WRT IZM-801CS4 User manual

IPsystem gate station installation manual
IZM-801CS4
R
Type:B/B,I
Thank you for choosing WRT. Please read this manual before
using. WRT reserves the right to change specifications or designs
described in this manual without notice and obligation.

Content
Content
1.0 Features& Functions
2.0 Equipment Description
Gate Station
3.0 Caution
4.0 Installation
5.0 Operation
6.0 Specification
7.0 Terminal Description
8.0 Trouble Shooting
9.0 Wiring
1
2
2
3
4~5
~6 22
23
24
25
26~28

Features & Functions
Features Functions &
801 intercom systems is composed by building gate station, user door phone, PC and other
equipments, which is based on TCP/IP. The system is with the technology of multichannel, every
channel can work independently.
1.Luxury design, Max. capacity 400,000 cards,500,000 door phones.
2.Color video.
3.4.0"LCD Display
4.Digital audio video coding.
5.Multichannel,Guard Center can call other spare door phones while Gate Station are
talking with door phone.
6.Divert,No-Disturb,multi-monitors and multi-centers,choose center automatically
7.Can call & talk with Guard Center which can remote unlock.
8.Unlock by password or cards , disarm by cards
9. function(optional)Snapshot 。
10.Burglar alarm(optional);
D 11.oor contact alarm;
12.Lift call function(optional);
13.CCD with night infrared compensation;
14.TCP/IP Agreement, network, remote system upgrade
1

Equipment discription
Gate Station
2
1.Microphone 2.LCD Display 3.Keypad 4.Speaker 5.Camera with IR compensation
6.IC card induction zone 7.Camera adjustment 8.Socket for lift control or access control
9.Lightning terminal(GND) 10.Socket for power input+unlock signal output
11.To network switch connector
12.Socket for door contact and door release.
Front View Back View
2
1
5
6
3
4
7
8
12
9GND
11
10
18V GND
MENCI
DOOR
GND UNLOCK
B
A
J13
J15
J21
J24
J20
J22
EARTH-GND

3
Caution
Caution
1.Avoid direct sunlight, extreme temperature, frost, chemical erosion or dust.
2.Please confirm the height to install the station so that the visitor is within the vision of the camera.
3.Cut off the power when installing the system.
4.Make sure the wall or surface where the station installed is installed is flat so as to avoid dust or water.
5.System wire should adopt CAT 5.
6.Sperate strong electricity from the weak.Keep away from the elevator and TV cables (over 50m). Use
iron tube and do not use the same wire tube for strong and weak electricity. The ends of the iron tube
should be buried in 3m deep down the ground so as to raise capability of anti-jamming and lighting.
7.There is an - EARTH-GND socket on the back of gate station, it is lightening terminal, should be earthing
(any one is ok) so as to avoid undesirable effects.
8.In order to avoid interference, it is better to use wire tube and separate other interferences. For easy
maintenance and stability,all wire ends should not be installed in the wire tube or place where is humid.
9.Turn on the power supply after installing the whole system well.
10.Keep IC card be water-resistant, antimagnetic,antifluting.
11.Keep the IC induction zone clean,in order to enhance reliability to identify information.
12.For the first usage, access control data in the Door Station should be cleared to initialize the memorizer.
13.If the system is found of any malfunction, please cut off the power and inspect according to the Trouble
Shooting . If it is unable to find the causes , please contact the sales agent or the manufacturer's
after-sales service department.Do not repair or replace the parts by yourself,otherwise the system may
be damaged.

4
Installation
Flush mounting
Iron gate
(1) (2)
(3) (4)
135.0mm
351.0mm
Wire tube
Bottom
case
363.0mm
380.0mm
φ3.5
125.0mm
96. 5 mm
1. Drill holes at the suitable place on the front and the back of the door according to the size
(Figure 1).
2.Unscrew 4 screws from Gate Station.(Figure 2) .
Drill a wire hole at the bottom case, insert the transmission wires through the wiring hole, 3.
Connecting all wires and press the Gate Station from the front of the door. Fix the bottom case
with screws.
4.Fix Gate Station with screws.

5
Installation
Flush mounting
1. x x mm .Make a hole in the wall prefer to the dimension of 135 380 67 The bottom of the hole
shall be 150cm to 155cm above the ground.
Make a wiring hole on the bottom case and insert the wires through it, install the bottom case 2.
into the wall and embed it in the cement.
3. 。Unscrew 4 screws from Gate Station and separate aluminium sheet
4. , Connecting all Gate Station wires then fix Gate Station on the bottom cover.
5. Fix the aluminium sheet with screws.
Wall
(1) (2)
(3) (4)
135mm
380mm
Wire tube
67. 0 mm
Wall
Bottom
case

6
Operation
Operation
Please note:
1.All the parameters should be configured by appointed or authorized person in case of any data
leakage. Admin password must be kept by specially-assigned person for usage or updating
purpose.
2.Access control settings of gate station and wall station in the network system should be
operated in center guard unit.
3.Back up a copied data file in case of any damage of computer system.
4.Every twice press the button not more than 30s, or it will exit operating state.
When standby, the screen will show:
The Gate Station works after all parameters are correct. Press"*"first,then press “#”,and
release the two keys at the same time,The screen will show:
Input 1-8 digits managing PIN setting last time(If it is first time to input,it should be input the original
PIN”88888888") and press “*”.If press correct, it will be setup state:
Pleas e input password
Input room ID “#”
for c a ll
“00#” for center
INPUT ROOM ID

7
Operation
Operation
Press“#”to enter next page:
User press number keys before the items to enter the related interface of parameter configuration .
System info: Check the network parameter and other information.
Press“0”on the basic setting menu, the screen will show:
Press“0”to check next page, press“*”to return.
Network setting: Configure or modify the local network parameter.
Press “1” on the basic setting menu, the screen shows:
1SN:
2MAC:
3VER:
4Device ID:
5Local IP:
6Subnet mask:
7Gateway:
Press” to return.Press to next page*" "# "
0 System info 5 Password setting
1 Network setting 6 Function ON/OFF
2 Device No. 7 Time setting
3 Dial Format 8 Access control
4 Device type 9 Language
1 Restore factory setting
2 Restart
3 Return
“0" Next page
2 00 10. .
00.00.00.00.00.00
Ba0000000115
010010100000001
192 168 100 039...
255 255 255 000...
192 168 100 001...
1 Restore factory setting
2 Restart
3 Volume setting
4 Delay setting
5 Room format
6 Return

8
Press number key, it can clear up the data in the related input box and input network parameters
according to actual distribution. After finished input the data each time, if the data is legal, the
screen will prompt that modify successfully and activate the next input box automatically. when
non-input status, press ”8” or”*”to return to previous menu or exit automatically after 60 seconds.
Note: Network setting must be conducted by prefessional person.Other people can not setting or
modify to avoid damaging the Gate Station.
If there are no backup Center IP,back up Master Station etc.,other IP address no need to input.
Press”*”to clear up the data in the input box or exit input status.
Device NO.:
Press”2” on the basic setting menu, the screen shows:
Press number keys,it can clear up the data in the related input box and input network parameters
according to actual distribution. After finished input the data each time, press”#” to confirm, the
screen will prompt that modify successfully and activate the next input box automatically. when Operation
Operation
1 Local IP
2 Subnet mask
3 Gateway
4 Center IP
5 Back up center
6 Master Station
7 Sub Master Station
8 Return
192 168 100 001. . .
192 168 100 005. . .
192 168 100 001. . .
255 255 255 000. . .
000 000 000 000. . .
000 000 000 000. . .
192 168 100 005. . .
1 Group NO.
2 Building NO.
3 Unit NO.
4 Local NO.
5 Return
01
01
01
001

9
input the parameters, the interface will request to select digit or alphabet(except “0"),for example,
”1:1 2:A”.Press”1" to select serial number as digit, press”2" to select serial number as alphabet.
When non-input status, press ”5” ” ” or to return to previous menu or exit automatically after 30s*
Note:Gate Station NO.is composed of 2 digits group NO.+3 digits building NO.+2 digits unit NO.+2
digits local NO.,When input should be based on this principle,if digits are not enough ,it
could add ”0" in front.
Press”*”to clear up the data in the input box or exit input status.
Dial Format:
Press”3 on the basic setting menu, the screen shows:”
Room NO, of tenant adopt 13-digit encode(2-digit group NO. + 3-digit building NO. + 2-digit unit
NO. + 3-digit floor NO. + 3-digit room NO.).For example, group NO . digit is 0,building NO. digit is
0,unit NO. digit is 0,floor NO. digit is 1,room NO. digit is 1,when Gate Station calls floor 1 room 1,
input “11#”can call this tenant. If floor NO. digit is 2,input”011#”.
Press number keys,it can clear up the data in the related input box and input network parameters
according to actual distribution. After finished input the data each time, if the data is legal, the
Operation
Operation
Room NO .
1 Group NO. digit
2 Building NO.digit
3 Unit NO.digit
4 Floor NO.digit
5 Room NO.digit
6 Return
1
1
1
1
1

screen will prompt that modify successfully and activate the next input box automatically.
Non-input status,press”6" or “*” can return to previous menu or exit automatically after 30s.
Note: Press”*”to clear up the data in the input box or exit input status.
Device type
Press “4" on the basic setting menu, the screen shows:
Press the device you want(” ” means selected),press” to confirm,the screen will prompt modify√#"
successfully.Press”*” to return to previous menu.
Password setting set local super password and unlock password.:
Press”5” on the basic setting menu, the screen will show:
Room NO.
Room NO.
Operation
1 Entrance Station
2 Main Gate Station √
3 Sub-Gate Station
4 Return
10
Operation
1 Modify super password
2 Modify unlock password
3 Modify special password
4Return

11
a.Modify super password
Input 1-8 digits new password .Then the screen prompt to confirm super password again. If
entered two new super passwords are the same,it will prompt that new super password is modified
successfully.
Note: Original password is ”88888888”
Must use new password when enter setting menu.
b.Modify unlock password
Press”2" on password setting interface to the menu:
Please input new password
Operation
Operation
Please input new password

12
Operation
Operation
6- digit room NO.
Please input room NO.
Input 6 digits new password.Then the screen prompt to confirm unlock password again. If entered
two new unlock passwords are the same,it will prompt that new unlock password is modified
successfully.
Note: Original password is ” ”,new password is 6-digit.00000000
c.Modify special password
Press”3" on password setting interface to the menu:
Input room NO.(Former 3-digit is floor NO.,last 3-digit is room NO.),press”#”to confirm ,the
screen shows:
Input 6 digits new password, press”#” to confirm.Then the screen prompt to confirm special
password again,tenant input new password again,press”#” to confirm. If entered two new special
passwords are the same,it will prompt that new special password is modified successfully.
Note:New password is 6-digit.
6- digit room NO.
Please input new password

13
Function ON/OFF
Press 6 ” ” on the basic setting menu, the screen will show:
Snapshot ON/OFF: If this function enabled on Gate Station and Guard Center,when door phone call
other tenant or Guard Center,Guard Center will snap a picture.
Lift ON/OFF: When system is connecting with lift,press”1" to activate lift control.Thus,when tenant
unlock for Gate Station,lift will go to the place where Gate Station is.
Key tone ON/OFF: When key tone is on,each time press the key ,“Di” can be heard.
Disarm by card: When disarm by card is on,the tenant swipe the card to unlock and disarm door phone.
Recording ON/OFF: When this function enabled on IP door phone and Gate Station, Gate Station can
leave message for the tenant.
Magnetic alarm: When Gate Station is connecting with door contact, enable magnetic alarm is sug-
gested.Thus,if door release exceed delay time of door contact and not close the door,it will report
the alarm to Guard Center.
Press number keys to clear up the data in the input box.Input ”0” or ”1” to set, press”#” to confirm,the
screen will prompt that modify successfully and activate the next input box automatically.
Press”*” to exit input status.
or to return to previous menu or exit automatically after 30s.Non-input status,press ”7” ” ” *
Operation
Operation
1 Snapshot ON/OFF
2 Lift ON/OFF
3 Key tone ON/OFF
4 Disarm by card
5 Recording ON/OFF
6 Magnetic alarm
7 Return
1
0
0
0
1
0
0 OFF 1 ON

14
Time setting: Set the time of Gate Station.
Press”7” on the basic setting menu interface,the screen will show:
Press number keys to clear up the data in the input box, input the date and time,press “#” to confirm
after finished ,the screen will prompt modified successfully, it means the group data set
successfully.
Under non-input state, press”3”or”*”to return previous or exit automatically after 30s.
Access control: It is effective for Gate Station with access control,including”issue card by
room NO.”,”issue card by swiping”,”delete card by room NO.”and”delete card by swiping”.
1 Issue card by swiping
2 Delete card by swiping
3 Issue card by room NO.
4 Delete card by room NO.
5 Return
1Input Year/Month/Day
2 / /Input Hour Min Sec
3Return
2011/01/01
08:00:00
Operation
Operation

15
a Issue card by swiping Issue card by swiping for tenants.. :
On the “Access Control“interface press “1“ the screen will show:, ,
Swipe the card at the induction zone according to the prompt , the screen prompts modified
successfully,it means the card issued successfully,the user could continue to swipe other cards.
Press “ “to return to previous menu.*
b Delete card by swiping Delete card by swiping for tenants.. :
Press “2" on the “Access Control”interface,the screen will show:
Swipe the card at the induction zone according to the prompt ,the screen prompts modified
successfully,it means the card deleted successfully,the user could continue deleting other cards.
Press to return to previous menu“*” .
. .: .c Issue card by room NO Issue card by room NO of the tenant.
Press “3" on the “Access Control”interface,the screen will show:
1 Issue card by swiping
2 Delete card by swiping
3 Issue card by room NO.
4 Delete card by room NO.
5 Return
Please swipe card. . . . . .
1 Issue card by swiping
2 Delete card by swiping
3 Issue card by room NO.
4 Delete card by room NO.
5 Return
Please swipe card. . . . . .
Operation
Operation

16
Input 6 digits (3-digit floor NO.+ 3-digit room NO.,for example 001001) the room NO.of tenant.
Press”#”again,then swipe the card at induction zone,it means issued successfully,the user could
continue inputting other room NO. to issue other cards.Press“*”to return to previous menu.
d Delete card by room NO Delete card by room NO. of the tenant.. .:
Press “4" on the “Access Control”interface,the screen will show:
Input 6 digits( for example 001001) the room NO.of tenant3-digit floor NO.+ 3-digit room NO., .
Then press”#”to confirm,it means deleted successfully.
Note:The tenant could use the card which is issued successfully to unlock.
The card which is deleted will become invaildly,can not open the electric lock,until the card
is registered again.
Language:
There are two languages for option: English and Chinese.
1 Issue card by swiping
2 Delete card by swiping
3 Issue card by room NO.
4 Delete card by room NO.
5 Return
1 Issue card by swiping
2 Delete card by swiping
3 Issue card by room NO.
4 Delete card by room NO.
5 Return
Operation
Operation

17
Restore factory setting: All the settings are initialized, please be cautious!
Press 1 on the basic setting menu on page 2,the screen will show:” ”
Press 1 then press #all the settings are initialized,Gate Station will restart automatically.” ”, ” ”,
Restart
Press 2 on the basic setting menu on page 2,the screen will show:” ”
Press 1 then press #Gate Station will restart automatically.” ”, ” ”,
Volume setting
Press 3 on the basic setting menu on page 2,the screen will show:” ”
0:NO 1:YES
Restore factory setting?
0:NO 1:YES
Restart?
Operation
Operation
(0-9)
1 Ring volume
2 Talk volume
3 Return
5
5

Press number keys to clear up the data in the input box.Input ”0-9” to set, press”#” to confirm,the
screen will prompt that modify successfully and activate the next input box automatically.
Press”*” to exit input status.
or to return to previous menu or exit automatically after 30s.Non-input status,press ”3” ” ” *
Delay setting
Press 4 on the basic setting menu on page 2,the screen will show:” ”
Press “1" to clear up the data in the input box.Input delay time(Max. 300), press”#” to confirm,the
screen will prompt that modify successfully.
Press”*” to exit input status.
or to return to previous menu or exit automatically after 30s.Non-input status,press ”2” ” ” *
Room format
” ”Press 5 on the basic setting menu on page 2,the screen will show:
Operation
18
Operation
1 Magnetic delay(S)
2 Return
120
1 Group
2 Building
3 Unit
4 Floor
5 Room
6 Return
0
0
0
0
0
0:Digit
1:Alphabet
Table of contents
Other WRT Intercom System manuals