Videofied OMV-VX User manual

The OMV-VX outdoor visual verification detector is a wireless,
battery operated, motion activated outdoor camera designed for
use in Videofied® security systems.
• Powered by 3 Lithium batteries for extended battery life.
• 4 infrared LEDs for 12m night vision.
• Fully weatherproof (IP55) and temperature resistant
(-20°C/+60°C).
• 12 m (40 .) by 90 degree flexible detection pattern adjustable
to 5 ranges
• SMDA Logic for advanced temperature compensation and
environmental noise immunity.
• Easy masking of sensitive objects.
• Over spill protection
• Double Conductive Shielding against bright light disturbance.
• Transmits check-in/status signal every 8 minutes.
Product Summary
Installation Guidelines
For easier installation, programming and RF testing should be done
before mounting to check for good communication between the
control panel and all system devices.
Install the detector and other system devices in the order of the
following steps:
>Programming/RF Testing - program detector and all other
devices into the control panel and test RF communication from
each intended device location to the control panel.
>Mounting - mount detector at the tested location.
Mounting
> Use proper tools and hardware.
>Mount camera between 0.8 m to 1,2 m height.
> In order to reduce false alarms, do not aim the detector toward
vegetation, a road, or unlimited space.
> Do not cover the Fresnel lens.
DOC. - REF. 213-OMV-VX
VERSION : FEBRUARY 2017
1
INSTALL SHEET OMV-VX OUTDOOR VISUAL VERIFICATION DETECTOR

Assembly and powering
1 Untight the bottom
screw.
2 Open the OMV-VX front
cover.
3 Untight the upper and
lower screws and take off
the back box.
4 Untight the upper and
lower screws and take off
the back cover.
5 Mount the back cover on
a wall or a pole (use a metal
band with 25 mm or less in
width for pole mount).
6 Remove the battery case
cover and insert 3 Duracell
CR123A Lithium batteries
or 3 SAFT LS14500 Lithium
batteries. Close the battery
case.
The OMV-VX red LED is now on. You can assemble the detector and and take your programming keypad to pair the
OMV-VX to the Videofied® panel.
1
2
3 4
CR123A LS15400
65
Wall
mount
Pole
mount
2
INSTALL SHEET OMV-VX OUTDOOR VISUAL VERIFICATION DETECTOR

Pairing the detector
1 Using a programmed alphanumeric keypad, access to level 4.
2 To unlock and get access to the installer level 4, you need to successively enter TWO
codes (in any order) :
• INSTALLER CODE (entered during intial programming)
• USER CODE (Level3): the user must authorize the installer to get access to the
configuration of his panel.
3 Once in level 4, proceed through the menu to reach ADD A NEW DEVICE.
4 Remove the OMV-VX shield to access the program button in order to pair the
detector with the Videofied® panel. Press and release the programming button.
5 The OMV-VX red LED will flash until it is paired with the panel. When linked with
the panel, the keypad will display :
The OMV-VX is now paired with your Videofied® panel. It now needs to be configured and tested.
Tue 29/10 11:23
DISARMED LVL:1
ACCESS LEVEL
1
ACCESS LEVEL
LEVEL : 1
ACCESS LEVEL
LEVEL : 4
OK or YES
OK or YES
OK or YES
BADGE OR CODE
ACCESS LEVEL
4CONFIGURATION
GENERAL
PARAMETERS
OK or YES
AREAS AND
DEVICES
DEVICES
ADD A NEW
DEVICE
OK or YES
OK or YES
PRESS PROGRAM
BUTTON OF DEVICE
OK or YES
CAMERA (1 - 25)
RECORDED
Programming button
Shield
3
INSTALL SHEET OMV-VX OUTDOOR VISUAL VERIFICATION DETECTOR

Configuration and test
1 Once the detector is recorded, you will be able to run a radio range test to
measure the radio link between the OMV-VX and the Videofied® panel.
This test is important, it measures the strength of communication between the
device and the control panel. The keypad will display a real time radio range value
on a scale of 9.
Run the test with the detector installed or take it to its intended mounting location
and make sure that you get at least 8/9, indicating good communication with the
control panel.
To receive the most accurate results you must run the radio range test for at least
30 seconds.
Result must be 8 out of 9 or better for reliable transmission of intrusion,
sabotage and video.
2 The next step is to assign the detector to one of the four available areas,
used for delay and partial arming purposes (please refer to the Videofied® panel
installation manual for more details about the areas).
3 Enter an appropriate device name and location (up to 16 characters), then
accept. The display shows the device number and name for confirmation.
4 The functional test verifies the detection field as the OMV-VX LED flashes when
the detector dual detection PIR is triggered.
5 Once completed, you can add other devices or exit configuration mode.
RADIO RANGE TEST?
RF TEST
x/9
RF TEST
9/9
RADIO RANGE TEST?
OK or YES
Wait
OK or YES
AREA ALLOCATION
AREA: 1
ESC
NO
OK or YES
NAME + LOCATION:
OK or YES
FUNCTIONAL
DEVICE TEST ?
OK or YES
OK/YES=TEST END
OK or YES
OPERATION
COMPLETED ?
OK or YES
4
INSTALL SHEET OMV-VX OUTDOOR VISUAL VERIFICATION DETECTOR

5
INSTALL SHEET OMV-VX OUTDOOR VISUAL VERIFICATION DETECTOR
Mounting Recommendations
Please install the OMV-VX parallel to the ground with no tilt with a mounting height of 0.8 m to 1.2 m.
For optimal use, the OMV-VX shall detect a movement across the detection field and not toward the detector. The detector
shall not be pointed toward a heat source (AC units, sun or sun reflections) or moving elements such as flags, sails
or vegetation that will generate false detection.

6
INSTALL SHEET OMV-VX OUTDOOR VISUAL VERIFICATION DETECTOR
Infrared detection
The OMV-VX infrared detection has a 12 meters range
with 90° detection angle.
• SMDA Logic for advanced temperature
compensation and environmental noise immunity.
• Double Conductive Shielding against bright light
disturbance.
• 5 detection range adjustments.
Important :
It is essential to monitor the proper functioning of the infrared
detection using the FUNCTIONAL TEST feature in the panel
MAINTENANCE menu.
A red status LED lights up when the OMV-VX is detecting. Use that
test to determine the pattern of the detection field.

7
INSTALL SHEET OMV-VX OUTDOOR VISUAL VERIFICATION DETECTOR
Horizontal detection adjustment
Memory clear - product reset
To clear the OMV-VX memory in order to pair it with a new panel programming, follow the procedure below :
1. Remove the batteries from the OMV-VX.
2. Leave the battery case empty for about 30 seconds.
3. Reinsert the batteries inside the OMV-VX.
4. Follow the programming procedure described on page 2.

Disassembly
Reassembly
8
INSTALL SHEET OMV-VX OUTDOOR VISUAL VERIFICATION DETECTOR
Sensitivity adjustment
The OMV-VX detector comes with the capability of adjusting the sensitivity level of the PIR. It can improve the
detection or, on the contrary, reduce false alarms. Raising sensitivity will raise detection range, the detection field
will be larger and smaller thermal signatures will be detected. You should only use this feature when the site has
been diagnosed as needing this adjustment. It cannot be used to optimize detection as the adjustment may be too
high and generate either false alarms or missed intrusions.
Examples : Plant growth, pets.
Please note that the detector must be installed to prevent intrusions (aim the detector towards an access point),
sensitivity adjustment will have no effect if the installation doesn’t comply with the installation recommendations
described in this document.
Adjust sensitivity for the OMV-VX MotionViewer
To change the OMV-VX sensitivity, you need to change the detector name:
DEVICE
CONFIGURATION
CHANGE NAME
DEVICE
OK or YES
To select the OMV-VX
OK or YES
SENSITIVITY
ADJUSTMENT
MINIMAL
SENSITIVITY detector_name$2
LOW SENSITIVITY detector_name$1
DEFAULT
SENSITIVITY detector_name
HIGH SENSITIVITY detector_name$8
MAXIMAL
SENSITIVITY detector_name$9
Enter the detector name then enter
the $symbol at the end and the
chosen digit (without space). The
number following $ will depend on
the necessary adjustment:
$ Symbol
CMA keypad : Press @ repeatedly
until $ is displayed
XMA/XMB keypad : Press 1
repeatedly until $ is displayed
Masking lens
The OMV-VX detector is provided with a masking kit. With this kit you
can inhibit specific zones in the detection field because elements in
those zones can generate false alarms, like a tree or a road.
After disassembling the detector, detach the precut elements from
the kit and place them directly behind the lens at the detection beam
location you wish to mask.
Once it is done, put the OMV-VX elements back together as shown
below.

9
INSTALL SHEET OMV-VX OUTDOOR VISUAL VERIFICATION DETECTOR
Security notes / (FR) Notes de sécurité / (DE) Hinweise zur Sicherheit
Français
• Retirez les piles avant toute opération de
maintenance !
• Attention ! Il y a un risque d'explosion si la batterie
utilisée est remplacée par un mauvais modèle !
• Respectez la polarité lors de la mise en place des
piles !
• Ne jetez pas les batteries usagées !
Ramenez-les à votre installateur ou à un point de
collecte spécialisé.
English
• Remove the batteries before any
maintenance !
• WARNING, there is a risk of explosion if a battery
is replaced by an improper model !
• Observe polarity when setting up the batteries!
• Do not litter the batteries when they are used!
Dispose of them properly according to Lithium
Metal requirements
Deutsch
• Batterien vor jeglichen Wartungsarbeiten
entfernen!
• Vorsicht, es besteht Explosionsgefahr, wenn eine
Batterie durch eine Batterie falschen Models
ersetzt wird!
• Achten Sie beim Einsetzen der Batterien auf die
Polung!
• Entsorgen Sie Batterien nicht im normalen
Haushaltsmüll! Bringen Sie Ihre verbrauchten
Batterien zu den öffentlichen Sammelstellen.
FCC Regulatory Information for USA and CANADA
FCC Part 15.21 Changes or modifications made to this equipment not expressly approved by RSI Video Technologies may void
the FCC authorization to operate this equipment.
FCC Part 15.105 Class B
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
> Reorient or relocate the receiving antenna.
> Increase the separation between the equipment and receiver.
> Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
> Consult the dealer or an experienced radio/TV technician for help.
Radio frequency radiation exposure information according 2.1091 / 2.1093 / OET bulletin 65
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should
be installed and operated with minimum distance of 20 cm between the radiator and your body.
Cet équipement est conforme aux limites d’exposition aux rayonnements IC établies pour un environnement non contrôlé.
Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada.
Operation is subject to the following two conditions:
1 This device may not cause harmful interference, and
2 This device must accept any interference received, including interference that may cause undesired operation.
Cet appareil est conforme à la Partie 15 des règlementations de la FCC et avec la norme RSS-210 de l’Industrie Canadienne.
Son fonctionnement est soumis aux deux conditions suivantes :
1 Cet appareil ne doit pas causer d’interférences nuisibles et
2 Cet appareil doit accepter toute interférence reçue, y compris les interférences pouvant entraîner un fonctionnement
indésirable.

10
INSTALL SHEET OMV-VX OUTDOOR VISUAL VERIFICATION DETECTOR
Power requirements
Type C - 3 Lithium batteries :
• SAFT LS14500 3,6 V
• Duracell CR123A 3V
Battery life
Standard usage
(up to 5 videos per month)
4 years (LS14500)
2 years (CR123A)
High usage
(about 30 videos per month)
2 years (LS14500)
1 years (CR123A)
Standby current consumption ?? μA
Max current consumption ?? mA
Warm-up period Approx. 60 seconds
Red LED indicator
Programming, low voltage, program button, walk test, radio test, tamper
Panel compatibility W, X, VISIO and their variants
ELECTRICAL PROPERTIES
RF Wiselink® technology
Radio type Spread spectrum bidirectionnal
Operating frequency
• 868MHz - OMV-VX 200 (Europe, Africa, Asia)
• 915 MHz - OMV-VX 601 (USA, Canada, South America)
• 920 MHz - OMV-VX 702 (Australia, South America)
Transmission security AES encryption algorithm
Supervision Radio, batteries, tamper
Radio antenna Integrated
RADIO PROPERTIES
Camera
Angle Wide angle 90°
Sensor type CMOS
Daylight video Programmable : Color or B&W
Night video Automatic black & white infrared
Infrared illumination Automatic with 4 IR LEDs
Infrared illumination distance Up to 12m
Video
Video format MJPEG-WMV, MJPEG-DIFF
Frame rate 5 images per second
Video duration Programmable (10 seconds by default)
Video resolution QVGA (320x240)
Average video file size 220 kb
Image
Format JPEG
Resolution VGA (640x480)
Average image file size 8 kb
VIDEO PROPERTIES
DETECTION PROPERTIES
Detection method Passive infrared
PIR coverage 12 m 90° wide / 16 zones
PIR distance limit 12 to 2.5 m (5 levels)
Detectable speed 0.3 to 2.0 m/s
Sensitivity 2.0° C at 0.6 m/s
Detection adjustment
Detection pattern rotation 90° le or right (7 positions)
Detection range adjustment 3m to 14m (5 positions)
Masking PIR cells masking kit
Installation / Mounting
Mounting height 0.8 m to 1.2 m
Mounting support Wall, pole (outdoor or indoor)
Accessories Screw (4x 20 mm) x2, Masking seal x2
Weight 700g (without batteries)
BOX
Environmental data
Operating temperature -20°/+60°C
Max. relative humidity 95% max
Protection marking IP 55

11
www.videofied.com
INSTALL SHEET OMV-VX OUTDOOR VISUAL VERIFICATION DETECTOR
EMEA SALES
23, avenue du Général Leclerc
92340 BOURG-LA-REINE
FRANCE
E-Mail : emeasales@rsivideotech.com
North American Headquarters
1375 Willow Lake Blvd, Suite 103
Vadnais Heights, MN 55110
USA
E-Mail : usasales@rsivideotech.com
The EC declaration of conformity of
this product is available by flashing
that QR code :
915MHz (OMV-VX 601)
USA FCC Part 15C
Canada IC RSS-247 Issue 1
920MHz (OMV-VX 702)
Australia C-Tick AS/NZS4268
This symbol on the product or on its packaging indicates that this product should not be treated as household
waste. It must be handed over to the applicable collection point for the recycling of electrical and electronic
equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative
consequences for the environment and human health. The recycling of materials will help to conserve natural
resources.
For more information about recycling of this product, please contact your local municipality, your waste
disposal service or the company that installed the product.
STANDARDS AND CERTIFICATIONS
868MHz (OMV-VX 200)
Compliant with the annex IV of the R&TTE Directive 1999/5/EC
Table of contents
Other Videofied Security Sensor manuals

Videofied
Videofied XL200L User manual

Videofied
Videofied PIR ITR601 User manual

Videofied
Videofied OMV601MB User manual

Videofied
Videofied OMV 210 User manual

Videofied
Videofied ITR110 User manual

Videofied
Videofied XT-IP315 Operating instructions

Videofied
Videofied IMD 200 User manual

Videofied
Videofied OMV 611 User manual
Popular Security Sensor manuals by other brands

C & K Systems
C & K Systems Intellisense FG-1025 Series Technical note

LEGRAND
LEGRAND 675 29 quick start guide

Indyme Solutions, Inc.
Indyme Solutions, Inc. SmartDome DM9030SA Programming and installation instructions

Teletek electronics
Teletek electronics SensoIRIS GAS manual

Danatronics
Danatronics ECHO FD quick start guide

bolid
bolid S2000-IK Rev.03 instruction manual