VENTILATOR TECHNICAL DATA
Speed I II III
Unit voltage [V /50-60 Hz] 1~100-230
Air capacity [m3/h] (CFM) 14 (8) 28 (16) 54 (32)
Power [W] 3,80 3,96 5,61
Current [A] 0,024 0,026 0,039
RPM 610 800 1450
Noise level, 1 m [dB(A)] (Sones) 22 (0,4) 29 (0,7) 32 (1,0)
Noise level, 3 m [dB(A)] (Sones) 13 (0,2) 20 (0,4) 23 (0,5)
Outdoor noise attenuation [dB(A)] (Sones) 18 (0,4)
Heat recovery eciency up to 90%
UNIT DESIGN AND OPERATING LOGIC
The ventilator consists of a telescopic air duct with adjustable length (inner part and outer part), a ventilation unit and an outer ventilation
hood. Two lters and a ceramic regenerator are located inside the inner duct of the telescope.
The air lters are designed to purify supply air and prevent foreign object ingress into the regenerator and the fan.
The ceramic regenerator utilises extract air heat energy to warm up supply air ow. The cord laid inside the regenerator is designed to pull
the regenerator from the ventilator. The regenerator is heat insulated with a specially designed insulating material.
The ventilation unit must be installed on inner side of the wall. The ventilation unit is equipped with automatic shutters that shut the air
duct o during the ventilator standby and prevent air back draft.
The ventilation hood must be installed on outer side of the wall. It is used for directed air discharge and prevention of ingress of water and
other objects to the ventilator.
VENTILATOR DESIGN
Ventilation unit
Generates air ow by means of the fan.
The ventilation unit is covered with a
ventilation grille on inner side of the wall
to prevent ingress of foreign objects into
the fan.
The ventilation unit is equipped with
automatic shutters to prevent back draft
of air. The air shutters open during
operation of the ventilator and close
when the unit is turned o.
Mounting plate
A mounting plate for
installation of the ventila-
tion unit on the wall and
connecting it to power
mains.
Air ow rectier
Eliminates air turbulence
inside the ventilator.
Outer air duct
Outer part of the
telescopic air duct.
Inner air duct
Inner part of the
telescopic air duct.
Outer ventilation hood
Prevents direct ingress of water and
foreign objects into the ventilator.
Filter
Cleans supply air ow
and prevents ingress of
dust and foreign objects
into the ventilator. Filters
also prevent regenerator
soiling.
Ceramic regenerator
The ceramic regenerator
utilises extract air heat
energy to warm up supply
air ow.