Watlow PM PLUS™ 6 • 7 • Table of Contents
Control Methods..................................................88
Output Configuration...........................................88
Auto (closed loop) and Manual (open loop) Control...................88
On-Off Control................................................89
Proportional and (P) Control.....................................90
Proportional and Integral (PI) Control..............................90
Proportional, Integral and Derivative (PID) Control....................91
Dead Band...................................................91
Variable Time Base ............................................92
Single Set Point Ramping .......................................92
Compressor Control ...........................................93
Differential Control ............................................94
Ratio Control .................................................94
Duplex Control................................................94
Motorized Valve Control ........................................94
Timer Function ...................................................94
Alarms .........................................................96
Process and Deviation Alarms....................................96
Set Points ...................................................96
Hysteresis ...................................................97
Latching.....................................................97
Silencing Alarms ..............................................98
Blocking Alarms ..............................................98
Current Sensing ..................................................98
Open and Shorted Load Circuit Detection ...........................98
Open Loop Detection...........................................99
Programming the Function Key ......................................99
Security Features .................................................99
Read Lock and Set Lock Levels...................................99
Passwords..................................................101
Modbus®- Using Programmable Memory Blocks .......................102
CIP Communications: DeviceNet or EtherNet/IP.........................103
CIP Implicit Assemblies........................................103
Compact Assembly Class...................................104
Modifying Implicit Assembly Members ........................104
PCCC - (Programmable Controller Communications Commands) ..........104
Profibus DP (Decentralized Peripherals) ..............................105
Chapter 9: Applications ...................................106
Example 1: Single Loop Control .....................................106
Example 2: Sensor Backup.........................................106
Example 3: Square Root...........................................107
Example 4: Ratio.................................................107
Example 5: Differential ............................................108
Example 6: Wet Bulb / Dry Bulb .....................................109