Montageanleitung (Original)/ Installation instruction (translation from original)
wienetIPSWITCHUMS 8-W-M12 83.040.1600.0
Unmanaged Industrial Ethernet Switch mit/with 8 M12-Ethernet-Ports
Wieland Electric GmbH
Brennerstraße 10
– 14
96052 Bamberg
Phone
+49 9519324-0
Fax
+49 9519324-198
info@wieland
-electric.com
www.wieland-electric.com
Doc. # BA001253 – 06/2021 (Rev. B) wienet IP SWITCH UMS 8-W-M1 2 1 DE / EN
HINWEIS
Personal, welches dieses Gerät installiert, programmiert, in Betrieb nimmt oder wartet,
muss diese Anleitung gelesen und verstanden haben.
WARNUNG
•Das Personal muss gründlich mit allen Warnungen, Hinweisen und Maßnahmen gemäß
dieser Montageanleitung vertraut sein.
•Ggf. erforderliche Schutzmaßnahmen und Schutzeinrichtungen müssen den gültigen
Vorschriften entsprechen.
•Beschädigte Produkte dürfen weder installiert noch in Betrieb genommen werden.
•Das Gerät darf nicht geöffnet werden.
•Führen Sie keine Fremdobjekte in das Gerät ein!
•Halten Sie das Gerät von Wasser und Feuer fern!
•Das Gerät kann im Betrieb sehr heiß werden. Berühren Sie das Gerät während des Be-
triebs nicht.
Weitere Beschreibungen finden Sie im Internet unter www.wieland-electric.com
1Funktionsbeschreibung
Das Gerät ist ein Unmanaged Indust ri al Ethernet Switch mit acht M12-Ethernet-Ports für in-
dustrielle Anwendungen.
HINWEIS
Verwenden Sie das Gerät nur gemäß seiner Bestimmung. Beachten Sie dazu insbesondere
die Angaben im Abschnitt "Technischen Daten".
2Funktionselemente und Anzeigen
Pinbelegungen und Verbindungen
M12, D-kodiert
10 / 100 BASE-T (X)
Pin
1
2
3
4
5
Signal
Tx+
Rx+
Tx-
Rx-
N/A
Versorgungs-/ Signalanschlüsse
M12, A-kodiert
Pin
1
2
3
4
F.G.
V2+
V2-
V1+
V1-
Signal
12–48 V DC
0 V
12–48 V DC
0 V
⏚
LEDs
Name
LED
Status
Beschreibung
Power 1/2 grün

Stromversorgung P1,P2 nicht angeschlossen

Stromversorgung P1,P2 istaktiv
Lnk/Act
grün

Nicht an Netzwerk angeschlossen
•
Datenübertragung

Netzwerk angeschlossen
gelb

Nicht an Netzwerk angeschlossen oder an Netzwerk mit
10 Mbps angeschlossen
•
Datenübertragung

Netzwerk angeschlossen (100/1000 Mbps)
= aus; = an;•= blinkt
NOTE
Personnel which installs, programs, operates or maintains this device must have read and
understood these instructions.
WARNING
•The personnel must be thoroughly familiar with all warnings, notes and procedures de-
scribed in these installation instructions.
•
Where necessary, safety precautions and safety devices must comply with the applicable
regulations.
•Damaged products mustneither be installed nor put into operation.
•The unit must not be opened.
•Do not insert any objects into theunit!
•Keep the unit away from fire and water!
•The switch can become very hot during operation. Do not touch the surface during oper-
ation.
Additional information canbe found at www.wie land-electric.com
1Function description
The device is an unmanaged industrial Ethernet switch with eight M12-Ethernet-Ports for
industrial applications.
NOTE
Use the device only as intended. Especially observe the specifications in the section "Tech-
nical data".
2Functional elements and indicators
Pin assignments and connections
M12, D-coded
10 / 100 BASE-T (X)
Pin
1
2
3
4
5
Signal
Tx+
Rx+
Tx-
Rx-
N/A
Power connectors
M12, A-coded
Pin
1
2
3
4
F.G.
V2+
V2-
V1+
V1-
Signal
12–48 V DC
0 V
12–48 V DC
0 V
⏚
LEDs
Name
LED
Status
Description
Power 1/2 green

Power input P1, P2 is inactive

Power input P1, P2 is active
Lnk/Act
green

Not connected to network
•
Data is transmitting

Connected to network
yellow

Connected to networkat 10 Mbps or not linked
•
Data is transmitting

Connected to network(at 100/1000Mbps)
= off; = on;•= flashes
1
2
3
Montageanleitung (Original)/ Installation instruction (translation from original)
wienetIPSWITCHUMS 8-W-M12 83.040.1600.0
Unmanaged Industrial Ethernet Switch mit/with 8 M12-Ethernet-Ports
Wieland Electric GmbH
Brennerstraße 10
– 14
96052 Bamberg
Phone
+49 9519324-0
Fax
+49 9519324-198
info@wieland
-electric.com
www.wieland-electric.com
Doc. # BA001253 – 06/2021 (Rev. B) wienet IP SWITCH UMS 8-W-M1 2 2 DE / EN
3Montage
Anbringen auf Trägerschiene (Bild 3)
1. Bohren Sie 4 Löcher in die Wand passend zu den Schraublöchern am Switch.
Lochgröße: 5,0 mm
2. Schrauben Sie die4 Schrauben durch die Schraublöcher am Switch an die Wand.
Anschluss an Spannungsversorgung
•Geeignete Spannungsversorgungan wienet Switch über M12-Power anschließen.
•Anschluss zweier separater Stromquellen für eine redundante Spannungsversorgung
(Power 1, Power 2) möglich.
Anschluss von Netzwerkgeräten
Schließen Sie Ihre Netzwerkgeräte über M12-Ethernet-Kabel mit M12-Steckverbindern an
den w ienet Switch an.
4Demontage
WARNUNG
Schalten Sie die Spannungsversorgung aus und trennen Sie das Gerät vom Netz.
Lösen Sie die Schrauben vorsichtig und nehmen Sie das Gerät von der Wand.
5Technische Daten
WARNUNG
•Verwenden Sie nur Kabel mit mindestens AWG 20 am Stromanschluss, die auf eine Be-
triebstemperatur bis 85 °C ausgelegt sind.
•Das Gerät muss in einem Gehäuse vom Typ 1 installiert werden.
Kommunikation
Anschlüsse
8× M12 D-kodiert (10/100Base-T (X))
Übertragungsgeschwindigkeit
bis zu 100 Mbps,Auto-Negotiation
Übertragungsstandard
IEEE 802.3, IEEE 802.3u, IEEE802.3x
Spannungsversorgung
Redundante Einspeisung
ja (P1, P2)
Eingangsspannung
12 – 48 V DC
Eingangsstrom
max. 1,5 A
Leistungsaufnahme
max. 2,5 W
Betriebsspannung
9,6 – 57,6 V DC
Verpolschutz
ja
Überlaststrom
ja, mit zurücksetzbarer Sicherung
Allgemeine Daten
Betriebsumgebungstemperatur
-40 … +75 °C
Lagertemperatur
-40 …+85 °C
Relative Luftfeuchte
5 …95% RH, keine Kondensation
Montage
Wandmontage
Schutzart
IP67
MTBF
1.690.953h
Gewicht
700 g
Gehäusematerial
Metall
Anschlusstechnik
Anschlusstechnik Power
4-pol. M12 A-kodierter Anschluss
Anschlusstechnik Ethernet
5-pol. M12 D-kodierter Anschluss
Anschlussvermögen
M12-Anschlussstecker
Modulerdung
durch ⏚Erdungsschraube (Achtung: niederimpedant
durchführen)
Schock und Vibration
Schock
Vibration
Freier Fall
IEC60068-2-27 , EN 61373
IEC60068
-2-6: 5g @ 10–150 Hz
IEC60068-2-32
Normen und Zulassungen
EMV
EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5 ,
EN 61000-4-6, EN 61000-4-8, EN 61131-2
Sicherheit
UL61010
FCC
FCC, Class A
Zulassung
CE
3Installation
Mounting on support rail (see fig. 3)
1. Prepare the 4 screw holes on the wall according to the switch.
Screw hole size: 5.0 mm
2. Screw in the 4 screws through the screw holes on the switch to the wall.
Connecting to power
•Prepare a suitable power source and connect to the wi enet switch via M12 Power.
•You can connect two independent DC input sources for power auto-backup if necessary
(Power 1, Power 2).
Connecting to network device by Ethernet
Connect your device by M12 Ethernet cable with M12 connectors to the wienet s wit ch.
4Removal
WARNING
Switch mains power off and disconnect the device from the supply network.
Carefully loosen the screws and take the device off the wall.
5Technical data
WARNING
•It is recommended to use at least 20 AWG cables. The cables need to be resistant to at
least 85 °C on the power connector.
•The device needs to be installed inside a type 1 housing.
Communication
Connectors
8× M12 D-code (10/100Base-T (X))
Transfer rate
up to 100 Mbps, auto-negotiation
Standard
IEEE 802.3, IEEE 802.3u, IEEE802.3x
Power supply
Redundant power supply
yes (P1, P2)
Input voltage
12 – 48 V DC
Input current
max. 1.5 A
Power consumption
max. 2.5 W
Operating voltage
9.6 – 57.6 V DC
Reverse polarity protection
yes
Overload current
yes, with resettable fuse
General data
Ambient operating temperature
-40 … +75 °C
Storage temperature
-40 …+85 °C
Ambient relativehumidity
5 …95% RH, non-condensing
Mounting
wall mounting
Degree of protection
IP67
MTBF
1,690,953 h
Weight
700 g
Housing material
metal
Connectors
Wiring Power
4 pin M12 A-coded connector
Wiring Ethernet
5 pin M12 D-coded connector
Rated conductor size
male M12 connector
Module earth
by ⏚screw (Caution: must be with low impedance)
Shock and vibration
Shock
Vibration
Free fall
IEC60068-2-27 , EN 61373
IEC60068-2-6: 5g @ 10–150 Hz
IEC60068-2-32
Norms and approvals
EMC
EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5,
EN 61000-4-6, EN 61000-4-8, EN 61131-2
Safety
UL61010
FCC
FCC, Class A
Approval
CE
WARNUNG
WARNING
AVERTISSEMENT
•Dieses Produkt ist für die Versorgung durch eine UL-zertifi-
zierteStromversorgung oder eine Gleichstromquelle vor-
gesehen, die für den Einsatz bei mindestens 75 °C geeignet
ist, Der Ausgang muss SELV oder ES1 entsprechen und für
12–48 V DC(min. 1,5 A) ausgelegt sein. Wenn Sie weitere
Unterstützung benötigen, wenden Sie sich bitte an Wie-
land. Siehe www.wieland-electric.com.
•Stellen Sie sicher, dass die Betriebsspannung an der Span-
nungsversorgung korrekt ist, bevor Sie das Gerät anschlie-
ßen. Die Spannungsversorgung sollte einen geerdeten An-
schluss haben.
•Öffnen Sie niemals das Gerät. Aus Sicherheitsgründen
sollte das Gerät nur von einer qualifizierten Fachkraft ge-
öffnet werden
•Dieses Gerät ist nicht für die Verwendung an Orten geeig-
net, an denen sich Kinder aufhalten können.
•This product is intended to be supplied by a UL certified
power supply or DC source suitable for use at minimum
Tma 75 °Cwhose output meets SELV or ES1 and is rated
12–48 V DC, 1.5 A minimum. If you need further assistance,
please contact Wieland E lectric
for further information.See
www.wieland-electric.com.
•Ensure that the voltage of the power source is correct be-
fore connecting the equipment to a power outlet.
The power outlet socket should have grounded connec-
tion.
•Never open the equipment. For safety reasons, the equip-
ment should be opened only by qualified skilled person.
•This equipment is not suitable for use in locations where
children are likely to be present.
•Ce produit est destiné à être alimenté par une alimentation
certifiée UL ou une source de courant continu adaptée à
une utilisation à au moinsTma 75 °C dont la sortie satisfait
les conditions SELV ou ES1 et est évaluée à 12–48VCC, 1,5 A
minimum. Si vous avez besoin d'une aide supplémentaire,
veuillez contacter Wieland Electric pour plus d'informa-
tions. Voir www.wieland-electric.com.
•Assurez-vous que la tension de la source d'alimentation est
correcte avant de connecter l'équipement à une prise de
courant. La prise de courant doit avoir une prise de terre.
•N'ouvrez jamais l'équipement. Pour des raisons de sécu-
rité, l'équipement ne doit être ouvert que par une per-
sonne qualifiée.
•Cet équipement ne convient pas à une utilisation dans des
lieux pouvant accueillir des enfants

This manual suits for next models

1

Other Wieland Switch manuals

Wieland wienet FS8 Series User manual

Wieland

Wieland wienet FS8 Series User manual

Wieland UMS 6-C-1G-4PoE-1SFP-W User manual

Wieland

Wieland UMS 6-C-1G-4PoE-1SFP-W User manual

Wieland wienet UMS 8-C User manual

Wieland

Wieland wienet UMS 8-C User manual

Wieland SNO 4063K-A User manual

Wieland

Wieland SNO 4063K-A User manual

Wieland SNA 4043KE User manual

Wieland

Wieland SNA 4043KE User manual

Wieland SNO 4003K User manual

Wieland

Wieland SNO 4003K User manual

Wieland SIN 1 Series User manual

Wieland

Wieland SIN 1 Series User manual

Wieland wienet UMS 5-C-4G-1SFP-W User manual

Wieland

Wieland wienet UMS 5-C-4G-1SFP-W User manual

Wieland samos User manual

Wieland

Wieland samos User manual

Wieland SIN 1 Series User manual

Wieland

Wieland SIN 1 Series User manual

Popular Switch manuals by other brands

H3C S9500 Series Operation manual

H3C

H3C S9500 Series Operation manual

GarrettCom DS8016 Installation and user guide

GarrettCom

GarrettCom DS8016 Installation and user guide

Philips SWS4683S/10 datasheet

Philips

Philips SWS4683S/10 datasheet

D-Link xStack DGS-3420-28SC Quick installation guide

D-Link

D-Link xStack DGS-3420-28SC Quick installation guide

WTI NPS-4HS15 Series Hardware guide

WTI

WTI NPS-4HS15 Series Hardware guide

ATEN Altusen KH1516a user manual

ATEN

ATEN Altusen KH1516a user manual

Linksys EZXS55W v4.2 user guide

Linksys

Linksys EZXS55W v4.2 user guide

pathway 7150 manual

pathway

pathway 7150 manual

Comelit IPSWN08N01A user manual

Comelit

Comelit IPSWN08N01A user manual

Tellabs 6325 Hardware installation manual

Tellabs

Tellabs 6325 Hardware installation manual

SEKURYX CK4-HP104C quick start guide

SEKURYX

SEKURYX CK4-HP104C quick start guide

Hama USB Hub user manual

Hama

Hama USB Hub user manual

HotBrick Firewall VPN SoHo 401 VPN Quick install guide

HotBrick

HotBrick Firewall VPN SoHo 401 VPN Quick install guide

H3C LSQM1TGS24QSA0 user manual

H3C

H3C LSQM1TGS24QSA0 user manual

H3C S10500X Series Configuration guide

H3C

H3C S10500X Series Configuration guide

NETGEAR GSM7312 - ProSafe Layer 3 Managed Gigabit... Hardware installation guide

NETGEAR

NETGEAR GSM7312 - ProSafe Layer 3 Managed Gigabit... Hardware installation guide

Lenovo RackSwitch G8264 Command reference

Lenovo

Lenovo RackSwitch G8264 Command reference

BABBITT LS7000 owner's manual

BABBITT

BABBITT LS7000 owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.