Wise F510 User manual

Tel +82-2-300-2300
Fax +82-2-300-2400
webmaster@wisecontrol.com
C-QIM-2731-F02_EN_Rev.1
Integral flow orifice plate
assembly
F510

1
Tel +82-2-300-2300
Fax +82-2-300-2400
webmaster@wisecontrol.com
C-QIM-2731-F02_EN_Rev.1
CONTENT
1. General .................................................................................................................................................................... 2
1.1 Introduction .......................................................................................................................................................... 2
1.2 Information regarding the user manual ................................................................................................. 2
1.3 Warranty................................................................................................................................................................. 2
2. Warnings ................................................................................................................................................................ 3
3. Pre-installationinspections ............................................................................................................................ 4
4. Installingandoperatingtheproduct........................................................................................................ 4
4-1. General ................................................................................................................................................................. 4
4-2. Direction of installation................................................................................................................................. 5
4-4. Option ................................................................................................................................................................... 8
4-5. Inspection ............................................................................................................................................................ 8
5. Maintenance......................................................................................................................................................... 9
6. Transport,packagingandstorageoftheproduct ............................................................................. 9

2
Tel +82-2-300-2300
Fax +82-2-300-2400
webmaster@wisecontrol.com
C-QIM-2731-F02_EN_Rev.1
1. General
1.1Introduction
TheIntegralorificeplatemanufacturedbyWISEControlInc.isinstalledinthemiddleofapipewhere
afluidflows.Theareaoftheorificeplateissmallerthanthepipe,andthepressuredifferential
betweenthefrontandrearoftheorificeplateisusedtomeasureflowrate.
Integralorificeplatesaremanufacturedaccordingtocustomerspecifications.
1.2Informationregardingtheusermanual
1) Theusermanualcontainsimportantinformationforproperhandlingofthedevice.Pleasereadthis
usermanualcarefullybeforeinstallationandcommissioning.
2) Pleaseadheretothesafetyandhandlingguidelinesprovidedinthisusermanual.Compliancemust
bemaintainedwiththeapplicableaccidentpreventionandsafetyregulations,aswellasnational
installationstandardsandacceptedcodesofconduct.
3) Thisusermanualispartoftheproduct,andmustbemadeavailableforviewingbyworkersnearby
theinstallationlocationatalltimes.
4) WISEControlInc.reservestherighttomodifytechnicalelementsoftheproductwithoutprior
notice
1.3Warranty
TheIntegralorificeplatemanufacturedbyWISEControlInc.hasbeenmanufacturedaccordingto
individualcustomerrequirements.Theproductmustbestoredunderappropriateconditions,andthe
requirementsinvariousdocumentation,testreportsandusermanualsmustbeobservedtomaintain
optimalusecondition.

3
Tel +82-2-300-2300
Fax +82-2-300-2400
webmaster@wisecontrol.com
C-QIM-2731-F02_EN_Rev.1
2. Warnings
Handlingmanualforsafeuse
Toensuresafeandproperuseoftheproduct,pleasethoroughlyreadthishandlingmanualbefore
use.Improperhandlingmaycauseequipmentmalfunction,aswellasaccidentssuchasinjury.
Warnings
1) Forsafety,installationmustbecarriedoutbyworkerswithprofessionalexpertiseininstruments
andelectricalworks.
2) Installtheproductintheuseenvironmentprescribedinthespecifications.
3) Usewithinthegiventemperaturerange.
4) Protectfromexcessiveload,vibrationorimpact.
5) Donotmoveorlifttheorificeplateusingthenameplate.
(Thenameplateisintendedforidentificationonly,andtransportorliftingoftheproductusingthe
nameplatemayresultindamage.)
!

4
Tel +82-2-300-2300
Fax +82-2-300-2400
webmaster@wisecontrol.com
C-QIM-2731-F02_EN_Rev.1
3. Pre-installationinspections
1) Checkthetagnumberoftheproductandconfirmthattheproductisintendedfortheinstallation
location.
2) Checkforanyweldingbeadsorprojections.Priortoinstallation,checkthesurfaceoftheorifice
plateforanydentingorscratching.
3) Theinsideofthepipemustbesmoothandclean,andfreeofanyforeignmatter.
4. Installingandoperatingtheproduct
4-1.General
DifferentialpressuregeneratedbytheIntegralorificeplateisdischargedthroughconnectionstothe
upstreamanddownstreampressuretaps.Theconnectionsaredesignatedasupstreamand
downstreamtapsbasedonthedirectionofflowofthefluid.
Thedirectionofflowofthefluidisindicatedonthefrontofthenameplateoftheorificeplate.
(See<Figure1>)
< Figure 1 >

5
Tel +82-2-300-2300
Fax +82-2-300-2400
webmaster@wisecontrol.com
C-QIM-2731-F02_EN_Rev.1
4-2.Directionofinstallation
Theintegralorificeplatemustbeinstalledaccordingtothedirectionofflow.Theinstallationdirections
inthefigurebelowarerecommendeddependingonthetypeoffluid.
1) Installationongas&vaporlines
● Installationinhorizontalpipes ● Installationinverticalpipes

6
Tel +82-2-300-2300
Fax +82-2-300-2400
webmaster@wisecontrol.com
C-QIM-2731-F02_EN_Rev.1
2) Installationonliquidline
● Horizontalpipeandbottomtap ● Horizontalpipeandsidetap
● Installationinverticalpipes

7
Tel +82-2-300-2300
Fax +82-2-300-2400
webmaster@wisecontrol.com
C-QIM-2731-F02_EN_Rev.1
3) Installationonsteamline
● Horizontalpipeandbottomtap ● Horizontalpipeandsidetap

8
Tel +82-2-300-2300
Fax +82-2-300-2400
webmaster@wisecontrol.com
C-QIM-2731-F02_EN_Rev.1
4-4.Option
1) Transmitter
- Model:SMT2001
- Refertothehomepageforthe
SMT2001manual.
(www.wisecontrol.com)
2) Extendedlegset
- Appliedatoveroper.temp.120℃.
- Refertotheright<Figure2>.
4-5.Inspection
1) Checktheinstallationlocationoftheintegralorificeplate,andthedirectionofflow.
2) Checkthattheinnersurfaceofthepipeissmoothandcleaned.
3) Confirmthattheconnectionflangeformsaconcentriccirclewiththeinsideofthepipeline,and
thatthepressuretappointshavebeenalignedinaccordancewiththedrawings.
4) Allweldbeadsmustbeuniform.Ensurethatprojectionsintotheinsideofthepipearekepttoa
minimum.
5) Ensurethatthetapsandrelatedpipesarecleanpriortouse.Inspectthetapholesandrelated
pipesforweldsandotherobstructions.Removeobstructionsasnecessary.
<Figure 2>

9
Tel +82-2-300-2300
Fax +82-2-300-2400
webmaster@wisecontrol.com
C-QIM-2731-F02_EN_Rev.1
5. Maintenance
1) Dependingonprocessconditions,regularlyinspectforsignsofobstruction,erosionorcorrosion.
2) Priortobeginningwork,confirmthatpipeshavebeenpurgedofpressureanddrained.
3) Observepowerplantsafetyregulationsatalltimes.
4) Aftercomplyingwithsitesafetyregulationsandremovingthefluidflowingthroughthepiping,
loosenallbolts/nutsbeforeworkandtheorificeplatecanbecheckedorreplaced.
5) Whenreassemblingtheproductafterdisassembly,newgasketsmustbeused.
Whenreassembling,payattentiontotheupstreamanddownstreamdirections.
6. Transport,packagingandstorageoftheproduct
1) Theproductmustnotbeexposedtohumidity,dustorothercontaminants.
2) Theproductmustnotbesubjectedtoimpactduringstorage.
3) Whenreturningtheproductforrepairs,safelypackagetheproductinitsoriginalpackaging,and
returntherelateddocumentationaswell.
4) The product should be protected from exposure to humidity, dust and other contaminants
duringtransport.
5) Theproductshouldbepackagedtoprotectagainstimpactduringtransport.
6) Anydamagetotheproductduringtransportshouldberecordedinthedocumentation.Claims
forcompensationfordelaysininstallationmaybemadeagainstthetransportingcompany.

10
Tel +82-2-300-2300
Fax +82-2-300-2400
webmaster@wisecontrol.com
C-QIM-2731-F02_EN_Rev.1
Thecontentofthisdocumenthasbeenpainstakinglyproduced,butpleaseunderstandthattheremaybetyposor
correctionstobemade.Thespecificationsandappearanceofthisproductaresubjecttochangewithoutnoticefor
qualityimprovement,andWISEreservestherighttochangethis.Theillustrationsusedinthisinstructionmanualare
forillustrativepurposesonlyandmaydifferfromtheactualproduct
YonginFactory
2022Deogyeong-daero,Giheung-
gu,Yongin-si,Gyeonggi-do(Sanggal-
dong)
www.wisecontrol.com
A/SrelatedInquiries
2022Deogyeong-daero,Giheung-
gu,Yongin-si,Gyeonggi-do(Sanggal-
dong)
webmaster@wisecontrol.com
Homepage:Service
center>Technology/QuoteInquiry
WISECONTROLINC.
#181,Gasandigital1-ro,Geumcheon-
gu,Seoul,(Gasan-dong,GasanW
CENTER)F19
T.02-300-2300
F.02-300-2400

Tel +82-2-300-2300
Fax +82-2-300-2400
webmaster@wisecontrol.com
C-QIM-2731-F02_KR_Rev.1
Integral flow orifice plate
assembly
F510

1
Tel +82-2-300-2300
Fax +82-2-300-2400
webmaster@wisecontrol.com
C-QIM-2731-F02_KR_Rev.1
목차
1. 일반사항 ................................................................................................................................................................... 2
1.1 소개 .......................................................................................................................................................................... 2
1.2 사용설명서 관련 정보 ....................................................................................................................................... 2
1.3 보증 .......................................................................................................................................................................... 2
2. 경고 ............................................................................................................................................................................ 3
3. 제품 설치 전 점검 사항 .................................................................................................................................... 4
4. 제품 설치 및 조작 방법 .................................................................................................................................... 4
4-1. 기본 사항 ............................................................................................................................................................. 4
4-2. 설치 방향 ............................................................................................................................................................. 5
4-4. 옵션 사항 ............................................................................................................................................................. 8
4-5. 점검 ........................................................................................................................................................................ 8
5. 유지보수 ................................................................................................................................................................... 9
6. 제품의 운송 및 포장, 보관 ............................................................................................................................... 9

2
Tel +82-2-300-2300
Fax +82-2-300-2400
webmaster@wisecontrol.com
C-QIM-2731-F02_KR_Rev.1
1. 일반사항
1.1 소개
㈜와이즈에서 제작하는 일체형 오리피스 플레이트(Integralorificeplate)는 유체가 흐르는 관로 중간에 플
레이트를 설치하여, 유체의 배관 구경보다 면적을 좁게 하여 발생되는 전,후 압력 차를 통해 유량을 측정하
는 유량계 입니다. 일체형 오리피스 플레이트(Integralorificeplate)는 고객의 사양에 따라 제조되는 제품
입니다.
1.2 사용설명서 관련 정보
1) 본 사용설명서에는 장치의 올바른 취급에 관한 중요한 정보가 들어 있으므로 설치 및 시험 운전을 하기
전 이 사용 설명서를 주의 깊게 읽어주십시오.
2) 본 사용설명서에 명시된 안전 및 취급 지침을 따라주십시오. 적용 가능한 사고예방 규정과 안전 규정 뿐
만 아니라 국가 설치 표준 및 인정된 행동 규범을 준수해야 합니다.
3) 본 사용설명서는 제품 일부로써 제품 설치 장소 근처에 항상 작업자가 확인할 수 있도록 비치 되어야 합
니다.
4) ㈜와이즈는 제품의 기술적인 요소를 예고 없이 변경할 권리가 있습니다
1.3 보증
㈜와이즈에서 제작한 ‘일체형 오리피스 플레이트(Integralorificeplate)’는 각 고객의 사양에 맞추어 제작한
제품입니다.
본 제품은 적절한 장소에 보관이 이루어져야 하며, 사용하는 기간 동안 최적의 상태를 유지하려면 각종
문서와 성적서, 취급 설명서 등의 필요 조건을 반드시 준수해 주십시오.

3
Tel +82-2-300-2300
Fax +82-2-300-2400
webmaster@wisecontrol.com
C-QIM-2731-F02_KR_Rev.1
2. 경고
안전한 사용을 위한 취급 설명서
이 제품을 바르고 안전하게 사용하기 위하여 사용 전에 이 취급설명서를 잘 읽어주시기 바랍니다.
취급 시의 오류는 기기 고장의 원인이 되며, 상해나 사고 등의 재해가 발생할 수 있습니다.
경 고
1) 안전을 위해 설치는 계장, 전기공사등의 전문기술을 보유한 작업자가 실시하여야 합니다.
2) 본 제품은 사양서에 명시되어 있는 사용환경에 설치하십시오.
3) 사용 가능한 온도 범위 내에서 사용하십시오.
4) 무리한 하중, 진동, 충격을 가하지 마십시오.
5) 오리피스 플레이트의 명판을 이용하여 제품을 운반하거나 인양하지 마십시오.
(명판은 식별을 위한 부분이며, 명판을 이용한 제품 운반 및 인양 시, 파손이 일어날 수 있습니다.)
!

4
Tel +82-2-300-2300
Fax +82-2-300-2400
webmaster@wisecontrol.com
C-QIM-2731-F02_KR_Rev.1
3. 제품 설치 전 점검 사항
1) 제품의 태그 번호 및 설치될 위치의 제품인지 확인하십시오.
2) 용접 윤곽선, 돌출 부분 등이 없어야 하며, 설치 전에 오리피스 플레이트 표면에 찌그러짐이나 긁힘이 있
는지 확인해 주십시오.
3) 배관 내부는 부드럽고 깨끗해야 하며, 이물질이 없는지 확인해 주십시오.
4. 제품 설치 및 조작 방법
4-1. 기본 사항
일체형 오리피스 플레이트(Integralorificeplate)에 의해 생성된 차압은 전,후단 압력 탭의 연결로 배출 됩니
다. 연결 부분은 유체 흐름 방향 기준으로 전단 탭, 후단 탭으로 구분됩니다.
유체 흐름 방향은 플레이트의 명판 전단부에 표시 됩니다.(<Figure1> 참조)
< Figure 1 >

5
Tel +82-2-300-2300
Fax +82-2-300-2400
webmaster@wisecontrol.com
C-QIM-2731-F02_KR_Rev.1
4-2. 설치 방향
일체형 오리피스 플레이트(Integralorificeplate)은 유체의 흐름 방향에 따라 설치 되어야 하며, 설치 방향은
유체의 종류에 따라 아래 그림과 같이 설치하는 것을 권장 합니다.
1) GAS&VaporLine에 설치하는 경우
● 수평 배관 적용 시 ● 수직 배관 적용 시

6
Tel +82-2-300-2300
Fax +82-2-300-2400
webmaster@wisecontrol.com
C-QIM-2731-F02_KR_Rev.1
2) LiquidLine에 설치하는 경우
● 수평 배관 적용 시 (하단 Tap 적용 시) ● 수평 배관 적용 시 (측면 Tap 적용 시)
● 수직 배관 적용 시

7
Tel +82-2-300-2300
Fax +82-2-300-2400
webmaster@wisecontrol.com
C-QIM-2731-F02_KR_Rev.1
3) SteamLine에 설치하는 경우
● 수평 배관 적용 시 (하단 Tap 적용 시) ● 수평 배관 적용 시 (측면 Tap 적용 시)

8
Tel +82-2-300-2300
Fax +82-2-300-2400
webmaster@wisecontrol.com
C-QIM-2731-F02_KR_Rev.1
4-4. 옵션 사항
1) Transmitter
- Model:SMT2001
- SMT2001 메뉴얼은 홈페이지
참조 바랍니다.
(www.wisecontrol.com)
2) Extendedlegset
- Oper.Temp.120℃ 이상인 경우
적용합니다.
- 우측 <Figure2> 그림 참조 바랍니다.
4-5. 점검
1) 일체형 오리피스 플레이트의 설치할 위치를 확인한 후 유체 방향을 확인하십시오.
2) 파이프 내부 표면이 매끄럽고 깨끗한지 확인하십시오.
3) 연결 플랜지가 파이프라인의 내부와 동심원을 이루며 압력 탭 지점이 도면에 따라 정렬되었는지 확인
합니다.
4) 모든 용접 윤곽은 균일 해야 합니다. 파이프 내부의 돌출 부분이 최소로 유지되도록 주의하십시오.
5) 탭 및 관련 배관은 사용 전 깨끗한지 확인해야 합니다. 탭 구멍 및 관련 파이프에 용접 지점 또는 기
타 막힘이 없는지 점검하십시오. 필요한 경우 막힘을 제거할 수 있습니다.
모든 세척 사양(예: 산소/제약 서비스)을 준수하십시오.
<Figure 2>
Table of contents
Languages:
Other Wise Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

Parker
Parker ChemTec II Installation, operating, & maintenance instructions

Generac Power Systems
Generac Power Systems MINI DUST-FIGHTER owner's manual

Endress+Hauser
Endress+Hauser LT5 operating instructions

Emerson
Emerson RXi HMI user manual

SENTRON
SENTRON SI400 7400-0 manual

PinSightz
PinSightz CM4949PRO operating instructions