environmental SenSorS inStallation GUiDe
Z203269-0P PAGE 1 ©2010 Veris Industries USA 800.354.8556 or +1.503.598.4564 / suppor[email protected] 06101
Alta Labs, Enercept, Enspector, Hawkeye, Trustat, Veris, and the Veris ‘V’ logo are trademarks or registered trademarks of Veris Industries, L.L.C. in the USA and/or other countries.
LCD Wall Mount with Analog Setpoints
1% NIST, 2% NIST, 2%, 3%, 5%
Installer’s Specifications
Input Power* 15 to 30VDC/24VAC, 100mA max.
Outputs Switch-selectable 4-20mA or 0-10V/0-5VDC
(switch affects both outputs)
RH Sensor Digitally profiled thin-film capacitive (32-bit mathematics)
U.S. Patent 5,844,138
Accuracy at 25°C from 10-80% RH** ±2%, 3%, or 5% models
±1% at 20-50% RH (Multi-point calibration NIST traceable)
Reset Rate*** 24 hours
Stability ±1% @ 20°C (68°F) annually, for two years
Linearity Included in Accuracy spec.
Operating Humidity Range 0-100% RH (non-condensing)
Temperature Coefficient ± 0.1%RH/°C above or below 25°C (typical)
Operating Temperature Range 10°-35°C (50°-95°F)
Temperature Accuracy ± 1.0°C ( ± 1.8°F)
Scaling RH: 0-100% RH; Temp: 10°-35°C (50°-95°F) or
0°-50°C (32°-122°F) menu selectable
Calibration Offset RH: Adjustable ±9.9% in 0.1% increments;
Temp: Adjustable ±5.0°C (±9.9°F) in 0.1° increments
Setpoint Range RH: 10-80% RH in 1% increments;
Temp: Minimum to Full Scale in 1° increments
* One side of transformer secondary is connected to signal common, so an isolation transformer or
dedicated power supply may be required.
** Specified accuracy with 24VDC supplied power with rising humidity
***Reset Rate is time required to recover to 50% RH after exposure to 90% RH for 24 hours
RTD/Thermistors in wall packages are not compensated for internal heating of product.
HT SerieS HT SerieS
Dimensions
NOTICE
• This product is not intended for life or safety applications.
• Do not install this product in hazardous or classified locations.
• Read and understand the instructions before installing
this product.
• Turn off all power supplying equipment before working on it.
• The installer is responsible for conformance to all applicable codes.
ProDuct iDentification
quick install
1. Select a mounting location away from ventilation sources. The sensor should be
mounted on a vertical wall, about 4 ½ feet above the floor.
2. Affix the backplate to the wall.
3. Wire the device. Refer to wiring diagram.
4. Install Cover.
SetpointAccuracy NIST
= Analog
1 = 1%
2 = 2%
3 = 3%
5 = 5%
HT
Temp Cal
Certificate
0 = None
1 = 1 point Cal
Validation
2 = 2 point Cal
Validation
Option
B = 100R Platinum, RTD
C = 1k Platinum, RTD
D = 10k T2, Thermistor
E = 2.2k, Thermistor
F = 3k, Thermistor
G = 10k CPC Thermistor
H = 10k T3, Thermistor
J = 10k Dale, Thermistor
K = 10k w/11k with Shunt,
Thermistor
M = 20k NTC, Thermistor
N = 1800 ohm TAC, Thermistor
Q = 1uA/C, Linitemp
R = 10k US, Thermistor
S = 10k 3A 221
T = 100k, Thermistor
U = 20k “D”, Thermistor
N = NIST
(1 & 2% only)
X = No
(2, 3, 5% only)
S
= CE
1.2"
(29 mm)
3.5"
(89 mm)
4.75"
(121 mm)
-+
Enter
A
VERIS INDUSTRIES ™
inStallation GUiDe
Ht SerieS
Z203269-0P PAGE 2 ©2010 Veris Industries USA 800.354.8556 or +1.503.598.4564 / suppor[email protected] 06101
Alta Labs, Enercept, Enspector, Hawkeye, Trustat, Veris, and the Veris ‘V’ logo are trademarks or registered trademarks of Veris Industries, L.L.C. in the USA and/or other countries.
installation
1. Remove the cover by pressing the tab at the top of the sensor while pulling
outward from the top of the cover.
5. Mount the backplate onto the wall using the screws provided.
6. Wire the backplate.
correct incorrect
4. Position the sensor vertically on the wall, 4 ½ feet above the floor.
Five screwholes available; use a
minimum of two for secure mounting.
2. Remove the backplate by unfastening the sensor from the bottom of the backplate
and pivoting the sensor outward.
3. Punch out openings in the backplate.
POWER SOURCE
15 to 30VDC or 24VAC
DIGITAL CONTROL
RH IN
Temp IN
RH setpoint IN
Temp setpoint IN
Thermistor/RTD IN
Thermistor/RTD IN
-
-
-
+
RH output
GND
Thermistor/RTD
Thermistor/RTD
Temp output
RH Setpoint output
Temp Setpoint output
7. Install and configure the sensor.
WARNING: Output select must be
correct before applying power.
RH
YES
AMP
VOLT
NO YES
RUN
CAL
NO
TEMP
–
Minus PlusEnter
+
RH
SENSOR
TEMP
SENSOR
RH
YES
AMPVOLT
NO YES
RUN
CAL
NO
TEMP
–
Minus PlusEnter
+
RUN/CAL JUMPER:
CAL Mode - allows full access to all
features.
RUN Mode - allows access to relay
setpoints ONLY.
RH YES/NO JUMPER:
YES - allows user to change RH setpoint
NO - user can NOT change RH setpoint
TEMP YES/NO JUMPER:
YES - allows user to change TEMP
setpoint
NO - user can NOT change TEMP setpoint
8. Install the cover and snap into place.
VERIS INDUSTRIES ™
inStallation GUiDe
Ht SerieS
Z203269-0P PAGE 3 ©2010 Veris Industries USA 800.354.8556 or +1.503.598.4564 / suppor[email protected] 06101
Alta Labs, Enercept, Enspector, Hawkeye, Trustat, Veris, and the Veris ‘V’ logo are trademarks or registered trademarks of Veris Industries, L.L.C. in the USA and/or other countries.
ht calibration instructions
1. Temperature calibration allows for calibration offset of ±10º F, user discretion.
RH and TEMP can be field calibrated by moving RUN/CAL jumper to CAL position.
2. Relative humidity allows for calibration offset of ±10% RH, user discretion.
ht oPeration instructions
- +
Enter
Display screen
Scroll down
Select
Scroll up
Normal Operation
Temperature Selection
Use the (+) and (-) buttons to scroll to the Thermostat mode:
Humidity Selection
Use the (+) and (-) buttons to scroll to the Humidistat mode:
press ± to change, press * to select
S E T P O I N T
4 5 % R H
S E T P O I N T
7 0 F
press ± to change, press * to select;
setpoint in ˚C if Celsius units are selected
4 5 . 5 % R H
6 8 . 5 º F
NORMAL MODE
VERIS INDUSTRIES ™
inStallation GUiDe
Ht SerieS
Z203269-0P PAGE 4 ©2010 Veris Industries USA 800.354.8556 or +1.503.598.4564 / suppor[email protected] 06101
Alta Labs, Enercept, Enspector, Hawkeye, Trustat, Veris, and the Veris ‘V’ logo are trademarks or registered trademarks of Veris Industries, L.L.C. in the USA and/or other countries.
menu
O U T P U T
0 - 1 0 V
U N I T S
* º F º C
press ± to change, press * to select
press ± to change, press * to select;
setpoint in ˚C if Celsius units are selected
CONFIG/CAL MODE
(Enter by any keypress when
Run/Cal jumper is in CAL position)
4 5 . 5 % R H
6 8 . 5 º F
NORMAL MODE
press ± to change, press * to select
press ± to change, press * to select
press ± to change, press * to select
press ± to change, press * to select;
setpoint in ˚C if Celsius units are selected
press ± to change, press * to select;
options are 50-95˚F (10-35˚C) or 32-122˚F (0-50˚C)
S E T P O I N T
7 0 F
S E T P O I N T
4 5 % R H
C A L T
+ 0 . 0 F
C A L R H
+ 0 . 0 %
T E M P S E T
+ 5 0 + 9 5
Output scaling
(does not affect LCD display)
Only for switch in
Volts position

Other Veris Industries Accessories manuals

Veris Industries AA01 User manual

Veris Industries

Veris Industries AA01 User manual

Veris Industries AG04 User manual

Veris Industries

Veris Industries AG04 User manual

Veris Industries HED Series User manual

Veris Industries

Veris Industries HED Series User manual

Veris Industries AA01 User manual

Veris Industries

Veris Industries AA01 User manual

Veris Industries CW Series User manual

Veris Industries

Veris Industries CW Series User manual

Veris Industries AG01E User manual

Veris Industries

Veris Industries AG01E User manual

Veris Industries AG06 User manual

Veris Industries

Veris Industries AG06 User manual

Veris Industries CD Series User manual

Veris Industries

Veris Industries CD Series User manual

Popular Accessories manuals by other brands

Balluff BTL304K user guide

Balluff

Balluff BTL304K user guide

Pioneer ND-PS1 installation manual

Pioneer

Pioneer ND-PS1 installation manual

El-Björn EBL Boj 48/20 LW manual

El-Björn

El-Björn EBL Boj 48/20 LW manual

Ecolink Z-Wave Installation instruction

Ecolink

Ecolink Z-Wave Installation instruction

AEMC MiniFlex MF 300-6-2-10 user manual

AEMC

AEMC MiniFlex MF 300-6-2-10 user manual

RBR Coda 3 Series Guide

RBR

RBR Coda 3 Series Guide

elsner elektronik Sewi KNX L Installation and adjustment

elsner elektronik

elsner elektronik Sewi KNX L Installation and adjustment

BEA BEAMBOX user guide

BEA

BEA BEAMBOX user guide

Zagg pro stylus Online manual

Zagg

Zagg pro stylus Online manual

Wenglor ShapeDrive G4 MLAS 1 Series operating instructions

Wenglor

Wenglor ShapeDrive G4 MLAS 1 Series operating instructions

SICK T-EASIC FTS operating instructions

SICK

SICK T-EASIC FTS operating instructions

Kobold SEN-9601 operating instructions

Kobold

Kobold SEN-9601 operating instructions

netvox RA0723 user manual

netvox

netvox RA0723 user manual

Honeywell T87 installation instructions

Honeywell

Honeywell T87 installation instructions

FTS FLEXI-COOL FC55 instruction manual

FTS

FTS FLEXI-COOL FC55 instruction manual

Sirius XM RAdio Home Kit user guide

Sirius XM RAdio

Sirius XM RAdio Home Kit user guide

DigiGrid DESKTOP INTERFACE Quick start guides

DigiGrid

DigiGrid DESKTOP INTERFACE Quick start guides

Grundig 871125208792 manual

Grundig

Grundig 871125208792 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.