Alarmtech CD 470-I User manual

© 2020 Alarmtech www.alarmtech.se Alarmtech reserves the right to changes CD470 manual 2013en Page 1of 2
DETECTORS
Shock- and vibration detector
DATASHEET AND INSTALLATION MANUAL CD 470
DESCRIPTION
CD 470 offers reliable monitoring against attacks with
mechanical tools. The CD 470 is a chock- and vibration
detector with 3 separate detection channels: an integra-
tion channel / saw channel for weak signals with long
duration, a counting channel that senses strong impact
on the monitored surface and an explosion channel
which senses very strong signals from e.g. an explosion.
CD 470 shares design with CD 475 but has built-in relays
for the alarm and tamper outputs. This allows the CD 470
to be connected directly to the alarm central unit, this
means that no analyser unit is necessary.
CD 470-I has the same functionality as CD 470, but is also
equipped with back tamper and PC interface.
CD 470 is polarity independent, just like CD 475.
FEATURES
Relay outputs for alarm and tamper
Polarity independent for easy connection
3 separate detection channels
Cover radius up to 3m
Resistant to interference
Detailed sensitivity setting
Suitable for 24-hour monitoring
DAY and NIGHT control of LED
OPERATING PRINCIPLE
The CD 470 uses a piezoelectric sensor to monitor the vibration
signature of the mounting surface that occurs when it is
crushed or cut with tools. The signal has a special signature
with a broad spectrum and high amplitude that the electronics
detects, then opens the alarm relay and illuminates the LED.
The CD 470 has a built-in self-control and voltage monitoring.
Fault is indicated by a flashing LED (alarm relay remains closed).
The indication is controlled by a DAY and NIGHT function. With
8Vdc on the power input, DAY mode is active and LED lights up
at alarm and with pulsating shine in case of failure. At 6Vdc,
NIGHT mode is active and LED is switched off in case of alarm
or fault.
Resetting the detector after alarm can be done in two different
ways:
Disconnect power to the detector
Switch from DAY to NIGHT mode
MOUNTING
1. Loosen the screw for the cover and lift it off.
2. Select the mounting location and mark the mounting holes
with the bottom part as a template.
3. Drill with a 2-2.5 mm drill for the two supplied mounting
screws.
NOTE! A clean and smooth mounting surface under the
detector provides maximum range.
CONNECTIONS
The detector has 6 screw terminals:
#
Function
1
DC Input voltage (-) or (+)
2
DC Input voltage (-) or (+)
3
Alarm output, relay (NC)
4
Alarm output, relay (C)
5
Tamper output, relay (NC)
6
Tamper output, relay (C)
© 2020 Alarmtech www.alarmtech.se Alarmtech reserves the right to changes CD470 manual 2013en Page 2of 2
DIP-SWITCH
The DIP switch with 6 switches is used to program the functions
of the detector.
DIP Sensitivity (1 = lowest sensitivity, 8 = highest)
1
2
3
4
5
6
7
8
1
OFF
OFF
OFF
OFF
ON
ON
ON
ON
2
OFF
OFF
ON
ON
OFF
OFF
ON
ON
3
OFF
ON
OFF
ON
OFF
ON
OFF
ON
DIP Counting Channel, Number of hits
3
6
4
OFF
ON
DIP Saw/Integration Channel
Integration Channel
OFF
Integration Channel ON
5
OFF
ON
DIP Autoreset of alarm (after 4 s)
Autoreset OFF
Autoreset ON
6
OFF
ON
DETECTION RADIUS
The approximate range of different materials is given in
the table below. Note, however, that the stated numbers
only serve as guide values and are strongly dependent on
joints etc. The actual range must be determined in
practical tests.
Material
Wood/Glass/
Plywood
Brick*/
Plastering*
Steel/Concrete *
Radius
r = 2 m
r = 1 m
r =3 m
COMMISSIONING AND ADJUSTMENT
NOTE! For detector to show short blink, following procedure
must be done within 5 minutes after detector is powered on.
Commissioning and adjustment is very simple. Check that the
Autoreset is active (DIP 6 ON), the LED will then indicate when
the detector is alarmed, and after about 4 seconds, the alarm
goes out while the alarm relay closes. The counting channel
causes each received pulse to be displayed with a short flash on
the LED until the number of pulses set is reached (3 or 6), then
alarm is indicated. The alarm is indicated by a steady light as
long as the alarm relay is open.
1. Set the DIP switch to medium sensitivity, 6 hits, active saw
channel and auto reset. This is done by setting DIP 1=OFF
and DIP 2-6=ON.
2. Tap next to the detector and check that each tap is regis-
tered and that the alarm relay opens after 6 pulses.
3. Now tap relatively strongly with eg. the back of a screw-
driver on the most remote point to be protected.
4. If the pulses are not detected (short flash on the LED),
incrementally increase the sensitivity with DIP 1-3 as
shown in the table until the LED shows the received pulse.
5. If the diode instead shows alarm directly (steady light),
reduce the sensitivity incrementally with DIP 1-3 according
to the table until the LED shows the received pulse.
6. Check and adjust all connections. Finally, check that both
the alarm output and the tamper switch are received cor-
rectly at the control panel.
A fairly common mistake is to set higher sensitivity than
required, which results in false alarms. We therefore
recommend to not connect the detector in live operation
until after a few weeks so that the setting has been veri-
fied.
* When mounting on brick / plaster / concrete, the
mounting plate MP550 must be used for correct
operation.
TECHNICAL DATA
Detection radius
Up to 3m
Input voltage
8 –15 VDC (DAY mode), 6 VDC (NIGHT mode)
Max. ripple
0.2 Vpp at 12 V
Current consumption (typical) quiescent
8.0 mA (at 12 V)
Current consumption (typical) alarm
7.1 mA (at 12 V)
Alarm output
Relay (Max 50V / 120 mA), R < 30 Ω
Alarm indication
LED, DAY/NIGHT controlled
DAY and NIGHT control
DAY≥8 V, NIGHT=6 V input voltage
Alarm time
4s (when Auto Reset) or latching
Alarm reset
Input voltage below 1 V
Tamper protection
CD 470 - against cover removal
CD 470-I - against pry-off and cover removal
Tamper output
Relay (Max 50V / 120 mA), R < 30 Ω
Low voltage alarm or fault in electronics
<5V indicated by flashing LED
Environmental class (EN50130-5:2011)
II
Operating temperature range
-40°C till +55°C
Operating humidity
max. 95% RH
Housing
White ABS plastic, IP 42
Size [H x D x W]
20 x 23 x 80 mm
Approvals
EN 50131-2-8 Grade 2, SBSC Klass 2, VdS Klasse B
ORDERING INFORMATION
CD 470
E nr. 63 098 91
CD 470-I –CD 470 with back tamper and PC- connection
E nr. 63 099 92
Mounting plate MP 550
E nr. 63 098 93

This manual suits for next models

1

Other Alarmtech Security Sensor manuals

Alarmtech MC 740-E User manual

Alarmtech

Alarmtech MC 740-E User manual

Alarmtech AD 700 User manual

Alarmtech

Alarmtech AD 700 User manual

Alarmtech CD 470 User manual

Alarmtech

Alarmtech CD 470 User manual

Alarmtech MC 346 User manual

Alarmtech

Alarmtech MC 346 User manual

Alarmtech MC 746-E User manual

Alarmtech

Alarmtech MC 746-E User manual

Alarmtech CD 470 User manual

Alarmtech

Alarmtech CD 470 User manual

Alarmtech MC 740-E-M14 User manual

Alarmtech

Alarmtech MC 740-E-M14 User manual

Alarmtech GD 335 User manual

Alarmtech

Alarmtech GD 335 User manual

Alarmtech MC 470 User manual

Alarmtech

Alarmtech MC 470 User manual

Alarmtech AD 800 Manual

Alarmtech

Alarmtech AD 800 Manual

Alarmtech MC 472 User manual

Alarmtech

Alarmtech MC 472 User manual

Alarmtech MC 340 2x4,7k User manual

Alarmtech

Alarmtech MC 340 2x4,7k User manual

Alarmtech GD 375 Instruction Manual

Alarmtech

Alarmtech GD 375 Instruction Manual

Alarmtech MC 740-E User manual

Alarmtech

Alarmtech MC 740-E User manual

Alarmtech GD 370 User guide

Alarmtech

Alarmtech GD 370 User guide

Alarmtech AD 800-AM Manual

Alarmtech

Alarmtech AD 800-AM Manual

Alarmtech CD 400 User manual

Alarmtech

Alarmtech CD 400 User manual

Alarmtech MC 140 User manual

Alarmtech

Alarmtech MC 140 User manual

Popular Security Sensor manuals by other brands

STEINEL PROFESSIONAL IR Quattro DALI manual

STEINEL PROFESSIONAL

STEINEL PROFESSIONAL IR Quattro DALI manual

König Electronic SEC-CA10 manual

König Electronic

König Electronic SEC-CA10 manual

Honeywell One FireLite Alarms SD355 Installation and maintenance instructions

Honeywell

Honeywell One FireLite Alarms SD355 Installation and maintenance instructions

F&F DR-09B-IP65 manual

F&F

F&F DR-09B-IP65 manual

Safescan 45 user manual

Safescan

Safescan 45 user manual

Velleman PIR300 manual

Velleman

Velleman PIR300 manual

ELRO FH380111R instruction manual

ELRO

ELRO FH380111R instruction manual

Theben thePrema S360-101 E UP WH quick start guide

Theben

Theben thePrema S360-101 E UP WH quick start guide

Emerson Machinery Health AMS EZ 1000 operating manual

Emerson

Emerson Machinery Health AMS EZ 1000 operating manual

LEGRAND Triscan 488TRI3W instruction manual

LEGRAND

LEGRAND Triscan 488TRI3W instruction manual

AVE AF45362 manual

AVE

AVE AF45362 manual

SECO-LARM E-931CS22RRCQ installation manual

SECO-LARM

SECO-LARM E-931CS22RRCQ installation manual

AVE LUCE AMICA 44 068/3F Series quick start guide

AVE

AVE LUCE AMICA 44 068/3F Series quick start guide

Lightcloud LCLCSENSE/M/EG/A manual

Lightcloud

Lightcloud LCLCSENSE/M/EG/A manual

Niko Swiss Garde 360 DALI Secondary A-Comfort high ceiling... installation instructions

Niko

Niko Swiss Garde 360 DALI Secondary A-Comfort high ceiling... installation instructions

Prime Controls FLUXIMITY DS71 operating instructions

Prime Controls

Prime Controls FLUXIMITY DS71 operating instructions

PASCO PS-3219 BATTERY REPLACEMENT INSTRUCTIONS

PASCO

PASCO PS-3219 BATTERY REPLACEMENT INSTRUCTIONS

Niko 350-20085 manual

Niko

Niko 350-20085 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.