VIP Vision SLR-B Solar Surveillance Installation Manual - Version: VIPSLRB-Q219.1
20
4.2 Default Light Settings & Period Settings
Name Remote Title Description Settings Default Settings
Battery Type Bat Type Type of battery installed in the solar panel Li_Po / Lead_acid
SLR-B Series must use Li_Po for
LiFePO4 battery, DO NOT change
this parameter
Boost Charge BoostCharge
Battery overcharge voltage. To protect the battery
from overcharging, the battery stops charging when it
is above this voltage.
10.80V ~ 32.80V
SLR-B120: 14.4V SLR-B180: 28.8V
Warning: Changing this setting
may damage the solar system.
Voltage Low Voltage Low Battery cut-off voltage. When the battery voltage falls
below this value, output will be disabled. 8.10V ~ 24.00V
SLR-B120: 10.5V SLR-B180: 21.0V
Warning: Changing this setting
may damage the solar system.
Recover
Voltage Recover Vol
Minimum voltage for the battery to start. Battery
output is enabled or resumed from cut-off when
battery voltage is above this value.
9.00V ~ 25.00V
SLR-B120: 12.0V SLR-B180: 24.0V
Warning: Changing this setting
may damage the solar system.
Power Saving PowerSaving When turned on, the battery will adjust power output
automatically to save energy. On / Off All Models: Off
Turn-On
Photovoltaic
Voltage
TurnOnPVVol
The solar panel acts as an ambient light sensor. Once
the solar panel voltage drops below the ‘Turn-on PV
Voltage’, the light turns on.
4.0V ~ 12.0V All Models: 5.0V
Output Current Output Cur Set the constant current output level. 150mA ~ 4000mA All Models: 300mA
Drive Mode DriveMode
Time Control: Set up to 5 periods of up to 9 hours
each, controls light activation. Time intervals begin after
TurnOnPVVol threshold is reached i.e: the sun has set.
Light brightness in each period is set by Light Ratio.
Move Sensor: Adds motion detection on top of 5 time
periods. The light abides by Time Control, but dims
to Idle Ratio and brightens to Light Ratio based on
movement detection.
Time Ctrl / Move
Sensor
All Models:
First Period: 2 Hours
Second Period: 3 Hours
Third Period: 7 Hours
Fourth & Fifth Periods: Not Set
Light Delay LightDelay
Countdown timer after last detection motion where
light output stays at Light Ratio setting before
switching to Idle Ratio setting.
0s ~ 120s All Models: 30 seconds.
First, Second, Third,
Fourth, Fifth Time
User-programmable light on/off schedule. Maximum 9
hours for each setting. 0.00hrs ~ 9.00hrs Sets time periods, see Drive Mode
for default settings.
Light Ratio LightRatio Set light output (%) for Time Control or when
movement is detected in Move Sensor mode. 0% ~ 100%
All Models:
First Period: 100%
Second Period: 60%
Third Period: 30%
Fourth & Fifth Periods: Not Set
Idle Ratio Idle Ratio Set light output (%) in Move Sensor mode after last
detected movement and after Light Delay elapses. 0% ~ 100%
All Models:
First Period: 30%
Second Period: 20%
Third Period: 10%
Fourth & Fifth Periods: Not Set
Morning Light MorningLight
Overrides TurnOnPVVol, making the light stay on
during the day, as per the Drive Mode Time Control
parameters.
On / Off All Models: Off
Each SLR-B Series Solar Light has default factory settings for light conguration and battery conguration. Below are
the functions of each setting in the SysCong menu and the solar system default settings . Before adjusting solar panel
and light settings, familiarise yourself with the setting denitions below.
Note: Modication to the LED light and sensor will increase power consumption and reduce battery power
available for the system.
Incorrectly editing settings can permanently damage the solar panel, battery and/or LED light. Only edit
power settings exactly as outlined in this guide. Please contact VIP Vision for more information.