9
ACHIEVING 2% LOW
LEAKAGE RATE
Ensure that the Neoprene gasket with PSA remains intact on all
surfaces that the access panels are secured to. These surfaces
are the entire length of the wrapper and areas between the upper
tie plate, upper and lower access panels. Check that the upper
access panel breaker insert gasket is intact and that the flowrator
gasket is installed on the lower access panel. An additional drain
hole cover is required.
WAHMS MOTOR
Motor Speed Adjustment
The motors in all WAHMS are multispeed PSC motors. The color
of the wire coming from the motor to the “COM” terminal on the
control board defines in which speed the motor will operate. The
black wire represents high speed, the red wire represents low
speed and the blue wire (select models only) represents medium
speed.
To change speeds, remove the wire attached to the COM
terminal on the control board, and swap it with the wire on
terminal M1 or M2 with the color that will give the desired speed.
NOTE: On some models, not all speed taps are allowable for
certain electric heat applications. Refer to the air handler series
and ratings plate for minimum speed.
NOTE: Assumes dry coil with filter in place; SCFM correction for
wet coil = 4% (208V/240V).
WAHME MOTOR
The WAHME air handler features an energy efficient blower
motor. The motor is a constant torque motor with very low power
consumption. The motor is energized by 24V AC. Adjust the CFM
by changing the 24V AC leads to the desired speed on the
terminal block.
The WAHME motor blower speed is programmed to deliver
adequate airflow at rated external static pressure and with
60-second off time delay. For details, refer to the specification
sheet applicable to your model.
CFM Delivery
The following table shows the CFM speed tap settings for the
WAHME.
CFM Delivered Against External
Static Pressure
Model Speed 0.1" 0.2" 0.3" 0.4" 0.5"
WAHMS1824P4* High 1,155 1,090 1,025 950 895
Medium 940 890 860 815 755
Low 695 665 650 610 550
WAHMS1931P4* High 1,135 1,085 1,025 965 915
Medium 860 825 780 750 680
Low 600 570 545 500 465
WAHMS3030P4* High 1,385 1,315 1,240 1,155 1,065
Medium 1,340 1,290 1,230 1,140 1,050
Low 1,075 1,030 980 910 840
WAHMS3636P4* High 1,310 1,240 1,155 1,090 1,020
Medium 1,270 1,210 1,140 1,075 980
Low 1,045 1,005 955 885 805
WAHMS3642P4* High 1,700 1,660 1,625 1,545 1,505
Medium 1,500 1,440 1,400 1,350 1,345
Low 1,330 1,300 1,250 1,230 1,220
WAHMS3743P4* High 2,065 2,000 1,925 1,860 1,780
Medium 1,685 1,635 1,550 1,470 1,410
Low 1,490 1,425 1,345 1,280 1,205
WAHMS4860P4* High 2,150 2,120 2,070 2,000 1,940
Medium 1,940 1,930 1,905 1,860 1,790
Low 1,610 1,600 1,590 1,575 1,550
WAHMS4961P4* High 2,150 2,105 2,040 1,970 1,880
Medium 1,960 1,935 1,895 1,825 1,750
Low 1,670 1,625 1,585 1,525 1,455
CFM Delivered Against External
Static Pressure
Model Speed
Tap 0.1" 0.2" 0.3" 0.4" 0.5"
WAHME1830P4 1 700 670 650 595 510
2 820 785 765 745 705
3 920 900 850 840 815
4 1,075 1,055 1,015 975 960
5 1,130 1,115 1,085 1,040 1,000
WAHME3137P4 1 1,060 865 600 515 420
2 1,105 910 795 745 690
3 1,165 1,070 1,020 960 915
4 1,285 1,240 1,195 1,140 1,100
5 1,435 1,395 1,350 1,315 1,265
WAHME4260P4 1 1,445 1,275 1,175 940 855
2 1,545 1,405 1,325 1,260 1,145
3 1,660 1,610 1,555 1,490 1,415
4 1,905 1,870 1,810 1,750 1,695
5 2,115 2,070 2,000 1,965 1,915
CFM Delivered Against External
Static Pressure
Model Speed 0.1" 0.2" 0.3" 0.4" 0.5"