d. For WPM4, move hand near Spout Adapter (2) to turn on. Remove hand and check for leaks.
Flow will turn off automatically after about 12 seconds.
14. Remove Battery (7) and turn supply back off.
15. Once solenoid has been tested, proceed to close wall. Make sure to leave access to Electric Box (5)
and to Solenoid Valve (3).
16. Connect Spout (1) to Spout Adapter (2). Refer to Diagram D.
17. Replace Battery (7) into Electrical Box (5) (+ to +).
18. Red LED (16) will light and initial calibration will begin. After about 5 seconds, Red LED (16) turns off
indicating initial calibration is complete. Replace front cover and tighten screws.
Note: Do not touch the faucet during initial calibration. If faucet is touched, remove battery and
return to Step 17.
19. Open water supply and activate faucet so water runs through Spout (1). Check all connections for
leaks.
20. Activate faucet 10 times for final calibration:
a. For WT1, touch Spout (1) to turn on. Remove hand and allow to run for 10 seconds. Touch
again to turn off. Wait 10 seconds before next activation.
b. For WTM2, touch Spout (1) to turn on. Remove hand and allow to run until it turns off
automatically, about 12 seconds. Wait 10 seconds before next activation.
c. For WP3, move hand near Spout (1) to turn on and leave hand near Spout (1) to allow to run
for 10 seconds. Remove hand to turn off. Wait 10 seconds before next activation.
d. For WPM4, move hand near Spout (1) to turn on. Remove hand and allow to run until it turns
off automatically, about 12 seconds. Wait 10 seconds before next activation.
Note: Sensor continuously learns environment as it is used. It may take up to a week of regular use to fully
calibrate.
Cleaning
1. To clean the spout, press once on White Button (16) to enter cleaning mode for 30 seconds. Red LED
(16) will begin flashing twice repeatedly.
2. During this time, spout may be cleaned without water turning on by touch or proximity.
3. When cleaning mode ends, Red LED (16) will stop flashing and operation will return to normal.
Check installation. Make sure sensor wire and solenoid wire are
not touching each other or any metal. Make sure sink and
counter are not metallic. Remove and replace battery, wait for
Red LED to turn off and follow Step 20 above.
Adjust sensitivity. Press and hold the White Button until Red LED is
permanently lit, about 10 seconds. When finger is removed, Red
LED will light in a series of flashes to indicate sensitivity level. 1
flash is the lowest and 5 flashes is the highest. Press the white