WIDE Automation WALR 24-2A User manual

Operating instructions for safety module mod. WALR 24-2A
WIDE Automation S.r.l. via Malpasso, 1340 47842 S. Giovanni in Marignano [RN] tel. +39 0541 827200 fax +39 0541 825021 www.wideautomation.it
Subject to technical changes without notice, no responsibility will be assumed for every detail. ©WIDE AUTOMATION S.r.l. - WARL24-2A Operating Instruction (EN) rev.0, 05-2017 – Pag. 1/2
Description
The WALR 24-2A control unit has been designed for the control of pressure
sensitive mats and safety edges in accordance with EN ISO 13856-1: 2013,
EN ISO 13856-2: 2013, EN 60204-1: 2006 + A1: 2009, EN ISO 13849-1:
2015.
The operation of this module is based on the use of guided contact safety
relays.
Safety precautions
Pressure sensitive safety mats and edges perform a personal protective
function. Incorrect installations or manipulations can cause serious personal
injury.
Pressure sensitive safety mats and safety edges must not be bypassed
(shorting the contacts), moved, removed or otherwise rendered ineffective.
The machine manufacturer or installer is responsible for correct and safe
operation.
The auxiliary exchange output 15-16-17 provides a signal on the status of
the device, therefore it must not be used in any way as a safety output.
The WALR 24-2A is not suitable for operation in the presence of ionizing
and non-ionizing radiation (X-rays, microwaves, lasers, ultraviolet rays) (EN
60204-1: 2006, §4.4.7).
Operation
The WALR 24-2A safety control unit is able to check the status of pressure
sensitive safety mats and edges: the output is activated by pressing and
releasing the START (reset) button only if the two inputs are closed and if
none operator is in the area covered by the carpet (edge). When the safety
device is pressed, the control unit opens the safe outputs 20-21 and 23-24.
The Reset, manual and monitored, is possible only once the device is no
longer pressed as required by EN ISO 13856-1: 2013 (Appendix A) and EN
ISO 13856-2: 2013 (Appendix A).
It is possible to configure the control unit so that the reset takes place
automatically upon release of the mat (edge) by connecting terminals 3-5
together.
The opening of even a single input connection determines a safety situation,
placing the safe outputs in the open state and preventing their re-closing
even after the contact has been re-closed and the START button (reset) is
pressed.
The system composed of WALR24-2A + carpet or pressure sensitive edge
reaches the safety category 3 according to EN ISO 13849-1: 2015 only if
(see connection drawing):
- two relays are used to interrupt the load, each of which connected to an
output of the control unit.
- the relay contacts controlled by the control unit are inserted in the
feedback ring.
Safety is guaranteed by the use of guided contacts, redundancy and the
interconnection scheme of the contacts.
It is the responsibility of the user to choose suitable components for
safety applications, such as guided contact relays.
Installation
The installation must be carried out only by authorized personnel.
The WALR 24-2A control unit must be installed in a suitable area of use
(electrical panel, junction box, at least IP54). The control unit is installed by
attaching it to a standard 35mm DIN omega rail.
Electric connections
Electrical connections must be made only by personnel authorized in
accordance with EN 60204-1: 2006.
All electrical inputs must be isolated from the main power supply or through
a transformer with separate windings in accordance with EN IEC 61558-2-6
with limited output voltage in the event of a defect, or by an equivalent
removable mechanism.
The power supply must be permanently connected using a cable with a
maximum length of 10m; safety mat must be connected to the unit with
cables with a maximum length of 30m.
The relay outputs have a maximum current of 6A; the power supply
connected to these outputs must be protected against overcurrent by
devices suitable for the loads to be protected.
All output contacts must have an adequate protection circuit for inductive
and capacitive loads.
If a standard power supply is used, all inductive and capacitive loads (e.g.
relay contacts) connected to the power supply must be connected to an
appropriate interference suppressor.
Maintenance and checks
The correct operation of the WALR 24-2A control unit must be periodically
checked by the operator and/or by the control circuit of the machine in
which it is used (at the beginning of each shift) by checking the following:
- correct switching
- secure attachment of components
- correct fixing of the connections.
The device monitoring function is performed at each intervention of the
device itself.
In case of failure or wear, the damaged system must be replaced.
Warranty coverage disappears in the following circumstances:
- if the instructions are not followed
- non-compliance with safety regulations
- installation and electrical connection not carried out by authorized
personnel
- failure to carry out functional checks.
Setup
If the control unit does not seem to work when the supply voltage is applied
(the green POWER LED does not light up), the unit must be returned sealed
to the manufacturer. Check if the safety outputs switch (see LED table) by
activating the inputs and pressing the START (reset) button.
Connections
MANUAL
RESET
AUTOMATIC
RESET
Operating instructions for safety module mod. WALR 24-2A
WIDE Automation S.r.l. via Malpasso, 1340 47842 S. Giovanni in Marignano [RN] tel. +39 0541 827200 fax +39 0541 825021 www.wideautomation.it
Subject to technical changes without notice, no responsibility will be assumed for every detail. ©WIDE AUTOMATION S.r.l. - WARL24-2A Operating Instruction (EN) rev.0, 05-2017 – Pag. 2/2
LED Indication
Dimensions (mm)
FUNCTION
LED
Colour
Status
Operating voltage
Power
Red
On
Output 20-21 and 23-24: OPEN
Output 15-16: CLOSED
Output 16-17: OPEN
ALARM
Red
On
OK
Green
Off
Output 20-21 and 23-24:
CLOSED
Output 15-16: OPEN
Output 16-17: CLOSED
ALARM
Red
Off
OK
Green
On
Technical data
Parameter
Value
Container Material
PA
Dimensions
91 x 61.7 x 71.8 mm
Weight
170 g
Operating environmental conditions
Temperature: -5 … +55 °C
Relative Humidity: 4% … 100%
Pressure: 86 … 106 kPa
Environmental storage conditions
Temperature: -25 … +70 °C
Relative Humidity: 5% … 95%
Pressure: 86 … 106 kPa
Degree of protection (IEC 60529)
IP20
Degree of contamination
2
Assembly
35mm DIN standard Rail
Connection Type
Screw terminals
Supply Voltage
24 Vdc (-15% / +10%)
Internal Fuse on the power supply
630mA fast fuse
Current consumption
@24Vdc: 60mA min, 115mA max
Safety Output Switching Voltage
250Vac, 30Vdc
Switching current AC-1 / Electrical Life
6A (AC/DC) (safety outputs) / 105cycles
Minimum Switching current @10V
10mA
Safety Output Switching Power
1500VA, 180W
External fuse at the Output
4A gG (according IEC EN 60269-1)
Safety Output Terminals
20 – 21, 23 – 24
Auxiliary Output Terminals
16 (Common) - 15 (NC) - 17 (NO)
Usage Category / Electrical Life
(SAFETY Outputs)
AC-15: 2A / 240Vac (inductive load, cosφ= 0.3) / 105cycles
DC-13: 1A / 24Vdc / 105cycles
Auxiliary NC Output parameters
250Vac, 10A, 2500VA
Useful Lifetime
10 years
OFF state response time
20mS
Safety Category and PL
(EN ISO 13849-1:2015)
CAT. 3
PL-d
PL-e
PL-e
nop (number of operation / year)
(load: AC-15: 1,4 A / 250 Vac)
66000
31900
19000
MTTFd (years)
30
62
100
PFHd
2.65x10-7
8.84x10-8
4.29x10-8
TM
20 years (MTTFd = 100 years)
Vibration Resistance
EN ISO 13856-1:2013, EN ISO 13856-2:2013
Mechanical Life (# of cycles)
107
EMC Compliance
EN 61326-3-1:2011,
EN 55011:2011
In accordance with
EN 60204-1:2006+A1:2009, EN ISO 13849-1:2015,
EN ISO 13856-1:2013, EN ISO 13856-2:2013
Approvals
TÜV IT 0948 17 MAC 0110 B

Other WIDE Automation Control Unit manuals

WIDE Automation WALR 24-2A User manual

WIDE Automation

WIDE Automation WALR 24-2A User manual

WIDE Automation NC96 MAT User manual

WIDE Automation

WIDE Automation NC96 MAT User manual

Popular Control Unit manuals by other brands

Brähler Systems DIGIMIC DCen mini MkII quick guide

Brähler Systems

Brähler Systems DIGIMIC DCen mini MkII quick guide

VELAN EE-1000 Maintenance manual

VELAN

VELAN EE-1000 Maintenance manual

hager h3 h400 User instructions

hager

hager h3 h400 User instructions

Jolly Mec QUA/ARIA/6 user manual

Jolly Mec

Jolly Mec QUA/ARIA/6 user manual

CALEFFI 574 series manual

CALEFFI

CALEFFI 574 series manual

Bosch Rexroth WE6/BVP1 Series operating instructions

Bosch

Bosch Rexroth WE6/BVP1 Series operating instructions

sauter EY-RU Series quick start guide

sauter

sauter EY-RU Series quick start guide

Yoshitake AF-7 instruction manual

Yoshitake

Yoshitake AF-7 instruction manual

Satel INT-VMG manual

Satel

Satel INT-VMG manual

Allen-Bradley ControlLogix SynchLink 1756-SYNCH user manual

Allen-Bradley

Allen-Bradley ControlLogix SynchLink 1756-SYNCH user manual

Mantis ULV BioMant-ONE operating instructions

Mantis ULV

Mantis ULV BioMant-ONE operating instructions

Lawler 61 Series Installation & maintenance manual

Lawler

Lawler 61 Series Installation & maintenance manual

Texas Instruments DAC8742H user guide

Texas Instruments

Texas Instruments DAC8742H user guide

Smarteck Electronics QT-06 user manual

Smarteck Electronics

Smarteck Electronics QT-06 user manual

DR. Z Amplification Brake Lite manual

DR. Z Amplification

DR. Z Amplification Brake Lite manual

ST ACEPACK DMT-32 Mounting instruction

ST

ST ACEPACK DMT-32 Mounting instruction

Fenwal Controls FC1 Operation & instruction manual

Fenwal Controls

Fenwal Controls FC1 Operation & instruction manual

tau DC19 installation guide

tau

tau DC19 installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.