Vision ZM 1701 User manual

Federal Communications Commission Statement
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try and correct the interferene by one of the following measures:
Reorient or relocate the receiving antenna,
Increase the separation between the equipment and receiver,
Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undersired
operation.
FCC Caution: Any changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate this equipment.
Limited Warranty
Vision Guarantees that every wireless deadbolt door lock is free from physical defects in
material and workmanship under normal use for one year from the date of purchase. If
the product proves defective during this one-year warranty period, Vision will replace it
free of charge. Vision does not issue any refunds. This warranty is extended to the
original end user purchase only and is not transferable. This warranty does not apply to :
(1) damage to units caused by accident, dropping or abuse in handling, or any negligent
use; (2) units which have been subject to unauthorized repair, taken apart, or otherwise
modified; (3) units not used in accordance with instruction; (4) damages exceeding the
cost of the product; (5) transit damage, initial installation costs, removal cost, or
reinstallation cost.
For information on addional devices, plesae visit us at www.visionsecurity.com.tw
-3-
Operation Manual
ZM 1701 EU
ZM 1701 US
ZM 1701 AU
Wireless Electronic Deadbolt Door Lock
(Real Time Version)
ZM1701
V0
1001123
6B1Z-17001

Introduction
Thanks for choosing the Vision’s wireless deadbolt door lock of the home security device.
This deadbolt lock is a Z-Wave
TM
enabled device (interoperable, two-way RF mesh
networking technology) and is fully compatible with any Z-Wave
TM
enabled network.
Every main powered Z-Wave
TM
enabled device acts as a signal repeater and multiple
devices result in more possible transmission routes which helps eliminate “RF
dead-sport”.
Z-Wave
TM
enabled devices displaying the Z-Wave
TM
logo can also be used with it
regardless of the manufacturer, and ours can also be used in other manufacturer’s
Z-wave
TM
enabled networks. This deadbolt lock monitors who and when the door is
opened and closed and send Z-Wave
TM
signal to the controller. User can also control
which user code can only unlock the door at certain period of time. It is AES Encryption
Z-Wave
TM
deadbolt lock.
Product Description and Specification
* For outdoor use *
* For indoor use *
Specification: Package Content:
Protocol: Z-Wave
TM
(ZM3102N)
Frequency Range:
868.42MHz (ZM 1701 EU)
908.42MHz (ZM 1701 US)
921.42MHz (ZM 1701 AU)
Operating Range: Up to 100 feet line of sight
Operating Temp.: -10°C~ 50°C (14°F~122°F)
Battery: 4pcs xAA Energizer (E91) Batteries
1pc
2pcs
1pc
1pc
1pc
ZM 1701
Door Key
Operation Manual
Installation Manual
Drilling Template
Operation
Operating with Z-Wave
TM
Network:
If you are installing the entire Z-Wave
TM
system for the first time, please refer to the
installation guide of Z-Wave
TM
Interface Controller before installing ZM 1701.
-1-
1. Remove battery cover and observe the correct polarity before insert the batteries.
2. For “Inclusion” in (adding to) a network: Put the Z-Wave
TM
Interface Controller into
“inclusion” mode, and following its instruction to addthe ZM 1701 into your controller.
To get in the “Inclusion” mode, the distance between ZM1701 and controller is
suggested to be in one meter. Press Keypads
888
manually turn the
door lock from inside to be included. User shall hear one long beep sound and
controller shall indicate device is successfully inclusion into network.
For “Exclusion” from (removing from) a network: Set up the Z-Wave
TM
Interface
Controller into “exclusion” mode, and following its instruction to delete the ZM 1701
from your controller. Press Keypads
888
manually turn the door lock
from inside to be excluded.
3. How to setup master code and user code, how to delete user code or delete all user
code, please follow the Z-Wave
TM
Interface controller’s instruction.
4. ZM 1701 supports the following class command:
COMMAND_CLASS_DOOR_LOCK,
COMMAND_CLASS_BASIC,
COMMAND_CLASS_BATTERY,
COMMAND_CLASS_MANUFACTURER_SPECIFIC,
COMMAND_CLASS_VERSION,
COMMAND_CLASS_USER_CODE,
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SCHEDULE_ENTRY_LOCK,
COMMAND_CLASS_TIME_PARAMETERS,
COMMAND_CLASS_DOOR_LOCK_LOGGING
Operation the deadbolt lock:
1. Enter a valid user code and press to unlock the door. User shall hear one
beeps and lights green. If code is invalid, user shall hear one beeps and lights red.
2. If user press invalid code during process, please press
©
to start over.
3. ZM 1701 Electronic Deadbolt Lock supports up to 13 sets of User code (including
Master code). Each number combination can be 4 digits to 10 digits.
4. ZM 1701 Electronic Deadbolt Lock supports up to 50 schedule slots (year, month, day,
time) to Entry lock for all user in the system.
5. Visual feedback message definitions:
Valid Programming: one long beeps and lights green.
Invalid Programming: one long beeps and lights red.
Lock error: three long beeps and lights red flash.
Low battery warning:
Beeps and lights red flash 5 seconds. Please replace with good quality alkaline batteries.
Note: Please re-enter Year-Month-Date-Hour-Minute after change new batteries.
-2-
Other Vision Door Lock manuals
Popular Door Lock manuals by other brands

Dormakaba
Dormakaba Saffire LX installation instructions

Kwikset
Kwikset Signature Series Austin 720AUL 11P CP Quick installation guide

Glutz
Glutz PIATTO Fixing instructions

Schlage
Schlage Everest Service manual

Karcher Design
Karcher Design EZ180 RCBR 71 Assembly instruction

BEST ACCESS SYSTEMS
BEST ACCESS SYSTEMS B.A.S.I.S. V Service manual