Speci ca ons
WPC-18000
Model No. Power Supply
(Phase-V-Hz)
Cooling Capacity
(Btu/h)
Power Consump on
(Wa s)
Rated Current
(Amps)
WPC-18000
1Phases - 220V - 60Hz
60000 6.5kW 30.2A
Model No. Weight (Net / Gross)
Lbs(kg)
Opera ng Ambient
Temperature Range
Dimensions
W x D x H - in. (mm)
WPC-18000 672/728lbs.
(305/330kg) 64~113 °F (18~45 °C)29.5 x 62.1 x 58.1
(750 x 1578 x 1478 )
Please read and save these instructions. Read carefully before attempting to assemble, install, oper-
ate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions
could result in personal injury and / or property damage! Retain instructions for future reference.
High Capacity Air Conditioner
(For Indoor & Outdoor)
by
AmeriCool Portable Air Condi oners are specialized for
“SPOT COOLING” where central cooling is imprac cal.
AmeriCool air condi oners can also be used in enclosed areas
just like conven onal air condi oners. Simple digital controller
and self-diagnos c func ons allow users to easily operate
the unit. Built-in Caster wheels enable users to move the
unit without any hassle. The unit can be installed in 5 minutes
and does not require any extra materials or cer ed technician
for installa on.
AmeriCool Portable Air Condi oner, anywhere, everywhere.
Plug-and-Go!
A er unpacking the unit, carefully inspect unit for any damage that may have occurred during transit.
Check for any loose, missing, or damaged parts.
Descrip on
Unpacking

2 3
WPC-18000
Owner’s Manual
Specicaons (Connued)
Model No. Evaporator(Cool) Air Flow
(CFM) Refrigerant Type / oz(g)
WPC-18000 1998
For a compressor:
R-410, 56.4oz (1600g)
Total: 102.8oz (3200g)
Safety Devices
Compressor overload protector, An-freezing
thermister, Automac restart (Power interrupon),
Compressor me delay program, High pressure
switch
Features
Temperature control, Self-diagnosc funcon,
Oponal drain pump kit, Washable lters,
°F( °C) display, O-mer
General Safety Informaon
Please read this manual carefully for correct installaon and usage. Please read all safeguards.
1. Transport and store the unit in an upright posion only. Leave unit in an upright posion for
at least 3 hours before rst use.
2. Always place the unit on an even, level surface.
3. Ensure the unit is connected to a grounded power supply of the correct rang / capacity.
4. The unit will operate between 18°C (64°F) ~ 45°C(113°F) depending on the temperature
seng.
5. DO NOT use this unit for other purposes that is not described in this instrucon manual.
6. DO NOT lt the unit.
7. NEVER unplug the unit under operaon.
10. DO NOT place any foreign objects on the unit.
11. DO NOT operate the unit with wet or damp hands.
12. DO NOT allow chemical substances to come into contact with the unit.
13. DO NOT operate the unit near ammable substances or vapors such as alcohols,
pescides, gasoline, etc.
DO NOT use the unit in wet environments, such as a laundry room, to avoid
the risk of electrical shock.

3
WPC-18000
Owner’s Manual
14. DO NOT unplug to turn o the unit. Always use the power switch to start and to stop the unit.
15. Always turn o the unit and unplug it before cleaning, moving or performing maintenance.
16. AVOID using adapter plugs or extension cords. If extension cord or an adapter plug is
needed , ensure they are correctly rated for the applicaon. Consult a local qualied
electrician for proper setup. Any extension cord used with this device must be rated for
a minimum of 24A.(380V)
17. DO NOT unplug the unit by pulling on the electrical cord. Keep electrical cord away from
heat sources and always completely unroll the cord to avoid overheang. If the power cord
is damaged, contact a qualied service agent, qualied electrician, or similarly qualied
person for replacement.
DO NOT operate the unit in explosive or ammable environments.
DO NOT operate a unit with a damaged power cord.
18. The lters must be used with the product at all mes. When the lters are removed for
cleaning, always ensure that the unit has been turned o and unplugged from the
electrical outlet.
19. Regularly clean the lters to maintain eciency. If the lters are not cleaned regularly,
the units output performance and eciency will decrease.
20. DO NOT operate the unit with a damaged power cord or plug,
21. Only use in the upright posion on an even, at surface. There must not be any objects
or walls within 24 inches (60 cm) from the unit.
22. Halt the unit immediately if abnormal noise or odor is detected. Contact your local
service center or manufacturer.
23. Appliance is not to be operated by children or persons with reduced physical, sensory or
mental capabilies, or lack of experience and knowledge, unless they have been given
supervision or instrucon.
24. Children must be supervised not to play with appliance.
25. The unit must be installed in accordance with naonal wiring regulaons.
26. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent
or similarly qualied persons in order to avoid a hazard. .

4 5
WPC-18000
Owner’s Manual
Assembly (WPC-18000)
COMPONENT PARTS
Front and Right Side View
Controls
Hot Air Exhaust
Top Cover
Electrical Panel
Caster
Air Inlet
I BOLT
Condensate outlet
Cold Air Inlet
Cold Air Inlet Filter
Cold Air Exhaust
Filter
Handle
Emergency Stop
Controls
Figure 2
Figure 3
Figure 4
Figure 5 Figure 6
Not in operaon In operaon

5
WPC-18000
Owner’s Manual
DUCT CONNECTIONS
Figure 7
Figure 8
Figure 9
Cool Air Duct (OUT) connecon
Cool Air in Duct (IN)
Hot Air Duct
Fork Li
Casters can be locked by
locking the break down
The Cool Air Ducts (OUT) are labeled "AIR OUT". The diameter of the duct is 400Ø.
Connect the exible air duct as following
1. Aach a exible duct to the duct collar. Use a clamp or any appropriate
apparatus around the collar to prevent any air leakage.
2. Route the exible duct as straight as possible to the desired space
without any excessive turns and pinches.
3. Please avoid any objects or walls at the end of the duct.
The Return Air In duct connecon is labeled "AIR IN".
The diameter of the duct is 400Ø. Follow the same procedures
as "Cool Air Duct (Out) connecon". If you want to use the unit
without any "AIR IN" duct, the unit will read the temperature of
the surroundings.
The Hot Air Out duct connecon is labeled "AIR OUT"
The diameter of the duct is 450 Ø and maximum duct length
is 30M. Follow the same procedures as the cool air duct
connecons.
If a forkli is needed to move the unit, put the foot of the forkli
to the forkli hole (shown in the picture: gure 8).

6 7
WPC-18000
Owner’s Manual
Installaon
MOVING THE UNIT
PLUGGING IN THE UNIT
Unlock the casters and push the unit using the side handles to a at, level surface and set the
caster brakes to the locked posion.
Check the prongs and surface of the power cord plug for dust/dirt. If dust and / or dirt are
present, wipe o with a clean, dry cloth.
Check the power cord, plug and prongs for any damages
If you suspect any damage or deterioraon, contact a qualied technician to perform replace-
ment or repair
NOTE: Make sure the AC outlet is free of dirt, dust, oil, water, or any other foreign material. The
unit is equipped with an approved NEMA plug conguraon. The appropriate outlet must
be used for each plug type.
WARNINGS REGARDING PROPER LOCATION FOR INSTALLATION
Do not use the unit in explosive environments or in areas where ammable
gas leakage may occur.
Do not use the unit in areas where it will be exposed to rain or water.
Do not use the unit in a corrosive atmosphere.
Do not use the unit above 18°C(64°F) ~ 45°C(113°F).
Do not install the unit on uneven or sloping surface. The unit may roll or
topple over even if the casters are set to the locked posion.
If the power cord or plug is damaged, repair should only be performed by
qualied electrical personnel.
Do not connect / disconnect the power cord or aempt to operate buons
with wet hands. This could result in electrical shock.

7
WPC-18000
Owner’s Manual
Operaon
CONTROL PANEL
9
1 2
5
3 4
6
87
Figure 10
1. POWER BUTTON :
Turns on/o the unit when the buon is pressed for 1 second.
2. BLOWER BUTTON :
Adjusts the fan speed from (Low) to (High) when the buon is pressed for 1 second.
NOTE: Some models only have one fan speed
3. SPOT/COOL BUTTON :
Acvates Spot Cooling mode when the buon is pressed for 1 second. Compressor can
be switched on/o
4. ROOM/COOL BUTTON :
Acvates Room Cooling mode when the buon is pressed for 1 second. Compressor can
be switched on/o
5. UP/DOWN BUTTON :
Sets target temperature in ROOM or SPOT COOL MODE.
6. ALARM :
The alarm indicator will ash when the unit detects abnormal operaon. The compressor
will stop aer the alarm and the system will stop aer 3 minutes of alarm unless there is
any acon taken to x the issue.

8 9
WPC-18000
Owner’s Manual
Operaon
CONTROL PANEL
9. EMERGENCY STOP :
Emergency stop buon immediately halts the operaon
1. Press the red buon – Unit stops
2. Inspect the unit.
3. Rotate the red buon clockwise to restart the unit
7. CURRENT TEMP :
Displays Current temperature
NOTE: Canadian version shows the temperature in Celsius.
8. TARGET TEMP :
Displays target temperature
OFF-TIMER : Press BLOWER Buon and SPOT/COOL Buon simultaneously for 2 seconds to
set o-mer. Press UP/DOWN Buon to set the mer. Aer you set o-mer, idle for 5 seconds to
save the o-mer seng. To cancel OFF-TIMER, set the mer to 0.
AUTO RESTART : If the unit turns o due to an electrical interrupon, the unit will automacally
restart when the power comes back on.

9
WPC-18000
Owner’s Manual
Maintenance
FILTER CLEANING (See Figures 11 and 12)
1. Unscrew 6 bolts on the front lter guard.
2. Slide lter up and use a vacuum cleaner to remove the dust from the lter.
3. If the lter is heavily covered with dust and dirt, use warm water and mild soap or neutral
detergent to wash the lter.
Do not use any other chemicals to clean lter.
4. Dry the lter in a shaded area before replacing it. Do not operate the unit without the lter.
5. Place the clean lter and close the lter guard.
– For your convenience, record the complete model number and product name (located on the
Product Idencaon Plate), the purchase date, purchase locaon, serial number, and war-
ranty period in the table below.
– Also, aach your purchase receipt as proof of purchase to this instrucon manual for future
reference.
– To ensure your product is covered by warranty, the complete faulty product along with your
original purchase receipt must be provided at the place of purchase.
Do not operate without the lter.
Do not operate the unit with a damaged cord or plug. Do not operate the
unit if there is any sign of malfuncon. Do not operate the unit that has
been dropped or damaged
– Unscrew 6 bolts on the
front filter guard.
– Slide filter up and use a vacuum
cleaner to remove the dust
from the filter.
– If the filter is heavily covered
with dust and dirt, warm water
and mild soap or neutral detergent
may be used to wash the filter.
Do not use any other chemicals
to clean filter.
– Dry the filter in a shaded area
before replacing it.
Do not operate the unit without
the filter.
Figure 11 – Removing Filters Figure 12 – Removal of Dust
NOTE: For eecve cooling, clean the lter at least once in 2 weeks

10 11
WPC-18000
Owner’s Manual
Maintenance (Connued)
– To ensure your product is covered by warranty, the complete faulty product along with your
original purchase receipt must be provided at the place of purchase.
Product Portable Air Condioner
Model No.
Date of Purchase
Place of Purchase
Serial No.
Period of Warranty
Customer: Please read and keep this
manual for future reference and keep
sales receipt as proof of purchase.
SELF-DIAGNOSTIC CODES (See Table 1)
The alarm will acvate when the unit detects any abnormality. It will show certain alarm code
to indicate the source of problem. The compressor and condenser fan will stop working when
alarm goes on. The evaporator fan will sll be working for 3 minutes. If no acons are taken for
3 minutes aer inial alarm, the evaporator fan will stop too. Please refer to the alarm codes in
next page and follow the soluons provided to x the unit.

11
WPC-18000
Owner’s Manual
SELF-DIAGNOSTIC ALARM CODES
Alarm Display Problem Cause Soluons
Abnormal
temperature
• Ambient
temperature is
too low
• Temperature sensor
is damaged, loose or
short/open
• Do not use the air
condioner if ambient
temperature is below
18°C (64°F)
• Contact a qualied
service agent
High Pressure
• Blocked Air lter
• Blocked exhaust duct
• Ambient
temperature is too
high
• Clean air lter
• Ensure duct is not
blocked or kinked
• Ensure the working tem-
perature is below 45°C
Abnormal
temperature
TH1(Outlet) tempera-
ture sensor has a loose
or broken connecon
Contact a qualied
service agent
Abnormal
temperature
TH2(Inlet) temperature
sensor has a loose or
broken connecon
Contact a qualied
service agent
Compressor
overloaded
• Ambient
temperature is too
high
• Unstable voltage
supply
• Defecve
• Do not use the air
condioner if ambient
temperature is above
45°C (113°F)
• Contact a qualied
service agent
• Replace the compressor
Table 1- Alarm Codes
NOTE: The alarm code will be displayed on CURRENT TEMP display

12 13
WPC-18000
Owner’s Manual
Wiring Diagram
Figure 14 - Circuit Wiring Diagram (WPC-18000)
※USE COPPER SUPPLY WIRES
WPC-18000 CL1.2
※USE COPPER SUPPLY WIRES
Power
1P AC 220V-60Hz
E
L
N
T (AC) S
CP
PU
HT
EXT
COM
EMC
L
H
TH1
TH1
OUT_TEMP
SENSOR
SEN1
SEN2
SEN3
TH2
TH2
TH3
TH3
IN_TEMP
SENSOR
ICE_TEMP
SENSOR
MC 1 OCR 1
C
FAN'
MOTOR
C
C
R
S
NO.1
COMP'
Spark
Arrestor
FND
PS (HP)
COM
COM
EXT
FU
FT
CO
COM
L - 1A
N - 1A
L
H
COM
COM
L
H
COM
CP
N-1
L-1
COM
CO
Power Remote
Control (Option)
EXT
COM
(FUSE)
(FUSE)
HIGH
PRESSURE SWITCH
MC 2 OCR 2
L - 2A
N - 2A
C
C
R
S
Spark
Arrestor
TIMER
NO.2
COMP'
COND'
MOTOR
C
N-2B
L-2B
E
PBS MCCB
TB
COM
HP
L
N
L-1
N-1
L-2
N-2
Relay
"A"
N-1
COM
COM
COM
CPCOM
COM
COM-2
"B"
Detail "B"
COM-2
CP
CP
LOW PRESSURE
SWITCH (Option)
IR/FT
RELAY RELAY
HL
N-1
(Motor측)
(PCB측)
Detail "A"
COM HL N-1
HG
HG
Solenoid
Valve
(Hot Gas Bypas)
HG
HG
NO.2 NO.1
COM-2
HG
Emergency Switch

13
WPC-18000
Owner’s Manual
TROUBLESHOOTING
Symptom Possible Cause(s) Soluons
Unit does not start.
1. Check the power supply 1. Reset the circuit breaker and
restart the unit
2. Check whether the
power cord is
connected
2. Connect power cord
No cold air from the cold
air outlet
1. The lter is dirty and air
ow is blocked
1. Clean the lter
2. Compressor will not
work if the unit is
turned on and o too
quickly
2. Wait 2 minutes aer unit is
turned o before turning the
unit back on.
3. Ambient temperature is
too high
3. The temperature of the com-
pressor can be extreme hot
when the ambient temperature
is too high. The compressor will
not work unless the ambient
air temperature is within the
acceptable operang range of
the unit
Can hear water owing
aer the compressor is
turned o
Normal operaon Not a
defect
It is common to hear coolant ow-
ing aer the unit turns o

14 15
WPC-18000
Owner’s Manual
OBTAINING SERVICE
If the Weltem High Capacity Air Condioner by AmeriCool requires Service:
1.
Use the TROUBLESHOOTING secon in this manual to eliminate obvious causes.
2. Verify there are no circuit breakers tripped.
3.
Call your dealer for assistance. If you cannot reach your dealer, or if they cannot resolve the
problem, call AmeriCool Technical Support at 888-726-6158 Please have the following informa-
on available BEFORE calling the Technical Support Department:
a. Your name and address.
b. The serial number of the unit.
c. Where and when the unit was purchased.
d.
All of the model informaon about your Weltem High Capacity Air Condioner by
AmeriCool.
e. Any informaon on the failure, including LED’s that may or may not be illuminated.
f.
A descripon of the protected equipment, including model numbers if possible.
SHIPPING LIST
• (1) High Capacity Air Condioner
• (1) Owner’s Manual

15
PB
Owner’s Manual
LIMITED WARRANTY
AmeriCool warrants all AmeriCool products to be free from defects in materials or workmanship,
under normal use and service, for a period of 12 months from the date of purchase to the end user
(original invoice must be provided). AmeriCool warrants that the compressor will be free from
defects in materials and workmanship for 12 months from the date of purchase to the end user.
AmeriCool’s obligaon under this warranty is limited to the repair or replacement at its opon,
of any part or parts, which, upon Ameriool’s examinaon are shown to be defecve, or at Ameri-
Cool’s opon, the return of the purchase price to the purchaser.
Correcon of such defects by repair or replacement, or at AmeriCool’s opon, the return of the
purchase price shall constute fulllment of warranty obligaons to the purchaser. This warranty
does not cover defects or malfuncons which result from causes beyond AmeriCool’s control,
including, without limitaon,(i) unusal physical or electrical stress:(ii) accident, neglect, abuse,
misuse or other abnormal use; (iii) failure to perform roune maintenance in accordance with
AmeriCool’s recommended procedures; (iv)normal wear and tear; (v) repairs or aempted repairs
by an unauthorized person; (vi) modicaons or alteraons to the Products; (vii) use with parts or
devices not supplied or approved by AmeriCool (viii) improper installaon or service; (ix) shipping
damage to any units or spare parts during shipping. This includes and is not limited to compres-
sors, evaporators and condenser coils. This warranty shall extend only to the original end-user and
shall be void if any labels or other idenfying marks permanently axed to Products when shipped
by AmeriCool are removed, altered, defaced or obliterated.
TO THE EXTENT PERMITTED BY LAW, THIS WARRANTY, AS LIMITED HEREIN, SHALL BE IN LIEU OF
AND EXCLUSIVE OF ALL OTHER WARRANTIES, EITHER EXPRESSED OR IMPLIED, ON THE PART OF
AMERICOOL INC., OR WELTEM CO.,LTD. WHETHER ARISING FROM LAW, COURSE OF DEALING, US-
AGE OF TRADE, OR OTHERWISE, INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTY OF
MERCHANT-ABILITY OR FITNESS OF A PARTICULAR PURP OSE OR ANY LIABILITY FOR COMMERCIAL
LOSSES BASED UPON NEGLIGENCE OR MANUFACTURER’S STRICT LIABILITY. EXCEPT AS EXPRESSLY
PROVIDED HEREIN,NEITHER AMERICOOL, INC., NOR WELTEM CO., LTD. WILL, IN ANY EVENT, BE
LIABLE FOR LOST PROFITS, COSTS OF PROCESSING,INJURY, GOODWILL, OR ANY OTHER CONSE-
QUENTIAL DAMAGES OF ANY KIND ARISING FROM BREACH OF THIS WARRANTY.
Printed in January, 2021
Manufactured in Weltem Co., Ltd.,
154, Jayumuyeok 3-gil, Masanhoewon-gu, Changwon-City, Gyeongsangnam-do,
Republic of KOREA 51340 www.weltem.com
Distributed by Americool,Inc. In the USA (Tel.888-726-6158)
WWW.AMERICOOLLLC.COM
WPC-18000
Table of contents
Other Weltem Air Conditioner manuals

Weltem
Weltem WPC-5000 User manual

Weltem
Weltem AmeriCool WPC-23000 User manual

Weltem
Weltem Icen WPC-7000 User manual

Weltem
Weltem Icen WPC-23000 User manual

Weltem
Weltem Americool HPC-3000 User manual

Weltem
Weltem WPW-4000 User manual

Weltem
Weltem Icen WPC-9000 User manual

Weltem
Weltem AMERICOOL WPC-36003 User manual

Weltem
Weltem AmeriCool WMC-2500 User manual

Weltem
Weltem WPC-6000 User manual