Industrial 8-port Unmanaged
Ethernet Switch
DS108
・  Overview
・  Installation
・  Appearance
DIP
ON
OFF
BS
[ON] Enable Broadcast
Storm Protection Function
[OFF] Disable Broadcast
Storm Protection Function
[ON] Enable Quality of
Service Function
[OFF] Disable Quality of
Service Function
QoS
Model Name
DS108
DS108-MM-SC-2
DS108-MM-ST-2
DS108-SS-SC-30
DS108-SS-ST-30
Description
Industrial 8-port Unmanaged Ethernet Switch
Industrial 8-port Unmanaged Ethernet Switch,
multi-mode, 2km/1310nm, SC
Industrial 8-port Unmanaged Ethernet Switch,
single-mode, 30km/1310nm, ST
Industrial 8-port Unmanaged Ethernet Switch,
multi-mode, 2km/1310nm, ST
Industrial 8-port Unmanaged Ethernet Switch,
single-mode, 30km/1310nm, SC
・  Package Checklist
。1 x Product Unit
。1 x 4-pin Removable Terminal Connector
。1 x Attached Din Clip
。1 x Quick Installation Guide
Optional Accessory (for detailed information please refer to the Datasheet)
www.womaster.eu
Quick Installation Guide
DS108 Series are industrial unmanaged Ethernet switches that enabled
to expand industrial network faster and cost-effectively. Where DS108
equipped with 8-port Fast Ethernet with 10/100Mbps speed and
additionally for DS108-MM that provides two multi-mode fiber-optic ports
while DS108-SS provides two single-mode fiber-optic ports. By using
fiber-optics, it can prevent noise from interfering with system and
supports high-speed (100 Mbps) and high-distance (up to 30 km)
transmissions. DS108 Series has robust designs, assuring high reliability
and stability in harsh environments.
DIN Rail mount
To mount the switch on the DIN Rail track, insert
the upper end of the DIN-Rail clip into the back of
the DIN-Rail track from its upper side and lightly
push the bottom of the DIN-Rail clip into the
track. The DIN Rail should comply with DIN
EN50022 standard. Using wrong DIN rail may
cause unsafe installation.
Wiring the Grounding
For avoiding system damage by noise or electric
shock, establish a direct connection by insert the
grounding wire into the GND contact on the
terminal block connector, then tighten the
wire-clamp screws.
Fiber Ports (SC/ST)
DS108 Series switches are equipped with fiber ports. To connect the
fiber port, remember to link the Tx (transmit) port to the Rx (receive) port
of the receiving device, and the Rx (receive) port to the Tx (transmit) port
of transmitting device.
Warning: Be careful when connecting the fiber port, wrong connec-
tion will cause the fiber port not working properly.
The picture below shows the fiber ports SC and ST appearance.
DIN Rail Clip
GND
DIP Switch Setting
In addition, the DS108 Series switches have DIP switches
for enabling or disabling broadcast storm protection,
providing another level of data transmission quality for
industrial applications. The table below shows how the
DIP-switch pin number is assigned to broadcast storm
protection and quality of service function.
Wiring the Power Inputs
1) Insert the positive and negative wires into 3
pin V+, V- and V+ contact on the terminal block
connector.
2) Tighten the wire-clamp screws.
3) Connect the power wires to suitable DC
Switching type power supply. The input DC
voltage should be in the range of 9.6VDC to
60VDC.
P
TX
RX
TX
RX
SC-Ports Pinouts ST-Ports Pinouts
DIN Rail Clip
Power Connector
・1 x 4-pin Terminal Block
3 pin for Power Input
1 pin for Grounding
System LED
・1 x Power
・2 x Fiber Port
2 x 100BaseFX
(SC/ST Connector)
6 x 10/100Base-TX
DIP Switch
・1 x Broadcast Storm Protection
・1 x QoS
DIN Rail Clip
Power Connector
・1 x 4-pin Terminal Block
3 pin for Power Input
1 pin for Grounding
System LED
・1 x Power
8 x 10/100Base-TX
DIP Switch
・1 x Broadcast Storm Protection
・1 x QoS
DS108 MM/SS
DS108
BS QoS
ON
1 2
・  Disclaimer
LED
Power
Ethernet
(Port 1-8)
Fiber Port
(Port 7-8)
DS108-MM/SS
Status
Green On
Off
Green On
DC-IN Power is On
No Power in DC-IN
Links established
Green On
Green Blinkling
Links established
Packets transmitting/receiving
Green Blinkling Packets transmitting/receiving
Green Off Link is inactive
Green Off Link is inactive
Description
・  Safety Precautions
.Turn off DC power input source before connecting the DC Power
supply module to the terminal block connectors. Do not turn-on the
source of DC power module and make sure all connections were well
established, then power on the DC source to powering the Switch
device.
.Never install or work on/with the equipment or the cabling during the
period of its lightning activity.
.The DIN Rail should comply with DIN EN50022 standard. Using wrong
DIN rail may cause unsafe installation.
・  Support
At WoMaster, you can use the online service forms to request the
support. The submitted forms are stored in server for WoMaster team
member to assign tasks and monitor the status of your service. Please
feel free to write to help@womaster.eu if you encounter any problems.
・  Warranty
5-year Global warranties are available for WoMaster products assuring
our customers that the products shall remain free from defects in
workmanship or materials and conform in all material respects to WoMas-
ter specifications, or Purchaser’s supplied and accepted specifications.
The warranty is limited to the repair and/or replacement, at WoMaster'
sole discretion, of the defective product during its warranty period. The
customer must obtain a Return Merchandise Authorization (RMA)
approval code prior to returning the defective Product to WoMaster for
service. The customer agrees to prepay shipping charges, to use the
original shipping container or equivalent, and to insure the Product or
assume the risk of loss or damage in transit. Repaired or replaced
products are warranted for ninety (90) days from the date of repair or
replacement, or for the remainder of the original product's warranty
period, whichever is longer.
WoMaster reserves the right to make changes to this QIG or to the
product hardware at any time without notice. It is the user’s responsibility
to determine whether there have been any such updates or amendments
herein.
Defects, malfunctions, or failures of the warranted Product(s) caused by
damage resulting from unforeseeable incidents (such as lightings, floods,
fire, etc.), environmental and atmospheric disturbances, other external
forces such as power line disturbances and surge, host computer
malfunction and virus, incorrect power input, or incorrect cabling, incorrect
grounding and damages caused by misuse, abuse and unauthorized
alteration or repair are not warranted.
V1.0 Jan 3, 2018 3160-0DS1080-00 www.womaster.eu© WoMaster Inc. All rights reserved.
・  LED Indication
PWR PWR 7 8
Port
DS108 DS108-MM/SS

This manual suits for next models

4

Other WoMaster Switch manuals

WoMaster RS428 User manual

WoMaster

WoMaster RS428 User manual

WoMaster RP428 User manual

WoMaster

WoMaster RP428 User manual

WoMaster DS410F User manual

WoMaster

WoMaster DS410F User manual

WoMaster DP310 User manual

WoMaster

WoMaster DP310 User manual

WoMaster DP208 User manual

WoMaster

WoMaster DP208 User manual

WoMaster DP612 User manual

WoMaster

WoMaster DP612 User manual

WoMaster MP614 Series User manual

WoMaster

WoMaster MP614 Series User manual

WoMaster DS105 User manual

WoMaster

WoMaster DS105 User manual

Popular Switch manuals by other brands

Cisco Aironet 350 Series Administration guide

Cisco

Cisco Aironet 350 Series Administration guide

Lenovo RackSwitch G8272 Product guide

Lenovo

Lenovo RackSwitch G8272 Product guide

Planet Networking & Communication IGS-5225-8T2S2X user manual

Planet Networking & Communication

Planet Networking & Communication IGS-5225-8T2S2X user manual

Vega VEGACAP 66 operating instructions

Vega

Vega VEGACAP 66 operating instructions

Comtech EF Data CDS-100 quick start guide

Comtech EF Data

Comtech EF Data CDS-100 quick start guide

Pilz PSEN cs1.13p operating instructions

Pilz

Pilz PSEN cs1.13p operating instructions

HP Q.11.XX Guide

HP

HP Q.11.XX Guide

Edimax ES-5160G V2 user manual

Edimax

Edimax ES-5160G V2 user manual

IDK MSD-701UHD Command reference guide

IDK

IDK MSD-701UHD Command reference guide

Steren SWI-005 instruction manual

Steren

Steren SWI-005 instruction manual

Vimar Arke Series Quick start manual

Vimar

Vimar Arke Series Quick start manual

HP FlexNetwork 7500 Series Configuration guide

HP

HP FlexNetwork 7500 Series Configuration guide

QCT QuantaMesh T4000 Series installation guide

QCT

QCT QuantaMesh T4000 Series installation guide

Leuze electronic ESB200 Series Original operating instructions

Leuze electronic

Leuze electronic ESB200 Series Original operating instructions

NETGEAR GSM7248 - ProSafe Switch brochure

NETGEAR

NETGEAR GSM7248 - ProSafe Switch brochure

SilverStone EP03 manual

SilverStone

SilverStone EP03 manual

Weil-McLain SlimFit 383-600-513 manual

Weil-McLain

Weil-McLain SlimFit 383-600-513 manual

EtherWAN EX78000 Series installation guide

EtherWAN

EtherWAN EX78000 Series installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.