Vestamatic Time Control Easy User manual

Subject to modifications.© Vestamatic GmbH
Art.-Nr.: 85601521 F2 • Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Time Control Easy
1/2
G
Time Control Easy
Art.-no.:
01813335 Installation and Operating Instructions
Time Control Easy Art.-no.: 01813335
Shutter control for manual or automatic control
of electric shutters or lighting control.
Short description
Easy operation with up/down arrow buttons and display
Week and day program
Random function
Safety precautions
Ä– Contact a professional electrician to install the control sys-
tem, because the control system requires a power supply of
230VAC, 50 Hz.
– Check the control system for signs of mechanical damage after
unpacking. If you notice any shipping damage, do not start up
the control system and notify your supplier immediately.
– The control system should only be used for the purpose speci–
fied by the manufacturer (refer to the operating instructions).
Any changes or modifications thereof are not permissible and
will result in loss of all warranty claims.
– If the control unit or the connected sunshade cannot be oper-
ated without presenting a hazard, it must be switched off and
prevented from being switched on unintentionally.
– When performing work on the windows, controls or connected
shades, protect them against unauthorised or unintentional
operation.
Technical data
Power supply: 230VAC, 50 Hz, +/-10%
Impulse voltage withstand level: 2.5 kV
Rated power: < 1.5 W
Output (Up/Down): 230VAC, 50 Hz
Maximum load: 250VAC, 3A, cos f> 0.8 ind.
Align switching time: 180 seconds
Software class: A
Operating temperature: 0°C (32°F) to +60 °C (140°F)
Protection degree: IP20
Battery backup: 60 minutes
Dimensions (L × W × H): 80 × 80 × 45 mm, Installation in
flush-mounted boxes 60 mm Ø
at least 42 mm deep / recom. 60 mm
Colour information: similar to RAL 9016
Conformity: p
Disposal of waste
The disposal of electrical equipment and batteries in household waste
is strictly forbidden.
ÉThe symbol (dustbin crossed out, in line with WEEE Appendix IV) in-
dicates separate collection of electrical and electronic products in EU
countries. Do not dispose of the device or battery in your household
waste. Ask your town or local council about the return and collection
systems available in your area to dispose of this product.
Assembly and installation
ÄWARNING!
Risk of injury due to improper installation and commissioning.
Improper installation and commissioning may lead to personal
injury or property damage.
Therefore:
– When connecting the device, observe the currently valid VDE
standards (in particular DIN VDE 0100/0700), your local power
company’s regulations and the current accident prevention regu-
lations.
– Connect the control in accordance with the wiring diagram.
Notes for professional electricians
1. In any case ensure that the safety regulations according to DIN VDE 0105.
2. Connect the device according to the wiring diagram and attach supporting
frame to the junction box or cavity wall box.
3. Fit the device through the cover by applying gentle pressure onto the
supporting frame.
4. Switch on the power supply.
5. Check the sunshade direction by using the “Up” and “Down” buttons.
Wiring diagram

Subject to modifications.© Vestamatic GmbH
Art.-Nr.: 85601521 F2 • Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Time Control Easy
2/2
G
Time and date
Setting the time and date can be performed in any operating mode.
Please press for about 5 seconds the SET button until the time display flashes.
Day +
-
Month+
-
Year +
-
5s SET
+
-
Time
SET SET SET SET
Adjustment options
Manual mode
The shutter is driven by using the Up or Down button to the desired posi-
tion, the output for about 3 minutes should latch.
The latch can be stopped at any time by the opposite direction button or
the SET button.
Memory Function
Simplified programming option for the switching times of the daily program.
Automatic operation
In addition to the functions described in the manual mode, the roller shutter
automatically drives up or down at the pre-set operation times.
In the automatic mode, a distinction is made between three types of program:
Day program: The switching times apply for all days of the week.
Week program: For each day of the week, switching times can be set
individually.
Random program:
In addition to day and week program, the random mode
can be selected.
The switching times will vary by ± 15 minutes.
Memory function (only adjustable in daily program)
Programming the Up time. At the desired time, press the SET and the Up
button simultaneously for 6 seconds.
Programming the Down time. At the desired time, press the SET and the
Down button simultaneously for 6 seconds.
6s
SET + Up 6s
SET + Down
2s SET 3s Up + Down 2s SET +
Up + Down
Changeover
manual operation automatic operation
Changeover Day/Week program
(only in automatic operation mode)
Random generator ON of OFF
(only in automatic operation mode)
Operation modes
Programming switching times
The programming of the switching times can be performed in manual and automatic operation mode.
Please press the
SET
button for about 7 seconds until the switching time display flashes.
Day program (every day the same switching time applies)
Week program (every day a different adjustable switching time is possible, programmable only in the weekly program mode)
END
SET
SET
Switching time Up
7s SET
Switching time Down
+
-+
-
END
...
7s SET SET SET SET SET
Switching Time
Monday Up
+
-
Switching Time
Monday Down
+
-
Switching Time
Sunday Up
+
-
Switching Time
Sunday Down
+
-
END
Table of contents