Vutlan VT540 User manual

VT540 / Vibration sensor
Product page: https://vutlan.com/analog-sensors/19-vt540-vibration.html
Function and purpose
Detects vibration. For installation on walls, windows, etc., the sensor controls vibration. For example, detects the breaking of
the window by an intruder if installed on the window glass.
Technical specifications
Feature Description
Sensor type Analog sensor
Dimensions 60×18×18 mm
Weight 60 g
Input RJ-12 / RJ-11 (6p4c)
Outputs RJ11 / RJ12 (6p4c)
Operating
temperature
-10 °C to +80 °C
Operating
humidity
5% to 95% (Non-Condensing)
Mounting Mounting bracket, sticker, and screws are included. Installed on the surface where possible vibration is
possible. E.g. windows, doors, etc.
Power
consumption
60mW
Max. distance m 150 m
HS Code 9025 11 800
Components Manufactured in E.U.
Daisy chain
possible
No
Package includes

Package content Description
1 Sensor
2RJ11 6P4C telephone cable
3Screw B4,2 x 16 1pc
4 Sticker 1pc
Drawing

Connecting vibration sensor
The sensor uses a standard Vutlan analog for connecting to the monitoring unit. RJS5 RJ11 sensor cable
Installation using a sticker and a bracket
Option 1.
There's a round bump at the bottom of the plastic enclosure of the sensor. It is used for fastening when the sensor is mounted
together with the on walls using a screw. In the current example, it is not needed. If you are planning to mount a device
differently, do not follow this step.
Cut the round bump using a knife so that the bottom of a plastic enclosure will be flat.

Option 2.
a) Stick the mounting sensor to the surface using the sticker.
or
b) Stick a sensor to the surface using a screw.
Option 3.
Mount the sensor to the surface using a mounting bracket. The mounting bracket and the sensor can be either attached by the
stickers or together with screws and nuts.

Analog sensor connection
Connect the analog sensor by a supplied RJ-11 (6P4C) cable to any analog port "A1 .. A8" or "Sensor" port. The determination
of the sensor type and connection will occur automatically.
6P4C RJ11 cable wiring/pinouts
If strong electromagnetic interference is present, we recommend using a 3-pair cable CAN FTP for sensor connection!

1- Yellow, 2- Green, 3- Red, 4 - Black
Colors are true for this telephone cable. Both ends match the colors and pinouts (identical).
Please refer to the RJ connectors comparison table:

Daisy chain connection
Some of the analog sensors can be connected in a daisy chain. Please refer to the article "Chain connection of analog sensors".
Maximum cable length test
Model 50m 100m 120m 15
0m
200m
VT407 AC current converter ok
VT410 DC voltage monitor
VT420 Converter 4-20mA ok
VT500 Temperature sensor ok
VT501 Outdoor temperature sensor ok
VT510 Humidity sensor x
VT530 Access sensor ok
VT540 Vibration sensor ok
VT550 Wind velocity meter x
VT560 Smoke detector ok
VT570 PIR sensor ok
VT590 Spot water detector ok
VT591 Water leak sensor ok
Extending the number of analog sensors
Using CAN extension " " it is possible to increase the number of analog sensors connected to the VT408 / Sensor extension unit
monitoring unit up to 80 sensors.

Configuring the sensitivity of the sensor
The sensor is very sensitive. At times this may prove to be too sensitive. In this case, it is possible to lower the sensor's
sensitivity:
1) Unplug the sensor from the cable.
2) Open sensor cover using a flat screw.
3) Take the two-pin jumper header out. This will lower the sensitivity slightly.
4) Close the cover and plug the sensor back in.

If the sensitivity is still too high, Vutlan can produce a custom vibration sensor will a much lesser sensitivity on demand. In
this case, please contact the sales team.
Sensor configuration
Settings tab
To configure a sensor, go to "Main menu" >> "System tree" and click on the sensor element in the tree. A modal window with
sensor properties will pop up. Change the needed settings and click "OK" or "Apply" at the bottom of the "Properties" window.

All sensors include:
1 Name The name is given by the system automatically. You can change it to anything you want.
3 ID System ID of the element.
4 Type Example: temperature, humidity, vibration.
5 Class Examples: analog, CAN, switch, discrete.
6 Hardware port The external port number on the device panel to which the sensor is connected (if the sensor is external).
All sensors have threshold controls:

In the picture above, the "Current value" equals 41.0 and is represented by the small triangle. Currently, the triangle is green
because it is situated in the "Normal" range. Hence the sensor says that "Current state" is "Normal". This value is used by the
system "Logic schemes" menu to notify the administrator or take action.
Hysteresis
Sensors have the option of setting the hysteresis state. Hysteresis can be a time, a value or it can be disabled.
If the hysteresis is set in a time, the sensor will transmit to a new state with a delay of the specified number of seconds in the
corresponding field. The time counting will begin from the moment when the measured value of the sensor has left the current
range.Each state has its own field. Which determines the time that the sensor value must continuously hold for the state .to change to the specified
If you set the hysteresis by value, the sensor transition to a new state will occur when the measured value of the sensor exits
beyond the current range, adjusted for the specified hysteresis value.
You can calibrate the sensors. Use K and B coefficients. After the calibration, please, save the values in flash memory.
To save sensor properties in the device flash memory press " " then "OK" to confirm.
Example: Why do we need to use Hysteresis
Let’s say that we have a temperature sensor. Let’s say that we have set up threshold values.
We have set the value 25.5 °C to be a threshold value between Normal/Alarm states.
If the temperature drops just below 25.5 °C You will have a “Normal” state.
If the temperature goes just above 25.5 °C You will have a “Warning” state.

Tuning the sensor value
Sensor readings can be tunned by a linear formula "y = k * x - b"
Example VT407 + HAT-100Q1 / AC current converter:
Metered current for HAT: from 0 to 100A (This means that the range equals 100, ) k = 100
The output of VT407 is 0-5V (That means that the range is equal to 5)
" " = the value that the sensor shown in WebUI when there's no current. Let's say that b b = + 0.021
You should use the following formula for HAT: 100/5*(x-y)
The expression formula would be 20*(x-0.021)
Charts tab
The charts tab shows the following:
Display
chart for
last
100
seconds
last
100
minutes
last
100
hours
last
100
days
Refresh
data
Start Poll a sensor
Reset
all
charts
Reset all Clears all saved data for the sensor.
Export
data
XML or
CSV
Exporting data through WebUI does not work for more than a couple of days and is very rough. If
you need detailed log data, use the logging of sensor values to the media:
Read more at: , System Log Sensors dump files
If the temperature goes just above 25.5 °C You will have a “Warning” state.
Sometimes the temperature may stay at 25.5 °C and jump up and down by 0.1-0.3 °C. In this case, You will get too
many notifications that the sensor is showing a Warning or Normal state.
In this case, we need to use a Hysteresis.
If the type “time” is chosen, the system will wait for a specified time before the State of the sensor is declared.
If type “value” is used, unless the temperature drops by a larger amount than specified, the sensor state will not be
declared.
Point is used as decimal separator (3.14)

Example: Using fuel tanks.
Each fuel tank has its own formula for volume vs height. Please see this useful resource for finding out such a formula.
https://www.calculatorsoup.com/calculators/construction/tank.php
In this can, You need to use non-linear formula.
Copyright:
Vutlan s.r.o. (LLC)
Remote Infrastructure Monitoring and Control
43 ul.Svornosti, 821 06 Bratislava,
Slovak Republic
www.vutlan.com
Other Vutlan Security Sensor manuals
Popular Security Sensor manuals by other brands

Risco
Risco ShockTec Plus Grade 3 installation instructions

Bircher Reglomat
Bircher Reglomat EasyMotion operating instructions

Federal Signal Corporation
Federal Signal Corporation 191XL Series Installation and maintenance manual

Abra
Abra AK-325 quick start guide

SIM
SIM SIM-04 installation instructions

Lince
Lince JOLLY Programming and operating manual