WilTec 338A User manual

Artikel 75998 - Stand: 29.10.2008
Installation Guide
Motorcycle Alarm System
Type 338A/998A
Important notice:
The reprint or reproduction, even of excerpts, and any commercial use, even
in part of this instructions manual require the written permission of Wiltec
Wildanger Technik GmbH.
Technical changes reserved!
Due to further developments, illustrations, functioning steps and technical
data can differ insignificantly.
Updating the documentation
If you have suggestions for improvement or have found any irregularities
please contact us.
EC-Declaration of Conformity
(According to the guidelines 1999/5/EG (R&TTE)
Producer / person responsible WilTec Wildanger Technik GmbH
Koenigsbenden 12
52249 Eschweiler, Germany
Ensures that the product: 75998, Inwells Motorcycle Alarm
System
Type: 338A
Designated use: Securing two-wheeled vehicles
when properly used, the above mentioned model fulfils the basic requirements and
the guidelines complying with the
1999/5/EC R&TTE
When evaluating the product according to the EU demands, the following standards
were applied:
R&TTE EN300 220-3 V1.3.1:2000
EN301 489-3 V1.4.1:2002
If the product is changed this declaration loses its validity.
Eschweiler, 14. December 2006
__________________________
Bernd Wildanger
Manager
The product can be introduced in all EU-states without restrictions (as well as in other states that follow the
EU-Directive 1999/5/EG).

Artikel 75998 - Stand: 29.10.2008
General Information
Requirements:
1. Voltage: DC 12Volt +/- 3Volt
2. The motorcycle has to run idle in order to start the engine.
3. The control unit has to be positioned in a damp-proof place of the
motorcycle because the device is not water-proof.
4. The control unit must not be thrown or exposed to moisture.
Functional description:
•Audio-Optic Alarm: Press and the signal horn rings out once,
the blinker flashes, after 3 sec the alarm is activated.
•Disarm: Press and the horn rings twice the blinker flashes twice
indicating that the system is disarmed.
•Shaking- Alarm: if the alarm system is activated and the motorcycle
starts shaking, the blinker flashes and the horn warns.
If the shaking happens again in 5 sec, the immobilizer is activated and
the engine cannot be started, the blinker flashes and the horn rings.
•Motorcycle searching: If the system is activated, press
and an alarm is triggered, so that you can find out the location of your
vehicle.
•Silent Alarm: By pressing the button you activate the silent alarm.
In case the motorcycle is shaken a short acoustical signal is given
followed by an optical warning issued by the blinker.
•
Immobilizer: It is only for motorcycles equipped with a negative switching
emergency switch. Because this function is optional, one can let it disconnected
by motorcycles with positive switching emergency switch or by rollers. For the
immobilizer the grey and the pink cables are assigned.
•Remote start: Press , the engine starts automatically. In case the engine
does not run, just push again the button. The starting motor is activated aslong
you press the button of the remote control. (It does not function if the motorcycle
battery is too weak or empty.)
•Switching off the engine: Just press for turning off and the engine shuts
down.
•Anti Hijacking: In case your motorcycle is stolen while the machine is running,
just press the engine stops immediately, the horn rings permanently and the
blinker flashes. (This function is only ensured, if the motorcycle is started via
remote control or if the immobilizer (grey / pink cables) is connected.
•Adjusting the sensitivity: In case the sensitivity is set too low, sever the green
cable. (see the illustrations)
•Setting sensitivity via remote control: press and or and
buttons (depending on the model year) of the remote control simultaneously,
the blinker flashes quickly three times, indicating that sensitivity can be adjusted
via remote control. Briefly press only once and the shock sensitivity
changes. The degree of sensitivity is indicated via blinker. There arefour
sensitivity levels that can be set. After setting, press and you quit the set
level. (1x blinking insensitive, 4x blinking very sensitive).

Artikel 75998 - Stand: 29.10.2008
Connection Diagram Motorcycle Type 338A/998A
Antenne
AnBa
t
t
e
r
i
e
P
l
u
s
a
n
s
c
h
l
i
e
s
s
e
n
R
o
t
Weiss
N
o
t
-
A
u
s
S
c
h
a
l
t
e
r
(
z
u
m
S
c
h
a
l
t
e
r
)
A
n
B
a
t
t
e
r
i
e
M
i
n
u
s
/
M
a
s
s
e
O
r
a
n
g
e
B
l
i
n
k
e
r
S
i
g
n
a
l
/
H
o
r
n
Grau
Pink
Schwarz
Rot
Gelb
Blau
Kabel zum
A
n
l
a
s
s
e
r
r
e
l
a
i
s
(
P
o
s
i
t
i
v
)
Gelb
(vom Schalter)
Symbole Funktion
Alarmanlage schärfen
Mute Alarm (lautloser Alarm)
Motorstart
Alarmanlage deaktivieren
Symbole und Funktionen

Artikel 75998 - Stand: 29.10.2008
Fault tracing Motorcycle Type 338A/998A
Installations problems and their causes:
Problem
C
ause
/
E
limination
The alarm system shows no function The supply voltage is not connected / please check the contact of the red
and of both black cables
Are all the cables connected? Plus and minus alone are not enough to test
the system!
The alarm system cannot be activated,
or the alarm is triggered immediately when enabled The alarm system detects a false signal / the orange cable is incorrectly
connected and has still +12V when armed/activated
By engine remote start the motorcycle won’t start
(starting motor rotates itself) The cables (orange) an ACC (ignition switch positive) is not properly
connected / check the cabling.
Beim Motorfernstart startet das Motorrad nicht
(Starter dreht nicht) The starter relay is not positively switched but negatively / Connect
another relay to the earth side of the starter relay which is activated by
remote start via blue cable (of the alarm system).
The alarm is triggered but the siren does not go off The connector to the alarm siren has no contact / plug in the connector
When the remote control is activated, the blinkers do not
flash The battery of the motorcycle could be discharged please change the
battery to ensure the alarm function.
If you have checked the whole cable layout and read these instructions and still cannot put the alarm system into operation, note down
which cable you have connected and send us an Email, as well as a description of the malfunction.
Send your Email-support to: [email protected], without a first contact via Email no (!) telephone support is provided!
By telephone and written enquires please always specify your customer and order number. In case you did not purchase the alarm
system from WilTec Wildanger Technik GmbH, please contact your seller.

Artikel 75998 - Stand: 29.10.2008
Symbols and functions
Symbols and functions
Activate the alarm system
Deactivate the alarm system
Mute alarm
Motor starter
Red – connect it to the plus of the battery
Grey – Emergency off switch/ Emergency Power Off→to the switch
Pink – Emergency off switch/ Emergency Power Off ←from the switch
Black – to the minus of the battery / earth
Orange – ignition switch positive ACC
Yellow –
Yellow – blinker
Blue – cable to the starter relay (positive)
White
Red
Signal /horn
This manual suits for next models