1. DESCRIPTION
•Programmable load output with lighting control mode.
•Three stage battery charging (bulk – absorption – float).
•Protected against over current.
•Protected against short circuit.
•Protected against reverse polarity connection of the battery or solar array.
•Low voltage load disconnect.
•Easy to set up thanks to two digit seven segment display.
2. INSTALLATION
The display will show a ‘’12’’ if the Controller detects a 12V battery, and a “24” if
it detects a 24V battery
Do not exceed Solar and Load ratings
3. LED INDICATORS
Green LED:
Off: No sunlight or not enough sunlight. Charger off.
Fast flashing: Bulk charge.
On: Absorption charge.
Slow flashing: Float charge.
LED=Green: battery fully charged (> 12,7V)
LED=Orange: battery ok (12,4V - 12,7V)
LED=Red: battery low (11,2V - 12,4V)
LED=Flashing Red: battery fully discharged (< 11,2V)
(load output cut off level: 11,2V)
LED=ON: load output is on.
LED=OFF: load output is off.
LED=Slow flashing: Overload.
LED=Fast flashing: Short Circuit
Please note:
1. The load output will cut off in case of over load or short circuit. The load output
will attempt to restart after 30 seconds.
2. After over discharge, the load will reconnect automatically when the battery is
recharged to 13,1V / 26,2V.
3. After over discharge, the load can be reconnected manually by pressing the
on/off push button, if the battery voltage exceeds 12,6V / 25,2V.
4. SETTING THE LOAD OUTPUT
4.1 Settings
4.2 Settings description
0 Charger only
The load output is switched off permanently.
1-13 Light control + delay
The load output automatically turns on after sunset (array voltage < 4V) and the
built-in timer starts counting.
When the timer reaches the set time, or when the low voltage limit is reached,
the load output will turn off.
H Manual
The load output can be turned on and off manually with the push button.
(low voltage shutdown remains active)
C Load output controlled by battery voltage only
Load disconnect and load reconnect will be based only on battery voltage, see
section 3
L Dusk to dawn mode
Turn on delay (array voltage < 4V): 10 seconds.
Turn off delay (array voltage > 4V): 1 minute.
No timer function.
d Debug mode
Same as L mode but without delay of 10s/1min
5. SPECIFICATIONS
BlueSolar PWM-Light 12/24-5 12/24-10 12/24-20 12/24-30
Battery Voltage 12/24V with automatic system voltage detection*
Rated charge current 5 A 10 A 20 A 30 A
Recommended solar array
36 cell for 12 V / 72 cell for 24 V
Automatic low voltage load
disconnect Yes
Maximum solar voltage 28 V for a 12 V system and 55 V for a 24 V system (1)
Self-consumption < 10 mA
Overload protection
Shut down after 60 s in case of 130% load
Shut down after 5 s in case of 160% load
Short circuit: immediate shut down
Grounding Common positive
Operating temp. range -20 to +50°C (full load)
Humidity (non condensing) Max 95 %
Settings
Charge voltage 'absorption' 14.2 V / 28,4 V
Charge voltage 'float' 13.8 V / 27,6 V
Load disconnect 11,2V / 22,4V
Load reconnect 12,6V / 25,2V (manual)
13,1V / 26,2V (automatic)
Enclosure
Protection class IP20
Terminal size 5 mm² / AWG10
Weight 0,13 kg 0,15 kg
Dimension (h x w x d) 70 x 133 x 33,5 mm (2.8 x 5.3 x 1.3 inch)
Mounting Vertical wall mount Indoor only
Humidity (non condensing) Max. 95%
Operating temperature -20°C to +50°C (full load)
Cooling Natural convection
Standards
Safety IEC 62109-1
EMC EN 61000-6-1, EN 61000-6-3, ISO 7637-2
1) For 12V use 36 cell solar panels
For 24V use 72 cell solar panels
or 2x 36 cell in series
2) The controller switches to the lower float
voltage level 2 hours after the absorption voltage
has been reached.
Whenever the battery voltage becomes lower
than 13 V, a new charge cycle is triggered.
0 Load output permanently off 9
Load output turned on during 9
hours after sunset
1
Load output turned on during 1
hour after sunset
10
Load output turned on during 10
hours after sunset
2
Load output turned on during 2
hours after sunset
11
Load output turned on during 11
hours after sunset
3
Load output turned on during 3
hours after sunset
12
Load output turned on during 12
hours after sunset
4
Load output turned on during 4
hours after sunset
13
Load output turned on during 13
hours after sunset
5
Load output turned on during 5
hour after sunset
H Manual load control
6
Load output turned on during 6
hours after sunset
C
Load output controlled by battery
voltage only
7
Load output turned on during 7
hours after sunset
L Dusk to dawn mode
8
Load output turned on during 8
hours after sunset
d Debug mode
IMPORTANT
•Always connect the batteries first, in order to allow the
Controller to recognize system voltage
•Use a 12V (36 cells) solar array for a 12V battery system.
•Use a 24V (72 cells) solar array for a 24V battery system.

This manual suits for next models

3

Other Victron energy Controllers manuals

Victron energy VBC-HV User manual

Victron energy

Victron energy VBC-HV User manual

Victron energy SmartShunt IP65 User manual

Victron energy

Victron energy SmartShunt IP65 User manual

Victron energy MPPT Control User manual

Victron energy

Victron energy MPPT Control User manual

Victron energy SmartSolar MPPT 100/30 User manual

Victron energy

Victron energy SmartSolar MPPT 100/30 User manual

Victron energy CCGX User manual

Victron energy

Victron energy CCGX User manual

Victron energy VE.Bus BMS User manual

Victron energy

Victron energy VE.Bus BMS User manual

Victron energy SHS 200 MPPT User manual

Victron energy

Victron energy SHS 200 MPPT User manual

Victron energy BlueSolar MPPT 75/10 User manual

Victron energy

Victron energy BlueSolar MPPT 75/10 User manual

Victron energy BlueSolar MPPT 150/85 CAN-bus User manual

Victron energy

Victron energy BlueSolar MPPT 150/85 CAN-bus User manual

Victron energy VBC 12-24-48V User manual

Victron energy

Victron energy VBC 12-24-48V User manual

Victron energy BlueSolar MPPT 75/10 User manual

Victron energy

Victron energy BlueSolar MPPT 75/10 User manual

Victron energy BlueSolar MPPT 100/50 User manual

Victron energy

Victron energy BlueSolar MPPT 100/50 User manual

Victron energy BlueSolar MPPT 150/35 User manual

Victron energy

Victron energy BlueSolar MPPT 150/35 User manual

Victron energy CCGX User manual

Victron energy

Victron energy CCGX User manual

Victron energy Color Control GX Installation guide

Victron energy

Victron energy Color Control GX Installation guide

Victron energy CCGX Operating instructions

Victron energy

Victron energy CCGX Operating instructions

Victron energy SmartSolar MPPT 150/85 Series User manual

Victron energy

Victron energy SmartSolar MPPT 150/85 Series User manual

Victron energy BlueSolar PWM-Pro Series User manual

Victron energy

Victron energy BlueSolar PWM-Pro Series User manual

Victron energy Cerbo GX User manual

Victron energy

Victron energy Cerbo GX User manual

Victron energy EasySolar-II GX User manual

Victron energy

Victron energy EasySolar-II GX User manual

Victron energy BlueSolar MPPT 150/60-MC4 User manual

Victron energy

Victron energy BlueSolar MPPT 150/60-MC4 User manual

Victron energy BlueSolar PWM 12V/24V 30A User manual

Victron energy

Victron energy BlueSolar PWM 12V/24V 30A User manual

Victron energy BlueSolar MPPT 150/85 User manual

Victron energy

Victron energy BlueSolar MPPT 150/85 User manual

Victron energy BlueSolar 100/50A User manual

Victron energy

Victron energy BlueSolar 100/50A User manual

Popular Controllers manuals by other brands

SP ORKA HR instruction manual

SP

SP ORKA HR instruction manual

AB Quality SD3000 PLUS installation instructions

AB Quality

AB Quality SD3000 PLUS installation instructions

Sun Yeh Electrical OME Series Operation manual

Sun Yeh Electrical

Sun Yeh Electrical OME Series Operation manual

OJ Electronics OSA4-10 instructions

OJ Electronics

OJ Electronics OSA4-10 instructions

Mitsubishi FX1N-422-BD Hardware manual

Mitsubishi

Mitsubishi FX1N-422-BD Hardware manual

Estun E200P Operation manual

Estun

Estun E200P Operation manual

Belimo PRCA-S2-T Technical data sheet

Belimo

Belimo PRCA-S2-T Technical data sheet

Smartgen HGM9520N user manual

Smartgen

Smartgen HGM9520N user manual

Omron C200HX Series Replacement guide

Omron

Omron C200HX Series Replacement guide

Dantel SynchMaster 46112 Installation & operation manual

Dantel

Dantel SynchMaster 46112 Installation & operation manual

INWATER TECHNOLOGIES POINT4 RIU3 Installation and user guide

INWATER TECHNOLOGIES

INWATER TECHNOLOGIES POINT4 RIU3 Installation and user guide

M-system SC200W instruction manual

M-system

M-system SC200W instruction manual

SOMFY animeo LON 1870453 installation guide

SOMFY

SOMFY animeo LON 1870453 installation guide

Sices DST4400 user manual

Sices

Sices DST4400 user manual

Grundfos CMB-SP PM1 instructions

Grundfos

Grundfos CMB-SP PM1 instructions

Lincoln LMC 1 user manual

Lincoln

Lincoln LMC 1 user manual

Eaton EZD Series user manual

Eaton

Eaton EZD Series user manual

Zennio MINiBOX 25 v3 Technical documentation

Zennio

Zennio MINiBOX 25 v3 Technical documentation

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.