Welby 91807 User manual

INSTRUCTION MANUAL
Item No. 91807
Ear and Forehead
Thermometer
19.PJN174-14_GA-USA_HHD-Ohrthermometer_DSO364_28.07.14
Montag, 28. Juli 2014 14:37:38

2
5
6
6
7
7
7
9
10
10
13
13
14
15
16
17
18
19
19
21
1.0
2.0
2.1
2.2
3.0
3.1
3.3
3.4
3.5
4.0
4.1
4.2
4.3
5.0
6.0
7.0
8.0
8.1
8.2 Warning indicator if the body temperature is
too high
Commissioning of the device
Basic functions
LCD display
Designation of device parts
Scope of delivery / contents
Information on measuring the body tempera-
ture in the ear
Advantages of measuring the body tempera-
ture in the ear
What is body temperature?
Questions concerning body temperature
Information on the application of the device
Usage by children and adolescents
Environment for which the DSO 364 device is
not suited
General safety instructions
Safety instructions
Application and functionality
Definition of symbols
No. Topic Page
TABLE OF CONTENTS
D
USA
Field of application
Intended use
19.PJN174-14_GA-USA_HHD-Ohrthermometer_DSO364_28.07.14
Montag, 28. Juli 2014 14:37:38

21
22
22
23
23
23
26
28
30
32
33
33
36
37
38
39
41
44
8.3
8.4
8.5
9.0
9.1
9.2
10.0
11.0
12.0
13.0
14.0
15.0
16.0
17.0
18.0
19.0
20.0
21.0
3
Warranty
Technical specification
Malfunctions
Calibration
“Cleaning” warning indicator
Cleaning and care
Battery change and information concerning
batteries
Disposal of the device
Object temperature measurement
Measuring the temperature on the forehead
Measuring the temperature in the ear
Memory mode
Setting time and date
Display of time and date
Display / setting time and date
Setting °Celsius / °Fahrenheit
Energy saving mode
TABLE OF CONTENTS
No. Topic Page
Backlighting / torch function
USA
19.PJN174-14_GA-USA_HHD-Ohrthermometer_DSO364_28.07.14
Montag, 28. Juli 2014 14:37:38

4
In this respect, it is important that you apply the
correct technique in order to achieve precise
and reliable temperature measurements. For
this purpose, please read this instruction manual
carefully!
Fig. 1
Infrared
rays
Infrared
sensor
Eardrum
Hypothalamus
Scientific studies have shown that the ear is
ideally suited to measure the body temperature.
The body temperature is controlled by the
hypothalamus, the blood vessels of which also
supply the eardrum with blood. It is therefore
advantageous to measure the body temperature
whenever possible in the ear as shown in Fig. 1.
Measuring the body temperature in
the ear
Thank you for purchasing Ear and Forehead
Thermometer. For safe use of this product,
be sure to read and fully understand this
manual as well as the safety precautions, prior to
any use. Please keep this manual safely stored for
convenient reference. The device is intended for
the intermittent measurement and monitoring of
human body temperature by consumers in the
home.
BASIC INFORMATION
D
USA
19.PJN174-14_GA-USA_HHD-Ohrthermometer_DSO364_28.07.14
Montag, 28. Juli 2014 14:37:38

5
ATTENTION: For the users, it is dangerous to
make a self-diagnosis and to treat themselves
based on the measurement results. This may lead
to a worsening of diseases and illnesses. Under
no circumstances can this device replace any
medical consultation – if in doubt, always seek
medical advice!
PLEASE NOTE: The correct measuring technique
is very important to achieve precise measurement
results! Therefore, carefully read this instruction
manual prior to using this device!
Device with a Type B application
part: Protection against electric shock by
complying with the standards regarding
the leakage currents.
These instructions must be followed
under all circumstances!
Warning / danger: If not used
correctly, there might be the risk of
serious injury, damage and mortal
danger!
Read and follow the instruction manual!
The symbols refer to the following content:
The safety symbols shown in this instruction
manual contain information concerning the correct
use of the device and your safety.
1.0 Definition of symbols
BASIC INFORMATION USA
19.PJN174-14_GA-USA_HHD-Ohrthermometer_DSO364_28.07.14
Montag, 28. Juli 2014 14:37:38

6
This device is not intended to be used by people
(including children) with limited physical, sensory
or mental capabilities or with a lack of experience
and / or knowledge unless they would be super-
vised by a person responsible for their safety or
received instructions by such a person on how the
device is to be used.
Use the Ear and Forehead Thermometer solely
for the intended purpose: to measure the tem-
perature of the human body in the ear or on the
forehead and to measure the temperature of
liquids (such as milk or water) or surfaces.
2.1 Intended use
The Ear and F hermometer is an infrared
temperature measurement device with which you
can easily and straightforwardly carry out precise
measurements of the body temperature on the
forehead or in the ear as well as the temperature
of liquids or surfaces. An acoustic signal indicates
the end of the temperature measurement; then,
you can read the temperature measured on the
LCD display. The device can save and display the
data of the last 9 body temperature measure-
ments on the forehead or in the ear. Green / red
indicator lights signalise if the body temperature
measured is in the normal range (green) or if the
body temperature is too high (red). The torch
function facilitates orientation and application in
the dark.
orehead T
2.0 Application and functionality
BASIC INFORMATION
D
USA
19.PJN174-14_GA-USA_HHD-Ohrthermometer_DSO364_28.07.14
Montag, 28. Juli 2014 14:37:38

3.1.1
3.1.2
3.1.3
3.1.4
3.1.5
3.1.6
3.1.7 Accessories from other devices must not be
used.
Any misuse and use not in conformity with
the application must be avoided.
Please store this instruction manual during
the useful life of the product for later
reference and also hand it over if you pass
the device to third parties. Please make the
instruction manual also available to third
parties. The instruction manual is an integral
part of the device.
If you have any doubts concerning the
application of the device, you should seek
medical advice in advance.
During the measuring process, do not carry
out any other activity.
If irregularities occur during the use of the
device, you must stop the application
immediately and seek medical advice.
In case of a defect, the device must not be
used. Do not try to modify (change), dis-
assemble or repair the device or replace any
parts.
3.1 General safety instructions
3.0 Safety instructions
This device is intended to be used and applied
only in a domestic environment, but it is not
suitable for commercial usage.
2.2 Field of application
SAFETY INSTRUCTIONS
7
USA
19.PJN174-14_GA-USA_HHD-Ohrthermometer_DSO364_28.07.14
Montag, 28. Juli 2014 14:37:38

8
The device is equipped with a class 1 LED
(torch function). Do not look directly into the
LED light beam for a longer period of time
and do not point the LED light beam into the
eyes of other people or animals!
Do not store the device in places with ex-
tremely high or low ambient temperatures
(below -4 -20 °C or above 131
55 °C) or in extremely dry or damp environ-
ments, since this could result in inaccurate
measurement results.
°F / °F /
Remove the batteries from the device if it is
not used for a longer period of time in order
to prevent damage caused by leaking
batteries.
Do not open the device and do not try to re-
pair it yourself in the event of malfunctions
or damage, as this leads to the expiry of
your warranty claim. The device may only
be repaired by authorised specialist
personnel.
Do not expose the device to direct sunlight
and excessively high or low temperatures.
Use and store the device only in dry
environments free from any contamination.
In order to ensure precise measurement
results, particularly protect the infrared
sensor of the device against moisture, dirt
and damage.
Do not drop the device, do not shake it and
do not expose it to any impacts.
SAFETY INSTRUCTIONS
D
3.1.8
3.1.9
3.2.0
3.2.1
3.2.2
3.2.3
3.2.4
USA
19.PJN174-14_GA-USA_HHD-Ohrthermometer_DSO364_28.07.14
Montag, 28. Juli 2014 14:37:38

3.3.1
3.3.2
3.3.3
3.3.4
3.3.5
3.3.6 Medical electrical devices are subject to
special precautions regarding EMC (electro-
magnetic compatibility).
Keep a distance of at least 1.5 metres to
shortwave or microwave devices and / or
high-frequency (HF) surgical devices when
using the temperature measurement device.
Do not use the device on mountains higher
than 3,000 metres.
Do not use mobile phones next to the device
when carrying out the temperature measure-
ments. Please note that portable and mobile
HF (high-frequency) communication equip-
ment (e.g. mobile phones) may influence
medical electrical devices.
While using the device, it may interfere with
other electric devices or may be impaired by
other electric devices. Therefore, do not use
the device near other electric devices.
Do not use the device near highly flammable
substances or gases or near explosives.
Do not use the device in damp and wet
environments. Keep the device away from
any liquids while in use and, above all, never
immerse it in liquids.
3.3 Environment for which the
DSO 364 device is not suited
SAFETY INSTRUCTIONS
9
USA
19.PJN174-14_GA-USA_HHD-Ohrthermometer_DSO364_28.07.14
Montag, 28. Juli 2014 14:37:38

10
3.4.1
3.4.2
3.4.3
3.5.1
3.5.2
3.5.3
3.5.4 Fig. 2
correct
Keep the
infrared sensor
clean!
wrong
Do not measure the body tem-
perature in the ear if the ear is inflamed or
infected!
Do not touch the infrared
sensor and do not blow at it.
Any dirt on the infrared sensor
might lead to inaccurate
measurement results.
Keep the infrared sensor clean
and dry and avoid any damage
(see Fig. 2). This is the only
way to obtain precise measure-
ment results.
This thermometer cannot replace any
consultation or treatment! The
measurement results are only used for
comparative purposes. In the event of health
problems, it is absolutely necessary to seek
your doctor's advice!
medical
3.5 Information on the application of
the device
Keep the device out of the reach of children.
Small parts or batteries could be swallowed
by children who might then choke. Children
could hurt themselves when using the
device.
Supervise children in order to prevent them
from playing with the device.
The device must be stored out of the reach
of children and adolescents younger than 18
years.
3.4 Usage by children and
adolescents
SAFETY INSTRUCTIONS
D
USA
19.PJN174-14_GA-USA_HHD-Ohrthermometer_DSO364_28.07.14
Montag, 28. Juli 2014 14:37:38

11
3.5.5
3.5.6
3.5.7
3.5.8
3.5.9
3.6.0 Whenever possible, always measure the
body temperature in the same ear, since the
temperature might be different in the right
and left ear.
Repeat the measurements approx. every 15
minutes if the measurement results are un-
usually low or do not reflect your personal
feeling. In this case, also carry out a com-
parative oral or rectal measurement using a
conventional clinical thermometer if
possible. If in doubt, consult your doctor!
Do not start a measurement immediately if
the device was stored in a place with a great
temperature difference as compared to the
place in which the measurement is to be
performed. Both the device and the people
whose body temperature is measured should
have been in the same environment for at
least 30 minutes.
Earwax or oily skin on the forehead might
result in inaccurate measurements. There-
fore, clean the ear and / or the forehead be-
fore carrying out a measurement. After-
wards, wait for approx. 5 - 10 minutes
before measuring the temperature.
Do not perform any measurements in the
ear if you suffer from an ear disease or if
there is still water in the ear (e.g. after
having taken a shower, after swimming...).
Do not use the device if it is damaged. Using
a damaged device might result in injuries,
serious risks and inaccurate measurement
results.
SAFETY INSTRUCTIONS USA
19.PJN174-14_GA-USA_HHD-Ohrthermometer_DSO364_28.07.14
Montag, 28. Juli 2014 14:37:38

3.6.1
3.6.2
3.6.3
3.6.4
3.6.5
3.6.6
12
If the temperature of people using hearing
aids or earplugs is to be measured in the
ear, it is recommended to wait for approx.
30 minutes after such equipment has been
removed from the ear and only then carry
out a measurement of the temperature.
If the device has been held in your hand for
a long period of time, the measurement
result might be distorted by the heating of
the device resulting from this.
Please note that certain conditions might
have an impact on the measurement of the
body temperature in the ear, for example, if
the ear was covered, after swimming or
after having taken a bath, if the ear was ex-
posed to particularly high or low tempera-
tures or if you had lain on one ear for a
longer period of time.
Certain circumstances such as your age,
clothing, the outside temperature, physical
activities, your individual metabolism and
the time of the day can, as a matter of
principle, have an impact on the body
temperature.
Babies and toddlers have a higher body
temperature than adults. With increasing
age, the body temperature decreases. In
most cases, temperature fluctuations are
higher for children and occur more quickly
and more frequently.
If ear drops or other medication were
administered in one ear, the measurement of
the body temperature should be carried out
in the other ear.
SAFETY INSTRUCTIONS
D
USA
19.PJN174-14_GA-USA_HHD-Ohrthermometer_DSO364_28.07.14
Montag, 28. Juli 2014 14:37:38

13
The range of the normal body temperature differs
from one person to another and is determined by
many factors: age, sex, time of day, location and
type of the temperature measurement, level of
activity, emotional state, influence by medication
and other factors.
For instance, the body temperature of children is
approx. 0.9 0.5 °C higher than the body tem-
perature of adults. While asleep, most people have
a lower body temperature and the body tempera-
ture increases during the course of the day.
°F /
Age
Normal body
temperature in °F
Normal body
temperature in °C
0 - 2 years
97.5 - 100.4 °F
36.4 - 38.0 °C
3 - 10 years
97.0 - 100.0 °F
36.1 - 37.8 °C
11 - 65 years
96.6 - 99.7 °F
35.9 - 37.6 °C
> 65 years
96.4 - 99.5 °F
35.8 - 37.5 °C
The normal value of the body temperature is not a
fixed value, but rather a temperature range. In
general, the body temperature decreases with
increasing age. The following table shows the
respective normal temperature ranges for different
age groups:
The body temperature is the internal temperature
of the body (core temperature). It fluctuates
during the course of the day and is lowest in the
early morning and highest in the late afternoon.
4.1 What is body temperature?
4.0 Questions concerning body
temperature
BODY TEMPERATURE USA
19.PJN174-14_GA-USA_HHD-Ohrthermometer_DSO364_28.07.14
Montag, 28. Juli 2014 14:37:38

14
When measuring the body temperature, it is
important to determine, if possible, the body core
temperature corresponding to the temperature of
the inner organs. Research findings have shown
that the ear is ideally suited to measure the body
temperature, since the hypothalamus (the area of
the brain controlling the body temperature) and
the eardrum are supplied with blood via joint
blood vessels. Changes in the body temperature
can thus be determined more quickly and more
precisely than on other parts of the body. There-
fore, it is advantageous to measure the body
temperature, whenever possible, in the ear as
shown in Fig. 3 on page 15.
4.2 Advantages of measuring the
body temperature in the ear
In order to determine your own body temperature
and the body temperature of your family
members, it is recommended to perform measure-
ments of the body temperature when in a healthy
condition on three to four consecutive days at dif-
ferent times of the day. Thus, you can determine
the normal body temperature and write it down in
order to be able to compare the temperature
measurements to the normal values you have
determined when required.
Measurements performed on different parts of the
human body produce different results: Usually, the
body temperature measured rectally is approx.
0.5 0.3 °C higher than the body temperature
measured in the mouth, and this, in turn, is
higher than the body temperature
measured in the armpit.
°F /
0.5 °F / 0.3 °C
BODY TEMPERATURE
D
USA
19.PJN174-14_GA-USA_HHD-Ohrthermometer_DSO364_28.07.14
Montag, 28. Juli 2014 14:37:38

15
Fig. 3
Infrared
sensor
Infrared
rays
Eardrum
Hypothalamus
For children older than 12 months and
adults:
Gently pull the ear backwards and carefully insert
the measuring probe along the ear canal in order
to ensure that the measuring probe is directed
towards the eardrum (see Fig. 3).
For babies younger than 12 months:
Gently pull the ear slightly diagonally backwards
in order to straighten the ear canal. Carefully
insert the measuring probe into the ear canal in
order to ensure that the measuring probe is
directed towards the eardrum (see Fig. 3).
4.3 Information on measuring the
body temperature in the ear
BODY TEMPERATURE USA
19.PJN174-14_GA-USA_HHD-Ohrthermometer_DSO364_28.07.14
Montag, 28. Juli 2014 14:37:38

16
2x AAA batteries
1x
DSO
364 with stand
Ear and Forehead
Thermometer
1x instruction manual
5.0 Scope of delivery / contents
SCOPE OF DELIVERY
D
USA
19.PJN174-14_GA-USA_HHD-Ohrthermometer_DSO364_28.07.14
Montag, 28. Juli 2014 14:37:39

1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
17
LCD display
Backlighting green / red as temperature range
indicator and “Cleaning” warning indicator
MEM button to recall the measured values
saved
SET button to set date / time
( ) button to switch on the torch
( ) button to measure the temperature in the
ear
( ) button to measure the temperature on the
forehead
Measuring tip with infrared sensor
Plug-on attachment for measuring the
temperature on the forehead
Light (torch)
Battery compartment cover
Signal output opening
Table stand
DESIGNATION OF THE PARTS
6.0 Designation of device parts
USA
19.PJN174-14_GA-USA_HHD-Ohrthermometer_DSO364_28.07.14
Montag, 28. Juli 2014 14:37:39

18
1.
2.
3.
4.
5.
6.
7.
8.
Segment display of the temperature measured
Segment display for FE (fever indicator) and CL
(“Cleaning” warning indicator)
Symbol PM (“post meridiem” = in the afternoon
if the time is displayed in the 12-hour mode)
Symbol “Memory” ( ) when recalling the
memory
Symbol ( ) for “weak batteries”: change
batteries
Symbol ( ) for measuring the temperature on
an object (liquids / surfaces)
Symbol ( ) for measuring the temperature in
the ear
Symbol ( ) for measuring the temperature on
the forehead
7.0 LCD display
LCD DISPLAY
D
USA
19.PJN174-14_GA-USA_HHD-Ohrthermometer_DSO364_28.07.14
Montag, 28. Juli 2014 14:37:39

Fig. 4
Fig. 5
19
PLEASE NOTE: If the device is switched off, you
can switch it on by pressing any button. Then, the
device switches to the standby mode. In this
mode, time, date and ambient temperature are
alternately shown on the display.
PLEASE NOTE: By pressing any button, the green
backlighting of the device is activated for approx.
5 seconds.
shown in Fig. 5 initially appears for a short period
of time. Then, the display switches to the standby
mode and alternately shows the basic values 0:00
(time), l- l (month and weekday) as well as the
current ambient temperature. Now, it is recom-
mended to set first the time and date (see
Chapter 9.2 on page 23 - 25).
The two batteries have already been
inserted in the device, but are pro-
tected by means of an insulating
strip. Before using the device for the
first time, open the cover of the
battery compartment on the rear
side of the device (see also page
34). Remove the insulating strip as
shown in Fig. 4 and close the cover
of the battery compartment. Now,
the device switches on with 4 short
acoustic signals and, on the LCD
display, the full segment display as
8.1 Commissioning of the device
8.0 Basic functions
BASIC FUNCTIONS
PLEASE NOTE: In the standby mode and in the
setting mode, the display is in the correct position
USA
19.PJN174-14_GA-USA_HHD-Ohrthermometer_DSO364_28.07.14
Montag, 28. Juli 2014 14:37:39

20
ATTENTION - IMPORTANT INFORMATION
concerning the “Cleaning” warning indicator:
If, after several temperature measurements, the
device's green backlighting starts to flash for
approx. 1 minute with acoustic signal output, this
is not a malfunction, but the “Cleaning”
warning indicator! In this respect, please read
section 17.0 on page 37! If this warning indicator
is not switched off by pressing the MEM button,
this indicator will occur every time you try to per-
form a measurement and will disable subsequent
temperature measurements!
PLEASE NOTE: If “Lo” or “Hi” are shown on the
display after a measurement has been performed,
the permissible measuring range was fallen short
of or exceeded during the measurement.
PLEASE NOTE: If you wish to immediately return
to the standby mode from the setting or the
memory mode, you must simultaneously press
the ( ) “Ear measurement” and ( ) “Forehead
measurement” buttons. The device, however, also
switches to the standby mode if,
you do not press any
button within a period of approx. 1 minute or if, in
the setting or the memory mode,
within a period of approx. 30 seconds.
after a measure-
ment has been carried out,
you do not press
any button
if you hold the device in such a manner that the
front side with the buttons is facing the user. In
the temperature measurement mode and in the
memory mode, it is the other way round: In this
case, the display is in the correct position if you
hold the device in such a manner that the rear
side is facing the user.
BASIC FUNCTIONS
D
USA
19.PJN174-14_GA-USA_HHD-Ohrthermometer_DSO364_28.07.14
Montag, 28. Juli 2014 14:37:39
Table of contents
Other Welby Thermometer manuals