Wallgate Thrii-Tap+ User manual

Product Manual
ThriiTap+Hand Wash Dryer
ThriiTap+Wall Mounted Original Instructions

Revision 5
2
Product Manual ThriiTap+Wall Mounted Hand Wash
Dryer

Revision 5
3
Product Manual ThriiTap+Wall Mounted Hand Wash
Dryer
Safety Information
WARNINGS!
The appliance must be earthed.
The means for disconnection from the mains supply must be incorporated in
the fixed wiring in accordance with the wiring rules.
If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard.
The appliance must not be installed in locations where freezing can occur.
We recommend that adequate frost protection is provided in the building to
ensure freezing does not occur.
The resistivity of the water supply must not be less than 1300Ωcm.
Minimum water pressure: 100kPa.
Maximum water pressure: 1000kPa.
This appliance can be used by children aged from 8 years and above and
persons with reduced physical, sensory or mental capabilities or lack of
experience and knowledge, if they have been given supervision or instruction
concerning use of the appliance in a safe way and understand the hazards
involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without
supervision.

Revision 5
4
Product Manual ThriiTap+Wall Mounted Hand Wash
Dryer
Table of Contents
Safety Information ................................................................................................................................... 3
1. Disclaimer & Copyright Notice ............................................................................................................. 6
2. Conventions ......................................................................................................................................... 7
2.1. Warning ............................................................................................................................................ 7
2.2. Note .................................................................................................................................................. 7
2.3. Numbered procedures...................................................................................................................... 7
2.4. Bullet lists ......................................................................................................................................... 7
2.5. Menu items ....................................................................................................................................... 7
3. Glossary............................................................................................................................................... 8
4. Technical Specification ........................................................................................................................ 9
5. Overview ............................................................................................................................................ 10
6. Package Contents ............................................................................................................................. 12
7. Installing the Support Frame, Water, Waste and Electrical Connections.......................................... 13
7.1. Pre-installation Guidelines.............................................................................................................. 13
7.1.1. Wall Mounted Tap Head.............................................................................................................. 14
7.1.2. Front Fixed Wall Mounted Tap Head .......................................................................................... 15
7.2. Mounting Guidelines....................................................................................................................... 16
7.2.1. Control Module Mounting Guidelines .......................................................................................... 16
7.2.2. Soap Hook Mounting Guidelines................................................................................................. 18
7.2.3. Tap Head Mounting Guidelines ................................................................................................... 19
7.2.3.1. Wall Mounted Tap Head ........................................................................................................... 19
7.2.3.2. Front Fix Wall Mounted Tap Head............................................................................................ 21
7.3. Connecting the Control Module to the Tap head ........................................................................... 23
7.4. Mains Water Connection to Control Module .................................................................................. 27
7.5. Commissioning for use ................................................................................................................... 27
8. Programmed Settings ........................................................................................................................ 29
8.1. Operation ........................................................................................................................................ 31
8.1.1. Soap Operation ........................................................................................................................... 31
8.1.2. Dryer Operation ........................................................................................................................... 32
8.1.3. Air Heater Operation.................................................................................................................... 32
8.1.4. Hygiene Purge............................................................................................................................. 32
8.2. Advanced Adjustment..................................................................................................................... 33
8.2.1. Hygiene Purge Adjustment.......................................................................................................... 34
9. Care, Routine Maintenance, Service and Repair .............................................................................. 35
9.1. Care and Cleaning.......................................................................................................................... 35
9.2. Routine Maintenance...................................................................................................................... 36

Revision 5
5
Product Manual ThriiTap+Wall Mounted Hand Wash
Dryer
9.3. Service and Repair ......................................................................................................................... 37
9.4. Spare Parts..................................................................................................................................... 37

Revision 5
6
Product Manual ThriiTap+Wall Mounted Hand Wash
Dryer
1.Disclaimer & Copyright Notice
Every effort has been made to supply the information within this manual which is
correct. Wallgate Limited will not be liable for any damage or loss that arises if the
person installing, operating, or maintaining the unit has not read or not complied with
the manual.
In any event, and without prejudice to any warranties in Wallgate Limited’s terms and
conditions of sale, Wallgate Limited’s liability for all damages and losses (including
negligence) shall not in any circumstances exceed the amount paid by the customer
for the unit.
Wallgate reserves the right to alter, update or improve its product specification at any
time without prior notice. This manual is specific to the product that it has been
supplied with at the date of supply.
Without prejudice to any warranties in Wallgate Limited’s terms and conditions of
sale, any warranty will be invalidated if the equipment is installed or serviced by
unqualified personnel.
No part of this publication and the information contained may be reproduced,
transmitted, stored in a retrieval system, used or disclosed wholly or partly without
prior written permission from Wallgate Limited.
For full warranty details please see Wallgate Limited Terms and Conditions.
Please ensure this manual is passed to the end-user. The manual forms an integral
part of the product and should be kept for its working life. Additional copies of this
and other supporting documents are available by contacting Wallgate Ltd or by
visiting www.wallgate.com

Revision 5
7
Product Manual ThriiTap+Wall Mounted Hand Wash
Dryer
2. Conventions
Certain conventions are used in this manual to make it easier to read and
understand. It is recommended that you read and understand these warnings before
you install and commission the Wallgate ThriiTap+.
2.1. Warning
A warning with white text on a red background is used to give information about
hazards that can cause injury or death. Read and understand these warnings before
you install and commission the ThriiTap+. Failure to heed these warnings can have
serious consequences.
WARNING! This is a warning!
2.2. Note
A note with black text on a yellow background is used to draw your attention to
important and useful information.
NOTE: This is a note.
2.3. Numbered procedures
Steps in procedures are numbered, starting from 1.
1. This is step 1.
2. This is step 2 etc.
2.4 Bullet lists
2.4. Bullet lists
•A bullet list is used to give information that is not sequential.
2.5. Menu items
Menu items, submenu items and settings, where available, are given in bold.

Revision 5
8
Product Manual ThriiTap+Wall Mounted Hand Wash
Dryer
3. Glossary
The glossary lists all words, abbreviations and technical terminology used in this
manual, along with a short description of these terms.
Term
Description
ThriiTap+®
Hand Wash Unit
Tap head
The tap head refers to the user interface assembly
of the product including Air, water and soap outlet
nozzles, and the sensor
Control Module
The Control Module refers to the complete soap,
water, dryer module mounted remotely from the tap
head.
IR Sensor
The infrared (IR) sensor transmits an invisible
beam into the washbowl area so that when
interrupted by a person's hand the beam is
rebounded back to the receiver sensor. This
creates an electrical signal which rapidly activates
the hand wash cycle.
BSP
The British Standard Pipe (BSP) thread is a family
of standard screw thread types that has been
adopted internationally for interconnecting and
sealing pipe ends by mating an external (male) with
an internal (female) thread.1
Power up
The external electricity supply is provided to the
ThriiTap+.
ThriiTap+® is a registered trademark of Wallgate Limited.
1
Description sourced from Wikipedia at http://en.wikipedia.org/wiki/British_standard_pipe_thread

Revision 5
9
Product Manual ThriiTap+Wall Mounted Hand Wash
Dryer
4. Technical Specification
Weight
Item
Tap Head
Control Module
Full soap container
Total
Weight
1.5 kg
8.2 kg
2.6 kg
12.3kg
Tap Head
Dimensions
Width
Height
Length
60mm
68mm
223mm
Control Module
Dimensions
Width
Height
Depth
344 mm
252 mm
160 mm
Water Supply
Minimum pressure
Maximum rating
Inlet connection size
Dynamic
1 Bar / 100 kPa
10 Bar / 1000 kPa
½” BSP Male
Electrical
Power
requirement
220–240V 50/60Hz, single phase, 1100W.
UK plug socket.
Enclosure IP
Rating
IPX4
Regulatory
compliance
Complies with:
RoHS
LVD 2014/35/EU & EMC 2014/30/EU directives.
Flow rate
Regulated to 1.9lpm (alternative 3.75lpm regulator supplied within
box)

Revision 5
10
Product Manual ThriiTap+Wall Mounted Hand Wash
Dryer
5. Overview
The Wallgate ThriiTap+is an integrated hand wash dryer unit with automatic infra-red
sensor operation.
There are two model options that are otherwise identical except for the Tap head
mounting method. It is available as a wall mounted configuration to be installed with
the Control Module installed in a service duct on the other side of a wall, and as a
deck mounted version to be installed with the Control Module mounted below a basin
or vanity top.
These instructions deal with the wall mounted version.
When hands are placed under the centre of the tap head, an infra-red sensor
activates the hand washing and drying cycle, supplying soap (liquid or foam), warm
water and dryer-air in amounts and intervals preset as required.
The unit can be installed in a variety of wall types, (depending on configuration) and
most servicing can be carried out without removing the Control Module or tap head
from its installed position. Note, the appliance is designed to be used in commercial
areas.
Figure 1: Wall mounted tap dimensions [mm]

Revision 5
11
Product Manual ThriiTap+Wall Mounted Hand Wash
Dryer
Figure 2: Tap head outlet nozzles.

Revision 5
12
Product Manual ThriiTap+Wall Mounted Hand Wash
Dryer
6. Package Contents
Before you begin the installation, make sure that you have the following items:
✓1 Tap head
✓1 Installation instructions
✓1 Air hose –with 2 jubilee clips
✓2 Cable ties
✓1 Control Module
✓1 Soap bracket
✓1 Container of liquid soap (2.5 litres)

Revision 5
13
Product Manual ThriiTap+Wall Mounted Hand Wash
Dryer
7. Installing the Support Frame, Water, Waste and
Electrical Connections
7.1. Pre-installation Guidelines
Warning! This appliance is not to be installed in locations where freezing can
occur.
We recommend that adequate frost protection is provided in the building to ensure
freezing does not occur.
Note: When selecting a mounting position, it is important to consider the
suitability of the wall construction. It must support the weight of the assembled
unit as shown in Fig.6.
Note: Water and mains power are located on top of the Control Module.
Make an accurate opening in the wall surface according to the dimensions shown in
drawing Fig.4 noting the appropriate mounting height as detailed on the drawing
Figure 3.
Note: Complete all surface finishes such as screed, plaster or tiling before
attaching the wall mounted tap head to the wall.
Warning! All electrical work must be carried out by a qualified electrician and
should be installed in accordance with the current Nationally Approved
Regulation
The installer must:
•Provide an electrical supply of 220–240VAC 50/60Hz with a socket suitable for
the installation environment. For installations into rooms with baths or showers
the control module is to be installed into a switched fused spur. The fused spur
must be a 13Amp, double pole connection point that is local to the Control Module
(the contact separation of the fused spur switch should be at least 3mm). Earth
bonding for this type of unit must comply with the nationally approved regulations.
Warning! The socket / switched fused spur MUST be easliy accessible in case
of emergency
•Provide a mains cold water supply mounted behind a short distance from the
control module. Terminate the water supply with a suitable isolating tap. For
optimum operation, a dynamic water flow pressure of between 1 & 3 bar is
required.
Note: Request advice from Wallgate before you connect the unit to a gravity-
fed water supply.

Revision 5
14
Product Manual ThriiTap+Wall Mounted Hand Wash
Dryer
7.1.1. Wall Mounted Tap Head
Measure, mark and core a hole through wall substrate or panelling to the dimensions
shown in figure 3 below.
Figure 3: Wall Mounted Tap Head mounting dimensions.

Revision 5
15
Product Manual ThriiTap+Wall Mounted Hand Wash
Dryer
7.1.2. Front Fixed Wall Mounted Tap Head
The front fix mounting method may be used when chasing the services for the tap
into the wall. If this is the case carefully route the hoses into the chased opening
(54mm wide x 90mm deep) See 7.2.3.2 Front Fix Wall Mounted Tap Head for further
details.
Measure, mark and install wall anchors to dimensions as shown in figure 4 below.
Figure 4: Front Fixed Wall Mounted Tap Head mounting dimensions.

Revision 5
16
Product Manual ThriiTap+Wall Mounted Hand Wash
Dryer
7.2. Mounting Guidelines
7.2.1. Control Module Mounting Guidelines
The control module can be mounted either with the inputs and outputs pointed
downwards for through wall installations, or upwards for both through wall and under
basin installations.
The module is to be mounted to a flat sturdy wall via the mounting tabs. These are
bi-directional slotted for ease of installation regardless of the modules’ orientation.
The module must be fastened to the wall using mounting hardware suitable for the
wall material (to be provided by others), and the wall must be robust enough to
support the weight of the module.
Figure 5: Wall mounting of Thrii-Tap Control Module

Revision 5
17
Product Manual ThriiTap+Wall Mounted Hand Wash
Dryer
The module must have a clearance envelope of 100mm (see Fig 6).
When the module is securely mounted to the wall the power cable should be
connected to an easily accessible switched UK plug socket or switched fused spur
(depending on installation requirements). The electrical installation must be compliant
to local building and electrical regulations.
Warning! All electrical work must be carried out by a qualified electrician and
should be installed in accordance with the current Nationally Approved
Regulations.
Figure 6: Minimum control module clearance

Revision 5
18
Product Manual ThriiTap+Wall Mounted Hand Wash
Dryer
7.2.2. Soap Hook Mounting Guidelines
The soap hook can be installed remotely from the module in a position convenient for
access, and within space constraints. 0.6m of soap tube is supplied for connection
between the soap bottle and the module.
The soap hook must be fastened to the wall with appropriate fasteners for the wall
material (to be supplied by others).
Figure 7: Soap Hook installation.

Revision 5
19
Product Manual ThriiTap+Wall Mounted Hand Wash
Dryer
7.2.3. Tap Head Mounting Guidelines
7.2.3.1. Wall Mounted Tap Head
1. Remove 2x M6 nuts and mounting bracket from tap head.
2. Carefully pass tap head hoses through hole made in wall/panel before seating
tap head against the wall as shown in figure 8.
3. Thread the hoses through the mounting bracket on the rear side of the
wall/panel.
Figure 8: Front view tap head installation into wall.
Figure 9: Rear view tap head installation into wall.

Revision 5
20
Product Manual ThriiTap+Wall Mounted Hand Wash
Dryer
4. Continue by threading the mounting bracket over the two fixing studs and
against the wall.
Note: This may require two people, one to hold the tap head and the other to fix
the bracket in place.
5. Thread the 2x M6 nuts onto the studs to secure the mounting bracket into
position. Tighten bolts hand tight.
6. Check the orientation of the tap head is correctly positioned over the basin.
Also use a spirit level to check the tap head is level horizontally as this must
be the case for optimum performance.
7. Once the previous steps are complete gradually tighten each bolt equally to
5Nm.
Figure 10: Complete wall mounted tap head installation (rear fixing).
Other manuals for Thrii-Tap+
1
Table of contents
Other Wallgate Dryer manuals