Veria Quickmat 2C User manual

Veria Quickmat 2C 100/150W/m²
Installation guide
Installasjonsveiledning
Installationsvejledning
Installationshandledning
Asennusopas
Руководство по установке
Montavimo instrukcija
Manuel d’installation
Руководство по установке
Instalační příručka
Návod na inštaláciu

4
Fig. 2
Fig. 1
Fig. 4b Fig. 5
Fig. 8a Fig. 8b
23
6 cм
50 cм

5
Fig. 3 Fig. 4a
Fig. 6
Fig. 10
Fig. 9
Fig. 7

6
Veria Quickmat is a 2-conductor heating mat which, due to the low tting height
(approx. 3,8 mm), is particularly suitable for renovating existing oors.
Your underlay/under-oor will decide how big an output your Veria Quickmat should
have. Follow the instructions in the table below.
Note that the heating mat must be connected to the power supply by an authorised
electrician.
Product specifications – Veria Quickmat 100/150 W/m²
Voltage: 230 V
W x L: See Label
Max. temperature: 120 ˚C
Certified by: Semko
Areas of application Max. output per m² Max.surface
temperature Thermostat
Wooden oor underlay with carpet, vinyl
or parquet on top 100W/m227˚C Thermostat with oor sensor and max.
temp. 35 degrees
Wooden oor underlay with tiles on top 100W/m227˚C Thermostat with oor sensor and max.
temp. 35 degrees
Concrete oors with carpet, vinyl or
parquet on top 100W/m227˚C Thermostat with oor sensor and max.
temp. 35 degrees
Concrete oors with tiles on top 150W/m2None Thermostat with oor sensor and max.
temp. 45 degrees
Note that the yellow cable must not be cut under any circumstances.
The heating mat/cable must never be double-laid, overlap or cross over itself.
The product must be used to heat the oor directly.
The heating mat must be embedded.
Connection:
Phase:
Neutral:
Earth:

7
Congratulations on your new Veria product!
By following the installation guidelines below you are guaranteed a high-performing result and many years of troublefree use.
1Let’s get started
A. Necessary tools: Hammer, chisel, pencil, tape measure, craft knife, multimeter, insulation tester and this guidance leaet and plan.
B. Plan: Draw your room on the graph paper (g. 2). Remember to draw in any xed furniture/cupboards etc. and the location of your
thermostat/power supply. The heating mat should not be installed beneath items xed to the oor, such as cupboards, bathtubs, toilets
etc.
Your Veria Quickmat should have a smaller m² measurement than the available oor area. Any “excess” oor area (without oor
heating) is spread along the walls. Draw in your Veria Quickmat (w: 48 cm) with a gap of 2 cm between the lines on the plan.
Note that the adhesive backing mat under the heating cable can be cut by changing the direction on the layout plan (g. 3).
C. Transfer your plan with its markings onto the oor, so that you know exactly where you will start and nish.
2Test your Veria Quickmat
Before you lay the heating mat you must check that the heating conductors works properly.
The resistance value is measured using a multimeter between the blue and black sections (g. 4a). Check that the value measured
matches the value of the label attached to the cold tail connection. The value displayed must lie within -5% - +10% of the given ohm value.
Make a note of the value measured on the proof of warranty.
Then measure the insulation value with an insulation tester by measuring between the screen (outer connector wiring) and both the black
and blue sections (g. 4b). The measured value must be over 10 MΩ. If this is the case tick the eld on the proof of warranty.
3Preparation and cleaning
Power supply and oor sensor
Start by cutting/drilling a groove in the wall and oor from the connection point. A separate tube for the thermostat’s oor sensor and the
heating mat’s power cables is tted into this groove (g. 5).
Make sure that the groove for the oor sensor stretches at least 50 cm out into the room and that the sensor is placed between two heating
cables. The curve of the tube must have a radius of no less than 6 cm.
Before you t the cable mat you must prepare the oor surface (g. 6)
A. Make sure that loose items and sharp edges are removed and that the oor is vacuum-cleaned or washed.
B. For improved adhesion of the heating mat it is strongly recommended that the oor be primed before installation.
This must be done after the cleaning has been completed.
4Fitting
Fitting the mat
Start by removing the protective plastic foil from the mat. Start rolling it out (with the self-adhesive side towards the oor), referring to
your layout plan.
Place the start of the mat close to the electricity installation/desired thermostat location (g. 7). Note that the connections between
the yellow heating cable and the power cable must be embedded.
Spread out the heating mat in the room, referring to your layout plan. When you meet an obstacle (walls, cupboards, toilets or similar),
cut the adhesive backing mat (not the heating cable!) and continue in a new direction (g. 8a-8b).
If the cable, due to installation purpose, has been detached from the adhesive backing mat it can be glued to the underlay using a glue
gun.
5Midway test
After laying out the mat please measure the resistance value in the mat again (g. 4a-4b). Use the same procedure as in section 2
– then make a note of the values on the proof of warranty.
Installation guide EN

8
6Filling/Final measurement
When the mat has been laid as desired press the mat down against the floor to ensure optimal adhesion. Feed the power cable to the
thermostat connection point. Then cover the heating mat with a layer of flexible self levelling compound or flexible tile adhesive (fig. 9).
When subsequently laying a tiled floor on top the heating cable must simply be covered, whilst wooden floors, laminates, rugs, vinyl etc.
require a filling layer of at least 5 mm on top of the heating cable (fig. 10).
It is recommended that the self levelling compound or tile adhesive be left to harden in accordance with the manufacturer’s instructions
before the top floor is laid (tiles, wooden flooring, laminate etc.).
After fitting, measure the resistance value in the mat again (fig. 4a-4b). Use the same procedure as in section 2 – then make a note of the
values on the proof of warranty.
7Finishing
After the work has been completed the oor must harden completely before the oor heating and thermostat are connected. This process
usually takes 8-10 days, but you should refer to the ller manufacturer’s guidelines. To connect the thermostat, please refer to the
thermostat installation guidelines.
Please note that Veria Quickmat must be supplied through a residual current device (RCD) having a rated residual operating
current not exceeding 30 mA.
Veria Quickmat can be used with the following thermostats:
Veria Control B35/45 Veria Control T45 Veria Control W35/45
Veria wish you all the best with your new heated oors!
12-year warranty for Veria Quickmat and Veria Flexicable
Veria’s products have been developed for many years of trouble-free use. Assuming that they are installed
correctly – according to the installation guidelines – we therefore provide a 12-year warranty on Veria
Quickmat and Veria Flexicable. A 2-year warranty is provided on other Veria products.
The warranty covers products that appear to be defective due to manufacturing, construction or material
faults.
However, the warranty is void if:
• The product has not been installed according to the installation guidelines
• It has not been connected by an authorised electrician
• The fault is caused by inappropriate/poor oor construction
The warranty is also conditional upon the accompanying proof of warranty having been lled in correctly. The proof of warranty must be
retained by the owner and must be produced in the event of a claim.
In the unlikely event that you have to make use of the warranty, we will repair the product or supply a new replacement product free of
charge. The warranty does not cover any indirect or additional costs such as costs relating to the localisation of the fault, removing the
product, repairing the oor etc.
In the event of a warranty claim the product will be sent to Veria – as agreed in advance - with a tracking label attached, stating the nature of
the fault. If our investigation shows that the product is not faulty it will be returned. If we nd any faults Veria will return the repaired product
or supply a new Veria product and will take away the parts that have been removed or the faulty Veria product.
No additional claims may be made against Veria under the warranty.
years
12
Warranty
by Veria

9
EN
Proof of Warranty
A 12-year warranty is hereby provided for:
Name:
Address:
Telephone:
Postcode & Town:
Please note!
The Veria warranty is only valid if the following details have been lled in correctly. See the conditions below.
The proof of warranty must be retained by the purchaser.
Heating mat laid by: Date:
Connected by: Date:
Veria Quickmat Result
Insulation resistance
Before embedding Above 10 MΩ
After oor covering Above 10 MΩ
Heating Cable Resistance
Before laying = Ω
Before embedding in mortar = Ω
After embedding in mortar = Ω
Mat length:
Item number: (see label):
Installers stamp:
years
12
Warranty
by Veria
VERIA
Ulvehavevej 44
7100 Vejle,
Denmark
E-mail: [email protected]
Table of contents