19
5.2 Settings Detail
Name Remote Title Description Settings Default Settings
Battery Type BatType Type of battery installed in the solar panel Li 24 / Li12 / Li6 /
Li3 / Lead
Must use Li12 for SLR-B120 and
Li24 for SLR-B180
DO NOT change this parameter
Sensing Delay S-D-Time
Countdown timer after last detected motion where light
output stays at Light Ratio setting before switching to
Idle Ratio setting.
See the next page for more details.
No / 1S ~ 60S /
2M ~ 60M All Models: No
PV Wake Up PV-Wake TBA Yes / No All Models: Yes
Light Control
Voltage L-Con-V
The solar panel acts as an ambient light sensor. Once
the solar panel voltage drops below the Light Control
Voltage, the rst Time Period/Light Ratio will begin
after Light Control Delay has elapsed.
1 ~ 11V All Models: 5V
Light Control
Delay L-Con-DT
The amount of time that must elapse after the solar
panel voltage drops below the Light Control Voltage
before the rst Time Period/Light Ratio will begin.
5S ~60S / 2M ~
60M All Models: 60S
Over Discharge
Voltage Over-DV Battery cut-off voltage. When the battery voltage falls
below this value, output will be disabled. 2.0V ~ 17.0V All Models: 11.5V
DO NOT change this parameter
Over Discharge
Recovery Over-DRV
Minimum voltage for the battery to start. Battery
output is enabled or resumed from cut-off when
battery voltage is above this value.
2.0V ~ 17.0V All Models: 12.5V
DO NOT change this parameter
Charge Voltage Chg-Volt
Battery overcharge voltage. To protect the battery
from overcharging, the battery stops charging when it
is above this voltage.
2.0V ~ 17.0V All Models: 14.4V
DO NOT change this parameter
Charge
Recovery Chg-CR-V When the battery level falls below this value, the
battery will resume charging. 9.00V ~ 25.00V All Models: 13.8V
DO NOT change this parameter
Low Temp
Change Cold Chg Low temperature cutoff 0°C ~ -40°V All Models: -35°
Low Temp
Work Heatwork High temperature cutoff 40°C ~ 90°V All Models: 65°
Load Current LED-Cur Set the constant current output level. 0.14A ~ 10.0A All Models: 0.3A
Power Saving SmartPow When turned on, the battery will adjust power output
automatically to save energy.
High / Mid / Small
/ No / USE All Models: USE
Derating Start
Value S-M-StaV
Voltage where the control board will begin to reduce
the power output from Load Current to Minimum
Current to save energy.
7.5V ~ 17.0V All Models: 12.6
Derating End
Value S-M-EndV Voltage where the contorl board will have reduced the
power output to Minimum Current to save energy. 7.5V ~ 17.0V All Models: 11.6
Minimum
Current
Min-Cur
The minimum constant current output level All Models: 0.1A
Load
Parameters
LoadPowSet
Enter the Load Parameters section.
See the next page for more details. --
Factory Reset Re-det Reset remote back to factory parameters. Yes / No All Models: No
Each Solar Light has default factory settings for light conguration and battery conguration. Below are the functions of
each setting in the ValueSet menu and the solar system default settings. Before adjusting solar panel and light settings,
familiarise yourself with the setting denitions below.
Note: Modication to the LED light and sensor will increase power consumption and reduce battery power
available for the system.
Incorrectly editing settings can permanently damage the solar panel, battery and/or LED light. Only
edit power settings exactly as outlined in this guide. Please contact your place of purchase for more
information.