Veridian 09-348 User manual

Touch-Free
Infrared Thermometer
Model 09-348
3-YEAR
INST UCTION MANUAL • ENGLISH & ESPAÑOL
READ HIS INS RUC ION MANUAL
CAREFULLY BEFORE USE

2• ENGLISH
STOP!
PLEASE ENSU E YOU HAVE ALL OF THE
FOLLOWING COMPONENTS BEFO E USING
YOU INF A ED DIGITAL THE MOMETE
IF YOU A E MISSING ANY PA TS, INCLUDING
INSE TS O INST UCTION MANUALS, DO NOT
ETU N TO PLACE OF PU CHASE. CONTACT
CUSTOME CA E AT 8663261313.
Thermometer 2 AAA Batteries
Instruction Manual
Quick Start uide

ENGLISH • 3
INDEX
Introduction................................................................................4
Body Temperature and Fever .................................................5
Tips for Measuring Body Temperature .................................5
Display Symbols.........................................................................6
Product Features........................................................................7
Measurement Modes-Denition & Use ...............................8
Measuring Body Temperature................................................9
Measuring Object/Liquid Temperature .............................10
Setting Night/Sleeping Mode..............................................11
Switching Between Fahrenheit and Celsius .....................11
Recalling and Clearing Measurements..............................12
Replacing the Battery ............................................................13
Care and Safety Information ................................................14
Cleaning and Storage ............................................................15
Troubleshooting......................................................................16
Product Specications ...........................................................17
Warranty....................................................................................18
Instrucionnes en Espanol................................................21-38
Toll-Free Customer Care Help Line: 1-866-326-1313
Monday – Friday 8:30 a.m. – 4:30 p.m. CST
Distributed by
Veridian Healthcare
1175 Lakeside Drive
urnee, IL 60031
www.veridianhealthcare.com
Made in China
#93-1149 05/15
©2015 Veridian Healthcare, LLC

INTROD CTION
4• ENGLISH
Thank you for purchasing this Veridian Touch-Free Infrared
Thermometer. Please read this instruction manual completely before
using your unit to ensure safe use, accurate results and long life of the
thermometer.
This product is intended for household use; this product is not
intended to diagnose or treat any health problem or disease and
should not be used as a substitute for the consultation and advice of a
physician or other medical professional. Thermometers should only be
used under the supervision of an adult.
The infrared technology used in this thermometer takes the
temperature of people and objects without any physical contact
between the thermometer and the person or object. The thermometer
measures body temperature from approximately 0.5” – 1” from the
forehead, making it less invasive and threatening than other
thermometers, as well as more sanitary. It can even be used when the
patient is sleeping. This thermometer also measures the temperature
of objects and liquids, making it useful for determining if a baby’s milk
or bathwater is ready.
All people and objects emit infrared energy. Veridian’s Touch-Free
Infrared Thermometer measures that energy, taking 512 readings in
one second and converting those data to a single peak temperature,
which appears on the display. With proper care, your new
thermometer will provide your entire family with many years of safe,
accurate and comfortable temperature readings.

ENGLISH • 5
BODY TEMPERAT RE AND FEVER
Body temperature can vary from 97°F(36.1°C) and 99°F(37.2°C) and
still be considered normal. The medically accepted ‘normal’ body
temperature is 98.6°F(37°C). Body temperature is commonly lower
upon waking than at any point during the rest of an individual’s active
hours.
A fever is dened as a body temperature that is elevated above the
normal for that person. It is important to determine what is normal for
an individual before determining if a fever is present. Tracking an
individual’s temperature on a consistent basis, at the same body site
and at the same time every day will help determine an individual’s
normal temperature.
TIPS FOR MEAS RING BODY
TEMPERAT RE
• Wait at least one minute between consecutive readings, to ensure
accuracy.
• Attempting to take temperature readings from sites on the body
other than the forehead may produce inaccurate results.
• The patient should remain still while the reading is being taken.
• If “Lo,” “Hi,” “Err,” or another error message appears, see the
Troubleshooting section of this manual for instructions on how to
resolve the problem.
• Infrared forehead temperature readings are equivalent to oral
temperature readings.
• Readings taken while asleep should not be compared directly to
readings taken while awake, as body temperature while asleep is
typically lower.
• Do not take body temperature readings within 30 minutes of being
outdoors, exercising or bathing.
• Level of activity, time of day, and other factors may affect body
temperature. Keep records of your individual body temperature to
use as a reference when judging a fever.

PROD CT FEAT RES
6• ENGLISH
Memory
Button
Speaker
LCD
Display
Infrared Lens
Battery
Cover
SCAN / Power
Button
Mode
Button
LED Fever
Alert Signal

ENGLISH • 7
Measurement in progress
Degrees Fahrenheit
Degrees Celsius
Person measurement mode
Object measurement mode
Night measurement mode
Temperature normal; below
100.4° F (38.0° C); person mode
only
Fever alert; temperature
above 100.4° F (38.0° C); person
mode only
Low battery
Memory recall
DISPLAY SYMBOLS

The Touch-Free Infrared Thermometer offers a selection of settings for
use in the day or night and for person or object measurements.
To toggle between modes:
1. Press the MEASURE button to turn the thermometer on. The device
will default the last mode used.
2. Press and release the MODE button to toggle through the four
measurement options.
MEAS REMENT MODES
DEFINITION & SE
8• ENGLISH
Person Mode Object Mode
Person Mode/
Night Mode
Object Mode/
Night Mode

Fig. 1
MEAS RING BODY TEMPERAT RE
ENGLISH • 9
To measure body temperature using your Touch-
Free Infrared Thermometer, follow the below
steps.
NOTE: See page 8 o this manual or more
in ormation on the Denition and Use o the
Measurement Modes.
1. Press and release the MEASURE button to turn
the thermometer on. The unit will run a self-
test and all symbols on the display will
momentarily appear, Fig. 1.
2. The unit will beep
twice and the display will show two solid
dashes .
3. Aim the infrared lens at the individual’s
forehead, holding the thermometer
approximately 0.5” – 1.0” away, Fig. 2.
4. Press and hold the MEASURE button. The
display will briey show the mode, two dashes
and a left facing arrow, Fig. 3.
The thermometer will emit a single beep and
the temperature reading will be displayed, Fig.
4.
5. If the temperature measurement is below
100.4° F, a happy face will be appear next to
the reading. If the reading is 100.4° F or above,
a sad face will be displayed and the red light
will illuminate just below the display.
6. After 30-seconds of non-use, the thermometer
will automatically beep and shut off.
Fig. 3
Fig. 2
Fig. 4

10 • ENGLISH
MEAS RING OBJECT/LIQ ID
TEMPERAT RE
Fig. 1
The Touch-Free Infrared Thermometer can meas-
ure objects and liquids from 32°F to 212°F (0°C -
100°C). To measure the temperature of an object
or liquid using your Touch-Free Infrared Ther-
mometer, follow these steps:
NOTE: See page 8 o this manual or more
in ormation on the Denition and Use o the
Measurement Modes.
1. Press the MEASURE button to turn the
thermometer on. The unit will run a self-test
and all symbols on the display will
momentarily appear, Fig. 1.
2. The unit will beep twice and the display will
show two solid dashes .
3. Aim the infrared lens at the object being
measured, holding the thermometer
approximately 0.5” – 1.0” away, Fig. 2.
4. Press and hold the MEASURE button. The
display will briey show the mode, two dashes
and a left facing arrow, Fig. 3.
The thermometer will emit a single beep and
the temperature reading will be displayed, Fig.
4.
5. After 30-seconds of non-use, the thermometer
will automatically beep and shut off.
Fig. 2
Fig. 4
Fig. 3

ENGLISH • 11
Night Mode is a convenient way to conduct
measurements without an audible beep
indicating the thermometer has powered on or a
measurement is complete.
To toggle between modes:
1. Press the MEASURE button to turn the
thermometer on. The device will default to the
last mode used.
2. Press and release the MODE button to toggle
through the four measurement options.
SWITCHING BETWEEN ºF / ºC
Your thermometer can display results in either
degrees Fahrenheit (°F) or degrees Celsius (°C).
To switch between Fahrenheit and Celsius, while
the unit is on press and hold both the MEM and
the MODE buttons until the °F icon on the display
switches to the °C icon, or vise versa, at which
time the mode has been changed and you may
release the buttons.
SETTING NIGHT/SLEEPING
MODE NO A DIO BEEPING

12 • ENGLISH
Your Touch-Free Digital Infrared Thermometer
automatically stores the last 30 readings taken.
To view the readings stored in memory, follow
these steps:
1. Press the MEASURE button to turn the
thermometer on.
2. Press the Memory button (marked, “MEM”) to
recall the most recent measurement, Fig. 1.
The unit will beep each time the MEM button
is pushed as the measurements are reviewed.
If the device is in ‘Night’ mode, the unit will not
emit a beep.
3. Press and release the MEM button scroll
through the readings from newest to oldest.
The index number in the upper left of the
display indicates the sequential number of the
stored reading on the screen, Fig. 2.
After 30 measurements have been stored in the
memory, the oldest reading will be automatically
deleted.
To clear all records from the memory, hold the
MEM button down until you hear a beep and two
dashes appear on the display, Fig 3.
RECALLING AND CLEARING
READINGS
Fig. 1
Fig. 2
Fig. 3

REPLACING BATTERY
ENGLISH • 13
When the battery power becomes low, the low battery
symbol will appear on the display. The thermometer can still be used
during this time, but the batteries should be replaced as soon as
possible.
If the batteries run out completely, “Lo” will be displayed along with
the low battery symbol. In this case, the batteries will need to be
replaced before using the thermometer again.
The batteries used in the Touch-Free Infrared Thermometer are two
AAA batteries. Either rechargeable or non-rechargeable batteries can
be used in the thermometer. To replace the batteries, follow these
steps:
1. Slide the battery cover off.
2. Carefully remove the old batteries.
Do not use a metal-pointed tool.
3. Insert the new batteries, ensuring
that the positive and negative
ends are aligned correctly.
4. Replace the battery cover.
5. Dispose of the expired batteries in
accordance with local
environmental policies.

14 • ENGLISH
CARE AND SAFETY INFORMATION
Improper care or use of your thermometer may result in injury,
damage to the unit or inaccurate readings, which can lead to a
misdiagnosed fever. Following these instructions will ensure the
thermometer’s accuracy and long life.
• Never allow the thermometer to be used without adult supervision.
• The infrared technology used in this thermometer is safe and is not
harmful in any way. However, we recommend avoiding looking into
the lens during use.
• Clean the lens before and after each use.
• Do not touch the lens with ngers.
• Dropping the thermometer or causing other heavy impact may
damage it.
• Do not store the thermometer in direct sunlight, dusty or humid
environments, or extreme temperatures.
• Do not disassemble the thermometer or attempt to repair it.
• If a reading cannot be taken, and the troubleshooting steps do not
x the problem, the thermometer must be replaced.

CLEANING AND STORAGE
ENGLISH • 15
The lens should be cleaned before and after each use, to eliminate dirt
and ngerprints and ensure the accuracy of your readings. Proper
storage will prevent degradation and damage to the unit.
CLEANING:
• An alcohol swab, or a soft cotton cloth
moistened with 70% isopropyl alcohol, should
be used to gently cleanse the lens. Do not use
water to wash the thermometer.
• The body of the thermometer can be cleaned
with a soft, dry cloth.
• Never use a paper towel to clean the probe tip,
as it may scratch the lens.
• Do not immerse the thermometer or allow
liquid to enter the casing.
• Do not use cleaning agents other than alcohol
to clean the thermometer; abrasives, thinners
or gasoline will damage the unit.
STO AGE:
• Store the unit in an area away from sunlight, dust and humidity.
• Protect the thermometer from mechanical shock or heavy impact.
• Avoid extended exposure to extreme temperatures. The
thermometer should be stored in an environment between -4°F
and 122°F (-20°C—50°C), and with relative humidity of 95% or
lower.
• Remove the batteries during extended storage.

16 • ENGLISH
TRO BLE SHOOTING
Low battery
Unit turned off or
battery problem
Temperature
measurement is below
typical temperature
range
Temperature
measurement is above
typical temperature
range
Ambient air temperature
is outside of the
acceptable operating
range (60.8° F - 104° F
or 16° C - 40° C).
Replace battery before
using thermometer again
Press Power button to
activate unit. Check
battery type or polarity
(position in the unit).
Replace battery.
Reposition the
thermometer and try
again.
Reposition the
thermometer and try
again.
Wait 45 minutes to
stabilize the unit, then
use the thermometer in
an environment within
the permissible
temperature range.
The following chart indicates error messages that may appear on your
display, why they appear, and how you may solve the problem.
Error Symbol Problem or Cause Solution
(blank display)

SPECIFICATIONS
ENGLISH • 17
Name Touch-Free Digital Infrared Thermometer
Model Number 09-348
Display System Liquid Crystal Display with 0.1° F (0.1° C)
resolution
Measuring Range Human body: 93.2°F – 109.4°F (34° C – 43° C)
Object: 32.0°F – 212.0°F (0° C – 100° C)
Accuracy Human body: 96.8°F – 102.2°F (36°C – 39°C)
±0.2°F; outside of range ±.3°F
Object: ≤20°F: ±1°C; >20°F: ±5%
Memory Automatically stores up to 30 readings.
one Two short beeps sounds when the unit is
turned on. Thermometer beeps once for each
memory recall and when unit automatically
turns off. Device does NOT beep when in
Night Mode.
Operating emperature60.8° F to 104.0° F (16.0° C to 40.0° C) with
relative humidity up to 95% (non
condensing)
Storage emperature -4.0° F to 122° F (-20.0° C to 50.0° C)
with relative humidity up to 95% (non
condensing)
Shut-Off Powered-off automatically after every 30
seconds of non-use
Battery 2 – 1.5v alkaline AAA size
Unit Dimensions 4-3/4” (L) x 2” (W) x 2” (H)
(123mm x 50.5mm x 49mm)
Weight Dimensions 4.27 ounces (80 grams) with battery
Accessories Instruction Manual, Quick Start uide, two
AAA size batteries
Specications a e subject to change without notice.

18 • ENGLISH
THREEYEAR LIMITED WARRANTY
Veridian Healthcare guarantees that its Touch-Free Infrared Digital Thermometer
will be free from manufacturing defects for a period of three years from the date
of purchase. This warranty does not cover batteries or other power sources that
may be provided with or used with the Touch-Free Infrared Digital Thermometer.
This warranty is voided if the Touch-Free Infrared Digital Thermometer is
misused or abused in any manner.
If the Touch-Free Infrared Digital Thermometer fails to operate during the time
the original purchaser owns it, return it postage prepaid to: Veridian Healthcare,
Attn: Repair Department, 1175 Lakeside Drive, Gurnee, IL, 60031. When
returning a product, please also include your name, address, phone number and
brief description of the specic problem with your unit. Take care to carefully
package the product to avoid any damage that may occur while in transit;
shipping insurance with returned receipt is recommended. Veridian Healthcare
will repair or replace the defective unit at our option. Repair or replacement of
the defective unit, at the warrantor’s option, is the sole remedy under this
warranty.
ANY IMPLIED WARRAN IES WHICH HE PURCHASER MAY HAVE ARE LIMI ED
IN DURA ION O HE IME HA HE ORIGINAL CONSUMER PURCHASER
OWNS HE PRODUC . Some states do not allow limitations or how long an
implied warranty lasts, so the above limitation may not apply to you.
This warranty constitutes the warrantor’s only reasonability and obligation to
repair and/or replace materials or components, or refund the purchase price.
Veridian will not be responsible for any indirect, incidental, special consequential
or punitive damages or other loss, including, but not limited to damage to or
loss of other property or liable to the purchaser for any amount in excess of the
cost of repair and/or replacement of the unit, or the purchaser for any amount in
excess of the cost of repair and/or replacement of the unit, or the purchase price
of the unit. Some states do not allow the exclusive or limitation of incidental or
consequential damages, so the above limitation or exclusion may not apply to
you.
This warranty gives you specic legal rights, and you may also have other rights
which vary from state to state.


Table of contents
Languages: