Whirlpool 8535840 User manual

Part No. 8535840
Installation Instructions
IMPORTANT:
Read and save these
instructions.
Installer: Leave Installation Instructions with
homeowner.
Homeowner: Keep Installation Instructions for
future reference. For best performance,
install dryer according to Installation
Instructions. Failure to complete
installation as instructed could void
warranty.
Save Installation Instructions for local
inspector’s use.
Have questions about your dryer?
Call your dealer or local authorized service company.
When you call, you will need the dryer model number and serial
number. Both numbers are on the model/serial rating plate located in
the door well behind the dryer door and on front of opening.
Record the numbers here for handy reference:
Model No.
Serial No.
Electric Dryer

2
Before you begin... Tools needed for
installation
Parts supplied for
installation
• level
• gloves
• adjustable wrench that opens to
1" or 1" hex-head socket wrench
• flat-blade screwdriver
• #2 Phillips screwdriver
• safety glasses
• tin snipes (new vent installation)
• caulking gun and compound
• wire strippers (direct wire
installation)
4 leveling legs
Remove parts
package from dryer
drum. Check that all
parts were included.
Explosion Hazard
Keep flammable materials and
vapors, such as gasoline, away
from dryer.
Place dryer at least 18 inches
above the floor for a garage
installation.
Failure to do so can result in
death, explosion, or fire.
WARNING
Your safety and the safety of
others are very important.
We have provided many important
safety messages in this manual
and on your appliance. Always read
and obey all safety messages.
This is the safety alert
symbol.
This symbol alerts you to
potential hazards that can kill or
hurt you and others.
All safety messages will follow the
safety alert symbol and either the
word “DANGER” or “WARNING”.
These words mean:
You can be killed or seriously
injured if you don’t follow
instructions.
You can be killed or seriously
injured if you don’t immediately
follow instructions.
DANGER
WARNING
For proper drying
performance:
The location must provide:
• Protection from weather and
water: Do not store or use dryer
where it will be exposed to water and
weather.
• Room temperature above 45°F: If
room temperature is below 45°F,
automatic cycles may not shut off.
• Level floor: Maximum slope under
entire dryer should not be more than
1 inch. If slope is greater than 1 inch,
install Extended Dryer Feet Kit, Part
No. 279810. Clothes may not tumble
properly and automatic sensor cycles
may not operate correctly if dryer is
not level.
• Sturdy floor to support dryer weight
of 175 pounds.
It is your responsibility to:
• Observe all governing codes and
ordinances.
• Check code requirements: Some
codes limit or do not permit
installation of clothes dryers in
garages, closets, mobile homes or
sleeping quarters. Contact your local
building inspector.
• Comply with the installation
specifications and dimensions.
• Consider spacing requirements for
companion appliances.
• Properly install dryer.
• Check that you have everything
necessary for proper installation.
• Contact a qualified installer to insure
that the electrical installation meets
all national and local codes and
ordinances.
All safety messages will tell you
what the potential hazard is, tell you
how to reduce the chance of injury,
and tell you what can happen if the
instructions are not followed.
Check that you have everything
necessary for correct installation.
Proper installation is your
responsibility.

3
Parts needed for
installation
Check local codes and see electrical
and venting requirements, Panels A
and B, before purchasing parts.
Determine if you will need to purchase
a power supply cord kit or power
supply cable.
Electrical
If using a power supply cord:
Dryer power supply cord must be:
• U.L.-listed
• 120/240-volt minimum
• 30-ampere
• Type SRD or SRDT
• At least 4 feet long
The wires that connect to the dryer
must end in ring terminals or spade
terminals with upturned ends.
The receptacle must be located within
3 feet of the top, back center of the
control console.
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to do so can result in death or
fire.
WARNING
Venting system
Four-inch heavy metal exhaust vent
and clamps must be used. Dura Safe™
vent products are recommended.
Dura Safe vent products can be
purchased from your dealer or by
calling Whirlpool Parts & Accessories
1-800-442-9991, Mon-Fri: 8am to 9pm
(CST), Sat: 9am to 4:30pm (CST).
Visit our internet site at
http://www.whirlpoolappliances.com/
accessories
See Page 11 for more information.
Exhaust hood
Do Not use exhaust hoods with
magnetic latches.
4" 4" 2-1/2"
Preferred Acceptable
Mobile home installations
require:
• Mobile Home Installation Kit, Part
Number 346764*
• Metal exhaust system hardware*
Floors sloped greater than
1 inch:
Require Extended Dryer Feet Kit, Part
No. 279810*.
*Available for purchase from your
dealer.
If your outlet
looks like this:
Choose this
power supply cord:
4-wire
receptacle
(14-30R)
4-wire power supply cord
with ring or spade terminals
and U.L.-listed strain relief
3-wire power supply cord
with ring or spade terminals
and U.L.-listed strain relief
3-wire
receptacle
(10-30R)
If connecting by direct wire:
Power supply cable must match power
supply (4-wire or 3-wire) and be:
• flexible armored or non-metallic
sheathed copper cable (with ground
wire). All current-carrying wires must
be insulated. See Panels D and E.
• 10-GAUGE SOLID COPPER WIRE.
(Do not use aluminum.)
• at least 4 feet long.

4
0"* 0"*
15"
* Wall, door and floor molding may require
additional spacing.
Recessed area
installation
Closet/confined area
installation
3"
3"
24 sq.in.**
Front view
1"
closet door
** Minimum top and bottom air openings for
closet door.
*** External exhaust elbow requires
recommended spacing.
Side view
14"
max.
spacing
5" is recommended ***
0" is minimum
• A clothes dryer produces
combustible lint and must be
exhausted outdoors.
• If codes permit, dryer may be
installed in a recessed area or closet
using dimensions shown.
If a closet door is installed: The
minimum unobstructed air openings
are required. Louvered doors with
equivalent air openings are
acceptable.
Installation clearances.
Use recommended clearance for
easier installation.
Recommended/minimum
Back – 5"/0"
Sides – 1"/0"
Top –18"/15"
Front – 1"/1"
Dryer dimensions
14"
power supply
cord/cable
strain relief
terminal block
cover
The dryer door
extends 14" from the
front of the dryer
when fully opened.
29-1/4" (models with flush
mounted door handle)
30-1/4" (models with extended
mounted door handle)
43-1/8"
11"
38-1/4"
27"
Dimensions shown with feet extended 1"
from bottom of dryer.
*Most installations will require at least 5"
clearance behind the dryer for the dryer vent.
• Dimensions are in inches and are the
minimum allowable.
• Additional spacing should be
considered for ease of installation
and servicing. Companion appliance
spacing should also be considered.
Installation clearances.
Use recommended clearance for
easier installation.
Recommended/minimum
Back – 5"/0"
Sides – 1"/0"
Top –18"/15"
Front view
48 sq.in.**
WARNING — To reduce the risk of fire
this appliance MUST BE EXHAUSTED
OUTDOORS

5
Electrical
requirements
Electrical Shock Hazard
Plug into a grounded 3-prong
outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these
instructions can result in death,
fire, or electrical shock.
WARNING
If codes permit and a separate
ground wire is used, it is
recommended that a qualified
electrician determine that the
ground path is adequate.
Important: Observe all governing
codes and ordinances.
A four-wire or three-wire, single phase,
120/240-volt, 60-Hz, AC-only, electrical
supply (or four-wire or three-wire,
120/208-volt if specified on
model/serial rating plate) is required
on a separate 30-ampere circuit, fused
on both sides of the line. A time-delay
fuse or circuit breaker is
recommended.
Recommended ground
method
It is the personal responsibility and
obligation of the customer to contact a
qualified electrician to assure that the
electrical installation is adequate and
is in conformance with the National
Electrical Code, ANSI/NFPA 70 —
latest edition* and all local codes and
ordinances.
Copies of the standards listed may be obtained
from:
* National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
Exhaust requirements
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions
can result in death or fire.
WARNING
• Do Not use non-metal flexible vent,
or exhaust hoods with magnetic
latches.
• Do Not exhaust dryer into any gas
vent, chimney, furnace, cold air vent,
wall, ceiling, concealed space of a
building, attic or crawl space, or any
other vent used for venting.
• Do Not install flexible vent in
enclosed walls, ceilings or floors.
Important: Observe all governing
codes and ordinances.
Exhaust your dryer to the outside.
Moisture and lint indoors may cause:
• Lint to gather around the dryer where
it can be fuel for a fire.
• Moisture damage to woodwork,
furniture, paint, wallpaper, carpet, etc.
• Housecleaning problems and health
problems.
Dura Safe™ venting products are
recommended and are available
from your dealer.
Four-inch diameter vent must be
used.
Use a heavy metal vent. Do Not use
plastic or metal foil vent.
Rigid metal vent is recommended to
prevent crushing and kinking.
Flexible metal vent must be fully
extended and supported when the
dryer is in its final position. Remove
excess flexible vent to avoid sagging
and kinking that may result in reduced
air flow.
An exhaust hood should cap the
exhaust vent to prevent rodents and
insects from entering the home.
Exhaust outlet hood
must be at least 12
inches from the ground
or any object that may
be in the path of the
exhaust (such as
flowers, rocks or
bushes, etc.).
If using an existing exhaust system,
clean lint from entire length of
system and make sure exhaust
hood is not plugged with lint.
Replace any plastic or metal foil vent
with rigid metal or flexible metal vent.
Use clamps to seal all joints. Do Not
use duct tape, screws or other
fastening devices that extend into the
interior of the vent to secure vent.
Service check: Back pressure in any
exhaust system used must not exceed
0.6 inches in water column measured
with an incline manometer at the point
that exhaust vent connects to dryer.
12"
minimum

6
Mobile home installation
requirements
If codes permit, this dryer is suitable
for mobile home installations.The
installation of the dryer must conform
to the
U.S. Manufactured Home Construction
and Safety Standard, Title 24 CFR,
Part 3280 (formerly the Federal
Standard for Mobile Homes
Construction and Safety, Title 24, HUD
Part 280) latest edition.
outside
wall
floor
skirting
enclosed
area
The dryer must be fastened to the
floor.
Order Mobile Home Installation Kit,
Part No. 346764, from your dealer. Kit
includes the necessary fastening
hardware and detailed installation
instructions. Metal exhaust system is
also available through your dealer.
Special provisions must be made for
the introduction of outside air into the
dryer when installed in a mobile home.
The area of any opening for the
introduction of outside air (such as a
nearby window) should be at least
twice as large as the dryer exhaust
opening.
The dryer must be exhausted
outside.
The exhaust vent must be securely
fastened to a non-combustible portion
of the mobile home structure and must
not terminate beneath the mobile
home.
better
exhaust air
flow acceptable
2-1/2"
Acceptable —
4" 4"
Preferred —
Maximum length of 4" diameter
metal vent
When you have a 4' hood
Number of
90° elbows
0
1
2
3
4
Rigid
64 feet
54 feet
44 feet
35 feet
27 feet
Flexible
(fully extended
36 feet
31 feet
27 feet
25 feet
23 feet
Maximum length of 4" diameter
metal vent
When you have a 2-1/2' hood
Number of
90° elbows
0
1
2
3
4
Rigid
58 feet
48 feet
38 feet
29 feet
21 feet
Flexible
(fully extended)
28 feet
23 feet
19 feet
17 feet
15 feet
Typical installations exhaust from the rear
of the dryer.
This dryer may be converted to exhaust
out the right or left side or through the bottom.
Typical installations
for left or right side
exhausting.
straight back
offset
Typical installations
for bottom exhausting.
Plan the exhaust vent
installation
Route the vent
The exhaust outlet is located at the
center of the rear of the dryer.
The exhaust vent can be routed up,
down, left, right or straight out the
back of the dryer. See “Recessed
area/closet installation” section, Page
4, for space requirements.
To convert the dryer, the following kits
are available from your dealer.
Exhaust Kit No. 279818 (white)
Exhaust Kit No. 279819 (almond)
Exhaust Kit No. 279925 (biscuit)
Exhaust Kit No. 279969 (silver)
Determine vent length
Select the route that will provide the
straightest and most direct path
outdoors. Plan the installation to use
the fewest number of elbows and
turns. Avoid making 90° turns.
When using elbows or making
turns, allow as much room as
possible. Bend vent gradually to avoid
kinking.

7
The maximum length of the exhaust
system depends upon:
• the type of vent (rigid or flexible
metal).
• the number of elbows used.
• side or bottom exhaust. Side or
bottom exhaust adds a 90° turn
inside the dryer. To determine
maximum exhaust length, add one
90° turn to the chart.
1. See the exhaust vent length chart
that matches your type hood for the
maximum vent lengths you can use.
Do not use vent runs longer
than specified in exhaust vent
length charts.
Exhaust systems longer than
specified will:
— Accumulate lint creating a
potential fire hazard.
— Shorten the life of the dryer.
— Reduce performance, resulting in
longer drying times and
increased energy usage.
2. Determine the number of elbows
you will need.
3. In the column listing the type of
metal vent you are using (rigid or
flexible), find the maximum length of
metal vent on the same line as the
number of elbows.
4. Determine the number of 4-inch
diameter vent clamps required.
The maximum length using a 2" x
6" rectangular vent with 2 elbows
and a 2-1/2" exhaust hood is 8 feet.
For exhaust systems not covered
by exhaust vent length charts (such
as multiple unit hookups, plenums,
and power-assist fans), see Service
Manual, Part No. 603197. (To
purchase the Service Manual, see
your Use and Care Guide for a toll-
free telephone number.)
Installation steps
If installing washer and dryer, install
dryer first.
SLIDE DRYER ONTO CARDBOARD
OR HARDBOARD BEFORE MOVING
ACROSS TO PREVENT FLOOR
DAMAGE.
A. Install vent system
Put on safety glasses and gloves.
Install exhaust hood.
Use caulking
compound to seal
exterior wall opening
around exhaust hood.
Connect exhaust vent
to hood. (Exhaust vent MUST fit inside
hood.) Secure vent to hood with 4-inch
clamp.
Run exhaust vent to dryer location.
Use the straightest path possible.
Avoid 90° turns. Use clamps to seal all
joints.Tin snips may be needed to cut
vent to required length.
Remove tape from
dryer cabinet.
Open dryer door
and remove tape
from dryer drum.
(Not all dryer
drums are taped.)
Remove drying
rack, if included.Turn dryer drum
counterclockwise to make sure all tape
was removed.Wipe drum with damp
cloth to remove any dust.
B. Prepare the dryer
diamond
marking
Excessive Weight Hazard
Use two or more people to move and
install dryer.
Failure to do so could result in back
or other injury.
WARNING
Take two cardboard corners from dryer
carton and place them on floor in back
of dryer. Firmly grasp body of dryer
and gently lay it on its back on the
cardboard corners.
Start to screw legs into holes by hand.
Use an adjustable wrench or 1” hex-
head socket wrench to finish turning
legs until you reach the ridge with the
diamond marking.
Stand dryer up on cardboard or
hardboard.

8
1. Disconnect the power supply.
2. Remove hold-down screw and
terminal block cover.
Power supply cord
terminal
block
cover
hold-down screw
external ground
conductor screw
Fire Hazard
Use a new UL approved 30
ampere power supply cord.
Use a UL approved strain relief.
Disconnect power before making
electrical connections.
Connect neutral wire (white or
center wire) to center terminal
(silver).
Ground wire (green or bare wire)
must be connected to green
ground connector.
Connect remaining 2 supply wires
to remaining 2 terminals (gold).
Securely tighten all electrical
connections.
Failure to do so can result in
death, fire, or electrical shock.
WARNING
3. Assemble 3/4" U.L.-listed strain
relief (U.L. marking on strain relief) into
the hole below terminal block opening.
Tighten strain relief screws just
enough to hold the two clamp sections
together. Install power supply
cord/cable through the strain relief.
Complete installation following
instructions for your type of
connection:
• Four-wire (recommended method)
• Three-wire (if four-wire is not
available)
Direct wire
rear
panel
strain relief
screws
strain relief
clamp sections
Fire Hazard
Use 10 gauge solid copper wire.
Use a UL approved strain relief.
Disconnect power before making
electrical connections.
Connect neutral wire (white or
center wire) to center terminal
(silver).
Ground wire (green or bare wire)
must be connected to green
ground connector.
Connect remaining 2 supply
wires to remaining 2 terminals
(gold).
Securely tighten all electrical
connections.
Failure to do so can result in
death, fire, or electrical shock.
WARNING
C. Electrical connection
GROUNDING INSTRUCTIONS:This
appliance must be grounded. In the
event of malfunction or breakdown,
grounding will reduce the risk of
electric shock by providing a path of
least resistance for electric current.
If using a power supply cord, the plug
must be plugged into an appropriate
outlet that is properly installed and
grounded in accordance with all local
codes and ordinances.
If using a direct wire connection, this
appliance must be connected to a
grounded metal, permanent wiring
system; or an equipment-ground
conductor must be run with the circuit
conductors and connected to the
equipment-ground terminal or lead on
the appliance.
WARNING - Improper connection of
the equipment-grounding conductor
can result in a risk of electric shock.
Check with a qualified electrician or
serviceman if you are in doubt as to
whether the appliance is properly
grounded. Do not modify the power
supply cord plug. If it will not fit the
outlet, have a proper outlet installed by
a qualified electrician.

9
Four-wire connection...
Four-wire power supply cord at least four feet
long must have four, No.-10 copper wires and
match a four-wire receptacle of NEMA Type
14-30R.The fourth wire (ground conductor)
must be identified with a green cover and the
neutral conductor by a white cover.
NEUTRAL NEUTRAL (white)
3/4" U.L.-listed
strain relief
ground prong ground wire
(green) ring terminals
spade
terminals with
upturned ends
4. Remove center terminal block
screw.
6. Connect ground wire (green)
of power supply cord to
external ground conductor
screw. Tighten screw.
external ground
connection
7. Connect neutral wire
(white or center) of
power supply cord
under center screw of
the terminal block.
Tighten screw.
8. Connect the other wires
to outer terminal block
screws.Tighten screws.
9.Tighten strain
relief screws.
10. Insert tab of terminal block cover into
slot of the dryer rear panel. Secure
cover with hold-down screw.
5. Remove appliance ground wire (green
with yellow stripes) from external ground
connector screw. Fasten under center,
silver-colored terminal block screw.
POWER SUPPLY CORD
14-30R Four-wire receptacle (required for mobile homes)
4. Remove center terminal block
screw.
7. Place the hooked end of the
neutral wire (white or center)
of power supply cable under
the center screw of terminal
block (hook facing right).
Squeeze hook end together.
Tighten screw.
8. Place the hooked ends of the
other power supply cable wires
under the outer terminal block
screws (hook facing right).
Squeeze hooked ends
together. Tighten screws.
6. Connect the ground wire
(bare) of the power supply
cable to the external
ground conductor screw.
Tighten screw.
10. Insert tab of terminal block cover into
slot of dryer rear panel. Secure cover
with hold-down screw.
9.Tighten strain relief screws.
5. Remove appliance ground wire
(green with yellow stripes) from
external ground connector screw.
Fasten under center, silver-colored
terminal block screw.
DIRECT WIRE
Preparing the wire:
3/4" U.L.-
listed strain
relief
to
disconnect
box NEUTRAL wire
(white or center)
10-gauge, 3-wire
with ground wire
(Romex)
5"
3-1/2"
1" of wires
stripped of
insulation
bare ground
wire
Direct wire cable must have
four feet of extra length so
dryer can be moved if needed.
Strip 5 inches of outer covering
from end of cable. Leave bare
ground wire at 5 inches. Cut
1-1/2 inches from 3 remaining
wires. Strip insulation back
1 inch.
Shape
ends of
wires
into a
hook.

10
Three-wire power supply cord at least four
feet long must have three, No.-10 copper
wires and match a three-wire receptacle of
NEMA Type 10-30R.
4. Loosen or remove center terminal
block screw.
6. Connect the other wires
to outer terminal block
screws.Tighten screws.
7.Tighten strain relief screws.
8. Insert tab of terminal block cover into
slot of dryer rear panel. Secure cover
with hold-down screw.
5. Connect the neutral wire (white
or center) of power supply cord to
the center, silver-colored terminal
screw of the terminal block.Tighten
screw.
POWER SUPPLY CORD
Three-wire connection...
NEUTRAL NEUTRAL
(white or center)
3/4" U.L.-listed
strain relief
This blade connected
to this conductor.
ring
terminals
spade
terminals with
upturned ends
Where local codes permit
connecting cabinet-ground conductor to neutral wire:
10-30R Three-wire receptacle
Where local codes permit
connecting cabinet-ground conductor to neutral wire:
4. Loosen or remove center terminal
block screw.
7.Tighten strain relief screws.
8. Insert tab of terminal block cover
into slot of dryer rear panel.
Secure cover with hold-down
screw.
6. Place the hooked ends of the
other power supply cable wires
under the outer terminal block
screws (hook facing right).
Squeeze hooked ends together.
Tighten screws.
5. Place the hooked end of the neutral
wire (white or center) of power
supply cable under the center screw
of the terminal block (hook facing
right). Squeeze hooked end
together. Tighten screw.
DIRECT WIRE
Preparing the wire:
Direct wire cable must have
four feet of extra length so
dryer can be moved if
needed.
Strip 3-1/2 inches of outer
covering from end of cable.
Strip insulation back 1 inch. If
using 3-wire cable with
ground wire, cut bare wire
even with outer covering.
Shape
ends of
wires into
a hook.
10-gauge, 3-wire or,
10-gauge, 3-wire with
ground wire (Romex)
3/4" U.L.-listed
strain relief
Three-wire with ground wire:
Bare wire cut short. Wire is
not used. Dryer is grounded
through direct wire cable.
to disconnect
box NEUTRAL wire
(white or center)
1" of wires
stripped of
insulation
3-1/2"

11
F. Check operation
4" clamp
4" clamp
Using a 4-inch clamp, connect exhaust
vent to exhaust outlet in dryer. If
connecting to existing exhaust vent,
make sure the vent is clean.
The dryer exhaust vent must fit over
the dryer exhaust outlet and inside the
exhaust hood.
Make sure exhaust vent is secured to
exhaust hood with a 4-inch clamp.
Move dryer into final position. Do not
crush or kink exhaust vent. Make sure
dryer is level.
Check that you:
✔did not skip any steps.
✔installed all parts.
✔properly installed dryer legs.
✔leveled dryer.
✔have secured all exhaust vent joints
with 4" clamps.
✔have all the tools you started with.
Plug power supply cord into grounded
outlet or connect direct wire to power
supply. Turn power supply on.
Read the Use and Care Guide to fully
understand your new dryer. Select a
full heat cycle (not the air cycle) and
start dryer. After five minutes, open
dryer door.You should feel heat inside
dryer.
If dryer does not operate properly,
check the following:
✔electrical supply is connected.
✔house fuse is intact and tight; or
circuit breaker has not tripped.
✔dryer door is closed.
✔controls are set in a running or “On”
position.
✔start button has been pushed firmly.
If dryer makes an unusual noise,
check that dryer is level.
D. Level and exhaust
dryer
Dryer must be level to reduce noise
and assure proper performance.
Slide dryer onto cardboard or
hardboard before moving across
floor to prevent floor damage.
Move dryer close to its permanent
location. Leave enough room to
connect exhaust vent. Remove
cardboard or hardboard from under
dryer
Check levelness of dryer by placing a
level on top of dryer, first side to side,
then front to back. If dryer is not level,
adjust dryer legs up or down.
If legs are not long enough to level
dryer, order Extended Dryer Feet Kit,
Part No. 279810 (sold two legs per
kit), from your dealer.
6. Connect the other
wires to outer terminal
block screws.Tighten
screws.
7.Tighten strain
relief screws.
8. Insert tab of terminal
block cover into slot of
dryer rear panel.
Secure cover with hold-
down screw.
5. Remove the appliance ground wire (green
with yellow stripes) from the external ground
connector screw. Connect appliance ground
wire and the neutral wire (white or center) of
the power supply cord/cable under the
center, silver-colored terminal block screw.
Tighten screw.
9. Connect a separate copper ground wire
from the external ground connector screw
to an adequate ground.
4. Remove center terminal
block screw.
DIRECT WIRE
OR POWER SUPPLY CORD
Where local codes Do Not permit
connecting cabinet-ground conductor to neutral wire:
Three-wire power supply cord must be
four feet long and have three, No.-10
copper wires and match a three-wire
receptacle of NEMA Type 10-30R.
Direct wire power supply cable must be
prepared as shown in “Preparing the wire”
of the three-wire connection direct-wire
steps above.
If codes permit and a separate ground
wire is used, it is recommended that a
qualified electrician determine that the
ground path is adequate.

Printed in U.S.A.
Part No. 8535840
©2002 Whirlpool Corporation Benton Harbor, Michigan 49022, U.S.A.
Moving dryer to a new
location?
Check with a licensed electrician to
confirm that supply voltage at new
home matches voltage specified on
the model/serial rating plate.
Shut off electrical supply
to dryer. Unplug power
supply cord and tape it
securely to dryer. (Or
disconnect power supply
cable from dryer.)
Tape lint collector lid to
cabinet.
Tape top to cabinet.
Tape door to
front panel.
Turn leveling legs
all the way in.
Slide dryer onto cardboard or
hardboard before moving it across
the floor to prevent damaging floor
covering.
For more information, or to
have your venting
professionally installed, call
the Consumer Assistance
Center. Check your Use and
Care Guide for a toll-free
number to call or call the
dealer from whom you
purchased this appliance.The
dealer is listed in the Yellow
Pages of your phone
directory under “Appliances
— Household — Major —
Service and Repair.”
SURE CONNECTTM Vent Kit
CRUSH
RESISTANT
Dura SafeTM
Kits Make Installation Easy
◆Provides 4 1/2"
clearance between
dryer and wall
◆Snap-Lock fittings
◆Total kit length 8 feet
◆Additional vent can
be snapped between
sections for
longer runs
Kit Contains:
2- 4' vent sections with attached close elbows
1- Wall plate for close clearance installations
2- 4" clamps
Part #4396028
Sections separate,
fittings can face
same or opposite
Extra long
band-clamp
for dryer
connection
Swivel collar
Beveled edges
allow corner
installations
Telescoping
sections
Swivel collar
wall connection
◆Provides 2 1/2" clearance
between dryer and wall
◆Great for closet installations
◆0"-18", 18"-29" or 29"-50"
periscopes include one male
snap-lock fitting, one extra
long draw-band collar and
one clamp
2
1
/2"
2
1
/
2
"
Periscopes For Offset
Outlets, Tight Installations
◆Use when vent outlets
overlap or are offset
◆Excess length can
be trimmed to fit
18"-29" and 29"-50" Periscope
0"-18" Periscope
0"-18" : Part #4396037
18"-29" : Part #4396011
29"-50" : Part #4396014
Part #4396037
18"-29" : Part #4396011 29"-50" : Part #4396014
Dura Safe and Sure Connect are Trademarks of Whirlpool, U.S.A.
.

Parte No. 8535840
Instrucciones de instalación
IMPORTANTE:
Lea y conserve estas
instrucciones
Instalador: Deje las instrucciones de
instalación con el propietario.
Propietario: Guarde las instrucciones de
instalación para referencia futura.
Para un mejor funcionamiento, instale la
secadora de acuerdo con las instrucciones
de instalación. No completar la instalación
de acuerdo con las instrucciones podría
anular la garantía.
Conserve las instrucciones de instalación para
uso del inspector de instalaciones
eléctricas local.
¿Tiene preguntas sobre su secadora?
Llame a su distribuidor o a la compañía de servicios autorizada de su
localidad.
Cuando llame, necesitará el número del modelo y el número de serie
de la secadora. Ambos números están en la placa de modelo/serie,
la cual se encuentra en la cavidad de la puerta detrás de la puerta
de la secadora y al frente de la abertura.
Anote todos los números aquí para tenerlos a mano
cuando los necesite.
Modelo No.
Serie No.
Secadora
eléctrica

2
Antes de empezar...
Herramientas que se
necesitan para la
instalación
Piezas suministradas
para la instalación
• Nivel
• Guantes
• destornillador Phillips #2
• Llave ajustable que se abra 2,5 cm
(1 pulg.) (en la ilustración) o llave
tubular hexagonal de 2,5 cm
(1 pulg.)
• Desarmador de punta plana
• Gafas protectoras
• Tijeras de hojalatero (para
instalaciones con nueva salida
de aire)
• Pistola y compuesto de masillar
(instalación de nueva ventilación)
• Pelador de alambres
(instalaciones de alambre directo)
4 patas
niveladoras
Saque el paquete de
piezas del tambor de
la secadora.Verifique
que se hayan incluido
todas las piezas.
Peligro de explosión
Mantenga los materiales y
vapores inflamables, como la
gasolina, alejados de la secadora.
Para instalar la secadora en un
garaje, coloque la secadora al
menos a 45,7 cm (18 pulg.) sobre
el piso.
No seguir estas instrucciones
puede ocasionar la muerte, una
explosión o un incendio.
ADVERTENCIA
Su seguridad y la seguridad de los
demás son muy importantes.
Hemos incluido muchos mensajes
importantes de seguridad en este
manual y en su electrodoméstico. Lea y
obedezca siempre todos los mensajes
de seguridad
Este es el símbolo de alerta de
seguridad.
Este símbolo le alerta sobre los
peligros potenciales que podrían
causarle la muerte o herirle a usted o a
otras personas.
Todos los mensajes de seguridad
seguirán al símbolo de alerta de
seguridad y a la palabra “PELIGRO” o
“ADVERTENCIA”. Estas palabras
significan:
Podría morir o sufrir graves lesiones
si no sigue las instrucciones.
Todos los mensajes de seguridad le
indicarán cuál es el peligro potencial, le
indicarán cómo reducir las posibilidades
de lesionarse y le dirán qué podría
ocurrir si no se siguen las instrucciones.
Podría morir o sufrir graves lesiones
si no sigue inmediatamente las
instrucciones.
PELIGRO
ADVERTENCIA
Para el debido funcionamiento
de la secadora:
El lugar debe proporcionar:
• Protección contra la intemperie y el
agua: no guarde ni utilice la secadora
en un lugar donde estaría expuesta al
agua y a la intemperie.
• Temperatura ambiental superior a
los 7°C (45°F): Si la temperatura es
inferior a los 7°C (45°F), los ciclos
automáticos podrían no detenerse.
• Nivel del piso: La inclinación máxima
debajo de toda la secadora no debe
ser mayor de 2,5 cm (1 pulgada). Si la
inclinación es mayor de 2,5 cm
(1 pulgada) instale el Conjunto de
Extensión de Patas para Secadora,
Parte No. 279810. Si la secadora no
está nivelada, la ropa podría no girar
debidamente y los ciclos de detección
automática podrían no funcionar
correctamente.
• Piso resistente para resistir el peso
de la secadora de 79,4 kg (175 libras).
Es su responsabilidad:
• Observar todos los códigos y
reglamentos aplicables.
• Verificar los requisitos del código:
Algunos códigos limitan o no permiten
la instalación de las secadoras de
ropa en garajes, closets (armarios),
casas móviles o rodantes o en
dormitorios. Póngase en contacto con
el inspector de edificaciones de su
localidad.
• Cumplir con las especificaciones y
dimensiones de instalación.
• Tomar en cuenta los requisitos de
espacio para artefactos que se
instalen al lado de la secadora.
• Instalar debidametne la secadora.
• Compruebe que tiene todo lo
necesario para una instalación
correcta. La instalación correcta es
su responsabilidad.
• Ponerse en contacto con un
instalador calificado para asegurarse
de que las instalaciones eléctricas y
de gas cumplan con todos los
códigos y reglamentos nacionales y
locales.

3
Piezas para adquirir:
Peligro de incendio
Utilice un conducto metálico
pesado.
No utilice conducto plástico.
No utilice un conducto de lámina
metálica.
No seguir estas instrucciones
puede ocasionar la muerte o un
incendio.
ADVERTENCIA
Sistema de salida
de aire
Se debe utilizar un conducto de salida
de aire metálico y pesado de 102 mm
(4 pulgadas) y abrazaderas. Se
recomiendan productos de salida de
aire Dura Safe™.
Puede adquirir productos de salida de
aire Dura Safe de su distribuidor o
llamando a Whirlpool Parts &
Accesories al número 1-800-442-9991,
de lunes a viernes, de 8 a.m. a 9 p.m.
(Hora Central estándar), sábado de
9 a.m. a 4:30 p.m. (HCE).Visite
nuestro sitio en Internet en la dirección
http//www.whirlpoolappliances.com
/accessories.
Para más información vea la página 11.
Campana exterior de salida
de aire
No utilice campanas exteriores de
salida de aire con cierres
magnéticos.
Las instalaciones en casas
móviles o rodantes requieren:
• Conjunto de instalación en casas
rodantes, Parte Número 346764*
• Artículos de ferretería para el
sistema de escape de metal*
Suelos con inclinaciones mayores
de 2,5 cm (1 pulg.):
Requieren Conjunto de extensión de
patas para secadoras, Parte No.
279810*.
*Disponible de compra de su distribuidor.
10,2 cm
(4 pulg.)
10,2 cm
(4 pulg.) 6,4 cm
(2-1/2 pulg.)
Preferible Aceptable
Consulte los códigos locales y vea los
requisitos eléctricos y de ventilación,
Paneles A y B, antes de comprar
pieza alguna. Determine si necesitará
comprar un juego de cordón de
suministro de energía o un cable de
suministro de energía.
Eléctrico:
Si usa un cordón de suministro de
energía:
El cordón de suministro de energía de
la secadora debe ser:
• Aprobado por U.L.
• 120/240 voltios mínimo
• 30 amperios
• Tipo SRD o SRDT
• Por lo menos de 4 pies de largo
Los alambres que conectan a la
secadora deben terminar en
terminales en anillo o en horquilla con
los extremos hacia arriba.
El contacto debe estar situado a no
más de 3 pies del centro posterior y
superior de la consola de control.
Si su contacto
tiene esta
apariencia:
Escoja este cordón
de suministro de energia
contacto para
4 alambres
(14-30R)
cordón de suministro de energía
de 4 alambres con terminales en
anillo o en horquilla y
dispositivo de protector de
cables aprobado por U.L.
cordón de suministro de energía
de 3 alambres con terminales en
anillo o en horquilla y
dispositivo de protector de
cables aprobado por U.L.
contacto para
3 alambres
(10-30R)
Si la conexión es por alambre
directo:
El cable de suministro de energía
debe corresponder al suministro (4 ó 3
alambres) y ser:
• Cable de cobre con armadura
flexible o blindaje no metálico (con
alambre de conexión a tierra). Todos
los alambres conductores de
corriente deben estar aislados.Vea
los Paneles D y E.
• ALAMBRE SÓLIDO DE COBRE DE
CALIBRE 10 (No use aluminio).)
• por lo menos de 4 pies de largo.

4
7,6 cm
(3 pulg.)
7,6 cm
(3 pulg.)
310 cm2
(48 pulg.2)***
155 cm2
(24 pulg.2)***
Vista de frente
2,5 cm
(1 pulg.)
Puerta del closet (armario)
Vista de
frente
0 cm
(0 pulg.)** 0 cm
(0 pulg.)**
38,1 cm
(15 pulg.)
** Puede necesitarse más espacio para molduras
de paredes, suelos o puertas.
*** Aberturas mínimas para el aire en la parte
superior e inferior de la puerta del closet.
**** Se requiere el espacio recomendado para un
codo de salida de aire externo.
** Puede necesitarse más espacio para molduras
de paredes, suelos o puertas.
Vista lateral
Instalación en área
empotrada
ADVERTENCIA – Para reducir el
riesgo de incendio este artefacto
DEBE VENTILARSE HACIA EL
EXTERIOR.
Instalación en
armario/área confinada
35,6 cm
(14 pulg.)
máx.
el espaciamiento
12,7 cm
(5 pulg.) es
recomendado****
• Una secadora de ropa produce
pelusa combustible y debe ventilarse
hacia el exterior.
• Las dimensiones están en
centímetros y pulgadas y son las
mínimas permisibles.
Si se instala una puerta para el
closet: se requieren aberturas
mínimas no obstruidas para asegurar
que haya flujo adecuado de aire. Son
acceptables las puertas de persiana
con aberturas para el aire
equivalentes.
Espacios de la instalación.
Utilice los espacios recomendados
para facilitar la instalación.
Recomendados/mínimos
Parte posterior –
12,7 cm/0 cm (5 pulg./0 pulg.)
Costados –
2,5 cm/0 cm (1 pulg./0 pulg.)
Parte superior –
45 cm/38,1 cm (18 pulg./15 pulg.)
Parte delantera –
2,5 cm/2,5 cm (1 pulg./1 pulg.)
Dimensiones de la secadora
35.6 cm
(14 pulg.)
La puerta de la secadora se
extiende 35,6 cm (14 pulgadas)
desde el fente de la secadora
cuando se abre totalmente.
27,9 cm
(11 pulg.)
Dimensiones mostradas con pies extendidos 25,4 mm
(1 pulgada) desde la parte inferior de la secadora.
*La mayoría de las instalaciones requerirán al menos un
espacio de 12,7 cm (5 pulg.) detrás de la secadora para el
conducto de salida de aire de la secadora.
• Se debe considerar espacio
adicional para facilitar la instalación y
el servicio (reparaciones y
mantenimiento).También se deben
considerar los requisitos de espacio
para artefactos que se instalen al
lado de la secadora.
Espacios de la instalación.
Utilice los espacios recomendados
para facilitar la instalación.
Recomendados/mínimos
Parte posterior –
12,7 cm/0 cm (5 pulg./0 pulg.)
Costados –
2,5 cm/0 cm (1 pulg./0 pulg.)
Parte superior –
45 cm/38,1 cm (18 pulg./15 pulg.)
protector de cables del cordón/cable
de suministro eléctrico
cubierta del
bloque terminal
74,3 cm (29-1/4 pulg.)
(modelos con manija de la puerta
con montaje embutido)
76,8 cm (30-1/4 pulg.)*
(modelos con manija extendida
de puerta)
109,5 cm
(43-1/8
pulg.)
97,2 cm
(38-1/4
pulg.)
68,6 cm (27 pulg.)

5
Requisitos eléctricos
Peligro de choque eléctrica
Enchufe la secadora en un
tomacorriente puesto a tierra con
3 terminales.
No quite el terminal de conexión a
tierra.
No use un adaptador.
No use un cordón de extensión.
No seguir estas instrucciones
puede ocasionar la muerte, un
incendio o un choque eléctrico.
ADVERTENCIA
Si los códigos lo permiten y se
utiliza un alambre de puesta a tierra
separado, se recomienda que un
electricista calificado determine si
la trayectoria de la puesta a tierra
es adecuada.
Importante: Observe todos los
códigos y reglamentos aplicables.
Se requiere un suministro eléctrico de
cuatro alambres o tres alambres,
monofásico, 120/240 voltios, 60 Hz,
CA solamente (o de cuatro alambres o
tres alambres, 120/208 voltios si lo
especifica la placa de modelo/serie
nominal) en un circuito independiente
de 30 amperios, con fusibles en
ambos lados de la línea. Se
recomienda usar un fusible retardador
o un cortacircuitos.
Método recomendado de
puesta a tierra
Es la responsabilidad personal y
obligación del cliente tomar contacto
con un electricista calificado para
asegurar que la instalación eléctrica
es adecuada y que cumple con el
Código Eléctrico Nacional, ANSI/NFPA
70 – última edición * y con todos los
códigos y reglamentos locales.
Se pueden obtener copias de las normas
mencionadas anteriormente de:
* National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
Suministro de gas
Peligro de incendio
Utilice un conducto metálico
pesado.
No utilice conducto plástico.
No utilice un conducto de lámina
metálica.
No seguir estas instrucciones
puede ocasionar la muerte o un
incendio.
ADVERTENCIA
•No utilice un conducto flexible no
metálico ni campanas exteriores de
salida de aire con cierres
magnéticos.
•No coloque la salida de aire de la
secadora en ningún conducto de
gas, chimenea, horno, conducto,
conducto de aire frío, pared, cielo
raso, espacio cerrado de un edificio,
un ático o sótano de pequeña altura
ni en ningún conducto de
ventilación.
•No instale un conducto flexible en
paredes, cielos rasos o pisos
encerrados.
Importante: Observe todos los
códigos y reglamentos aplicables.
Realice la salida de aire de la
secadora a exteriores. La humedad
y las pelusas a interiores pueden
hacer que:
•Las pelusas se acumulen alrededor
de la secadora donde se pueden
convertir en combustible para un
incendio.
•La humedad dañe maderas,
muebles, pintura, papel de
empapelar, alfombras, etc.
•Surjan problemas de limpieza y
problemas de salud.
Se recomiendan productos de
salida de aire Dura Safe™ los
cuales puede adquirir de su
distribuidor.
Se debe utilizar un conducto de
diámetro de 10,2 cm (4 pulg.).
Utilice conducto metálico pesado.
No utilice conductos plásticos o de
lámina metálica.
Se recomienda utilizar un conducto
metálico rígido para evitar
aplastamientos o enroscamientos.
El conducto metálico flexible debe
estar totalmente extendido y apoyado
cuando la secadora esté en su
posición definitiva. Elimine el conducto
flexible sobrante para evitar que
cuelgue o se retuerza, lo que puede
reducir el flujo del aire.
Una campana
exterior de salida de
aire debe tapar el
coducto de salida de
aire para evitar que los
roedores y los insectos
se introduzcan en la
casa.
La campana exterior de salida de
aire debe estar al menos a 30,5 cm
(12 pulg.) del suelo o cualquier objeto
que pueda interponerse en la vía de
salida de aire (como flores, rocas o
arbustos, etc.).
Si utiliza un sistema de salida de
aire existente, limpie las pelusas a
lo largo de todo el sistema de
salida de aire y asegúrese de que la
campana exterior de salida de aire
no esté taponada con pelusas.
Reemplace cualquier conducto de
ventilación de plástico o papel
metálico con un conducto rígido o
flexible de metal.
Utilice abrazaderas para conductos
para sellar todas las juntas. No utilice
para asegurar el conducto cinta
adhesiva para conductos, tornillos ni
otros dispositivos de sujeción que se
extiendan hacia el interior del
conducto.
Revisión de servicio: La presión
posterior en cualquier sistema de
salida de aire utilizado no debe ser
mayor de 1,5 cm (0,6 pulg.) de
columna de agua medida con un
manómetro inclinado en el punto
donde el coducto de salida de aire se
conecta con la secadora.
30,5 cm
(12 pulg.)
mínimo.

6
Requisitos de instalación en una
casa móvil o rodante
Si los códigos lo permiten, esta
secadora puede instalarse en una
casa móvil o rodante. La instalación
de la secadora debe cumplir con los
requisitos del U.S. Manufactured
Home Construction and Safety
Standard (Norma de construcción y
seguridad de casas manufacturadas),
Título 24 CFR, Parte 3280
(anteriormente Federal Standard for
Mobile Homes Construction and
Safety, Título 24, HUD Parte 280)
última edición.
Pared
exterior
Piso
Zocalillo
Área
encerrada
La secadora debe fijarse al piso.
Pida a su distribuidor el Conjunto para
instalación en casa móvil o rodante,
Parte No. 346764. El conjunto incluye
los elementos de fijación necesarios e
instrucciones de instalación
detalladas.También puede solicitar a
su distribuidor los elementos metálicos
del sistema de salida de aire.
Se deben hacer disposiciones
especiales para la introducción del
aire del exterior en la secadora
cuando se instala en una casa móvil o
rodante. El área de cualquier abertura
para la introducción de aire del
exterior (como una ventana cercana)
debe tener al menos el doble del
tamaño de la abertura de salida de
aire de la secadora.
La secadora tiene que tener salida de
aire al exterior.
El conducto de salida de aire debe
fijarse con seguridad a una parte no
combustible de la estructura de la
casa móvil o rodante y no debe
terminar debajo de la casa móvil o
rodante.
mejor
flujo de aire de
salida bien
Seleccione la ruta que proporcione
la vía más recta y directa hacia el
exterior. Planifique la instalación de
forma que utilice el menor número de
codos y ángulos. Evite hacer ángulos
de 90°.
Deje el máximo espacio posible
cuando utilice codos o forme
ángulos. Doble el conducto
gradualmente para no retorcerlo.
6,4 cm
(2-1/2 pulg.)
Aceptable —
10,2 cm
(4 pulg.)
10,2 cm
(4 pulg.)
Preferido —
Longitud máxima del conducto metálico
de 10,2 cm (4 pulg.) de diámetro
Cuando usted tiene una campana de salida de
aire de 10,2 cm (4 pulg.)
Número
de
codos de 90°
0
1
2
3
4
Rigido
19,5 m (64 pies)
16,5 m (54 pies)
13,4 m (44 pies)
10,7 m (35 pies)
8,2 m (27 pies)
Flexible
(completamente
extendido)
11,0 m (36 pies)
9,4 m (31 pies)
8,2 m (27 pies)
7,6 m (25 pies)
7,0 m (23 pies)
Longitud máxima del conducto metálico
de 10,2 cm (4 pulg.) de diámetro
Cuando usted tiene una campana de salida de
aire de 6,4 cm (2-1/2 pulg.)
Número
de
codos de 90°
0
1
2
3
4
Rigido
17,7 m (58 pies)
14,6 m (48 pies)
11,6 m (38 pies)
8,8 m (29 pies)
6,4 m (21 pies)
Flexible
(completamente
extendido)
8,5 m (28 pies)
7,0 m (23 pies)
5,8 m (19 pies)
5,2 m (17 pies)
4,6 m (15 pies)
En las instalaciones usuales la salida de aire
se realiza por la parte posterior de la secadora.
La secadora puede adaptarse para tener salida
de aire por el costado derecho o izquierdo o a
través de la parte inferior.
Instalaciones usuales
para salida de aire
por el costado
izquierdo o derecho.
Recto Acodado
Instalaciones usuales
para salida de aire
por la parte inferior.
Planifique la instalación
del conducto de salida
de aire
Dirija el conducto
El orificio de salida de aire se
encuentra al centro de la parte
posterior de la secadora.
El conducto de salida de aire puede
dirigirse hacia arriba, hacia abajo,
hacia la izquierda, hacia la derecha o
recto fuera de la parte posterior de la
secadora. Para requisitos de espacio,
vea la sección de “Instalación en área
empotrada/closet (armario)” en la
página 4.
Para adaptar la secadora su
distribuidor tiene disponibles los
siguientes conjuntos:
Conjunto de salida de aire
No. 279818 (blanco)
Conjunto de salida de aire
No. 279819 (almendra)
Conjunto de salida de aire
No. 279925 (biscuit)
Conjunto de salida de aire
No. 279969 (plateado)
Determine la longitud del
conducto

7
La longitud máxima del sistema de
salida de aire depende de:
• el tipo de conducto utilizado (rígido o
flexible)
• el número de codos utilizados
• si la salida de aire es por el costado o
por la parte inferior. La salida de aire
por el costado o por la parte inferior
agrega un ángulo de 90° dentro de la
secadora. Para determinar la máxima
longitud de la salida de aire, agregue
un ángulo de 90° en la tabla.
1.Vea la tabla de longitudes de
conductos de salida de aire que
corresponda a su tipo de campana
para determinar las longitudes
máximas de conductos que puede
utilizar.
No utilice conductos más largos
que los especificados en las tablas
de longitudes de conductos de
salida de aire.
Los sistemas de salida de aire más
largos de lo especificado:
- Acumulan pelusas creando peligro
potencial de incendio.
- Reducen la vida útil de la secadora.
- Reducen el funcionamiento, lo que
produce tiempos de secado más
prolongados y aumenta el consumo
de energía.
2. Determine el número de codos que
necesitará.
3. En la columna en la que se indica el
tipo de conducto de metal que está
utilizando (rígido o flexible), busque la
longitud máxima de conducto de
metal en la misma línea del número
de codos.
4. Determine el número requerido de
abrazaderas para conductos de
diámetro de 10,2 cm (4 pulg.).
La longitud máxima utilizando un
conducto rectangular de 5,1 cm x
15,2 cm (2 pulg. x 6 pulg.) con 2
codos y una campana exterior de
salida de aire de 6,4 cm (2-1/2 pulg.)
es 2,4 m
(8 pies).
Para los sistemas de salida de aire
no incluidos en las tablas de
longitudes (tales como sistemas de
conexiones para unidades múltiples,
plenos o ventiladores con aporte de
energía exterior), consulte el Manual
de Servicio, Parte No. 603197. (Para
comprar el Manual de Servicio, busque
el número para llamar gratis en su
Manual de uso y cuidado).
Etapas de la
instalación
Si está instalando una lavadora y
una secadora, instale la secadora
primero.
DESLICE LA SECADORA SOBRE UN
PEDAZO DE CARTÓN O MADERA
DURA ANTES DE MOVERLA PARA
NO DAÑAR EL PISO.
A. Instale el sistema de
ventilación (nueva
instalación)
Póngase gafas
protectoras y guantes.
Instale la campana
exterior de salida de
aire. Use masilla de
calafatear para sellar
la abertura de la pared exterior
alrededor de la campana de salida de
aire.
Conecte el conducto de salidad de
aire a la campana. (El conducto de
salida de aire DEBE calzar dentro de
la campana). Asegure el conducto a la
campana con una abrazadera de
10,2 cm (4 pulg.)
Dirija el conducto de salida de aire
hasta donde está la secadora. Utilice
la vía más recta posible. Evite formar
ángulos de 90º. Utilice abrazaderas
para sellar todas las juntas. Podría
necesitar tijeras de hojalatero para
cortar el conducto a la longitud
requerida.
Quite la cinta
adhesiva del
gabinete de la
secadora. Abra la
puerta de la
secadora y quite la
cinta adhesiva del
tambor de la
secadora. (No todos los tambores de
secadora tienen cinta adhesiva).
Saque la rejilla de secado si está
incluida. Gire el tambor de la secadora
en sentido contrario al de las
manecillas del reloj para asegurarse
de que quitó todas las cintas. Limpie
el tambor con un paño húmedo para
eliminar el polvo.
B.Prepare de la secadora
marca de
rombo
Peligro de peso excesivo
Se necesitan dos o más personas
para mover e instalar la secadora.
No seguir esta instrucción puede
ocasionar una lesión en la espalda
u otra lesión.
ADVERTENCIA
Tome dos ángulos de cartón de la
caja de la secadora y colóquelos en el
piso detrás de la secadora. Sujete con
firmeza la secadora y apoye con
cuidado su parte posterior sobre los
ángulos de cartón.
Comience a atornillar las patas en los
orificios manualmente. Utilice una llave
ajustable o una llave tubular de
2,5 cm (1 pulgada) para terminar de
darles vueltas a las patas hasta llegar
a la estría con la marca de rombo.
Coloque la secadora en posición
vertical sobre un pedazo de cartón o
madera dura.

8
1. Desconecte el suministro de
energía.
2. Retire el tornillo de retención y la
cubierta del bloque terminal.
Cordón de suministro
de energía
cubierta del
bloque
terminal
tornillo de retención
tornillo externo
del conductor de
puesta a tierra
Peligro de Incendio
Utilice un cordón de suministro
eléctrico nuevo de 30 amperios
aprobado por U.L.
Use un protector de cables con
aprobación U.L.
Desconecte el suministro eléctrico
antes de hacer las conexiones
eléctricas.
Conecte el alambre neutro (el
blanco o el del centro) con el
terminal del centro (plateado).
El alambre de tierra (el verde o el
desnudo) se debe conectar con el
conector verde de tierra.
Conecte los 2 alambres de
suministro restantes con los 2
terminales restantes (los dorados).
Apriete firmemente todas las
conexiones eléctricas.
No seguir estas instrucciones
puede causar la muerte, incendio
o choque eléctrico.
ADVERTENCIA
3. Ensamble un dispositivo de
protector de cable de 3/4” aprobado
por U.L. (aparece la marca U.L. en el
dispositivo) en el agujero debajo de la
abertura del bloque terminal. Apriete
los tornillos del dispositivo de protector
de cables sólo lo suficiente para
sostener juntas las dos secciones de
apriete. Instale el cordón/cable de
suministro de energía a través del
dispositivo de protector de cables.
Complete la instalación siguiendo
las instrucciones para su tipo de
conexión:
• Cuatro alambres (método
recomendado)
• Tres alambres (si no se dispone
de cuatro alambres)
Alambre directo
panel
posterior
tronillo externo del
conductor de cables
secciones de apriete
del dispositivo de
protector de cables
Peligro de Incendio
Utilice alambres de cobre sólido
de calibre 10.
Use un protector de cables con
aprobación U.L.
Desconecte el suministro
eléctrico antes de hacer las
conexiones eléctricas.
Conecte el alambre neutro (el
blanco o el del centro) con el
terminal del centro (plateado).
El alambre de tierra (el verde o el
desnudo) se debe conectar con el
conector verde de tierra.
Conecte los 2 alambres de
suministro restantes con los 2
terminales restantes (los
dorados).
Apriete firmemente todas las
conexiones eléctricas.
No seguir estas instrucciones
puede causar la muerte, incendio
o choque eléctrico.
ADVERTENCIA
C.Conexión eléctrica
Esta secadora está fabricada con el
conductor de puesta a tierra del
gabinete conectado al alambre
NEUTRO (central) del mazo de
alambres en el bloque terminal. Si los
códigos locales NO permiten este tipo
de conexión, use las instrucciones
para “Conexión de 4 alambres”.
INSTRUCCIONES PARA LA
CONEXIÓN A TIERRA: Este artefacto
debe ser conectado a tierra. En el
caso de funcionamiento defectuoso o
avería, la conexión a tierra reducirá el
riesgo de choque eléctrico al
proporcionar una vía de menor
resistencia para la corriente eléctrica.
Si se usa un cordón de suministro
eléctrico, el enchufe debe conectarse
en un contacto apropiado, que esté
debidamente instalado y conectado a
tierra de acuerdo con todos los
códigos y ordenanzas locales.
Si se usa una conexión directa de
alambre, este artefacto debe ser
conectado a un sistema de cableado
permanente de metal puesto a tierra,
o un conductor para la conexión a
tierra del equipo debe ser pasado con
los conductores del circuito y
conectado al terminal o cable de
puesta a tierra del equipo en el
artefacto.
ADVERTENCIA – La conexión
indebida del conductor para la
conexión a tierra del equipo puede
ocasionar un riesgo de choque
eléctrico.Verifique con un electricista o
personal de servicio técnico calificado
para asegurarse de que la conexión a
tierra del artefacto sea apropiada. No
modifique el enchufe del cordón de
suministro de energía. Si no encaja en
el contacto, contrate un electricista
calificado para que instale un contacto
apropiado.
Table of contents
Languages:
Other Whirlpool Other manuals

Whirlpool
Whirlpool 3397617 User manual

Whirlpool
Whirlpool AGB 591/WP Parts list manual

Whirlpool
Whirlpool 8053365 User manual

Whirlpool
Whirlpool 76612-00/4315709 User manual

Whirlpool
Whirlpool 3402328 User manual

Whirlpool
Whirlpool 98015194 User manual

Whirlpool
Whirlpool 8535845 User manual

Whirlpool
Whirlpool 3LG5701XP User manual

Whirlpool
Whirlpool STANDARD CLEANING GAS RANGE User manual

Whirlpool
Whirlpool 8316557 User manual