Onceyouhaveprogrammedintheadministratorsnumbersitisnowpossibletoalsonowprogramamatrixof
whoshouldreceivetheSMStextalertsandconfirmationmessages.
Thesystemispre‐setasfactorydefaulttosend#TEL1SMStextalertsandmessagesoncethatnumberhasbeen
enteredandconfirmedinthe#TEL1andthe#CTR=1alarmfunctionturnedOn.
TheMatrixisprogrammedusingthe#RERNcommandwhichcantogglethelistofnumbersOnorOffbasedon
usingthedigit1asOnand0asOffasfollows.
Thefactorydefaulthassetupthe#RERNas#RERN=10000000whichindicatesthefirstadministratornumberin
thelistwillreceivetheSMStextalertsandmessagesandtheremainingsevenadministratorswillnotreceive
anySMStextalertsormessages.
TochangetheMatrixofpersonswhowillreceivetheSMSalertsormessagesyouwouldsimplyusethisformat
andtoassumewewantonlyadministrator14and6toreceivetheSMSalertsandmessageswewouldsendthe
followingSMSmessagetotheunit.
#PWD654321#RERN=10010100andyoushouldreceivethefollowingSMSmessagefromtheunitifsent
correctly.RERN=10010100andonlytheadministrators14and6willreceivetheSMStextalertsandmessages.
TochangethematrixyouwouldjustoverwritetheexistingmatrixbysendingantherSMSmessagetotheunit
andifyouwanttosendmorethanonemessagetooneofftheAdministratorsyouwouldsimplyenterthat
administratorinthe#TELlistthenumberoftimesyouwantthemtoreceivetheSMStextalertsandmessages.
SettinguptheAlarmInputMessagewhenactivated
ThesystemhasanalarmInputthatwilltriggeracustomizedSMStextalerttotheadministratorsasrecordedin
the#TELlistandactivatedintheMatrixtoreceivetheSMStextalerts.(andyoualsoneedtohavethe#CTR=1
alarmfunctionturnedOn)
Thisalarmisactivatedbyapplyinga12VoltDCsupplytothealarmInputconnectionforaperiodof5seconds
andtocustomizetheSMSMessageyouwouldsendthefollowingSMSMessagetotheunitassumingthe
requiredmessageistobe“GateForced”
#PWD654321#STR=”GateForced”andyoushouldreceivethefollowingSMSmessagefromtheunitifsent
correctly.STR:“GateForced”andthisSMSMessagewillnowbesenttotheadministratorsfromthe#TELlist
thatareprogrammedintheMatrixtoreceivetheSMStextalerts.
SettinguptheAlarmInputMessagewhenDe‐activated
ItisalsopossibletoProgramanalarmmessagethatissentwhenthealarmInputreturnstonormalstatusor
AlarmPowerisremovedandtosetthefollowingmessageas“Gatelockedagain”youwouldsendthefollowing
messagetotheunit.
#PWD654321#STO=”Gatelockedagain”andyoushouldreceivethefollowingSMSmessagefromtheunitifsent
correctly.STR:“Gatelockedagain”andthisSMSMessagewillnowbesenttotheadministratorsfromthe#TEL
listthatareprogrammedintheMatrixtoreceivetheSMStextalerts.