INSPECTION 
Carefully unpack and inspect your ex
- 
tractor for shipping damage. Each 
unit 
is operated and thoroughly inspected 
before shipping, and any damage is the 
responsibility of the carrier, who should 
be notifiedimmediately. 
ELECTRICAL 
This extractor operates on a standard 
15 amp 
115
volt AC circuit.‘ Voltages 
below 
105 
volts or above 
125 
volts could 
cause serious damage to motors. Wiring 
diagram is mounted inside handle con
- 
trol panelof machine. 
‘230 
volt 50Hz model available. 
WARNING: 
To avoid electric shock: 
1.
useinaoors only. 
2. 
To reduce risk of fire, do not use 
volatile.substances. 
3. 
Use only cleaners intended for floor 
and carpet application. 
GROUNDING INSTRUCTIONS 
To protect the operator from electric 
shock, this machine must be grounded 
while in use. The machine is equipped 
with an approved three
-
conductor power 
cord and three
-
prong grounding type 
plug to fit the proper grounding type re
- 
ceptacle. The vacuum power cord has a 
plug as shown in Fig. 
A. 
If 
a receptacle 
connected 
to 
the electrical ground as 
shown in Fig. 
A 
is not available use an 
adapter as shown in Fig. 
C.
The adapter 
must be connected to an electrical 
ground in the electrical outlet, using 
metal screw shown in Fig. B.
GROUMOING 
” 
PIN 
IA) 
POAPTER 
GROUNOED 
OUTLET 
BOX 
EXTENSION 
CORDS 
If an extension cord is used, the wire 
size must be at least one size larger 
than the power cord on the machine: 
The ADM is equipped with a 50 ft. 14/3 
power cord. 
FILLING THE ADM 
1.
Removeclear dome from upper tank. 
Do
not remove the 
two 
vacuum hoses. 
NOTE: 
Dome can be set securely be
- 
tween handle uprights when handle 
is inOperating position. 
2.
Lift upper recovery tank from machine 
and set aside. 
3.
Use a clean bucket to fill solution 
tank with hot water. Add a non- 
foaming concentrate for use in hot 
water extractors at the proportions 
noted on the container. 
CAUT/ON: 
To avoid possible dls- 
tortlon of polyethylene solution/ 
recovery tanks, 
00 
NOT USE WATER
2 
TEMPERATURE THAT EXCEEDS 
150’F (65’C) 
NOTE: 
Makesure dome is seated cor
- 
rectly to ensure proper vacuum seal. 
CHEMICALS 
The internal parts of the pump used in 
the extractor is suitable for use with 
most carpet cleaning chemicals. But it 
is susceptible 
to 
chemical attach from 
some cleaning substances, such as 
hydrocarbon solvents and chlorinated 
bleaches. These noncompatible materi
- 
als are not 
of 
the type normally used 
for carpet cleaning. 
SUITABLE NONCOMPATIBLE 
CHEMICALS CHEMICALS 
Alkalis 
Clorox
II 
Bleach’ 
Defoaming 
Agents 
Detergents
Hydroxides
Oxygen
Bleaches 
Soaps 
Ski-Put
Fabric 
Softener
Vinegar
White 
Monday 
Bleach’ 
‘Aegisterea 
Trademark 
Aldehydes
Aromatic Hydrocarbons
Butyls 
Carbon 
Tetrachloride
Clorox‘
Chlorinated Bleaches
a 
Chlorinated Hydrocarbons
Lysol’ 
Methyls
(MEK) 
Perchlorethylene (perc) 
Phenols
Trichlorethylene
OPERATING THE 
ADM 
NOTE: 
Vacuum the carpet and make 
sure it is cleared of surface debris be
- 
fore cleaning with the ADM. 
NOTE: 
Attach strain relieflcord retainer 
to power cord. 
1.
Make loop in power 
cord approximately 
12” 
from twist lock 
receptacle end. 
2 
Slue cord loop through 
slot 
in 
retainerand over 
retainer arm. Pull slack 
cord back through slot 
to secure. Attach re
- 
tainer to handle. 
3.
Release cam
-
locking device located 
on lower right of handle and lower 
handle 
to 
comfortable operating po
- 
sition. Re
-
set cam
-
lock on handle. 
NOTE: 
ADM cleans by pulling back
- 
wards over the carpet. 
Dlaaram 
1 
a.
Brush adjustment lever 
b.
Solution nipple 
c.
Solutionvalve 
d. Handle locking lever 
e.
Solution tank drain hose 
4.
Adjust brush to proper cleaning po
- 
sition by using lever located at lower 
back of the motor housing. Start at 
No.
1 
“new brush” (black) position. 
If more carpet pile agitation is desired, 
lower brush setting one position at a 
time. (See Diagram 
2)
Diagram 
2 
[n”‘i
Black 
‘TI 
Red 
5.
Check 
to 
be sure that spray manifold 
valve is set on “Carpet Spray” posi
- 
tion (See Diagram 
3) 
and that brush 
motor circuit breaker button is 
in 
(see 
Diagram 
4). 
Diagram 
3 
pi
ACCESSITOOL 
CONTINUOU 
BRUSHSWITCH PUMP SWITC 
CIRCUIT BREAKER INTERMITTENT 
P 
Diagram 
4 
SWITCH 
PANEL 
6.
Tilt machine bacK on rear wheels 
until brush is off the floor. Turn on 
vacuum and brush motors. 
NOTES: 
1.
Starting the machine with dry brush 
resting on the carpet may trip brush 
circuit breaker. 
2.
The vacuum motor is also protect
- 
ed by a circuit breaker.The breaker 
will only trip under conditions of 
abuse 
- 
an over
-
full recovery tank. 
7. Lower machine to floor. Dispense 
solution by using either the “contin
- 
uous flow” swltch for large, open 
areas or the “intermittent solution” 
button for cleaning in smaller, more 
confined areas. Walking backwards, 
move the extractor over the area to 
be cleaned. The extractor’s brush 
assistance should allow the machine 
to be moved quickly and easily over 
the carpet. Remember to turn SOlUtlOn
off about six inches before the end 
of each cleaning pass. 
8.
As you work, check to see if there is 
a foam build up in the recovery bucket. 
If 
there is, turn the machine 
off 
and 
add the recommended amount of de- 
foaming compound to the recovery 
tank. Never put defoamer 
In 
solution 
tank! 
WARNING: 
An overflow of foam 
into the vacuum intake can damage 
the vac motor. Always be aware of 
the waste water level in the recovery 
tank. When it is about three
-
quarters 
full, turn off the machine, removethe 
dome and lift off the recovery tank to 
empty. The tank has a convenient 
carrying handle and a built
-
In hand- 
grip on the underside. 
9.
When the extractor runs out of Clean.
lng solution (this can be easily de
- 
tected by streaking and incomplete 
cleaning of the carpet, or by looking 
at spray manifold from side of ma
- 
chine) turn off the machine, remove 
the dome and recovery bucket, and 
re
-
fill the clean solution tank. 
Re
- 
place the recovery tank and dome. 
Turn the extractor back on and con
- 
tinue cleaning. 
10.
Ventilate area after carpet has been 
cleaned. Keep children and pets away 
and do not walk on carpet until it is 
thoroughly dry.