WOERNER VPA-C User manual

Data sheet P0688.10.13 EN
Replaces P0688.07.13 EN
Page 1 of 7
Data sheet P0688 EN
Page 2 of 7
Progressive distributor
WOERNER
In progressive mode based central lubri-
cation systems
The main features of
progressive distributors are as follows
Clear and precise arrangement of
control channels in
Quick fault remedy possible without
having to loosen the pipeline
selectable in accordance with the
lubricant required
due to
refined sliding surfaces
can be replaced during operation
Proportioning volume
per cycle
Lubrication point
connections at max.
Operating pressure at
Throughput volume in case of
Material
Proportioning block
Internal parts
Connecting plate
Delivery medium
Mounting position usually as needed
Note: In case of heavy vibration or
shock load, install the distributor such
that piston axes are situated vertically to
the main direction of shock impact.
An optimum ventilation of the whole
lubrication system is the precondition
for its functionally safe operation.
For quicker ventilation, the flow direc-
tion from bottom to top in the distributor
is of advantage (inlet on bottom side).
The distributor must not be "distorted".
Therefore, when mounting it, always be
careful that the supporting surface is
level.
VPA-C
Use:
Technical data:
:
: 0,1 ... 0,9 cm³
: 20
max.: 150 bar
Oil at max.: 2500 cm³/min
Grease at max.: 250 cm³/min
: Aluminium
: Steel
: Aluminium
Temperature range: -20 ...
on request 0,05 cm³
Oil-viscosity: >6 cP
Grease: up to NLGI category 2
+80 °C
:
+
+
+
+
+
+
Accurate proportioning volumes
Modular system construction
9 different proportioning volumes
Extremely long service life
Pluggable monitoring elements
spite of small-size
construction
+No proportioning decrease at the
piston monitored
Progressive distributor VPA-C
205.000
Progressive distributor VPA-C
205.000
A1=
A2=
B =
)
D = DPA-C
H = Main line
K =
M = 2x
(see data sheets P0683)
R = APA-C
S =
Mounting position at the distributor (for
visual indication and electrical checking
device) at first place
Mounting position at the distributor (for
electrical checking device) at last place
Mounting point for viewing indicator at
distributor (if point A is occupied
Proportioning block
Proportioning volume distinctive number
M8 fastening threads for assembly
of auxiliary units
Connecting plate
Mid fastening screw
130 1,30
6
152 1,658
174 2,0010
202 2,3012
224 2,6014
246 2,9016
268 3,2518
290 3,6020
Length
"a"
Weight
kg
Number
of outlets
-
-
-
92
114
114
136
136
Length
"s"
Casing for initiator
Visual check "S"
Functional checks
Visual check "S"
In a translucent polyamide casing, a red pin
being fixed to the piston shows the piston's
movement.
Casing material: Polyamide, translucent
Ambient temperature: -10 ... +80 °C
Weight: 0,35 kg
Mounting point at distributor: Aor B
:
:
Electrical check with initiator:
Casing for initiator:
A pin being connected with the piston
attenuates an initiator once per cycle.
Version "D":
Casing material: Polyamide, translucent
(Piston movement is visible)
for initiators with a
switching distance of: 8 mm
Version "W":
Casing material: Polyamide, black
for initiators with a
switching distance of: 5 mm
Use initiator with M18x1 thread!
(When using other initiators than those
depicted below, such initiators must be
checked for suitability.)
³
³
Choice of initiators:
Operating voltage:
Connection diagram:
Dimension drawing:
Initiator "C"
913.900-03
10 ... 30 VDC
Residual ripple: £10%
Load current at max.: 250 mA
Protection system: IP67
Power connection: Cable 3 m Unit plug ( 3)see accessoires page
Length "A": 76,5 mm
Designation /
Purchase-no.
10 ... 30 VDC
£15%
130 mA
IP67
45 mm
Initiator "N"
913.900-21
Switching :distance 8 mm 8 mm
G 1/41)
1) Base plates threaded G 1/8
see data sheet S0688
- Subject to modifications -
- Subject to modifications -
EUGEN WOERNER GmbH & Co. KG
Postfach 1661 DE-97866 Wertheim
Hafenstrasse 2 DE-97877 Wertheim
Tel. +49 9342 803-0
Fax.+49 9342 803-202 www.woerner.de
info@woerner.de
EUGEN WOERNER GmbH & Co. KG
Postfach 1661 DE-97866 Wertheim
Hafenstrasse 2 DE-97877 Wertheim
Tel. +49 9342 803-0
Fax.+49 9342 803-202 www.woerner.de
info@woerner.de

Data sheet P0688.10.13 EN
Replaces P0688.07.13 EN
Page 1 of 7
Data sheet P0688 EN
Page 2 of 7
Progressive distributor
WOERNER
In progressive mode based central lubri-
cation systems
The main features of
progressive distributors are as follows
Clear and precise arrangement of
control channels in
Quick fault remedy possible without
having to loosen the pipeline
selectable in accordance with the
lubricant required
due to
refined sliding surfaces
can be replaced during operation
Proportioning volume
per cycle
Lubrication point
connections at max.
Operating pressure at
Throughput volume in case of
Material
Proportioning block
Internal parts
Connecting plate
Delivery medium
Mounting position usually as needed
Note: In case of heavy vibration or
shock load, install the distributor such
that piston axes are situated vertically to
the main direction of shock impact.
An optimum ventilation of the whole
lubrication system is the precondition
for its functionally safe operation.
For quicker ventilation, the flow direc-
tion from bottom to top in the distributor
is of advantage (inlet on bottom side).
The distributor must not be "distorted".
Therefore, when mounting it, always be
careful that the supporting surface is
level.
VPA-C
Use:
Technical data:
:
: 0,1 ... 0,9 cm³
: 20
max.: 150 bar
Oil at max.: 2500 cm³/min
Grease at max.: 250 cm³/min
: Aluminium
: Steel
: Aluminium
Temperature range: -20 ...
on request 0,05 cm³
Oil-viscosity: >6 cP
Grease: up to NLGI category 2
+80 °C
:
+
+
+
+
+
+
Accurate proportioning volumes
Modular system construction
9 different proportioning volumes
Extremely long service life
Pluggable monitoring elements
spite of small-size
construction
+No proportioning decrease at the
piston monitored
Progressive distributor VPA-C
205.000
Progressive distributor VPA-C
205.000
A1=
A2=
B =
)
D = DPA-C
H = Main line
K =
M = 2x
(see data sheets P0683)
R = APA-C
S =
Mounting position at the distributor (for
visual indication and electrical checking
device) at first place
Mounting position at the distributor (for
electrical checking device) at last place
Mounting point for viewing indicator at
distributor (if point A is occupied
Proportioning block
Proportioning volume distinctive number
M8 fastening threads for assembly
of auxiliary units
Connecting plate
Mid fastening screw
130 1,30
6
152 1,658
174 2,0010
202 2,3012
224 2,6014
246 2,9016
268 3,2518
290 3,6020
Length
"a"
Weight
kg
Number
of outlets
-
-
-
92
114
114
136
136
Length
"s"
Casing for initiator
Visual check "S"
Functional checks
Visual check "S"
In a translucent polyamide casing, a red pin
being fixed to the piston shows the piston's
movement.
Casing material: Polyamide, translucent
Ambient temperature: -10 ... +80 °C
Weight: 0,35 kg
Mounting point at distributor: Aor B
:
:
Electrical check with initiator:
Casing for initiator:
A pin being connected with the piston
attenuates an initiator once per cycle.
Version "D":
Casing material: Polyamide, translucent
(Piston movement is visible)
for initiators with a
switching distance of: 8 mm
Version "W":
Casing material: Polyamide, black
for initiators with a
switching distance of: 5 mm
Use initiator with M18x1 thread!
(When using other initiators than those
depicted below, such initiators must be
checked for suitability.)
³
³
Choice of initiators:
Operating voltage:
Connection diagram:
Dimension drawing:
Initiator "C"
913.900-03
10 ... 30 VDC
Residual ripple: £10%
Load current at max.: 250 mA
Protection system: IP67
Power connection: Cable 3 m Unit plug ( 3)see accessoires page
Length "A": 76,5 mm
Designation /
Purchase-no.
10 ... 30 VDC
£15%
130 mA
IP67
45 mm
Initiator "N"
913.900-21
Switching :distance 8 mm 8 mm
G 1/41)
1) Base plates threaded G 1/8
see data sheet S0688
- Subject to modifications -
- Subject to modifications -
EUGEN WOERNER GmbH & Co. KG
Postfach 1661 DE-97866 Wertheim
Hafenstrasse 2 DE-97877 Wertheim
Tel. +49 9342 803-0
Fax.+49 9342 803-202 www.woerner.de
info@woerner.de
EUGEN WOERNER GmbH & Co. KG
Postfach 1661 DE-97866 Wertheim
Hafenstrasse 2 DE-97877 Wertheim
Tel. +49 9342 803-0
Fax.+49 9342 803-202 www.woerner.de
info@woerner.de

Data sheet P0688 EN
Page 4 of 7
Data sheet P0688 EN
Page 3 of 7
Purchase-example:
Purchase-designation
(for the distributor as depicted here)
Progressive distributor with 12 outlets,
without visual check "0", with casing for
initiator "W" and initiator "C", proportioning
distinctive numbers "22", "50", "63", "30",
"30", "63", gasket material "P".
:
VPA-C . B / A12 / 0 / W / C / 22 / 50 / 63 /
30 / 30 / 63 / P
Side A (R) : P / P / A/ V / 0 / 0
Centre : K / K / Z / K / Z / Z
Side B (L) : B / B / 0 / 0 / B / A
Cable jack with LED and cable:
913.404-19
Cable jack with terminal clamps:
(without LED)
913.404-24
Purchase-no.:
Operating voltage: 10 ... 30 VDC
Cable
Cross section: 3x0,34 mm²
Leng h: 5 m
System of protection: IP68
Purchase-no.:
Connection type: Screws
Connection cross
section: at 0,75 mm²
Cable diameter: 4 ... 6 mm
System of protection: IP67
t
max.
Electrical check
with reed contact:
Version "R"
with plug-in connection
DIN EN 175301-803, shape A:
Version "RK"
with cable:
Version "RS"
with unit plug, 4-pin (M12):
A magnet connected with the piston
switches the reed contact once per cycle.
Switching voltage: 10 ... 36 VUC
Switching current at max.: 25 mA
Switching power at max.: 0,9 VA
Ambient temperature: -5 ... +80 °C
Mounting point at distributor: A
Material (casing): Al or 1.4305
System of protection: IP65
Connection
diagram:
Material (receptacle): PA or 1.4305
System of protection: IP65
Cable
Length: 10 m
Cross section: 2x0,75 mm²
Material: Oil flex
Connection
diagram:
(for matching cable jack see accessories)
Material (casing): PA or 1.4305
Connection
diagram:
Progressive distributor VPA-C
205.000
Progressive distributor VPA-C
205.000
Version "R"
Version "RK"
Version "RS"
Cable jack with LED and cable Cable jack with terminal clamps
Accessories:
(state purchase-no., please)
Cable jack for functionality check "RS" and initiator
LED yellow = function display
green = operating voltage
100 W
100 W
100 W
Distributor view Scheme
SideA(R)
Centre
Side B (L)
Please note:
!
1)
2)
!
!
When mounting a functional checking device at the 1st place, metering volume at the last place must be 0,22 cm³ at least
When mounting a functional checking device at the last place, metering volume at the last but one place must be 0,22 cm³ at
least
3) Resistance of the transparent case of the proximity switch "D" to synthetic lubricants and additives as well as to other consum-
ables cannot be assured. The application under the planned conditions of operation, as fundamental rule, has to be checked. If
required, the reinforced case "W" is to be used. If additional sight check is wanted, then the visual indicator "S" can be installed
Informations regard data sheet S0688
.
4)
Purchase-designation:
Progressive distributor
Purchase-designation Proportioning block:
Purchase-designation Connecting plate:
DPA-C
(internal)
VPA-C .B
APA-C .B
without 0,10 0,50
0,22
0,63
0,30
0,75
0,40 0,05
on re-
quest4)
0,90
Reed
contact
translucent
initiator casing
Switching
distance 8 mm³
reinforced
initiator casing
Switching
distance 5 mm³
NBR
(Perbunan)
FPM
(Viton)
0,15
D
W
without
3)
C
N
Number
of outlets
Functionality
check electrical check Initiator
Proportioning volume
per piston stroke
and outlet in cm³
Gasket material
Base plate
with outlet
thread G 1/4:
A6 ... A20
2 outlets
each
increasing by
Base plate
with outlet thread
G 1/8 on request
(data sheet S0688)
without
Visual check
with S
0
last
place2)
0
Z
Electrical
checking device
mounted at
1st
place1)
- Subject to modifications -
- Subject to modifications -
EUGEN WOERNER GmbH & Co. KG
Postfach 1661 DE-97866 Wertheim
Hafenstrasse 2 DE-97877 Wertheim
Tel. +49 9342 803-0
Fax.+49 9342 803-202 www.woerner.de
info@woerner.de
EUGEN WOERNER GmbH & Co. KG
Postfach 1661 DE-97866 Wertheim
Hafenstrasse 2 DE-97877 Wertheim
Tel. +49 9342 803-0
Fax.+49 9342 803-202 www.woerner.de
info@woerner.de

Data sheet P0688 EN
Page 4 of 7
Data sheet P0688 EN
Page 3 of 7
Purchase-example:
Purchase-designation
(for the distributor as depicted here)
Progressive distributor with 12 outlets,
without visual check "0", with casing for
initiator "W" and initiator "C", proportioning
distinctive numbers "22", "50", "63", "30",
"30", "63", gasket material "P".
:
VPA-C . B / A12 / 0 / W / C / 22 / 50 / 63 /
30 / 30 / 63 / P
Side A (R) : P / P / A/ V / 0 / 0
Centre : K / K / Z / K / Z / Z
Side B (L) : B / B / 0 / 0 / B / A
Cable jack with LED and cable:
913.404-19
Cable jack with terminal clamps:
(without LED)
913.404-24
Purchase-no.:
Operating voltage: 10 ... 30 VDC
Cable
Cross section: 3x0,34 mm²
Leng h: 5 m
System of protection: IP68
Purchase-no.:
Connection type: Screws
Connection cross
section: at 0,75 mm²
Cable diameter: 4 ... 6 mm
System of protection: IP67
t
max.
Electrical check
with reed contact:
Version "R"
with plug-in connection
DIN EN 175301-803, shape A:
Version "RK"
with cable:
Version "RS"
with unit plug, 4-pin (M12):
A magnet connected with the piston
switches the reed contact once per cycle.
Switching voltage: 10 ... 36 VUC
Switching current at max.: 25 mA
Switching power at max.: 0,9 VA
Ambient temperature: -5 ... +80 °C
Mounting point at distributor: A
Material (casing): Al or 1.4305
System of protection: IP65
Connection
diagram:
Material (receptacle): PA or 1.4305
System of protection: IP65
Cable
Length: 10 m
Cross section: 2x0,75 mm²
Material: Oil flex
Connection
diagram:
(for matching cable jack see accessories)
Material (casing): PA or 1.4305
Connection
diagram:
Progressive distributor VPA-C
205.000
Progressive distributor VPA-C
205.000
Version "R"
Version "RK"
Version "RS"
Cable jack with LED and cable Cable jack with terminal clamps
Accessories:
(state purchase-no., please)
Cable jack for functionality check "RS" and initiator
LED yellow = function display
green = operating voltage
100 W
100 W
100 W
Distributor view Scheme
SideA(R)
Centre
Side B (L)
Please note:
!
1)
2)
!
!
When mounting a functional checking device at the 1st place, metering volume at the last place must be 0,22 cm³ at least
When mounting a functional checking device at the last place, metering volume at the last but one place must be 0,22 cm³ at
least
3) Resistance of the transparent case of the proximity switch "D" to synthetic lubricants and additives as well as to other consum-
ables cannot be assured. The application under the planned conditions of operation, as fundamental rule, has to be checked. If
required, the reinforced case "W" is to be used. If additional sight check is wanted, then the visual indicator "S" can be installed
Informations regard data sheet S0688
.
4)
Purchase-designation:
Progressive distributor
Purchase-designation Proportioning block:
Purchase-designation Connecting plate:
DPA-C
(internal)
VPA-C .B
APA-C .B
without 0,10 0,50
0,22
0,63
0,30
0,75
0,40 0,05
on re-
quest4)
0,90
Reed
contact
translucent
initiator casing
Switching
distance 8 mm³
reinforced
initiator casing
Switching
distance 5 mm³
NBR
(Perbunan)
FPM
(Viton)
0,15
D
W
without
3)
C
N
Number
of outlets
Functionality
check electrical check Initiator
Proportioning volume
per piston stroke
and outlet in cm³
Gasket material
Base plate
with outlet
thread G 1/4:
A6 ... A20
2 outlets
each
increasing by
Base plate
with outlet thread
G 1/8 on request
(data sheet S0688)
without
Visual check
with S
0
last
place2)
0
Z
Electrical
checking device
mounted at
1st
place1)
- Subject to modifications -
- Subject to modifications -
EUGEN WOERNER GmbH & Co. KG
Postfach 1661 DE-97866 Wertheim
Hafenstrasse 2 DE-97877 Wertheim
Tel. +49 9342 803-0
Fax.+49 9342 803-202 www.woerner.de
info@woerner.de
EUGEN WOERNER GmbH & Co. KG
Postfach 1661 DE-97866 Wertheim
Hafenstrasse 2 DE-97877 Wertheim
Tel. +49 9342 803-0
Fax.+49 9342 803-202 www.woerner.de
info@woerner.de

Data sheet P0688 EN
Page 6 of 7
Data sheet P0688 EN
Page 5 of 7
I
II
III
1
2
3
4
5
6
Left-side
bypass line
Right-side
linebypass
Main line
Fig. 1
IIII
1
2
3
4
5
6
Fig. 3
I
1
2
3
4
5
6
Fig. 2
III
1
2
3
4
5
6
Fig. 4
Monitoring of
progressive distributors
As for instance due to soiling, the flow
through a lubricant point line may be
prevented. This will cause a piston to get
blocked. By virtue of the forced control as
depicted in figures 1 up to 4, the other
pistons will be stopped as well.
Due to this configuration, the proportioning
at all outlets of the distributor can be
monitored by means of a sensor at one
piston only.
Mounting note:
The pistons are provided with an extremely
small fitting clearance. Therefore, the pis-
tons, after the dismantling of a distributor,
must never be interchanged.
Distinctive letters
ouble bridge without
check valve
riple bridge without
check valve
utlet at the bridge
without check valve
opposing outlets
separated
opposing outlets
connected
open outlet
ock screw
:
B = D
P = T
A = O
Z =
K =
0 =
V = L
Setting of the initiator:
1. Switching on the pump (distributor
circulates).
2. Screwing the initiator completely in. In
the case of a permanent signal, turning
back the initiator as far as an alternating
signal occurs.
3. Turning back the initiator until no signal is
released.
4. Setting the initiator between the limit
values 2 (alternating) and 3 (no
signal)
5. Secure the initiator with a counter nut.
" " "
".
Progressive distributor VPA-C
205.000
Progressive distributor VPA-C
205.000
Combination of outlets,
doubling the proportioning volume at an outlet:
Connect opposing outlets by removing the "Z" screw.
Close any of the outlets by means of a screwed sealing plug
Without removal of the "Z" screw, no outlet must be locked.
.
Z
2 adjacent outlets are combined into
one outlet by means of a double
bridge.
Add-on elements and combination of outlets:
5 outlets are combined into one outlet
by means of a triple bridge, a double
bridge, and removal of the "Z" screws.
Open outlets
2 opposing outlets are combined by
removing the "Z" screws.
SideA(R)
Centre
Side B (L)
Accessories
Pipe screw fittings
:
DIN 2353 and lock screw:
.
( )
please state purchase-no.
Only in conjunction with progressive distributor. For spare parts see spare part list E0117
Bridges: (please state purchase-no.)
double without
outlet (B-B)
triple without
outlet (P-P-P)
double with
outlet (B-A)
triple with
outlet (P-P-A)
752.205-90 752.205-91 752.205-92 752.205-93
Bridges
double without
outlet (B-B)
triple without
outlet (P-P-P)
double with
outlet (B-A)
triple with
outlet (P-P-A)
752.205-94 752.205-95 752.205-96 752.205-97
Bridges ( "S")location of the mid fastening screw
For mid fastening screw "S" position
––752.205-98 752.205-99 – – 752.205-A0 752.205-A1
without
with
Check valve
at the outlet
1) Outlet at max ø10
Connection
thread
G 1/4 951.100-51 951.100-12 951.100-14 951.100-17
68 10 12
Pipe screw fitting with pipe outer diameterø 1)
206.674-65
Check valve with pipe outer diameterø
501.152-65 501.151-65 501.153-65
68 10
Lock screw
"V"
Functional process fig. 1 ... 4:
The lubricant flows from the main line
through the right-side ring groove of piston
III as well as the bypass line (right) and to
the left side of piston I and moves it into its
home position. The lubricant displaced by
piston I is ejected via the left bypass line
through outlet no. 6
After shifting of piston I, lubricant flows to
the left side of piston II and pushes it into its
right-side home position. The displaced
lubricant is ejected via outlet no. 1
After shifting of piston II, lubricant flows to
the left side of piston III and pushes it into its
right-side home position. The displaced
lubricant is ejected via outlet no. 2
After shifting of piston III, lubricant flows to
the right side of piston I and pushes it into its
left-side home position. The displaced
lubricant is ejected via outlet no. 3. The
continuation of that process is evidenced in
the scheme depicted
.
.
.
.
Formula for calculating the lubricant
available per lubrication point:
A progressive distributor allocates the
delivered lubricant to the individual lubri-
cation points in forced order. Due to the
functional process as described herein, a
safe proportioning is ensured
The lubricant delivered to a lubrication
point i can be calculated as follows
lubricant delivered to the distributor
.
Q = ,
K = i
idistinctive number of the outlet
qi
q = Q
i¾¾¾¾¾¾¾¾ *
Ki
2 (K +K +K ...)*1 2 3
- Subject to modifications -
- Subject to modifications -
EUGEN WOERNER GmbH & Co. KG
Postfach 1661 DE-97866 Wertheim
Hafenstrasse 2 DE-97877 Wertheim
Tel. +49 9342 803-0
Fax.+49 9342 803-202 www.woerner.de
info@woerner.de
EUGEN WOERNER GmbH & Co. KG
Postfach 1661 DE-97866 Wertheim
Hafenstrasse 2 DE-97877 Wertheim
Tel. +49 9342 803-0
Fax.+49 9342 803-202 www.woerner.de
info@woerner.de

Data sheet P0688 EN
Page 6 of 7
Data sheet P0688 EN
Page 5 of 7
I
II
III
1
2
3
4
5
6
Left-side
bypass line
Right-side
linebypass
Main line
Fig. 1
IIII
1
2
3
4
5
6
Fig. 3
I
1
2
3
4
5
6
Fig. 2
III
1
2
3
4
5
6
Fig. 4
Monitoring of
progressive distributors
As for instance due to soiling, the flow
through a lubricant point line may be
prevented. This will cause a piston to get
blocked. By virtue of the forced control as
depicted in figures 1 up to 4, the other
pistons will be stopped as well.
Due to this configuration, the proportioning
at all outlets of the distributor can be
monitored by means of a sensor at one
piston only.
Mounting note:
The pistons are provided with an extremely
small fitting clearance. Therefore, the pis-
tons, after the dismantling of a distributor,
must never be interchanged.
Distinctive letters
ouble bridge without
check valve
riple bridge without
check valve
utlet at the bridge
without check valve
opposing outlets
separated
opposing outlets
connected
open outlet
ock screw
:
B = D
P = T
A = O
Z =
K =
0 =
V = L
Setting of the initiator:
1. Switching on the pump (distributor
circulates).
2. Screwing the initiator completely in. In
the case of a permanent signal, turning
back the initiator as far as an alternating
signal occurs.
3. Turning back the initiator until no signal is
released.
4. Setting the initiator between the limit
values 2 (alternating) and 3 (no
signal)
5. Secure the initiator with a counter nut.
" " "
".
Progressive distributor VPA-C
205.000
Progressive distributor VPA-C
205.000
Combination of outlets,
doubling the proportioning volume at an outlet:
Connect opposing outlets by removing the "Z" screw.
Close any of the outlets by means of a screwed sealing plug
Without removal of the "Z" screw, no outlet must be locked.
.
Z
2 adjacent outlets are combined into
one outlet by means of a double
bridge.
Add-on elements and combination of outlets:
5 outlets are combined into one outlet
by means of a triple bridge, a double
bridge, and removal of the "Z" screws.
Open outlets
2 opposing outlets are combined by
removing the "Z" screws.
SideA(R)
Centre
Side B (L)
Accessories
Pipe screw fittings
:
DIN 2353 and lock screw:
.
( )
please state purchase-no.
Only in conjunction with progressive distributor. For spare parts see spare part list E0117
Bridges: (please state purchase-no.)
double without
outlet (B-B)
triple without
outlet (P-P-P)
double with
outlet (B-A)
triple with
outlet (P-P-A)
752.205-90 752.205-91 752.205-92 752.205-93
Bridges
double without
outlet (B-B)
triple without
outlet (P-P-P)
double with
outlet (B-A)
triple with
outlet (P-P-A)
752.205-94 752.205-95 752.205-96 752.205-97
Bridges ( "S")location of the mid fastening screw
For mid fastening screw "S" position
––752.205-98 752.205-99 – – 752.205-A0 752.205-A1
without
with
Check valve
at the outlet
1) Outlet at max ø10
Connection
thread
G 1/4 951.100-51 951.100-12 951.100-14 951.100-17
68 10 12
Pipe screw fitting with pipe outer diameterø 1)
206.674-65
Check valve with pipe outer diameterø
501.152-65 501.151-65 501.153-65
68 10
Lock screw
"V"
Functional process fig. 1 ... 4:
The lubricant flows from the main line
through the right-side ring groove of piston
III as well as the bypass line (right) and to
the left side of piston I and moves it into its
home position. The lubricant displaced by
piston I is ejected via the left bypass line
through outlet no. 6
After shifting of piston I, lubricant flows to
the left side of piston II and pushes it into its
right-side home position. The displaced
lubricant is ejected via outlet no. 1
After shifting of piston II, lubricant flows to
the left side of piston III and pushes it into its
right-side home position. The displaced
lubricant is ejected via outlet no. 2
After shifting of piston III, lubricant flows to
the right side of piston I and pushes it into its
left-side home position. The displaced
lubricant is ejected via outlet no. 3. The
continuation of that process is evidenced in
the scheme depicted
.
.
.
.
Formula for calculating the lubricant
available per lubrication point:
A progressive distributor allocates the
delivered lubricant to the individual lubri-
cation points in forced order. Due to the
functional process as described herein, a
safe proportioning is ensured
The lubricant delivered to a lubrication
point i can be calculated as follows
lubricant delivered to the distributor
.
Q = ,
K = i
idistinctive number of the outlet
qi
q = Q
i¾¾¾¾¾¾¾¾ *
Ki
2 (K +K +K ...)*1 2 3
- Subject to modifications -
- Subject to modifications -
EUGEN WOERNER GmbH & Co. KG
Postfach 1661 DE-97866 Wertheim
Hafenstrasse 2 DE-97877 Wertheim
Tel. +49 9342 803-0
Fax.+49 9342 803-202 www.woerner.de
info@woerner.de
EUGEN WOERNER GmbH & Co. KG
Postfach 1661 DE-97866 Wertheim
Hafenstrasse 2 DE-97877 Wertheim
Tel. +49 9342 803-0
Fax.+49 9342 803-202 www.woerner.de
info@woerner.de

Data sheet EN
Page 8 of 8
Data sheet P0688 EN
Page 7 of 7
Technical documents also valid for this product:
B0336 Operating instructions VP
Important information about this data sheet
Reproduction, also in extracts, only permitted with the approval of the firm of EUGEN
WOERNER GmbH & Co. KG.
All the information in this data sheet has been examined for correctness with great care.
Nevertheless, WOERNER cannot assume any liability for losses or damage resulting
directly or indirectly from the application of the information contained in this data sheet.
All products from WOERNER may only be used as intended and corresponding to the
information in this data sheet.
For products supplied with operating instructions, the additional directives and information
contained in them are to be complied with.
Materials deviating from those mentioned in this data sheet and the technical documents
which further apply may only be poured into and processed in the appliances and systems
manufactured and supplied by WOERNER by following agreement with and written
approval by WOERNER.
The safety and danger information stated in the safety data sheets of the substances used
must be taken into account at all costs.
Transportation of gases, liquefied gases, gases under pressure, vapours and liquids, the
vapour pressure of which is more than 0,5 bar above normal atmospheric pressure
(1013 mbar) at the maximum admissible temperature, of easy inflammable or explosive
media as well as transportation of foodstuffs is forbidden.
With Directive 2002/95/EC of January 27, 2003, for the limitation of the use of certain
hazardous substances in electrical and electronic devices (RoHS) material bans come into
effect from July 2006 for electrical and electronic devices newly placed on the market for
lead, cadmium, hexavalent chromium, mercury and brominated flame retardants.
In its controls and switching devices, WOERNER only uses materials which fulfil the criteria
of EU Directive 2002/95/EC.
To the extent that hexavalent chromium has been used as corrosion protection in the parts
which we produce ourselves, it has already been replaced by other environmentally
tolerable protective measures.
The mechanical devices supplied by WOERNER are not affected by EU Directive
2002/95/EC.
But as WOERNER is conscious of its responsibility towards the environment, we shall also
use materials fulfilling the requirements of the Directive for devices not covered by EU
Directive 2002/95/EC as soon as they are generally available and their use is technically
possible.
Information on EU Directive 2002/95/EC (RoHS)
Progressive distributor VPA-C
205.000
- Subject to modifications -
- Subject to modifications -
EUGEN WOERNER GmbH & Co. KG
Postfach 1661 DE-97866 Wertheim
Hafenstrasse 2 DE-97877 Wertheim
Tel. +49 9342 803-0
Fax.+49 9342 803-202 www.woerner.de
info@woerner.de
EUGEN WOERNER GmbH & Co. KG
Postfach 1661 DE-97866 Wertheim
Hafenstrasse 2 DE-97877 Wertheim
Tel. +49 9342 803-0
Fax.+49 9342 803-202 www.woerner.de
info@woerner.de
Other WOERNER Lubrication System manuals