MODEL: TC1 1Installation Guide
1 Channel Timer
6DEFAULT PARAMETERS
The default parameters show the factory default conditions:
- geographical zone: 1 (Australia)
- summer/winter time: settings
DIMENSIONS
218 65
91
3CONNECTION DIAGRAM
4DISPLAY DESCRIPTION
relay OFF
relay ON
Current time indication
Year, month, day
indication (displayed in
advanced programming)
ON/OFF indication blocks
Relay status
Relay Lock
Programming Menu is Active
Advanced Programming Menu
is Active
Day of the week
TC1
5INSTALLATION
7RELAY MANUAL SWITCHING
To change the status of the relay output (from ON to OFF or vice versa)
press the
key
.
Attention: the status is maintained until the button is pressed again
or until the next program switching.
To lock the current status of the relay and prevent it switching,
press the
button for >3 seconds
.
In this condition the symbol is lit.
To unlock press
button for >3 seconds
Reset to factory defaults
To reset the timer to factory default settlings,
From the main screen, press all three buttons ( PRG ) simultaneously
with a pen or similar for at least 3 seconds.
dEF (flashing) will appear on the screen,
When dEF is seen flashing, press the PRG button to confirm the reset
If the PRG is not pressed within 5 seconds, the timer returns to the main
screen without performing a reset.
DINrail mounted, electronic timer with weekly and
daily programming
This product should only be installed by a licenced electrician
in accordance with all the requirements of AS/NZS 3000
(current edition) and other relevant Standards and Regulations
Technical Specifications
Power supply 240Vac (-15% to +10%) 50/60Hz
Terminals 1 x 4mm2cable maximum
Output normally open relay
Programming
Weekly (a different program for
every day of the week), or
Daily (same program each day)
Programming resolution 30 minutes
Operating temperature -20 to +50 °C
Storage temperature -10 to +70 °C
Operating humidity -20 to 90% non-condensing
Width 1 DIN module
IP Rating IP20
Relay capacity 16A @ 240Vac
Maximum Load
LED 500 VA
Incandescent 2000 W
Fluorescent 250 VA
Low voltage halogen 1000 VA
Halogen (240 V) 2000 W
CFL 200 VA
Backup Battery life/type 4 years/Lithium CR-1632
The device comes with the backup battery inserted, therefore if
required the timer can be switched on and programmed without a
mains connection. To turn the timer on without a mains connection,
press the PRG button.
Note that when programming without a mains connection, the LED
backlight display and relay will not operate.
The backlight display will turn on when the device is mains powered and
remains on while mains is connected.
Connect the mains supply and the relay output as shown in Section 3.
16A/ 240Vac
PROGRAMMING
89
(*) summer/winter time change
If the automatic update of summer time is active (on), the change occurs
according to the set geographical zone:
Zone Start DST (+1h) End DST (-1h)
01 Australia First Sunday, October First Sunday, April
02 New Zealand Last Sunday, September First Sunday, April
Note: time change is fixed for all zones at 2:00am for the start
of DST and at 3:00am for the end of DST.
3s
Year setting Month setting Day setting
Geographical
zone setting
Operation setting**
Time setting Minutes setting Summer/winter
time change*
ADVANCED PROGRAMMING
Programming consists of 7 different
programs, one for each day of the
week.
The timer splits the 24-hour day up into 48
time-blocks, with each block 30 minutes long.
When a block is ON, the relay output is on.
Before programming, all 48 blocks are OFF.
The timer can be set to turn any combination
of the 30-minute blocks ON. Midday
Midnight
6am6pm
30-minute
block OFF
30-minute
block ON
Setting blocks to ON
Use a pen or similar to press the programming buttons.
Press the PRG button (short press) to enter programming mode. The
day indicator will flash.
Scroll through days by pressing (Monday = 1, Tuesday = 2, etc.).
Select the day required by pressing PRG. The time will indicate 00:00
(midnight).
Press the PRG button to incrementally move through the 30-minute
blocks, starting at midnight. The time will increment by 30 minutes each
time the PRG button is pressed.
If a block is required to be ON, press the button and then the PRG
button. If it needs to be OFF, just press the button PRG button again to
move to the next block. Blocks set to ON will be shown as black (see the
diagram above).
When all the required blocks are set to ON, press the PRG button for 3
seconds to return to the day selection screen.
Program other days as required.
When programming is finished, press the PRG button for 3 seconds to
return to the main screen.
1.
2.
3.
4.
5.
6.
7.
8.
Changing Blocks from ON to OFF
In programming mode, use the PRG button to move to the block required to
be changed. The block will flash.
When the block is flashing, press the button. The block will change from
ON to OFF.
1.
2.
3.
A block currently set to ON can be set to OFF as follows
10 Battery Replacement
1.
2.
3.
4.
Copy function
Choice of the
day to copy
The copy function allows you to copy programming from
one day to another.
Follow steps 1 to 3 of ‘Setting blocks to ON’ (above) to
go to the day required to be copied
Press the and buttons at the same time. ‘COPY’
appears on the display and the day flashes
Choose which day to copy to with the and buttons
Confirm with the PRG button
To copy an existing program in another day:
Display date and programs
From the main page, successively press the button to scroll through the
programs set for each day and the set date (day and month).
Programming mode will exit if no buttons are pressed within the time-out period
(40 seconds if the device is mains powered, 10 seconds if powered by the
backup battery). Any modifications are still saved.
Note
Before you access the battery compartment, disconnect mains.
So that date and time is not lost, replace the battery within one minute of
removing it.
Only use a CR-1632 type battery
Note
When the backup battery is low the
device displays and the
battery should be replaced as soon as
possible.
Operating setting
Weekly operation allows a different program on each day of the week
Daily operation runs the same program every day
The Operation setting allows the time to be changed from weekly (7)
operation (default) to daily (1) operation
(**)
From the main screen, press the key
for >3 seconds
This allows you to change:
- geographical zone of installation
- date and time,
- Summer/winter time automatic update
- Operating mode (daily or weekly)

Other Voltex Timer manuals

Voltex TC1 User manual

Voltex

Voltex TC1 User manual

Voltex TC1 User manual

Voltex

Voltex TC1 User manual

Voltex TC1 User manual

Voltex

Voltex TC1 User manual

Popular Timer manuals by other brands

ascon TT70 user manual

ascon

ascon TT70 user manual

Intermatic Grasslin talento smart B15 operating instructions

Intermatic

Intermatic Grasslin talento smart B15 operating instructions

hager EG110 Instructions for use

hager

hager EG110 Instructions for use

Orbit 57594-50 rB quick start guide

Orbit

Orbit 57594-50 rB quick start guide

Wachendorff TI327401 manual

Wachendorff

Wachendorff TI327401 manual

hager EG 172 User instruction

hager

hager EG 172 User instruction

Woods TD1000 instructions

Woods

Woods TD1000 instructions

NSi INDUSTRIES Tork RZ327 Programming instructions

NSi INDUSTRIES

NSi INDUSTRIES Tork RZ327 Programming instructions

Acroprint ESP180 quick start guide

Acroprint

Acroprint ESP180 quick start guide

ETEKCITY EDT-1USA quick start guide

ETEKCITY

ETEKCITY EDT-1USA quick start guide

Woods 50101 quick start guide

Woods

Woods 50101 quick start guide

Uponor I-35 manual

Uponor

Uponor I-35 manual

Doepke UNO operating instructions

Doepke

Doepke UNO operating instructions

CAPITAL SPORTS 10028194 manual

CAPITAL SPORTS

CAPITAL SPORTS 10028194 manual

EMKO EZM-9935 manual

EMKO

EMKO EZM-9935 manual

TFA 38.2027 operating instructions

TFA

TFA 38.2027 operating instructions

WHITLOCK INSTRUMENT DNFT-LED-PS manual

WHITLOCK INSTRUMENT

WHITLOCK INSTRUMENT DNFT-LED-PS manual

Orno OR-PRE-445 manual

Orno

Orno OR-PRE-445 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.