WorldWEIGH C 100 User manual

C100 Counting Scale
Owners Manual
V2.40


CONTENTS
1. SPECIFICATIONS……………………………………………………………..1
2. PRECAUTIONS………………………………………………………………..2
3. INSTALLATION……...…………..…………………….……………………..…3
Remote Scale Setup………………………..…………………………4
4. KEYS AND FUNCTIONS…………….………………………………………5
Key board………………………………...................................................5
Display………………………………………………………………………6
5. OPERATION………………………………………………………….…………7
Power On/Off…………………….…………………………………………7
Switch to local / Remote Scale….…....………………………………….7
Zero……………………………….…………………………………………7
Tare………………………………………………………………………….7
Accumulation………………………………….………………………….8
Manual Accumulation……………………………………………………..8
Saved Data…………………………………………………………………9
Delete Data…………………………………………………………………9
Automatic Accumulation………………………………………………….9
Parts Counting………………………………………………………..…..9
Weighing a sample to determine the Unit Weight…………………….. 10
Enter a known Weight……………………………………………………..10
Automatic update of Unit Weight…………………………………………10
Check weighing of count pre-set…………………………………………11
Setting the checking limits………………………………………………..11
PLU (Product Look Up)………………………………………………….11
Storing PLU………………………………………………………………...12
Entering Description manually……………………………………………13
Recalling PLU……………………………………………………………...13
6. PARAMETERS…………………………………………………………………14
Keys into the parameter…………………………………………………..14
Parameter settings………………………………………………………...15
7. RS-232 OUT PUT………………………………………………………………16
8. ERROR CODES………………….…………………………………………...17
9. DRAWING……………………...……………………………………………...18
Pa r ts L ist…… …… … ……… … …… … … …… … ……… … …… .19

C100 Series Owners Manual
- 1 -
1. SPECIFICATIONS
DIMENSIONS
Specification
MODEL
C100/6
C100/12
C100/30
C100/60
Part Number 899-300000 899-300001 899-300002 899-300003
Maximum
Capacity
6 lb
12 lb
30 lb
60 lb
3 kg
6
kg
15
kg
30
kg
Readability
.0001 lb
.0002 lb
.0005 lb
.001 lb
.00005
kg
.0001 kg
.0002 kg
.0005
kg
Units of
Measure
lb, kg
Interface
Bi
-
directional RS
-
232 Interface
Stabilization Time
2 Seconds
Operating Temperature
(
32°F
-
104°F
)
Power supply
AC Adaptor 9 V/800 mA / Battery 6V4AH
Calibration
Automatic external
Display
3 x 6
digits LCD digital display with white LED back light
Housing Indicator
ABS Plastic, Stainless Steel p
an
P
latter
size
8.9 x 11.8”
Overall dimensions
12.6 x 13.4 x 4.9”
Net weight
9.5lb
Internal Resolution
Up to
60000

C100 Series Owners Manual
- 2 -
2. PRECAUTIONS
Read this manual before operating or servicing this
equipment.
Follow these instructions carefully.
Disconnect this equipment from the power source
before cleaning of performing maintenance.
Keep the manual for your future reference.
Avoid extremes of temperature. Do not place in
direct sunlight or near air conditioning vents.
Avoid unsuitable tables. The table or floor must be
rigid and not vibrate. Do not place near vibrating
machinery.
Avoid unstable power sources. Do not use near
large users of electricity such as welding equipment
or large motors.
Avoid high humidity that might cause condensation.
Avoid direct contact with water. Do not spray or
immerse the scales in water.
Avoid air movement such as from fans or opening doors. Do not place
near open windows.
Do not stack material on the scales when they are not in use.
Keep the scales clean.

C100 Series Owners Manual
- 3 -
3. INSTALLATION
Unpacking
Carefully take the C100 out of its packaging, making it sure its not damaged and
all accessories are included.
If equipped, remove the shipping safety screw. Indicated by the red label on the
bottom of the C100
Accessories,
1. C100
2. Power Adaptor
3. Stainless steel pan
4. 18’ pre-made remote base cable
5. Product manual
6. User Manual
Keep the packaging material for your future use.

C100 Series Owners Manual
- 4 -
SETUP
Local Scale:
Note: Battery should be charged for 12 hours prior to first use.
Place the scale on a table.
Place the platform in the locating holes on the top cover.
Do not press with excessive force as this could damage the load cell
inside.
Check the water mark. If, bubble is not centered adjust the leveling feet
until centered. Check the level when you change the location.
Attach the power supply cable to the connector on the bottom right side of
the scale base. Plug in the power supply.
Turn on the Scale. The power switch is located at the right side of the
scale base.
The scale will show the model number in the “Weight” display and will be
start self test countdown.
Remote Scale:
The C100 Series can be connected remote base through the Remote
scale port on the left side of the scale case.
Place the remote scale platform in the position where it is to be used.
Level the scale by adjusting the four feet. Making sure it is level.
Press key to change between remote base and local base.

C100 Series Owners Manual
- 5 -
4. KEYS AND FUNCTION
Key Board
Keys
Press this key to
to
Numeric Keys. To enter either individual unit weights or
preset tare
Clear incorrect entries and error conditions
Decimal Point.
Returns the display to zero.
Enter to clear tare weights, Storing the current weight as
tare value. Subtracting the tare value from the total weight
and displays the result as a net weight.
Manually enter the weight of sample, also changes the unit
from lb to kg if they are enabled.
To enter the numbers of items, used as the sample unit
weight.
Add the current count data aggregated. Also Clear the
memory if pressed when balance empty. Can add up to 99
values, or until it reaches the maximum displayable digits
Enter to store and recall the PLU (piece look up)
To set the upper limit of the number of items counted and
back light setting.
To select the local or remote scale.

C100 Series Owners Manual
- 6 -
Display
The arrow “▼” above the symbols
Weight Display
Low Battery
Net
Net Weight Display
ed
Stable
Stable Display
ed
Zero
Zeroing Display
ed
Lb / kg
Current Weighing Mode
Unit Weight Display
Smpl
# of sample
is very low
U.Wt Unit weight is below the minimum
weight
M+
Data entered into the memory
Local /
Remote
Active Scale in use
Count Display
CkPcs
Active in Counting Mode
Wt
Active in Weighing Mode
High
Check Result above the high limit
OK
Check Result with in the limit
Low
Check Result belo
w the low limit
Charge
Status of the battery charging

C100 Series Owners Manual
- 7 -
5. OPERATION
Initial Start-up
Please allow 15 minutes of warm-up time to weight value to stabilizes after
switching on.
1. Power ON/OFF
Power switch is located below the bottom right side of the scale. Switch on
the scale by pressing on/off. The display is switched on and the self test is
started.
If you want to switch off press in the switch in the opposite direction.
2. Switch to Local / Remote Scale
By pressing the display changes from one scale to other scale.
In Local Scale
In Remote Scale
The basic weighing functions are same for both the scales local or
remote.
The number of weighing divisions may be less on the remote scale
dependant on the total capacity of the load cell/s used.
3. Zero
To zero the scale at any time press the key
4. Tare
The weight of any container can be tared by pressing the button so
that with subsequent weighings the net weight of the object being weighed
is always displayed.
Load container to be tared on the pan.
Press the key. Zero is displayed, and tare is subtracted.
Remove weight from the platform. Tared weight is displayed. Only
one tare value can be set. It can be displayed with a minus value.
Once tare is stored, Pressing the key, will clear the tare weight
and Zero the display.
change
Local
change
remote

C100 Series Owners Manual
- 8 -
Entering a tare value using by numeric keys.
This method allows you to enter a value for the tare weight from the
keypad. This is useful if all containers are the same or if the container is
already full but the net weight is required and the weight of the container is
known.
Ensure the display is zeroed.
Enter the known tare weight by using numeric keypad.
Press to enter, weight will be stored as tare weight and
displayed with minus sign and net indicator.
Place the container on the platform, net weight will be displayed.
The tare will be rounded up according to the readability of the
balance. For example, if a tare value of 103g is entered into the
60Kg scale with 5g readability, then the display will be shown 105g.
5. Accumulation
The C100 can totalize weight values or count quantities.
Manual Accumulation
The values (weight and count) shown on display can be add to the memory
by pressing key. Set the parameter F1 off – print – au off
Place the goods to be weighed.
Wait few seconds for display stability then press .
The weight display will be show the total weight, the unit weight
display will be show the number of items and count display will be
show the total accumulated count. The values will be displayed 2
seconds.
The scale must return to come zero or negative number before
adding another samples.
More products can be added by pressing . It can add up to 99
entries or until the capacity of the weight display is exceeded.
0
0
0 .5 00
15
1
0 .5 00

C100 Series Owners Manual
- 9 -
Display of Saved Data
To check the total value saved, press key when the display is in
zero. Total weight will be displayed two seconds.
Delete Saved Data
To clear the memory, press the display will be shown saved data.
Press during the display, delete all saved accumulation data.
Automatic Accumulation
Weighing values automatically accumulate total, when the scale is
unloaded and with out pressing a key
Set the parameter F1 off – print – au on
Place the item to be weighed on the platform
Wait few seconds for display stability and a control beep.
Unload the item from the platform, the weighing value is added into
the memory
The scale must return to come zero or negative number before
adding another samples.
99 entries can be stored or until the capacity of the weight display is
exceeded.
6. Parts Counting
In order to do parts counting, it is necessary to know the average weight of
the items to be counted. This can be done either by weighing a known
number of the items and letting the scale determine the average unit
weight or by manually inputting a known unit weight using the keypad.
To count a greater number of parts the average weight per part has to be
determined with a small quantity.
0
1 .5 00
-
1
-
1 .5 00
0
0
0
-
3
-
1 .5 00
0
-
0
-
0 00

C100 Series Owners Manual
- 10 -
The average piece weight can be increased at any time during the counting
process, by entering the displayed number of items and confirming by
pressing .
Weighing a sample to determine the Unit Weight
Reset the balance to zero or tare the empty container if necessary.
Place the known quantity of items on the scale, wait few seconds for
display stable.
Enter the number of quantity by using numeric keys. Exp: 15
Enter the key to confirm. The scale determines the average parts
weight.
As more items are added to the scale, the weight and the count will
increase.
If the scale is not stable, the calculation will not be completed.
If the weight is below zero, “Count” display will show negative count.
Enter a known Unit Weight
If an a known unit weight, it can enter by using the numeric keys.
Enter the value of unit weight by numeric keys.
Press during the unit display flashing.
If in the weight display as “kg” unit is active, the average piece weight
will be displayed in “g”. If as “lb” is active, the average piece weight will
be displayed in “lb”.
Automatic Update of Unit Weight
The scale can automatically update the unit weight, when a sample
less than the initial sample count are added.
A beep will be heard when the value has updated.
By pressing key, can be blocked unit weight and auto update
0
1 .5 00
15
10
1 .5 00
0 .15

C100 Series Owners Manual
- 11 -
Check Weighing or Count Pre-set
Check weighing is a procedure to cause an alarm to sound when the weight
or piece quantity within the a limits. Limits can be set by using numeric keys.
Setting the Checking Limits
Press key, the active mode will be shown
Press key to select counting
Press key, the active high count limit will be shown
Use numeric key to enter desired and if necessary press to clear.
Press key, the active low count limit will be shown
Use numeric key to enter desired and if necessary press to clear.
Press key to return weighing mode.
For check limits, just one limit value can set
If both values are deleted, the check mode is deactivated.
The beep sound will be worked as described in the beep parameter
f1 off , beep
PLU (Product Look Up)
PLU are used to store items. It can store up to 99 PLU numbers.
The data should be entered against a particular PLU before the weighing
process starts, so that the desired PLU’s can be recalled during the weighing
process. The data can be stored and recalled manually.
Pst
net
Pst
cnt
Hi cmt
1 500
lo cmt
500

C100 Series Owners Manual
- 12 -
Storing PLU
Press key to ensure display zero.
Tare and unit weight to be stored can be either taken from a weighing in
process or by enter manually.
Press display will be shown
Press numeric key exp. 27
Press
Currently stored text will appear
The first digit is flashing, it can
Change by using numeric keys
If necessary, delete additional text
By pressing
Continue to enter text until description is
complete (max: 12 characters)
Use key, number selection to left.
Use key, number selection to right.
Press and hold two seconds key, space to right.
Tare values can be saved (default >2% of capacity)
P lu
-
-
P lu
27
P lu 27
Apple
P lu 27
-
P lu 27
abcdefg
hijklmn

C100 Series Owners Manual
- 13 -
Entering Description Manually
To set the description, press the numeric button and keep it pressed until the
desired letter is displayed. The characters are according to key board.
1 - / \
2 A B C
3 D E F
4 G H I
5 J K L
6 M N O
7 P Q R S
8 T U V
9 W X Y Z
0 _ [ ] _ (space)
Note that this method is only used where alpha-numeric data is permitted. This is
used for the Description field and the User ID number, Scale ID number in the
parameters section.
Recalling PLU
To recall the PLU values the user should first select either local or remote scale
the tare value stored will be specific to the scale selected.
Press display will be shown
Press numeric key exp 27
Press
P lu
-
-
P lu
27
P lu 27
Abcdefg
hijkllm

C100 Series Owners Manual
- 14 -
6. PARAMETERS
To enter into the Parameter
Turn on the scale, press during that start up.
Display will be show
Select the Menu Block
Press key, it can choose menu block one by one.
Enter the Selected Menu
Press key, to confirm what the displays shows.
Select the Sub- Menu
Press key, it can choose the sub-menu block one by one.
Return to Weighing Mode
Press key, to escape from the menu and exit to weighing mode.
F1 off

C100 Series Owners Manual
- 15 -
Parameter Setting
Menu
Sub Menu
Description
Fi off
Beep
Beep off
Beeper is turned off
Beep On in
Beeper is turned on, will be
sounded when in check weighing
limit
s
Beep On out
Beeper will be sounded above the
check weighing limits
El
Lite aut
Backlight will be turn on
automatically, when loaded or a
key is pressed
Lite off
Backlight is turned off
Lite on
Back light is turned on
unit
Kg / lb Weighing Unit kg and lb are
enable
Kilo
Weighing Unit kg only
lb
Weighing Unit lb only
Off
0
Auto off function disable
3
Scale will
turn
off
after 3
minutes
5
Scale will
turn
off
after 5
minutes
15
Scale will
turn
off
after 15
minutes
3 0
S
cale will
turn
off
after 30
minutes
F2 prt
P mode
Print
Au on
Data out put / accumulation after
unloading the balance
Au off
Data out put / accumulation after
by pressing
P cont
RS 232 data output continuously
Ser re
RS 232 data output weight
only
P baud
B 600
Set the required baud
B 1200
B 2400
B 4800
B 9600
parity
8 n 1
8 bits, no parity
7 e 1
7 bits, even parity
7 o 1
7 bits, no parity
P type
Tpup
Standard printer setting
Lp50
Label Printer
U id
U id
abcdef
Shows the current User ID (max 6
characters)
Sc id
Sc id abcdef
Shows the current Scale ID (max 6
characters)
Tech
Technical parameter password
protected

C100 Series Owners Manual
- 16 -
7. RS-232 OUTPUT
The C100 Series of scales come standard with an RS-232 output.
Specifications:
RS-232 output of weighing data
ASCII code
9600 Baud
8 data bits
No Parity
Connector: 9 pin socket
From C100
Pin 2 Output
Pin 3 Input
Pin 5 Signal Ground
To LP50
Pin 2 Input
Pin 3 Output
Pin 5 Signal Ground
Connection to the LP 50 printer
Set Parameter F2 to 9600 8n1 LP50
Set LP50 Dip SW 1,2, and 4 ON
Sample Print
LOCAL SCALE
ID: 123ABC
NAME:Text
12.456 kg NET
1.1234 g U.W.
11 PCS
TOTAL
- - - - - - - - - - - -
49.824 kg TW
44 TPC
4 No.

C100 Series Owners Manual
- 17 -
8. ERROR CODES
Error Message
Description
Solution
-----
Maximum load exceeded
Unload or reduce weight
Err
4
Zero setting error Zero setting range exceeded due
to switching on.(4%max)
Make sure platform empty.
Err 5
Key board error
Check the keys and connecter.
Err 6
A/D value out of range Make sure platform empty and
check the pan is installed proper.
Check
the load cell connectors.
Err 9
Unstable Reading Check any air variation, vibration,
RF noise and touching some
where.
Check the load cell and
connecters.
Err 17
Tare out of range Remove the load and restart
scale again.
--
ol
--
Over range Remove the load.
Re calibrate
Fai l h /
fai l l
Calibration Error Re calibrate
Err p
Printer error
Check the printer and settings
Ba lo /
lo ba
Battery low Re charge battery, check the
voltages.
Other manuals for C 100
1
This manual suits for next models
4
Table of contents
Other WorldWEIGH Scale manuals