1
Standalone Biometric Reader
EN
DINB100SA v2
USER’S MANUAL
v. c3

www.xprgroup.com
2
1. INTRODUCTION
2. MOUNTING
3. SPECIFICATIONS
4. APPLICATION DIAGRAM
5. RECOMMENDED SWIPING TECHNIQUE
6. INDICATION
7. WIRING
8. ADDING ADMIN FINGER
9. PAIRING BIOMETRIC READER AND REMOTE RELAY UNIT
Pairing dinb100-sa with dinrtt
Pairing dinb100-sa with rtt
Pairing dinb100-sa with ru2
10. ADMINISTRATOR PROGRAMMING
Add inger relay 1
Add inger relay 2
Add inger relay 1&2
Delete inger
Delete all ingers
Change admin inger
Change installer inger
Administrator programming block diagram
11. INSTALLER PROGRAMMING
Set relay 1 time
Set relay 2 time
Buzzer on/o
Backlight on/o
Installer programming block diagram
12. ADMINISTRATOR PROGRAMMING BY KEYPAD
13. INSTALLER PROGRAMMING BY KEYPAD
3
3
4
4
4
4
5
5
6
6
6
6
7
7
7
7
7
8
8
8
9
10
10
10
10
10
11
12
14
CONTENS

www.xprgroup.com
3
1. INTRODUCTION
MAINTENANCE
WARNING!
2. MOUNTING
RECOMMENDATIONS
NOTES
DINB100SA v2 is access control ingerprint reader designed for easy management of the users and coniguration. The
scanner is made with advanced capacitive sensing technology that provides some advantages over optical solutions like:
- making almost impossible to make fake copy of the users ingers
- same performance in the dierent light conditions
- good reading of ingers with stains from daily jobs
Built in strong scanning and matching algorithm provides excellent tolerance in the way inger is swiped over the sensor
reducing to minimum the need to repeat inger swiping at the sensor.
The reader can store up to 100 inger templates. One template is reserved for User manager (Administrator), one
template is reserved for Reader coniguration (Installer) and up to 98 templates are for Users.
No special or periodic maintenance is required. If cleaning is needed, use soft wet cloth and wipe gently the dirt. Do not use
chemicals and materials that can scratch the sensor.
Do not touch the sensor with other objects than inger. Do not pour or splash with water or other liquids. When painting or
construction work is ongoing in the area around the reader, protect the reader sensor area from possible damages and paint.
If reader is to be dismounted or relocated, call authorized installer for the job. Disposal of this product must be handled
according to all national laws and regulations.
Consult with installer about safety level of the installation. There are devices with relays compatible with this reader that can
increase the security of the system if needed. One or two enrolled ingers are enough for one user. Ask the installer before he
leaves the site to enroll your inger as administrator.
The Reader is using physical roughness of the ingerprint to scan the inger. Some of the users may have very lat ingertips,
making diicult for the sensor to recognize correctly the ingerprint. In most cases, these are children and older persons. To
solve this problem, do the following:
1. Try with dierent user’s ingers to ind the “best” inger.
2. Check with the installer other models of the reader with added card reader or keypad for other type of access.
Do not install the device and cabling close to a source of strong electro-magnetic ields like radio-transmitting antenna.
Do not place the device near or above heating equipments.
If cleaning, do not spray or splash water or other cleaning liquids but wipe it out with smooth cloth or towel.
Do not let children touch the device without supervision.
Note that if the sensor is cleaned by detergent, benzene or thinner, the surface will be damaged and the ingerprint can’t be entered.
The operating temperature of the product is between -20ºC - + 50ºC. If the reader is installed in an environment where the
temperature can drop below -10ºC or/and if the sensor could only be exposed to direct sunlight, it is strongly recommended
to install the reader inside a third party sealed wall mount box (itted with additional heater if very low temperature) to keep
a constant sensor level performance. XPR™ cannot guarantee the functionality of the product if measures and advice before
are not followed.
It is also strongly recommended to use double technology biometric readers when use outdoor to oer irst higher security
but also the possibility to use dierent readers depending on users.

www.xprgroup.com
4
4. APPLICATION DIAGRAM
6. INDICATION
3. SPECIFICATIONS
5. RECOMMENDED SWIPING TECHNIQUE
Fingerprint Capacity:
Output:
Push Button Input:
Door Open Time:
Entry Mode:
Programming:
Admin/Installer Fingers:
Backlight ON/OFF:
Buzzer ON/OFF:
Firmware upgrade:
Current Consumption:
Power Supply:
Indication:
IP Factor:
Storage/Operating Temperature :
Storage/Operating Humidity:
Dimensions(mm):
98 templates
1 x Relay (2 A /24V AC/DC)
Yes
Pulse (1 to 30 seconds) or Toggle(ON/OFF)
Finger (basic installation)
Finger or Card (when used with card reader DIN Card reader)
Finger or PIN code (when used with keypad DINPADM)
By swiping
1 Administrator and 1 Installer Finger
Yes
Yes
via RS485 converter and windows application
100 mA max.
914 V DC
Tricolor Status LED
IP40
-20°C to +50°C
5% to 93% RH without condensation
80 x 80 x 9
DINB100-SA v2
Follow the below instructions for correct inger swiping. Starting from the irst inger joint,
place the selected inger on the swipe sensor and move it evenly towards oneself in one
steady movement.
Result:
For a valid swipe: Tricolour Status LED turns green + OK Beep(short + long beep)
For an invalid or misread swipe: Tricolour Status LED turns red + Error Beep ( 3 short beeps)
Tricolor Status LED
Green - Access Granted
Red - Access denied
Orange - Idle Mode
OK Beep - short + long beep
Error Beep - 3 short beeps
Swipe Finger - 2 short beeps

www.xprgroup.com
5
7. WIRING
8. ADDING ADMIN FINGER
1. Close the jumper on the back of the device.
2. Reset the Power of the device.
3. Wait for One long + multiple short beeps
4. Open the jumper. (short beeps will stop)
5. Wait for about 15 seconds for the LED to blink in Orange.
6. Swipe the Master inger min.6 times. (Until Ok Beep)
Warning: This procedure also deletes all the users and the installer inger.
Warning: This procedure will unpair the connected relay unit (RTT, DINRTT or RU2)
NC
C
NO
12V
GND
B
PB
A
GND
tamp
tamp
Relay Output
1N4007
Electric Door Strike
(DC powered)
+
-
Jumper (Adding Master Finger)
12 VDC
+-
12V
GND
B
PB
A
GND
tamp
tamp
PB
tamp
tamp
C
NO
Alarm
12V
GND
Power Supply
(9-14V DC)
GND
B
+12V
PB
GND
ARs485
Push Button
Tamper
tamp
tamp
NC
C
NO
NC
C
NO
Connection to additional
card reader or keypad
DINB100-SA v2
12/24V AC/DC
12V
GND
B
A
DINB100-SA
x 6

www.xprgroup.com
6
9. PAIRING - BIOMETRIC READER AND REMOTE RELAY UNIT
If secure installation is needed, the reader can be connected to remote relay unit at secured area, which also can play the role of
request-to-exit push button. Follow the instructions bellow to pair(couple) both devices or refer to the Remote Relay’s Manual.
Pairing DINB100-SA with DINRTT
Pairing DINB100-SA with RTT
Pairing DINB100-SA with RU2
1. Close the Jumper. DINRTT beeps continuously and
the red led blinks.
2. Open the Jumper
3. Wait for Beep + OK Beep (short + short + long beep)
After the OK beep, the coupling is done.
1. Put Dipswitch No.1 to position ON. RTT
beeps continuously and the red ledblinks.
2. Put Dipswitch No.1 to position OFF.
3. Wait for Beep + OK Beep (short + short +
long beep)
After the OK beep, the coupling is done.
1. Put the Jumper to closed position. RU2
beeps continuously and the red led blinks.
2. Put the Jumper to open position.
3. Wait for Beep + OK Beep (short + short + long
beep)
After the OK beep, the coupling is done.
Pb2
GND
Pb1
GND
Nc1
COM
No1
Nc2
COM
No2
A
B
Tamp
Tamp
Rs485
GND
+12V
GND
+12V
Exit Button
(NO)
1N4007
+
-
Rs485
AB
12V
GND
B
A
+12V
GND
12 VDC
+
-
12 VDC +
-
DINB100-SA v2 DINRTT
AB
+12V
+12V
GND
GND
GND
Pb1
No1
COM
12
max. 50 meters
Rs485
AB
12V
GND
B
A
+12V
GND
12 VDC
+
-
DINB100-SA
AB
+12V
GND
1N4007
+
-
12 VDC +
-
No
COM
RTT
12
ON
max. 50 meters
12 VDC
+
-
1N4007
+
-
Ru2
Violet
Pink
COMNO
A (RS485)
B (RS485) +12V
GND
GND
+12V
DINB100-SA v2
1
2
max. 50 meters
Warning: Changing the ADMIN inger will also unpair the remote relay unit.

www.xprgroup.com
7
10. ADMINISTRATOR PROGRAMMING
ADD Finger Relay 1 (Finger that will activate relay 1)
ADD Finger Relay 2 (Finger that will activate relay 2)
ADD Finger Relay 1&2 (Finger that will activate relay 1&2)
Use point ingers as Administrator and Installer. You can use the other ingers as access ingers.
Administrator inger is enrolled at the end of the system installation. Initial enrollment of the Admin inger is described in
installer manual.
Action Finger Backlight Buzzer Sound
Swipe Admin Finger 1 time x 1 slow blinking short beep
Wait 5 seconds (until fast blinking) short beep
Swipe User Finger min. 6 times
(until short + long beep) x 6 fast blinking short + long beep
Action Finger Backlight Buzzer Sound
Swipe Admin Finger 2 times x 2 slow blinking short beep
Wait 5 seconds (until fast blinking) short beep
Swipe User Finger min. 6 times
(until short + long beep) x 6 fast blinking short + long beep
Action Finger Backlight Buzzer Sound
Swipe Admin Finger 3 times x 3 slow blinking short beep
Wait 5 seconds (until fast blinking) short beep
Swipe User Finger min. 6 times
(until short + long beep) x 6 fast blinking short + long beep
or
or
or
Present card/tag 1 time x 1 fast blinking short + long beep
Present card/tag 1 time x 1 fast blinking short + long beep
Present card/tag 1 time x 1 fast blinking short + long beep
Relay 2 is available if the reader is used with remote relay unit with 2 relays(DINRTT and RU2). Consult the installer if Relay 2 is available in your system.
Relay 2 is available if the reader is used with remote relay unit with 2 relays(DINRTT and RU2). Consult the installer if Relay 2 is available in your system.

www.xprgroup.com
8
DELETE Finger
DELETE ALL Fingers and Cards
CHANGE ADMIN Finger
CHANGE INSTALLER Finger
Action Finger Backlight Buzzer Sound
Swipe Admin Finger 4 times x 4 slow blinking short beep
Wait 5 seconds (until fast blinking) short beep
Swipe User Finger x1 fast blinking short + long beep
Action Finger Backlight Buzzer Sound
Swipe Admin Finger 4 times x 4 slow blinking short beep
Wait 5 seconds (until fast blinking) slow blinking short beep
Swipe Admin Finger 2 times x2 fast blinking multiple beeps
Action Finger Backlight Buzzer Sound
Swipe Admin Finger 5 times x 5 slow blinking short beep
Wait 5 seconds (until fast blinking) slow blinking short beep
Swipe NEW Admin Finger
min.6 times x6 fast blinking short + long beep
Action Finger Backlight Buzzer Sound
Swipe Admin Finger 6 times x 6 slow blinking short beep
Wait 5 seconds (until fast blinking) slow blinking short + long beep
Swipe NEW Installer Finger
min.6 times x6 fast blinking 3 short beeps
or
Present card/tag 1 time x 1 fast blinking short + long beep
CONNECTING DINB100 WITH DINMTPX PROXIMITY READER
Connect both devices with the cable provided.
The proximity reader will be powered via that
cable. No extra power supply for the proximity
reader is needed. Once connected, no further
settings are needed.

www.xprgroup.com
9
Administrator Programming block diagram
Swipe the ADMIN Finger 1 to 6 times depending of the desired menu
ADD Finger
Relay 1
(on board)
1swipe
ADD Finger
Relay 2
(remote)
ADD Finger
Relay 1&2 DELETE FINGER
Change
ADMIN
Finger
Enroll
INSTALLER
Finger
2swipes 3swipes 4swipes 5swipes 6swipes
Wait
5 seconds
(until fast blinking)
SWIPE
new finger
min. 6 times
or
present
card/tag
SWIPE
already enrolled
finger
1 time
or
present
card/tag
SWIPE
new finger
min. 6 times
or
present
card/tag
SWIPE
new finger
min. 6 times
or
present
card/tag
SWIPE
ADMIN finger
2 times
to
DELETE ALL
SWIPE
new ADMIN
FINGER
min. 6 times
SWIPE
new
INSTALLER
FINGER
min. 6 times
END END END END END END END
Only in combination
with DINRTT and RU2
Wait
5 seconds
(until fast blinking)
Wait
5 seconds
(until fast blinking)
Wait
5 seconds
(until fast blinking)
Wait
5 seconds
(until fast blinking)
Wait
5 seconds
(until fast blinking)
Wait
5 seconds
(until fast blinking)

www.xprgroup.com
10
11. INSTALLER PROGRAMMING
Set Relay 1 Time
Set Relay 2 Time
BUZZER ON/OFF
BACKLIGHT ON/OFF
Action Finger Backlight Buzzer Sound
Swipe Installer Finger 1 time x1 slow blinking short beep
Wait 5 seconds (until fast blinking) short beep
Swipe the INSTALLER Finger
and start counting seconds x1 fast blinking beeps on 1 second
Swipe the INSTALLER Finger
to stop or wait 30 seconds to
put the relay in toggle mode
x1 fast blinking short + long beep
Action Finger Backlight Buzzer Sound
Swipe Installer Finger 2 times x2 slow blinking short beep
Wait 5 seconds (until fast blinking) short beep
Swipe the INSTALLER Finger
and start counting seconds x1 fast blinking beeps on 1 second
Swipe the INSTALLER Finger
to stop or wait 30 seconds to
put the relay in toggle mode
x1 fast blinking short + long beep
Action Finger Backlight Buzzer Sound
Swipe Installer Finger 3 times x3 slow blinking short beep
Wait 5 seconds (until fast blinking) short beep
Swipe Installer Finger x1 fast blinking short + long beep
Action Finger Backlight Buzzer Sound
Swipe Installer Finger 4 times x4 slow blinking short beep
Wait 5 seconds (until fast blinking) short beep
Swipe Installer Finger x1 fast blinking short + long beep
Relay 2 is available if the reader is used with remote relay unit with 2 relays(DINRTT and RU2). Consult the installer if Relay 2 is available in your system.

www.xprgroup.com
11
Installer Programming block diagram
Swipe the Installer Finger 1 to 4 times depending of the desired menu
Set
RELAY 1
Time
(on board)
1swipe
Set
RELAY 2
Time
(remote)
BUZZER
ON/OFF
BACKLIGHT
ON/OFF
2swipes 3swipes 4swipes
Wait
5 seconds
(until fast blinking)
END END END END
Swipe the Installer Finger
and start counting seconds
Swipe the Installer Finger
to put the Buzzer ON/OFF
Swipe the Installer Finger
to stop or wait 30 seconds
to put the relay in toggle
ON/OFF mode
Only in combination
with DINRTT and RU2
Swipe the Installer Finger
and start counting seconds
Swipe the Installer Finger
to stop or wait 30 seconds
to put the relay in toggle
ON/OFF mode
Swipe the Installer Finger
to put the Backlight
ON/OFF
Wait
5 seconds
(until fast blinking)
Wait
5 seconds
(until fast blinking)
Wait
5 seconds
(until fast blinking)

www.xprgroup.com
12
12. ADMINISTRATOR PROGRAMMING BY KEYPAD
Programming by keypad can be done only if the DINB100SA V2 reader is connected to keypad DINPADM as shown
in the pictures bellow. The connection is done by the cable provided with the biometric reader. Once connected,
the keypad must be put in slave mode.
Connect both devices with the cable provided.
Put the keypad in slave mode:
Press B (3 seconds) + 000000
Press 0
Press 2
Press A to exit
Reset the device
Note: In some previous versions of our keypads,
you can enter the menu only by pressing B +
000000. Please refer to the Keypad’s Manual.

www.xprgroup.com
13
ADMINISTRATOR PROGRAMMING BY KEYPAD
Note: Entering this menu is done by
admin PIN Code. You can not enter
with Admin Finger.
Note: The Fingerprint can be
deleted by keypad, only if it is
enrolled with keypad.
Example 1: Add user inger to Relay1 - Press 1234 + A + 1 + 1 + 1 + 01 + A + Enroll inger 6 times. 0A to exit.
Example 2: Add user PIN 147 to Relay2 - Press 1234 + A + 1 + 2 + 2 + 02 + A + 147 + A. 0A to exit.
ENTER ADMIN CODE default: 1234+A
ADD
User
MENU
Press 0A to exit the Menu
Press “A”
DELETE
User
ENROLL
Admin Finger
or PIN Code
ENROLL
Installer Finger
or PIN Code
FINGER
Location
01-97
Press “A”
ENROLL
Finger
Swipe
the finger
min.
6 times
PIN Code
Location
01-97
Press “A”
PRESS
the
PIN Code
1 to 8
digits
Press “A” ENROLL
Finger
Swipe
the finger
min.
6 times
ENROLL
Finger
Swipe
the finger
min.
6 times
PRESS
the
PIN Code
1 to 8
digits
PRESS
the
PIN Code
1 to 8
digits
Press “A”Press “A”
PIN Code
Location
FINGER
Location
12
DELETE
ALL
Users
345
01-97 01-97
ADD
Finger
1
ADD
PIN Code
2
Press “A” Press “A” Press “A” Press “A” Press “A”
DELETE
PIN Code
DELETE
Finger
RELAY 1
(on board)
RELAY 2
(remote)
RELAY
1 & 2
3
CONFIRM ADD
Finger
ADD
PIN Code
ADD
Finger
ADD
PIN Code
7
Press 0A to exit the Menu
Exit
multiple beeps
2222
1111
x 6
x 6
x 6
Press “A”

www.xprgroup.com
14
13. INSTALLER PROGRAMMING BY KEYPAD
Note: Entering this menu is done by
installer PIN Code. You can not enter
with Installer Finger.
Example: Change relay1 time to 2 seconds - 5678 + A + 1 + 02 + A.
ENTER INSTALLER CODE
default: 5678+A
Set Relay 1
TIME
(on board)
MENU
1
Set Relay 2
TIME
(remote)
2
Press 0A to exit the Menu
Press
01 to 30 for
time in seconds
or
00 for toggle
(ON/OFF) Mode
Backlight
ON/OFF
Buzzer
ON/OFF
34
Press
01 to 30 for
time in seconds
or
00 for toggle
(ON/OFF) Mode
0 = OFF
1 = ON
0 = OFF
1 = ON
Press “A” Press “A” Press “A” Press “A”
Press 0A to exit the Menu

www.xprgroup.com
15

www.xprgroup.com
16
This product herewith complies with requirements of EMC directive 2014/30/EU. In addition it complies with
RoHS2 directive EN50581:2012
Table of contents
Other xpr IP Access Controllers manuals