Wise PT850 Series User manual

Ultra High Purity
Pressure Transmitter
Manual
PT850
PT851
PT852
PT853
(Internal Pressure Type)
(Intrinsic SafetyType)
(Non-Flammable Type)
(Standard Type)
English

For safe use, Please read this manual before operating the product.
Misuse of the product could cause the harm to users, and also could create the malfunciton of the product.
02
Safety Manual Guide
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
Do not apply over pressure or excessive voltage.
Please avoid excessive weight, Vibration, and impact to the transmitter.
It could cause the rupture, and the leaked fluid or material could be harmful to the environment.
Allowed Operating Temperature (Tamb = -20 ~ 80 °C)
Excessive temperature could cause the malfuction of the transmitter and measuring error.
If explosive gas is present, use correspoing enviromental entity approved products,
and do not disassemble or assemble the transmitter in such area.
Before disconnecting the transmitter, user must make sure that the valve is closed so the measuring fluid would not leak.
The leakage could cause the suffocation and explosion.
Installation of transmitter must be performed according to this manual.
Do not temper transmitter to add new function to it.
For repairing Purpose, please consult the manufacturer.
Warnings
English

03
01.
02.
03.
04.
05.
06.
07.
08.
09.
10.
11.
12.
13.
Outline
Characteristics
Specification and Standard
Process Connection Type and Size
Each Part Name and Working Principle
Ground Connection
Name Plate
Connection and Disconnection
Transfer, Storage, and Cautions for Opening the Package
Connection Area
Maintenance and Operating Cautions
Safety Measures
Limited Warranty and Limitation of Liability
04
04
05
06
10
11
12
13
15
15
16
16
17
Contents
English

PT85x Series is a High Precision Transmitter to measure pressure in a various industry area. Especially,
it is developed to serve the needs for high purity area such as Semiconductor and Pharmaceutical industry.
04
1. Outline
1)
2)
3)
4)
5)
6)
Reponsive time within 20ms of Output Current
Improved performance, Precision, and Reliability
0.1 % Error rate during 1 Year
Slim Design
Accrracy within ± 0.25 %
4-20 mA Output Current
2. Characteristics
English

1)
2)
3)
4)
5)
6)
7)
8)
9)
10)
11)
12)
Power
Working Temperature
Temp. Compensation
Allowed Humidity
Allowed Altitude
Power Consumption
Process Material
Measuring Range
Accuracy
Material
Explosion Proof Rate
Method to attach Label
:
:
:
:
:
:
:
:
:
:
:
:
12 ~ 24 V DC
-20 ~ 80 °C (PT851, PT852, PT853)
-20 ~ 70 °C (PT850)
-20 ~ 60 °C
Below 85 %
Below 1000 m
3.75 mA ~ 21.5 mA
Fluid, Gas
-15 ~ 30 psi (Min), -15 ~ 3000 psi (Max)
Span ± 0.25 %
Process mdeia - Gases and liquid compatible with stainless steel 316L, 630
Housing - Stainless steel 316L
Ex d IIC T6 / IP65 (PT850)
Ex ia IIC T4/T5/T6 IP65 (PT851)
Ex nA IIC T4/T5/T6 IP65 (PT852)
On the side of Cylinder
05
3. Specification and Standard
English

06
4. Process Connection Type and Size
1-1) PT850
Straight male (Swivel face seal) Type
Straight female (Swivel face seal) TypeTube Welding Type
Male Thread Type
* Note : Specifications subject to change without notice.
English

1-2) PT850
07
* Note : Specifications subject to change without notice.
Flow Through Female (Swivel face seal) type
Flow Through Male (Fixed face seal) Type
1.125" Modular Surface Mount Type
English

08
4. Process Connection Type and Size
2-1) PT851, PT852, PT853
* Note : Specifications subject to change without notice.
Tube Welding Type
Male Thread Type Straight male (Swivel face seal) Type
Straight female (Swivel face seal) Type
English

2-2) PT851, PT852, PT853
09
* Note : Specifications subject to change without notice.1.125" Modular Surface Mount Type
Flow Through Female (Swivel face seal) type Flow Through Male (Fixed face seal) Type
English

1) Each Part Name
2) Working Principle
①
②
Pressure applied to the pressure input section, and the pressure value will convert into an electronical singal.
Measured pressure will be transferred after converting into 4 ~ 20 mA electrical current.
10
5. Each Part Name and Working Principle
2 Wire Connection Socket
Body
2 Wire Connection Socket
Pressure Input Section
Pressure Input Section
Body
English

1)
2)
3)
4)
Shield Wire and outer surface is connected together, and Cable shield wire should be connected to Ground Terminal.
Ground Cable wire is AWG24, and in case of using Extension wire, the standard should be higher than Ground Wire standard.
In case of working on the terminal, to prevent the unwinding, use washer and to prevent the corrosion, use plated terminal and lug.
Ground point should be connected to rebar, floor, or Bus Bar.
(Ground Point should be considered with a local Industrial regulation, and Electric standards)
6. Ground Connection
11
English

12
7. Name Plate
PT850
PT851
PT852
PT853
English

1) Connection Diagram (PT851, Max Cable Length : 48 M)
1-1) Intrinsic Safety Coefficient : Ex ia IIC T4 (Ui = 28 V, li = 93 mA, Pi = 650 mW, Ci = 0.0414 µF, Li = 48.07 µH)
1-2) Recommended ZENER BARRIER Parameter : Uo = 28 V, Io = 93 mA, Po = 650 mW, Co = 0.083 µF, Lo = 4.2 mH
8. Connection and Disconnection
13
English
/T5/T6

2) Diagram (PT850, PT852, PT853)
14
Transmitter
Power Supply Indicator PLC or Data Gathering System
3) Disconnection (PT850) 4) Disconnection (PT851, PT852, PT853)
14
23
+ (Red)
CABLE
- (Black)
FG (Shield Jaket)
+ (Red)
CABLE
- (Black)
FG (White)
(+)(-)
English
RED BLACK

1)
2)
3)
4)
Transfer Caution
•Avoid dropping of the PT, it will cause a performance degradation.
Storage Caution
•Avoid humidity, vibration, and dust.
•Avoid falling, and prevent the damage from the overload.
Opening Caution
•Be careful when opening the pakage.
•To prevent falling, open the pakage in a wide area.
Opening Steps
•Removal of Box → Removal of Vinyl Cover → Removal of internal Vinyl inside Cleanroom
9. Transfer, Storage, and Cautions for Opening the Package
1)
2)
3)
4)
5)
6)
7)
For safe use, avoid humid, vibration, and corrosive gas in the installation area.
Avoid area where it can excess the temperature listed on the manual.
For choosing installation site, Please consider the possibility of Lightning and steam damage.
Avoid a direct sunlight.
In case of installing on the pipe, use a proper spanner.
Do not remove the protection cap from the Trasnmitter before installation.
If the Transmtter is detached, please place the protection cap back on the Transmitter.
10. Connection Area
15
English

1)
2)
3)
4)
5)
6)
7)
Working pressure should not be over 100 % of its Maximum pressure.
Do not apply overpressure.
Avoid sudden pressure or sudden decompression.
Scheduled examimation should be 1 or 2 times in every 6 months.
If measured pressure error is suspected, then detached the Transmitter for the examination.
If Transmitter is worn out, it is exposed to any other harsh environment, then the measuring error could be found,
it is recommended to replace the Transmitter.
Consult licensed Technician for repair to avoid fire, electric shock, or injury.
If requies Zero Adjustment, Use our Zero Trim Calibrator.
11. Maintenance and Operating Cautions
1)
2)
3)
4)
5)
6)
7)
This product should not be treated as unclassfied industrial waste.
To prevent the malfunction of the product, please use it within the defined usage.
Read all instructions carefully.
Between terminals or terminal surface area, do not apply more than normal voltage.
If the transmitter is damaged, disconnect the power and pressure from the transmitter to avoid any explosion.
If malfuction occurs, do not use the transmitter.
Use allowed normal electric cable only.
12. Safety Measures
16
English

1)
2)
3)
Warranty Period is 1 year from the date purchased, the damage from Misuse and any other abnormal use caused issues will not be covered.
Warranty Period will not be extended by other resellers.
To receive Warranty Service, send the transmitter to WISE with the product issue stated.
13. Limited Warranty and Limitation of Liability
17
English


Zero Trim Calibrator
Manual
PT85x Series
(Zero Trim Calibrator)
English

02
03
04
05
06
08
01.
02.
03.
04.
05.
General Information
Components and Connecting Method
Each Part Name and Function
How to Use
Operating Cautions
Contents
English
This manual suits for next models
4
Table of contents
Other Wise Transmitter manuals
Popular Transmitter manuals by other brands

Camille Bauer
Camille Bauer KINAX WT720 operating instructions

Eurotron
Eurotron IRtec Rayomatic 14 MK2 instruction manual

KWorld
KWorld SA240 user manual

Crown
Crown FM30 user manual

AEI Security & Communications
AEI Security & Communications DG258 igiSender HQ2 user manual

Alligator
Alligator KC-9512 instruction manual