Visualisation ........................................................................ 45
6.2 Communication .................................................................. 45
6.3 Components for configuration ........................................... 46

4VEGALOG 571
Product description
1 Product description
1.1 Function and configuration
VEGALOG 571 is a modular processing
system for manifold applications in, for exam-
ple
- level measurement
- density measurement
- gauge measurement
- level detection
- process pressure measurement
- differential pressure measurement
- etc.
Suiting the application and meeting the indi-
vidual requirements, VEGALOG 571 is com-
posed of several module cards. One
CPU-card and peripheral cards are available
which are inserted into a carrier.
Function
VEGALOG 571 powers the connected sen-
sors and processes their analogue or digital
measuring signals or switching commands.
The peripheral cards take over the supply,
as well as the preparation of the measuring
signal for processing. The processing is
made in the CPU via special software con-
sisting of functional components (FB), input
components (EB) and output components
(AB). The input components receive the
measuring signals, the output components
provide them via the hardware outputs of the
peripheral cards or the CPU:
- as current signal 0/4 … 20 mA
- as voltage signal 0/2 … 10 V
- as relay/transistor contact
- as digital signal (RS 232-interface)
Adjustment surface
The adjustment of VEGALOG 571 is made by
a PC connected via an RS 232-cable to the
PC-interface of the CPU. The adjustment
software VEGA Visual Operating (VVO) is
installed under WindowsTM and enables the
easy configuration of measuring systems, as
well as the parameter adjustment of con-
nected VEGA-sensors. VVO offers a clear
adjustment surface with menu structure,
window technology and graphic support.
Configuration
VEGALOG 571 processing system consists
of a CPU, one or several peripheral cards, as
well as a power supply unit which can be
inserted in the 19“-carrier BGT LOG 571.
CPU and peripheral cards are module cards
in European size (DIN 41␣ 494) with 5␣ TE-
width (25,4␣ mm). The supply voltage of the
cards with 24␣ V␣ DC is provided, for example,
via a power supply unit VEGASTAB 593. The
carrier, with a width of 84␣ TE, and a height of
3␣ HE, corresponds to the 19“-standard for-
mat, is provided with an integral LOGBUS-
board for communication among the cards.
A VEGALOG can be equipped with a maxi-
mum of two carriers with a total of one CPU,
31 peripheral cards and a power supply unit.
Up to 255 measurement loops can be cre-
ated.

VEGALOG 571 5
FB
1
255
EB
1
255
AB
1
255
PB
1
255
1.2 Software
Software components
Each VEGALOG software consists of max. 255 input, output, DCS and functional components.
All components are automatically used by the system when configurating a measurement
loop.
Product description
DCS-components
- DCS-telegram to VEGA-
COM␣ 557
Functional components
Parameter for
- meas. loop 1
- meas. loop 2
…
- meas. loop 255
Input components
Analogue inputs
- current inputs
0␣ …␣ 20␣ mA
active/passive
Switching inputs
- signals of level switches
- correction signals
Digital input
- VBUS-input
Output components
Analogue outputs
- current outputs
0␣ …␣ 20␣ mA
Switching outputs
- relay outputs
- transistor outputs
Digital outputs
- DISBUS-output

6VEGALOG 571
1) Input active = Sensor is powered by the EA-card
Input passive = Sensor delivers current
on
VEGALOG
571 EA
!
EA-card
1.3 Module card types
The modular system of VEGALOG 571 con-
sists of different, special module card types:
- CPU-card
- input cards
- output cards
- communication cards
for connection to standard bus systems
- power supply card
for supply of the cards
CPU-card
Product description
on
PC
VEGALOG
571 CPU
!
CPU-card
CPU-card
PC with adjustment program
VEGA Visual Operating
This computer card is the centre of
VEGALOG and has the following functions:
- communication between the individual
cards
- calculating tasks such as scaling, linearisa-
tion, differential generation etc.
- coupling to the PC via RS 232-interface
Furthermore, the CPU is used for level detec-
tion or monitoring of switch on and off times.
Depending on the number of measurement
loops, CPU-cards in different performances
of up to 15, 30, 60 or 255 measurement loops
are available.
The CPU reads cyclically measured values
from the peripheral cards (with, for example,
30 measurement loops in 300␣ ms-cycle).
These are compared with the programmed
data, standardised and processed. The
programmed data (configuration data, ad-
justment parameters etc.) are available in the
EEPROM, where they remain even in case of
voltage loss. In the memory of the CPU a
process picture is created which is provided
to the peripheral cards via the LOGBUS.
For back-up, the programmed data can be
transferred via the RS 232-interface to the PC
and saved there on the hard drive or on a
diskette.
Input cards
EA-card
Up to 10 sensors can be connected to the
EA-card (input analogue) via active1) current
inputs 0/4␣ …␣ 20␣ mA:
- capacitive electrodes
- hydrostatic pressure transmitters
- vibrating level switches
- conductive electrodes
- process pressure and differential pressure
transmitters
- switching contact (level switch)

VEGALOG 571 7
Product description
The inputs can also be switched passively1)
and are used for connection of:
- switching contacts with additional current
source
- external current sources 0 … 20 mA
A mixed switching of active/passive1) inputs
is also permitted within an EA-card.
EV-card
EV-card
AA-card
on
VEGALOG
571 EV
!
on
VEGALOG
571 AA
!
88888
hl
The EV-card (EV = input VBUS) powers up to
15 VBUS-sensors and processes their meas-
ured data:
- hydrostatic pressure transmitters
- ultrasonic sensors
- radar sensors
The digital communication between sensors
and the EV-card enables the connection of
different VBUS-sensors via common two-wire
line. This means that a transmission is avail-
able which is not only optimally adapted to
the conditions of the level measurement, but
also has increased immunity to interference.
In addition to the real transmission of meas-
ured values, it also enables the parameter
adjustment of the sensors via the signal con-
ditioning instrument from the control room
(local parameter adjustments are carried out
via the PC with VVO).
Separators
VEGATRENN 547V Ex
VEGATRENN 548V Ex
The separators are used for galvanic isola-
tion of the intrinsically safe from the not-intrin-
sically safe VBUS-measuring lines, and for
intrinsically safe supply and signal transmis-
sion of Ex-approved VBUS-sensors.
Separators
on
VEGALOG
571 EV
!
Output cards
AA-card

8VEGALOG 571
The AA-card (AA = output analogue) pro-
vides the processing results via up to 10
analogue currents in the range of 0␣ …␣ 20␣ mA.
The scaling, as well as the definition as rising
or falling characteristics is made via the PC
with VVO.
Indicating instruments, recorders, controllers
or PLC-systems are connected to these
outputs.
AD-card
AD-card
Product description
AR-card
AT-card
on
VEGALOG
571 AD
!
on
VEGALOG
571 AR
1
2
3
4
5
6
7
8
9
10
!
on
VEGALOG
571 AT
1
2
3
4
5
6
7
8
9
10
!
88888
hl
The AD-card (AD = output DISBUS) brings
max. 15 measured values to one DISBUS-
line. Up to 30 VEGADIS 174 indicating instru-
ments can be connected to this line.
AR-card
The AR-card (AR = output relay) provides 10
relay outputs with floating spdt. The following
instruments can be connected:
- acoustic or optic signallers
- magnet valves
- contactors
- etc.
The AR-card is suitable for the output of level,
individual or collected fault signals. The
switching condition of each relay is indicated
via a two-coloured LED in the front facia. This
LED lights depending on the parameter ad-
justment of the relay as level contact or as fail
safe relay. Each fail safe relay can be indi-
vidually co-ordinated to one or several meas-
urement loops. The definition of the relay
function, the switch points, as well as the
LED-colour is made via the PC with VVO.
AT-card
The AT-card (AT = output transistor) provides
10 floating outputs via NPN-transistors. Bi-
nary input cards of PLC-systems are con-
nected.
The application possibilities and the signalling
of the switching condition correspond to the
AR-card.

VEGALOG 571 9
Communication card
Product description
VEGACOM 557
The communication card VEGACOM 557 is
an interface converter (Gateway) for conver-
sion of VEGA-specific data formats into
standard protocols for connection of the
VEGALOG-system to a PLC or DCS. The
communication card is available for the fol-
lowing protocols:
- Siemens S5 (3964 R-procedure)
- Modbus (RTU and ASCII)
- Interbus S
- Profibus FMS
- Profibus DP
- VEGA-ASCII
The communication card can be used exclu-
sively to provide the data of VEGALOG to the
visualisation software Visual VEGA (VV). For
this purpose, the communication card is also
available without interface converter function.
Adapter print
VEGACOM 557 AP
PC
VEGACOM
557AP
PC
With the adapter card VEGACOM 557␣ AP, the
data of the standard protocols (Profibus,
Interbus etc.), which are normally only avail-
able at the back of the carrier, can also be
provided on the front facia.
Power supply card
VEGASTAB 593
VEGASTAB 593
on
on
PC
VEGACOM 557
!
BA
The power supply card powers all
VEGALOG cards. The versions VEGASTAB
593-60 (24␣ V,␣ 45␣ W) and VEGASTAB 593
(24␣ V,␣ 120␣ W) are available.

10 VEGALOG 571
Product description
1.4 Technical data
Common data (except VEGASTAB 593)
Power supply
Operating voltage of the cards Unom = 24 V DC (18 … 36␣ V)
Power consumption
- CPU-card max. 6 W
- EA-card max. 11 W
- EV-card max. 10 W
- AA-card max. 9 W
- AD-card max. 10 W
- AR-card max. 6 W
- AT-card max. 6 W
- VEGACOM 557 max. 6 W
Fuse 1 A slow-blow
Electrical connection
Module card multiple plug acc. to DIN 41 612, series F,
48-pole (d, b, z) with coding hole
Module in carrier BGT LOG 571 suitable multipoint connector acc. to DIN 41 612
with connection via standard technologies
Electrical protective measures
Protection
not mounted IP 00
in carrier BGT LOG 571
- front side completely equipped IP 40
- upper and lower side IP 20
- wiring side IP 00
Protection class I (in carrier BGT LOG 571)
Overvoltage category II
CE-conformity
The module cards of VEGALOG 571 meet the protective regulations of EMVG
(89/336/EWG) and NSR (73/23/EWG). The conformity has been judged acc. to the following
standards:
EMVG Emission EN 50 081 - 2
Susceptibility EN 50 082 - 1
NSR EN 61 010
Ambient conditions
Permissible ambient temperature -20°C … +60°C
Storage and transport temperature -20°C … +80°C
Mechanical data
Series module cards for carrier
BGT LOG 571
Dimensions, not mounted W = 25,4 mm (5 TE), H = 128,4 mm (3 HE),
D = 166 mm
Weight per card approx. 400 g

VEGALOG 571 11
CPU-card
Interfaces
To LOGBUS via LOGBUS-socket on the module card
RS 232 via PC via 9-pole D-SUB-socket (pins)
in the front plate of the module card
Electrical separating measures
Galvanic isolation
acc. to VDE 0106, part 1 between power supply, LOGBUS-connection
and RS 232-interface
- reference voltage 250 V
- isolation resistance 2,3 kV
Indicating elements
LED in front plate green (on): operating voltage on
red: fault signal
EA-card
Meas. data inputs
Number 10 inputs
Kind analogue two-wire input,
active or passive also mixed
Range 0 … 20 mA
Sensors capacitive electrodes
hydrostatic pressure transmitters
vibrating level switches
conductive electrodes
process and differential pressure transmitters
Further connection possibilities external current sources 0 … 20 mA, switching
contacts
Sensor supply voltage 24 V DC
Current limitation per sensor circuit 26,5 mA, permanently short
circuit-proof
Max. input voltage 24 V DC
Switching threshold adjustable via adjustment software VVO
in the range of 4 … 20 mA
Min. hysteresis 80 µA (fixed)
Linearity error 0,1 % of range (for input active and passive)
Average gradient failure 0,5 % of range (only for input passive)
Temperature failure 0,025 %/10 k of range
Connection line 2-wire (standard line)
Resistance per conductor max. 35 Ω
Interfaces
To LOGBUS via LOGBUS-plug on the module card
Product description

12 VEGALOG 571
Product description
Electrical separating measures
Galvanic isolation
acc. to VDE 0106, part 1 between power supply, LOGBUS-connection
and meas. data inputs
- reference voltage 250 V
Common reference potential between the individual meas. data inputs (GND)
Indicating elements
LED in front plate green (on): mains voltage on
red: fault signal
EV-card
Meas. data inputs
Number 15 inputs
Data transmission digital (VBUS)
Sensors hydrostatic pressure transmitters
ultrasonic sensors
radar sensors
Sensor supply voltage 3 x 24 V DC, 1 A, short circuit proof
(for 5 sensors each)
Connection line 2-wire (screening recommended)
Line length max. 1000 m 1)
Resistance per conductor max. 15 Ω
1)
Interfaces
To LOGBUS via LOGBUS-plug on the module card
Electrical separating measures
Galvanic isolation
acc. to VDE 0106, part 1 between power supply, LOGBUS-connection
and meas. data inputs
- reference voltage 250 V
Common potential between VBUS-meas. data inputs
Indicating elements
LED in front facia green (on): operating voltage on
red: fault signal
1) The values are valid for a connected sensor. Note reduction acc. to “Connection instructions for VBUS-
sensors“

VEGALOG 571 13
AA-card
Current outputs
Number 10 outputs
Function analogue output of processing results
Range 0/4 … 20 mA
(current limitation or fault signal 22 mA)
Load max. 750 Ω
Resolution 0,05 % of range (10 µA)
Linearity error 0,025 % of range
Temperature error 0,025 %/10 k of range
Load dependent error with load of 750 Ω: 0,5 % (100 µA)
Interfaces
To LOGBUS via LOGBUS-plug on the module cards
Electrical separating measures
Galvanic isolation
acc. to VDE 0106, part 1 between power supply, LOGBUS-connection
and current outputs
- reference voltage 250 V
Common potential between current outputs (GND)
Indicating elements
LED in front facia green (on): mains voltage on
red: fault signal
AD-card
DISBUS-output
Number 1 output
Function digital transmission of processing results
and system information to VEGADIS 174
Number of instruments to be connected max. 2 x 15 VEGADIS 174
Connection line 2-wire (screening recommended)
Max. line length 1000 m
Max. line resistance 15 Ωper wire
Interfaces
To LOGBUS via LOGBUS-plug on module card
Electrical separating measures
Galvanic isolation
acc. to VDE 0106, part 1 between power supply, LOGBUS-connection
and DISBUS-output
- reference voltage 250 V
Indicating elements
LED in front facia green (on): operating voltage on
red: fault signal
Product description

14 VEGALOG 571
Product description
AR-card
Relay outputs
Number 10 outputs
Hysteresis adjustable
Contact 1 floating spdt each
AgNi and hard gold plated
Turn-on voltage min. 10 mV DC
max. 250 V AC, 60 V DC
Switching current min. 10 µA DC
max. 2 A AC, 1 A DC
Breaking capacity max. 125 VA, 54 W
Interfaces
To LOGBUS via LOGBUS-plug on the module card
Electrical separating measures
Reliable separation acc. to VDE 0106, from relays to the power supply and
part 1 LOGBUS-connection
- reference voltage 250 V
- isolation resistance 2,3 kV
Galvanic isolation between among relays
- reference voltage 250 V
- isolation resistance 1,5 kV
Indicating elements
LED in front facia green (on): operating voltage on
yellow/red: switching condition as level/
fail safe relay for each relay
red: fault signal
AT-card
Transistor outputs
Number 10 outputs
Turn-on voltage max. 36 V DC
Switching current ICmax. 60 mA, short circuit proof
Voltage loss UCE ≤1,5 V at IB= 60 mA
Interfaces
To LOGBUS via LOGBUS-plug on the module card

VEGALOG 571 15
Electrical separating measures
Galvanic isolation
acc. to VDE 0106, part 1 between power supply, LOGBUS-connection
and transistor outputs
- reference voltage 250 V
Potential separation between among transistor outputs
- reference voltage 50 V
- isolation resistance 0,5 kV
Indicating elements
LED in front facia green (on): operating voltage on
yellow/red: switching condition as level/
fail safe transistor for each output
red: fault signal
VEGACOM 557
Meas. data input DISBUS
(only used in conjunction with VEGAMET signal conditioning instrument)
Data transmission DISBUS (digital data transmission)
Connection line 2-wire, screening recommended
Line length max. 1000 m
Meas. data input LOGBUS
Data transmission LOGBUS (digital data transmission)
Connection line connection via BUS-plug
PC-interface
Interface standard RS 232 C
Line length max. 15 m
Transmission rate 300, 600, 1200, 2400, 4800, 9600 and
19200 baud
Transmission format 8 data bits, 1 stop bit, even parity or
no parity
Plug in the front facia D-SUB-plug connector, 9-pole, pins
Electrical separating measures
Reliable separation acc. to VDE 0106, between power supply, LOGBUS, DISBUS,
part 1 PC-connection and appropriate interface
- reference voltage 250 V
- test voltage 3 kV
Indicating elements
LED in front facia green BA: communication signal (bus activity)
red (flashing): DISBUS/LOGBUS-failure
red (permanently): failure
green on: operating voltage on
Interface data
see operating instruction VEGACOM 557
Product description

16 VEGALOG 571
Power supply card VEGASTAB 593, 594, 593-60
Common data
Indicating elements
LED in front facia green on: operating voltage on
Electrical connection
Multiple plug VEGASTAB acc. to DIN 41 612, d, z, series H, 15-pole
Module carrier multipoint connector with connection plug 6,3 mm
Electrical protective measures
Protection
- unassembled
VEGASTAB 593, 594 IP 20
VEGASTAB 593-60 IP 00
- mounted in carrier IP 40 (only front)
Protection class I
CE-conformity
The 19“-power supply units VEGASTAB meet the protective regulations of EMVG
(89/336/EWG) and NSR (73/23/EWG). The conformity has been judged acc. to the following
standards:
VEGASTAB 593, 594 VEGASTAB 593-60
EMVG Emission EN 50 081 - 1 EN 50 081 - 1
Susceptibility EN 50 082 - 2 EN 50 082 - 2
NSR EN 60 950 EN 61 010
Mechanical data
Dimensions W x H x D = 50,8 (10 TE) x 110 x 171,9 mm
Weight
- VEGASTAB 593, 594 approx. 550 g
- VEGASTAB 593-60 approx. 1,3 kg
VEGASTAB 593, 594
Power supply
Input voltage Unom = 230 V AC (196␣ …␣ 264 V), 50/60 Hz
= 115 V AC (90 … 132 V), 50/60 Hz
(switch for conversion of the input voltage
at the housing bottom, factory setting
230 V)
Input current effective max. 0,8 A at 230 V
max. 1,6 A at 115 V
Interference suppression acc. to VDE 0871, class B, 16 kHz … 30 MHz
Product description

VEGALOG 571 17
Product description
Output
Output voltage
- VEGASTAB 593 Unom = 24 V DC stabilised
- VEGASTAB 594 Unom = 33 V DC stabilised
Output power Pnom = 120 W
Output current Inom = 5 A
Other conformities
EMC-conformity VDE 0160/2, IEC 801, NAMUR
VDE 0871/B, EN 55 022/B
Ambient conditions
Permissible ambient temperature -20°C … +70°C (+55°C … +70°C limited)
Storage and transport temperature -40°C … +70°C
VEGASTAB 593-60
Power supply
Input voltage Unom = 230 V AC (196␣ …␣ 264 V), 50/60 Hz
= 110 V AC (94 … 127 V), 50/60 Hz
= 120 V AC (102 … 138 V), 50/60 Hz
Input current effective
- 230 V max. 0,5 A
- 110 V, 120 V max. 1,0 A
Fuse (5 x 20 mm) in the L-line
- 230 V 1 A moderately slow-blow
- 110 V, 120 V 1,6 A moderately slow-blow
Output
Output voltage Unom = 25 V DC
Output power Pnom = 45 W (40 W at ambient temperature
-40°C … +60°C)
Output current Inom = 2 A
Resistance short circuit and open-circuit resistant
Open-circuit voltage 33 V
Ambient conditions
Permissible ambient temperature -20°C … +60°C (+35°C … +60°C screwed)
Storage and transport temperature -40°C … +70°C

18 VEGALOG 571
1.5 Dimensions
The dimensions are shown on the example of the CPU-card, they are also valid for the other
module cards of VEGALOG.
CPU-card
162
100
5,5
128,4
25,4
5 TE
9
on
571 CPU
PC
VEGALOG
!
Multipoint connector
100 x 160 x 1,5
European size Multiple plug
LOGBUS-plug
Power supply card VEGASTAB
Product description
,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
,
,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
,
,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
,
,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
,
,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
162
96
5,5
128,4
10 TE
on
50
93
4
Multipoint connector
100 x 160 x 1,5
European size
Multiple plug

VEGALOG 571 19
1.6 Applications
A number of applications can be created in
VEGALOG with the VEGA Visual Operating
(VVO) adjustment software. On the following
pages you see applications with the appro-
priate sensors, mode and option.
VVO must be stated to create a new applica-
tion (measurement loop). Click in the main
window of VVO on Configuration, point to
Measurement loop and click on New. Then
confirm the adjustment “a new application“
with OK.
In the next window (“Create new measure-
ment loop -Application-“), you first choose the
application (e.g. level measurement), then the
sensor type (e.g. hydrostatic). Then click on
Continue>> and choose the mode (e.g.
pressurised vessel) and the option (e.g. real
value correction).
Product description
Application Sensor type
Mode Option

20 VEGALOG 571
Product description
Process pressure measurement as
differential pressure measurement
Pos. A
Process pressure measurement as
standard pressure measurement
Pos. A
Pos. A
Single measurements
Application: Level measurement
Sensor: Capacitive electrodes
Hydrostatic pressure transmitters
Ultrasonic sensors
Radar sensors
Process pressure transmitters
Differential pressure transmitters
Mode: Standard
Option: Correction in the point
Real value correction
Zero point correction
Density correction
Parameter: Level
Application: Gauge measurement
Sensor: Hydrostatic pressure transmitters
Ultrasonic sensors
Radar sensors
Mode: Standard
Option: none
Parameter: Gauge
Application: Process pressure measurement
Sensor: Process pressure transmitters
Differential pressure transmitters
Mode: Standard
Option: Zero point correction
Parameter: Process pressure
Application: Process pressure measurement
Sensor: Differential pressure transmitters
Mode: Difference
Option: none
Parameter: Pressure difference
Pos. A Pos. A Pos. A
Pos. A Pos. A
Pos. A
Level measurement
Pos. A Pos. A Pos. A
Gauge measurement
Table of contents
Other Vega Controllers manuals

Vega
Vega VEGAMET 341 User manual

Vega
Vega VEGAMET 861 User manual

Vega
Vega VEGATOR 141 User manual

Vega
Vega VEGAMET 624 User manual

Vega
Vega VEGAMET 141 Installation instructions

Vega
Vega VEGATOR 121 User manual

Vega
Vega VEGAMET 862 User manual

Vega
Vega VEGATOR 131 User manual

Vega
Vega plicscom User manual

Vega
Vega VEGAMET 141 User manual

Vega
Vega VEGATOR 142 User manual

Vega
Vega VEGAMET 862 User manual

Vega
Vega C-6124 User manual

Vega
Vega VEGAMET 841 User manual

Vega
Vega VEGATOR 122 User manual

Vega
Vega VEGAMET 342 User manual

Vega
Vega VEGATOR 132 User manual

Vega
Vega VEGAMET 841 User manual

Vega
Vega VEGATOR 112 User manual

Vega
Vega VEGATOR 111 User manual