EN Specifications MagFlux®
Display
Enclosure Rating Dust- and waterproof IP 67, NEMA 6 (when
mounted on Converter)
Housing Material Glass-reinforced Polycarbonate
Communication MODBUS® RTU-mode, 9600 baud, 2-wire RS
485, master-mode
Interface RS-485. USB 1,1 type mini B, Female
Memory
345.000 entries with date, time and value
Converter
Measuring Range MagFlux®:
Range = 0-10 m/s MagFlux®Q:
Range = 0-8 m/s
Min. Liquid Conductivity ≥ 5 mS
Digital Outputs One voltage-free electromechanical relay (max.
28 V DC / 300 mA) One optically isolated MOS-
FET relay (max. 28 V AC / V DC / 500 mA)
Digital Inputs One, max. 28 V DC, < 2,5 V DC = 0 (low ), > 10
V DC = 1 (high), pulse length > 100 ms
Analog Output 1 pcs. Active 4 - 20 mA, galvanically isolated,
10 bit resolution, (max. load 600 Ω)
Communication
MODBUS® RTU-mode, 9600 baud,
2-wire RS 485, slave-mode
Interface RS 485 for connection to Display Unit or PLC
Power Supply 24 V AC, 50 / 60 Hz ± 10 % or
115 V AC, 50 / 60 Hz ± 10 % or
230 V AC, 50 / 60 Hz ± 10 %
10-30 V DC
Power consumption max. 10 W
Ingress Protection and Material
Polycarbonate, glass reinforced
IP 67, NEMA 6
Weight 1,0 kg
Approvals UL File E 1940 21
CE approvals EN 61000-6-4 2007-02-19, EN
61000-6-2 2005-09-08
Connection Box
Ingress Protection and Material
IP 68, NEMA 6P (using gel potting kit). Glass-
reinforced Polycarbonate
PL Dane techniczne MagFlux®
Wyświetlacz
Klasa ochrony obudowy Pyłoszczelna i wodoszczelna IP 67, NEMA 6 (po
zamontowaniu na przetworniku)
Materiał obudowy Poliwęglan wzmocniony włóknem szklanym
Komunikacja MODBUS® w trybie RTU, 9600 bitów/s,
2-przewodowy interfejs RS 485, tryb urządzenia
nadrzędnego
Interfejs RS-485. Port USB 1.1, typ mini B, żeński
Pamięć
345.000 wpisów obejmujących datę, godzinę
i wartość
Przetwornik
Zakres pomiarowy MagFlux®:
Zakres = 0–10 m/s MagFlux® Q:
Zakres = 0–8 m/s
Min. przewodność cieczy ≥ 5 mS
Wyjścia cyfrowe Jeden beznapięciowy przekaźnik elektro-
mechaniczny (maks. 28 V (prąd stały) / 300
mA); jeden przekaźnik MOSFET z izolacją
optyczną (maks. 28 V (prąd przem.)/ V (prąd
stały)/500 mA)
Wejścia cyfrowe Jedno, maks. 28 V (prąd stały), < 2,5 V (prąd
stały) = 0 (stan niski), > 10 V (prąd stały) = 1
(stan wysoki), długość impulsu > 100 ms
Wyjście analogowe 1 szt. aktywne 4–20 mA, izolowane galwaniczne,
rozdzielczość 10 bitów, (maks. obciążenie 600 Ω)
Komunikacja
MODBUS® w trybie RTU, 9600 bitów/s,
2-przewodowy interfejs RS 485, tryb urządzenia
podrzędnego
Interfejs RS 485 do podłączenia wyświetlacza lub
sterownika PLC
Zasilanie 24 V (prąd przemienny), 50 / 60 Hz, ±10% lub
115 V (prąd przemienny), 50 / 60 Hz, ±10% lub
230V (prąd przemienny), 50 / 60Hz, ±10%
10-30 V (prąd stały)
Maks. pobór energii 10 W
Stopień ochrony IP oraz
materiał
Poliwęglan, wzmocniony włóknem szklanym
IP 67, NEMA 6
Ciężar 1,0 kg
Aprobaty UL File E 1940 21
Aprobaty CE EN 61000-6-4 2007-02-19, EN
61000-6-2 2005-09-08
Skrzynka rozdzielcza
Stopień ochrony IP oraz
materiał
IP 68, NEMA 6P (przy użyciu zestawu z żelem
do uszczelniania). Poliwęglan wzmocniony
włóknem szklanym
FR Caractéristiques MagFlux®
Affichage
Classement d'enveloppe Étanche à l'eau et à la poussière IP 67, NEMA 6
(en cas de montage sur le Convertisseur)
Matériau du boîtier Polycarbonate chargé verre
Communication Mode RTU MODBUS®, 9600 baud, RS 485 2 fils,
mode maître
Interface RS-485. USB 1.1 type mini B, femelle
Mémoire
345.000 entrées avec date, heure et valeur
Convertisseur
Gamme de mesure MagFlux®:
Gamme = 0-10 m/s MagFlux® Q:
Gamme = 0-8 m/s
Conductivité mini du liquide ≥ 5mS
Sorties numériques Un relais électromécanique hors potentiel (maxi
28 V DC / 300 mA) Un relais MOSFET à isolement
optique (maxi 28 V AC/ V DC / 500 mA)
Entrées numériques Une, maxi 28 V DC, < 2,5 V DC = 0 (bas), > 10 V
DC = 1 (haut), longueur d'impulsion > 100ms
Sortie analogique 1 pces. Active 4 - 20 mA, isolée galvaniquement,
résolution de 10 bits, (charge maxi 600 Ω)
Communication
Mode RTU Modbus®, 9600 baud, RS 485 2 fils,
mode esclave
Interface RS 485 pour connexion à un écran ou à un
automate
Alimentation 24 V CA, 50 / 60 Hz ± 10 % ou
115 V CA, 50 / 60 Hz ± 10 % ou
230 V CA, 50 / 60 Hz ± 10 %
10-30 V DC
Consommation maxi 10 W
Protection contre les
pénétrations et matériaux
Polycarbonate, chargé verre. IP 67, NEMA 6
Poids 1,0 kg
Homologations UL File E 1940 21. Homologations CE EN 61000-
6-4 2007-02-19, EN 61000-6-2 2005-09-08
Boîte de raccordement
Protection contre les
pénétrations et matériaux
IP 68, NEMA 6P (avec gel d'étanchéité). Polycar-
bonate chargé verre
ES Especificaciones MagFlux®
Display
Clasificación de la carcasa A prueba de polvo y agua IP 67, NEMA 6
(cuando está montado en el convertidor)
Material de la carcasa Policarbonato reforzado con vidrio
Comunicación Modo RTU MODBUS®, 9600 baudios, RS 485
de dos cables, modo maestro
Interfaz RS-485. USB 1.1 tipo mini B, hembra
Memoria
345.000 entradas con fecha, hora y valor
Convertidor
Rango de medición MagFlux®:
Rango = 0-10 m/s MagFlux® Q:
Rango = 0-8 m/s
Mín. conductividad del líquido ≥ 5 mS
Salidas digitales Un relé electromecánico sin tensión (máx. 28 V
DC / 300 mA) un relé MOSFET aislado óptica-
mente (máx. 28 V AC / V DC / 500 mA)
Entradas digitales Uno, máx. 28 V DC, < 2,5 V DC = 0 (bajo), > 10
V DC = 1 (alto), longitud de pulsos > 100 ms
Salida analógica 1 piezas. Activo 4 - 20 mA, aislado galvánica-
mente, resolución de 10 bits, (máx. carga 600 Ω)
Comunicación
Modo RTU MODBUS®, 9600 baudios, RS 485
de dos cables, modo esclavo
Interfaz RS 485 para la conexión con la unidad de
visualización o PLC
Fuente de alimentación 24 V CA, 50 / 60 Hz ± 10 % o
115 V CA, 50 / 60 Hz ± 10 % o
230 V CA, 50 / 60 Hz ± 10 %
10-30 V DC
Consumo de energía máx. 10 W
Material y protección de
ingreso
Policarbonato reforzado con vidrio.
IP 67, NEMA 6
Peso 1,0 kg
Aprobaciones UL File E 1940 21. Aprobaciones CE EN 61000-
6-4 2007-02-19, EN 61000-6-2 2005-09-08
Caja de conexiones
Material y protección de
ingreso
IP 68, NEMA 6P (uso del kit para encapsulación
con gel). Policarbonato reforzado con vidrio
PT Especificações MagFlux®
Display
Taxa de fecho À prova de pó e água IP 67, NEMA 6 (quando
montado no Conversor)
Material do invólucro Policarbonato reforçado com vidro
Comunicação Modo RTU MODBUS®, 9.600 bauds, 2 cabos
RS 485, modo mestre
Interface RS-485. USB 1.1 tipo mini B, Fêmea
Memória
345.000 entradas com data, hora e valor
Conversor
Intervalo de medição MagFlux®:
Intervalo = 0-10 m/s MagFlux® Q:
Intervalo = 0-8 m/s
Intensidade Condutividade
do líquido ≥ 5 mS
Saídas digitais Um relé electro-mecânico sem voltagem (máx.
28 V DC / 300 mA) Um relé MOSFET isolado
opticamente (máx. 28 V AC / V DC / 500 mA)
Entradas digitais Um, máx. 28 V DC, < 2,5 V DC = 0 (low), >
10 V DC = 1 (alto), comprimento do impulso
> 100 ms
Saída analógica 1 pçs. Activo 4 - 20 mA, isolado galvanicamen-
te, resolução de 10 bits, (máx. carga 600 Ω)
Comunicação
Modo RTU MODBUS®, 9.600 bauds, 2 cabos
RS 485, modo escravo
Interface RS 485 para ligação à Unidade de visualização
ou PLC
Fonte de alimentação 24 V AC, 50 / 60 Hz ± 10 % ou
115 V AC, 50 / 60 Hz ± 10 % ou
230 V AC, 50 / 60 Hz ± 10 %
10-30 V DC
Consumo máximo de energia 10 W
Protecção de entrada e material
Policarbonato, reforçado com vidro. IP 67, NEMA 6
Peso 1,0 kg
Aprovações UL File E 1940 21. Aprovações CE EN 61000-6-
4 2007-02-19, EN 61000-6-2 2005-09-08
Caixa de ligações
Protecção de entrada e
material
IP 68, NEMA 6P (utilizando kit de gel). Policar-
bonato reforçado com vidro
TR Spesifikasyonlar MagFlux®
Gosterin
Kutu Değeri Toz ve su geçirmez IP 67, NEMA 6
(Dönüştürücüye monte edildiğinde)
Gövde Malzemesi Cam katkılı Polikarbonat
İletişim MODBUS® RTU-mod, 9600 baud, 2-telli RS 485,
master-mod
Arayüz RS-485. USB 1.1 tip mini B, Dişi
Bellek
Zaman ve değer bilgileriyle 345.000 girdi
Dönüştürücü
Ölçüm Aralığı MagFlux®:
Aralık= 0-10 m/s MagFlux® Q:
Aralık= 0-8 m/s
Min. Sıvı İletkenliği ≥ 5 mS
Dijital Çıkışlar Bir voltajsız elektromekanik röle
(maks. 28 V DC / 300 mA)
Bir optoizole MOSFET röle (maks. 28 VAC / V
DC / 500 mA)
Dijital Girişler Bir tane, maks. 28 V DC, < 2,5 V DC = 0 (düşük),
> 10 V DC = 1 (yüksek), puls uzunluğu > 100 ms
Analog Çıkış 1 adet Aktif 4 - 20 mA, galvanik olarak izole
edilmiş, 10 bit çözünürlüklü, (maks. yük 600 Ω)
İletişim
MODBUS® RTU-mod, 9600 baud, 2-telli RS 485,
ikincil modu
Arayüz Ekran Ünitesi veya PLC'ye bağlantı için RS 485
Güç Kaynağı 24 V AC, 50 / 60 Hz ± 10 % veya
115 V AC, 50 / 60 Hz ± 10 % veya
230 V AC, 50 / 60 Hz ± 10 %
10-30 V DC
Enerji tüketimi maks. 10 W
Giriş Koruması ve Malzemesi
Polikarbonat, cam katkılı. IP 67, NEMA 6
Ağırlık 1,0 kg
Onaylar UL File E 1940 21. CE onayları EN 61000-6-4
2007-02-19, EN 61000-6-2 2005-09-08
Bağlantı Kutusu
Giriş Koruması ve Malzemesi
IP 68, NEMA 6P (jel koruma kiti parça). Cam
katkılı Polikarbonat
IT Specifiche MagFlux®
Display
Grado di protezione Antipolvere e impermeabile IP 67, NEMA 6 (se
montato sul convertitore)
Materiale del corpo Policarbonato rinforzato in fibra di vetro
Comunicazione MODBUS® modalità RTU, 9600 baud, RS 485
bifilare, modalità master
Interfaccia RS-485. USB 1.1 tipo mini B, femmina
Memoria
345.000 input con data, ora e valore
Convertitore
Intervallo di misurazione MagFlux®
Intervallo = 0-10 m/s MagFlux® Q:
Intervallo = 0-8 m/s
Min. conduttività dei liquidi ≥ 5 mS
Uscite digitali Un relè elettromeccanico senza tensione (max.
28 V DC / 300 mA). Un relè MOSFET isolato
otticamente (max. 28 V AC / V DC / 500 mA)
Ingressi digitali Uno, max. 28 V DC, < 2,5 V DC = 0 (basso), > 10
V DC = 1 (alto), lunghezza impulsi > 100 ms
Uscita analogica 1 pz. attiva 4 - 20 mA, isolata galvanicamente,
risoluzione 10 bit, (max. carico 600 Ω)
Comunicazione
MODBUS® modalità RTU, 9600 baud, RS 485
bifilare, modalità slave
Interfaccia RS 485 per la connessione all'unità schermo
o al PLC
Alimentazione 24 V AC, 50 / 60 Hz ± 10% o
115 V AC, 50 / 60 Hz ± 10% o
230 V AC, 50 / 60 Hz ± 10%
10-30 V DC
Assorbimento di energia max. 10 W
Classe di protezione IP e
materiale
Policarbonato, rinforzato con fibra di vetro
IP 67, NEMA 6
Peso 1,0 kg
Approvazioni UL File E 1940 21. Omologazioni CE EN 61000-
6-4 2007-02-19, EN 61000-6-2 2005-09-08
Scatola di connessione
Classe di protezione IP e
materiale
IP 68, NEMA 6P (con kit di isolamento gel).
Policarbonato rinforzato in fibra di vetro
HR Specifikacije MagFlux®
Prikaz
Razina zaštite kućišta Otporno na prašinu i vodonepropusno IP 67,
NEMA 6 (kada je ugrađen na pretvornik)
Materijal kućišta Staklom ojačani polikarbonat
Komunikacija MODBUS® RTU-način rada, 9600 baud, 2-žilni
RS 485, master način rada
Sučelje RS-485. USB 1.1 vrste mini B, ženski
Memorija
345.000 upisa sa datumom, vremenom i
vrijednostima
Pretvornik
Mjerno područje MagFlux®:
Raspon = 0-10 m/s MagFlux® Q:
Raspon = 0-8 m/s
Min. vodljivost tekućine ≥ 5 mS
Digitalni izlazi Jedan beznaponski elektro-mehanički relej
(maks. 28 V DC / 300 mA)
Jedan optički izolirani MOSFET relej (maks. 28
VAC / V DC / 500 mA)
Digitalni ulazi Jedan, maks. 28 V DC, < 2,5 V DC = 0 (nisko), >
10 V DC = 1 (visoko), dužina impulsa > 100 ms
Analogni izlaz 1 kom. Aktivni 4 - 20 mA, galvanski izoliran,
razlučivosti 10 bita, (maks. opterećenje 600 Ω)
Komunikacija
MODBUS® RTU-način rada, 9600 baud, 2-žilni
RS 485, slave način rada
Sučelje RS 485 za povezivanje na jedinicu zaslona ili PLC
Napajanje 24 V AC, 50 / 60 Hz ± 10 % ili
115 V AC, 50 / 60 Hz ± 10 % ili
230 V AC, 50 / 60 Hz ± 10 %
10-30 V DC
Potrošnja struje maks. 10 W
Stupanj zaštite i materijal
Polikarbonat, staklom ojačani. IP 67, NEMA 6
Težina 1,0 kg
Odobrenja UL File E 1940 21. CE odobrenja EN 61000-6-4
2007-02-19, EN 61000-6-2 2005-09-08
Priključna kutija
Stupanj zaštite i materijal
IP 68, NEMA 6P (uporaba kompleta za ispunu
smolom). Staklom ojačani polikarbonat
DK Specifikationer MagFlux®
Display
Kapsling Støv- og vandtæt IP 67, NEMA 6 (hvis monteret
på konverter)
Hus materiale Glas-forstærket Polykarbonat
Kommunikation MODBUS® RTU-mode, 9600 baud, 2-wire RS
485, master-mode
Interface RS-485. USB 1,1 type mini B, Hun
Hukommelse
345.000 logs med dato, tid og værdi
Konverter
Måleområde MagFlux®:
Område = 0-10 m/s MagFlux® Q:
Område = 0-8 m/s
Min. væske ledningsevne ≥ 5 µS
Digitale udgange En potentialfri, elektromekanisk relækontakt
(max. 28 V DC / 300 mA) + Et elektronisk relæ
(max. 28 VAC / V DC / 500 mA)
Digital indgang En, max. 28 V DC, < 2,5 V DC = 0 (lav ), > 10 V
DC = 1 (høj), pulslængde > 100 ms
Analog output 1 pcs. Active 4 - 20 mA, galvanically isolated, 10
bit resolution, (max. load 600 Ω)
Kommunikation
MODBUS® RTU-mode, 9600 baud, 2-wire RS
485, slave-mode
Interface RS 485 for tilslutning til Display eller PLC
Strømforsyning 24 V AC, 50 / 60 Hz ± 10 % or
115 V AC, 50 / 60 Hz ± 10 % or
230 V AC, 50 / 60 Hz ± 10 %
10-30 V DC
Strømforbrug max. 10 W
Kapsling og materiale
Polykarbonat,glasforstærket. IP 67, NEMA 6
Vægt 1,0 kg
Certifikater UL File E 1940 21
CE EN 61000-6-4 2007-02-19, EN 61000-6-2
2005-09-08
Samlebox
Kapsling og materiale
IP 68, NEMA 6P (ved brug af udstøbningssæt).
Glasforstærket Polykarbonat
Sensor Calibration Code
|
Back Select >
S/N not entered
Set Flow Direction
Follow Arrow A
Follow Arrow B
Back Select OK
MagFlux1
Flow 0.00 m 3/h
FTot 00.000 m 3
Select Setup
Service Menu
Sensor Calibration Code
Converter SW Ver.
Product Data
Reset Counter Time
Internal Meas. & Cal.
Minimum Velocity
Calibrate Flow now
Calibrate Volume
Calibrate mA
Test Velocity
Freeze Coil
Read Event Log
Back on Stock
Back Select OK
Set Flow Direction
Follow Arrow A
Follow Arrow B
Back Select OK
Sensor Calibration Code
Sensor Calibration Code
dw5uq4
Back Select OK
Sensor Calibration Code
A B
A B
Sensor Calibration Code
|
Back Select >
S/N not entered
Set Flow Direction
Follow Arrow A
Follow Arrow B
Back Select OK
MagFlux1
Flow 0.00 m 3/h
FTot 00.000 m 3
Select Setup
Service Menu
Sensor Calibration Code
Converter SW Ver.
Product Data
Reset Counter Time
Internal Meas. & Cal.
Minimum Velocity
Calibrate Flow now
Calibrate Volume
Calibrate mA
Test Velocity
Freeze Coil
Read Event Log
Back on Stock
Back Select OK
Set Flow Direction
Follow Arrow A
Follow Arrow B
Back Select OK
Sensor Calibration Code
Sensor Calibration Code
dzzwjrgl
Back Select OK
Sensor Calibration Code
A B
EN 1. Enter the calibration code read from the Sensor label +
2. Set Flow Direction and press OK
3. MagFlux is now configured with default settings and is ready for use DE 1. Geben Sie den Kalibrierkode ein, der auf dem Sensorlabel aufgedruckt ist +
2. Stellen Sie die Durchflussrichtung ein und drücken Sie OK
3. MagFlux ist jetzt mit den Grundeinstellungen konfiguriert und einsatzbereit. PL
1. Wpisz kod kalibracji odczytany z etykiety czujnika +
2. Ustaw Kierunek przepływu i naciśnij przycisk OK.
3. Przepływomierz MagFlux został skonfigurowany z ustawieniami domyślnymi i
jest gotowy do użycia.
FR
1. Entrer le code d'étalonnage lu sur l'étiquette du capteur +
2. Définir le Sens du débit et appuyer sur OK
3. MagFlux est maintenant configuré avec des paramètres par défaut et prêt à
l'utilisation
NL
1. Vul de kalibratiecode in die op het label van de sensor staat +
2. Stel de Flow Richting in en druk op OK
3. MagFlux is nu geconfigureerd met de standaardinstellingen en is klaar voor
gebruik.
HU
1. Adja meg az érzékelő címkéjén található kalibrálási kódot +
2. Állítsa be a áramlási irány értékét, majd nyomja meg az OK gombot
3. A MagFlux most már az alapértelmezett értékekkel van konfigurálva, és
használatra kész
ES
1. Introduzca el código de calibración que aparece en la etiqueta Sensor +
2. Establezca la Dirección de caudal y pulse OK
3. MagFlux ahora tiene la configuración prefeterminada y está preparado para
su uso
SE 1. Ange kalibreringskoden som står på sensoretiketten +
2. Välj Flödesriktning och tryck OK
3. MagFlux är nu konfigurerad med standardinställningarna och klar för drift RU
1. Введите код калибровки, считанный на уровне датчика +
2. Задайте Направление потока и нажмите Подтв.
3. Теперь конфигурация программы MagFlux выполнена с помощью настроек
по умолчанию, и она готова к работе
PT
1. Introduza a leitura do código de calibração a partir da etiqueta do sensor +
2. Defina a Sentido fluxo e prima OK
3. O MagFlux está agora configurado com as definições padrão e preparado para
utilização
NO 1. Angi avlesningen av kalibreringskoden fra sensormerket +
2. Still inn Framover / bakover flow, og trykk på OK
3. Nå er MagFlux konfigurert med standardinnstillinger og er klar til bruk. TR 1. Sensör etiketinden okuduğunuz kalibrasyon kodunu girin +
2. Debi yonu ayarlayın ve OK basın
3. MagFlux varsayılan ayarlarla yapılandırıldı ve artık kullanıma hazır
IT 1. Inserire il codice di calibrazione riportato sull'etichetta del sensore +
2. Configurare Verso del flusso e premere OK
3. Ora MagFlux è configurato con le impostazioni predefinite ed è pronto per l'uso DK 1. Indtast kalibreringskoden der står på sensor label +
2. Vælg Flow retningen og tryk OK
3. MagFlux er nu konfigureret med grundindstillingerne og klar til brug HR 1. Unesite šifru za kalibraciju koja se nalazi na naljepnici osjetnika +
2. Postavite Smjer strujanja i pritisnite OK
3. MagFlux je sada konfiguriran s zadanim postavkama i spreman je za uporabu
Sensor Calibration Code
|
Back Select >
S/N not entered
Set Flow Direction
Follow Arrow A
Follow Arrow B
Back Select OK
MagFlux1
Flow 0.00 m 3/h
FTot 00.000 m 3
Select Setup
Service Menu
Sensor Calibration Code
Converter SW Ver.
Product Data
Reset Counter Time
Internal Meas. & Cal.
Minimum Velocity
Calibrate Flow now
Calibrate Volume
Calibrate mA
Test Velocity
Freeze Coil
Read Event Log
Back on Stock
Back Select OK
Set Flow Direction
Follow Arrow A
Follow Arrow B
Back Select OK
Sensor Calibration Code
Sensor Calibration Code
dw5uq4
Back Select OK
Sensor Calibration Code
A B
A B
NO Spesifikasjoner MagFlux®
Display
Beskyttelsesgrad Støv- og vanntett IP 67, NEMA 6 (når montert
på omformeren)
Husmateriale Glassforsterket polykarbonat
Kommunikasjon MODBUS® RTU-modus, 9600 baud, 2-lednings
RS 485, mestermodus
Grensesnitt RS-485. USB 1.1 type mini B, hunn
Minne
345.000 innføringer med dato, klokkeslett
og verdi
Omformer
Måleområde MagFlux®:
Område = 0-10 m/s MagFlux® Q:
Område = 0-8 m/s
Væskens min. ledeevne ≥ 5 mS
Digitale utganger Ett spenningsfritt elektromekanisk relé (maks.
28 V DC / 300 A) Ett optisk isolert MOSFET-relé
(maks. 28 V AC / V DC / 500 mA)
Digitale innganger Én, maks. 28 V DC, < 2,5 V DC = 0 (lav), > 10 V
DC = 1 (høy), pulslengde > 100 ms
Analog utgang 1 stk. Aktiv 4-20 mA, galvanisk isolert, 10-bit
oppløsning, (maks. Belastning 600 Ω)
Kommunikasjon
MODBUS® RTU-modus, 9600 baud, 2-lednings
RS 485, slavemodus
Grensesnitt RS 485 til tilkobling til skjermenheten eller PLC
Strømforsyning 24 V AC, 50 / 60 Hz ± 10 % eller
115 V AC, 50 / 60 Hz ± 10 % eller
230 V AC, 50 / 60 Hz ± 10 %
10-30 V DC
kraftforbruk maks. 10 W
Inntrengningsbeskyttelse og
-materiale
Polykarbonat, glassforsterket
IP 67, NEMA 6
Vekt 1,0 kg
Godkjenninger UL File E 1940 21.
CE-godkjenninger EN 61000-6-4 2007-02-19,
EN 61000-6-2 2005-09-08
Koblingsboks
Inntrengningsbeskyttelse og
-materiale
IP 68, NEMA 6P (bruk gelinnstøpningssett).
Glassforsterket polykarbonat
RU Технические характеристики MagFlux®
дисплей
Класс защиты корпуса Пыле- и влагонепроницаемость - IP 67, NEMA
6 (при монтаже на преобразователь)
Материал кожуха Поликарбонат, упрочненный стекловолокном
Система связи Режим RTU канала MODBUS®, 9600 бод,
2-проводная линия RS 485, режим ведущего
устройства
Интерфейс RS-485. USB 1.1 типа мини B, штекер
Память
345.000 записей с датой, временем и
значением
Преобразователь
Диапазон изменений MagFlux®:
диапазон = 0-10 м/с
MagFlux® Q:
диапазон = 0-8 м/с
Мин. Проводимость жидкости ≥ 5 мСм
Цифровые выходы Одно электромеханическое реле с сухими
контактами (не более 28 В пост. тока / 300
mА) Одно оптически изолированное реле
MOSFET (не более 28 В перем. тока / В пост.
тока / 500 мА)
Цифровые входы Один, не более 28 В пост. тока, < 2,5 В
пост. тока = 0 (низкое), > 10 В пост. тока =
1 (высокое), продолжительность импульса
> 100 мс
Аналоговый выход 1 шт. Активный 4 - 20 мА, гальванически
развязанный, разрешение 10 бит,
(максимальная нагрузка 600 Ом)
Система связи
Режим RTU канала MODBUS®, 9600
бод, 2-проводная линия RS 485, режим
подчиненного устройства
Интерфейс RS 485 для подключения к дисплею или ПЛК
Источник питания 24 В перем. тока, 50 / 60 Гц ± 10 % или
115 В перем. тока, 50 / 60 Гц ± 10 % или
230 В перем. тока, 50 / 60 Гц ± 10 %
10-30 В пост. тока
Энергопотребление не более 10 Вт
Класс защиты от
проникновения загрязнений
и материал
Поликарбонат, упрочненный стекловолокном
IP 67, NEMA 6
Вес 1,0 кг
Одобрения UL File E 1940 21.
Одобрение CE согласно EN 61000-6-4 2007-
02-19, EN 61000-6-2 2005-09-08
Распределительная коробка
Защита от проникновения и
материал
IP 68, NEMA 6P (с использованием
набора для заливки геля). Поликарбонат,
армированный стеклом
SE Specifikationer MagFlux®
Display
Kapslingsklass Damm- och vattentät IP 67, NEMA 6 (vid
montering på omvandlare)
Husmaterial Glasarmerad polykarbonat
Kommunikation MODBUS® RTU-läge, 9600 baud, 2-tråds RS
485, masterläge
Gränssnitt RS-485. USB 1.1 typ mini-B, hona
Minne
345.000 poster med datum, tid och värde
Omvandlare
Mätintervall MagFlux®:
Område = 0-10 m/s MagFlux® Q:
Område = 0-8 m/s
Min. vätskeledningsförmåga ≥ 5 mS
Digitala utgångar En potentialfri elektromagnetisk reläkontakt
(max. 28 V DC / 300 mA) En optiskt isolerad
MOSFET-reläkontakt (max. 28 V AC/V DC/
500 mA)
Digitala ingångar En, max. 28 V DC, < 2,5 V DC = 0 (låg), > 10 V
DC = 1 (hög), pulslängd > 100 ms
Analog utgång 1 st. Aktiv 4 - 20 mA, galvaniskt isolerad, 10
bitars upplösning, (max. last 600 Ω)
Kommunikation
MODBUS® RTU-läge, 9600 baud, 2-tråds RS
485, slavläge
Gränssnitt RS 485 för kommunikation till displayenhet
eller PLC
Strömförsörjning 24 V AC, 50 / 60 Hz ± 10 % eller
115 V AC, 50 / 60 Hz ± 10 % eller
230 V AC, 50 / 60 Hz ± 10 %
10-30 V DC
Max. effektförbrukning 10 W
Kapsling och material
Polykarbonat, glasarmerad. IP 67, NEMA 6
Vikt 1,0 kg
Godkännanden UL File E 1940 21. CE-godkännande EN 61000-
6-4 2007-02-19, EN 61000-6-2 2005-09-08
Kopplingsbox
Kapsling och material
IP 68, NEMA 6P (med användning av ingjut-
ningssats). Glasarmerad polykarbonat
HU Műszaki adatok MagFlux®
Diszplé
Ház besorolása IP 67 por- és vízálló, NEMA 6 (a konverterre
felszerelt állapotban)
Ház anyaga Üvegszál-erősítésű polikarbonát
Kommunikáció MODBUS® RTU mód, 9600 baud, 2 huzalos RS
485, fő egységüzemmód
Interfész RS-485. USB 1.1 mini B típus, aljzat
Memória
345.000 bevitel dátummal, időponttal és
értékkel
Konverter
Mérési tartomány MagFlux®:
Tartomány = 0–10 m/s MagFlux® Q:
Tartomány = 0–8 m/s
Min. folyadék
vezetőképessége ≥ 5 mS
Digitális kimenetek Egy feszültségmentes elektromechanikus relé
(max. 28 V egyenáram/300 mA) egy optikailag
leválasztott MOSFET relé (max. 28 V váltakozó
áram/V egyenáram/500 mA)
Digitális bementek Egy, max. 28 V egyenáram, < 2,5 V egyenáram
= 0 (alacsony), > 10 V egyenáram = 1 (magas),
impulzushossz > 100 ms
Analóg kimenet 1 db Aktív 4–20 mA, elektromosan elszigetelt,
10 bites felbontás, (max. terhelés: 600 Ω)
Kommunikáció
MODBUS® RTU mód, 9600 baud, 2 huzalos RS
485, alárendelt üzemmód
Interfész RS 485 kijelző egység vagy PLC csatlakoz-
tatásához
Áramellátás 24 V váltóáram, 50/60 Hz ± 10 % vagy
115 V váltóáram, 50/60 Hz ± 10 % vagy
230 V váltóáram, 50/60 Hz ± 10 %
10-30 V egyenáram
Maximális áramfogyasztás 10 W
Behatolás elleni védelem
és anyag
Üvegszál-erősítésű polikarbonát. IP 67, NEMA 6
Tömeg 1,0 kg
Jóváhagyások UL File E 1940 21. CE tanúsítványok, EN 61000-
6-4 2007-02-19, EN 61000-6-2 2005-09-08
Csatlakozódoboz
Behatolás elleni védelem
és anyag
IP 68, NEMA 6P (hermetizáló gél használtával).
Üvegszál-erősítésű polikarbonát
NL Specificaties MagFlux®
Display
Classificatie van de
behuizing Stof- en waterbestendig IP 67, NEMA 6 (wan-
neer gemonteerd op de omzetter)
Materiaal van de behuizing Met glasvezel versterkt polycarbonaat
Communicatie MODBUS® RTU-modus, 9600 baud, 2-draads
RS 485, master-modus
Interface RS-485. USB 1,1 type mini B, Vrouw
Geheugen
345.000 invoermogelijkheden met datum, tijd
en waarde
Omzetter
Meetbereik MagFlux®:
Bereik = 0-10 m/s MagFlux®Q:
Bereik = 0-8 m/s
Min. Geleidbaarheid van
vloeistoffen ≥ 5 mS
Digitale uitgangen Eén spanningsvrij elektromechanisch
relais (max. 28 V DC / 300 mA) Eén optisch
geïsoleerd MOSFET-relais (max. 28 V AC/ V
DC / 500 mA)
Digitale ingangen Eén, max. 28 V DC, < 2,5 V DC = 0 (laag ), > 10
V DC = 1 (hoog), pulslengte > 100 ms
Analoge uitgang 1 x Active 4 - 20 mA, galvanisch geïsoleerd, 10
bit resolutie, (max. belasting 600 Ω)
Communicatie
MODBUS® RTU-modus, 9600 baud, 2-draden
RS 485, slave-modus
Interface RS 485 voor koppeling met Beeldscherm of PLC
Netvoeding 24 V AC, 50 / 60 Hz ± 10 % of
115 V AC, 50 / 60 Hz ± 10 % of
230 V AC, 50 / 60 Hz ± 10 %
10-30 V DC
Stroomverbruik max. 10 W
Bescherming tegen
binnendringen en materiaal
Polycarbonaat, versterkt met glasvezel
IP 67, NEMA 6
Gewicht 1,0 kg
Goedkeuringen UL File E 1940 21.
CE-goedkeuringen EN 61000-6-4 2007-02-19,
EN 61000-6-2 2005-09-08
Aansluitdoos
Bescherming tegen
binnendringen en materiaal
IP 68, NEMA 6P (met gelpotset). Met glasvezel
versterkt polycarbonaat
DE Technische Daten MagFlux®
Anzeige
Gehäuseschutzart Staub und wassserdicht IP 67, NEMA 6 (bei
Montage an Messumformer)
Gehäusewerkstoff Glasfaserverstärktes Polykarbonat
Kommunikation MODBUS® RTU-Modus, 9600 Baud, RS-485 mit
2-Drahtanschluss, Master-Modus
Schnittstelle RS-485. USB 1.1 Mini-B-Buchse
Speicher
345.000 Einträge mit Datum, Zeit und Wert
Messumformer
Messbereich MagFlux®:
Bereich = 0 bis 10 m/s MagFlux® Q:
Bereich = 0 bis 8 m/s
Min. Leitfähigkeit der
Flüssigkeit ≥ 5 mS
Digitalausgänge Ein elektromechanisches Relais mit potential-
freien Kontakten (max. 28 V DC / 300 mA) Ein
durch Optokoppler getrenntes MOSFET-Relais
(max.. 28 V AC/ V DC/500 mA)
Digitaleingänge Einer, max. 28 V DC, < 2,5 V DC = 0 (Low), > 10
V DC = 1 (High), Impulslänge > 100 ms
Analogausgang 1 Stück Aktiv 4 - 20 mA, galvanisch getrennt, 10
Bit Auflösung, (max. Bürde 600 Ω)
Kommunikation
MODBUS® RTU-Modus, 9600 Baud, RS-485 mit
2-Drahtanschluss, Slave-Modus
Schnittstelle RS-485 zum Anschluss an Anzeige oder SPS
Stromversorgung 24 V AC, 50 / 60 Hz ± 10 % oder
115 V AC, 50 / 60 Hz ± 10 % oder
230 V AC, 50 / 60 Hz ± 10 %
10-30 V DC
Leistungsaufnahme: max 10 W
Schutzart und Material
Polykarbonat, glasfaserverstärkt. IP 67, NEMA 6
Gewicht 1,0 kg
Zulassungen UL File E 1940 21.
CE Zulassung nach EN 61000-6-4 2007-02-19,
EN 61000-6-2 2005-09-08
Anschlussbox
Schutzart und Material
IP 68, NEMA 6P (mit Vergussgel). Glasfaserver-
stärktes Polykarbonat
REMOTE COMPACT
EN
To setup or change Flow direction, from Main Menu select
1. Converter Setup
2. Service Menu
3. Enter code (00000) and select Sensor Calibration Code
4. Follow instructions regarding Remote as shown to the left
DE
Zum Einrichten oder Ändern der Durchflussrichtung wählen Sie aus dem
Hauptbildschirm
1. Konverter Einstellung
2. Service Menü
3. Geben Sie den Kode (00000) ein und wählen Sie den Sensor CalCode
4. Folgen Sie den Anweisungen zu Remote wie links gezeigt
PL
Aby skonfigurować ustawienie Kierunek przepływu, na ekranie Menu główne
wybierz opcje:
1. Ustawienie przetwornika
2. Menu serwisowe
3. Wpisz kod (00000) i wybierz opcję Kod kalibracji czujnika
4. Wykonaj czynności opisane w lewo Zdalny
FR
Pour configurer ou modifier le sens du débit, sélectionner sur le Écran d'accueil
1. Section de mesure install.
2. Menu service
3. Entrer le code (00000) et sélectionner le Code de calibration capteur
4. Suivre les instructions correspondant à Distant comme montré à gauche
NL
Voor het instellen of het veranderen van de stroomrichting selecteert u vanaf het
Hoofdscherm
1. Converter Instelling
2. Service Menu
3. Vul de code (00000) in en selecteer de Kalibratiecode Sensor
4. Volg de instructies t.a.v. Extern zoals links getoond
HU
A beállításhoz vagy az áramlási irány módosításához válassza ki az alábbi elemeket
a Fő képernyő:
1. Jelátalakító beállytása
2. Szervíz menu
3. Adja meg a kódot (00000), majd válassza ki a Az érzékelő kalibrálási kódja elemet
4. Kövesse a Távoli elemmel kapcsolatos utasításokat a bal oldalon látható
ES
Para configurar o cambiar la dirección de caudal, en el Menú principal, seleccione
1. Montaje convertidor
2. Menú de servicio
3. Introduzca el código (00000) y seleccione Codigo de calibracion del sensor
4. Siga las instrucciones relativas a Remoto como se muestra a la izquierda
SE
För att ställa in eller ändra flödesriktning, välj följande från Processbild
1. Inställning av elektronik
2. Servicemeny
3. Ange koden (00000) och välj Sensorns kalibreringskod
4. Följ anvisningarna för Fjärr som visas till vänster
RU
Для настройки или изменения направления потока выберите в Main Menu
1. Установки конвертера
2. Сервисное меню
3. Введите код (00000) и выберите Код калибровки сенсора
4. Следуйте инструкциям в отношении варианта Дистанционный, как показано слева
PT
Para configurar ou alterar a direcção do Fluxo, a partir do Tela principal seleccione
1. Conversor setup
2. Menu do serviço
3. Introduza o código (00000) e seleccione Código da Calibração do Sensor
4. Siga as instruções sobre Remoto como mostrado à esquerda
NO
For å sette opp eller endre strømningsretning fra Prosessbilde
1. Konverter innstillinger
2. Service meny
3. Angi kode (00000) og velg Sensor kalibreringskode
4. Følg instruksjonene som gjelder Fjern som vist til venstre
TR
Akış yönünü ayarlamak veya değiştirmek için Ana Ekran'den sırasıyla şunları seçin
1. Akis degistirici kurulumu
2. Service Menu
3. Kodu (00000) girin ve Sensor Calibration Code seçin
4. Solda gösterildiği gibi Uzaktan ile ilgili talimatları izleyin
IT
Per configurare o modificare la direzione del flusso, selezionare in Pagina Superv.
1. Configura Convertitore
2. Menù di Servizio
3. Inserire il codice (00000) e selezionare Codice Calibrazione Sensore
4. Seguire le istruzioni per Remoto, come mostrato a sinistra
DK
Opsætning eller ændring af flowretning, vælg fra Main Menu
1. Converter Setup
2. Service Menu
3. Indtast kode (00000) og vælg Sensor Calibration Code
4. Følg instruktionerne vedrørende Remote som vist til venstre
HR
Za postavljanje ili promjenu pravca protoka, u Glavni prikaz odaberite sljedeće
1. Postavke pretvornika
2. Servisni izbornik
3. Unesite šifru (00000) i odaberite Kalibracijski kod senzora
4. Slijedite upute povezane s opcijom Remote kao što je prikazano na desnoj strani
GB MagFlux Manual 0808
Electromagnetic Flow Meter
Averaging Units mA Output
Minimum Flow
Averaging
0010 sec
Back Select >
Flow Forward
Flow Reverse
Forward & rev. (12mA=0)
Forward & rev. (4 mA=0)
Not in use
Back Select OK
mA Output
20 mA = 20.000 m
3
/t
Back Select >
Minimum Flow
0.177 m
3
/h
Back Select >
Flow
m
3
/sec
l/sec
l/min
l/h
m
3
/h
ft
3
/h
MGD
GPM
Back Select OK
Flow Forward
mA Output
20 mA = 20.000 m
3
/t
Back Select >
(4mA = 0 Flow)
Flow Reverse
mA Output
4 mA = 20.000 m
3
/t
20 mA = -20.000
Back Select >
(12mA = 0 Flow, +4mA = -
20mA)
Forward & rev. (12mA=0)
mA Output
4 mA = 0.00 m
3
/t
20 mA = 20.000 m
3
/t
Back Select >
(4mA = 0 Flow)
Forward & rev.
(4 mA=0)
Converter Setup
Minimum Flow
Averaging
Units
mA Output
R Totalizer Forward
R Totalizer Reverse
R Totalizer Sum
NR Totalizer Forward
NR Totalizer Reverse
NR Totalizer Sum
Batch Counter 1
Batch Counter 2
High Flow
Low Flow
Flow Direction
Empty Pipe
Status
Service Menu
Back Select OK
24h Flow Not in use
R Totalizer Forward
Electro-mechanical Relay
Opto Relay
Display only
Back Select OK
On-time
00100 mSec
Back Select >
Totalizer Forward Unit
l
hl
kl
m
3
ft
3
gal
MG
Back Select OK
Electro-mechanical Relay Opto Relay Display only Electro-mechanical Relay Opto Relay Display only
R Totalizer Reverse
Electro-mechanical Relay
Opto Relay
Display only
Back Select OK
Volume between Pulses
01.00000 m
3
Back Select >
Totalizer Forward Unit
l
hl
kl
m
3
ft
3
gal
MG
Back Select OK
Totalizer Forward Unit
l
hl
kl
m
3
ft
3
gal
MG
Back Select OK
Reset with Digital Input
Yes
No
Back Select OK
On-time
00010 Sec
Back Select >
Volume between Pulses
01.00000 m
3
Back Select >
Reset with Digital Input
Yes
No
Back Select OK
Reset with Digital Input
Yes
No
Back Select OK
On-time
00100 mSec
Back Select >
Totalizer Forward Unit
l
hl
kl
m
3
ft
3
gal
MG
Back Select OK
Volume between Pulses
01.00000 m
3
Back Select >
Totalizer Forward Unit
l
hl
kl
m
3
ft
3
gal
MG
Back Select OK
Totalizer Forward Unit
l
hl
kl
m
3
ft
3
gal
MG
Back Select OK
Reset with Digital Input
Yes
No
Back Select OK
On-time
00100 mSec
Back Select >
Volume between Pulses
01.00000 m
3
Back Select >
Reset with Digital Input
Yes
No
Back Select OK
Reset with Digital Input
Yes
No
Back Select OK
R Totalizer Sum
Totalizer Forward Unit
l
hl
kl
m
3
ft
3
gal
MG
Back Select OK
Reset with Digital Input
Yes
No
Back Select OK
NR Totalizer Forward Batch Counter 1
NR Totalizer Reverse
Reseting the
Batch Counter 1
Automatic
Manually
Adaptive
Back Select OK
Electro-mechanical Relay
Opto Relay
Not in use
Back Select OK
Electro-mechanical Relay Opto Relay
Number of
preSelected (Units)
00.002778 m
3
Back Select >
Not in use
Totalizer Forward Unit
l
hl
kl
m
3
ft
3
gal
MG
Back Select OK
Totalizer Reverse Unit
l
hl
kl
m
3
ft
3
gal
MG
Back Select OK
NR Totalizer Sum
Totalizer total Unit
l
hl
kl
m
3
ft
3
gal
MG
Back Select OK
Batch Counter 1 Unit
l
hl
kl
m
3
ft
3
gal
MG
Back Select OK
Pause with Digital Input
Yes
No
Back Select OK
Adaptive
Maximum Correction
20%
Back Select >
Reset Batch Error
Yes
No
Back Select OK
Automatic
Batch Counter 1 Unit
l
hl
kl
m
3
ft
3
gal
MG
Back Select OK
Pause with Digital Input
Yes
No
Back Select OK
Reseting the
Batch Counter 1
Automatic
Manually
Adaptive
Back Select OK
On-time
00100 mSec
Back Select >
Number of
preselected (Units)
00.002778 m
3
Back Select >
Number of
preSelected (Units)
00.002778 m
3
Back Select >
Manually
Batch Counter 2
Reseting the
Batch Counter 2
Automatic
Manually
Adaptive
Back Select OK
Electro-mechanical Relay
Opto Relay
Not in use
Back Select OK
Electro-mechanical Relay Opto Relay
Number of
preselected (Units)
00.002778 m
3
Back Select >
Not in use
Batch Counter 2 Unit
l
hl
kl
m
3
ft
3
gal
MG
Back Select OK
Pause with Digital Input
Yes
No
Back Select OK
Adaptive
Maximum Correction
20%
Back Select >
Reset Batch Error
Yes
No
Back Select OK
Automatic
Batch Counter 2 Unit
l
hl
kl
m
3
ft
3
gal
MG
Back Select OK
Pause with Digital Input
Yes
No
Back Select OK
Reseting the
Batch Counter 2
Automatic
Manually
Adaptive
Back Select OK
On-time
00100 mSec
Back Select >
Number of
preselected (Units)
00.02778m
3
Back Select >
Number of
preSelected (Units)
00.002778 m
3
Back Select >
Manually
High Flow
ON at Flow
10.000 m
3
/h
Back Select >
Relay Function
NO
NC
Back Select >
OFF at Flow
9.800 m
3
/h
Back Select >
Low Flow
Electro-mechanical Relay
Opto Relay
Display only
Not in use
Back Select OK
Delay
00010 Sec
Back Select OK
Electro-mechanical Relay
Opto Relay
Display only
Not in use
Back Select OK
Electro-mechanical Relay Opto Relay Display only
ON at Flow
10.000 m3/h
Back Select >
OFF at Flow
9.800 m3/h
Back Select >
ON at Flow
10.000 m3/h
Back Select >
OFF at Flow
9.800 m3/h
Back Select >
Delay
00010 Sec
Back Select OK
Delay
00010 Sec
Back Select OK
ON at Flow
176,4 m3/h
Back Select >
Relay Function
NO
NC
Back Select >
Off at Flow
170,0 m3/h
Back Select >
Delay
00010 Sec
Back Select >
Electro-mechanical Relay Opto Relay Display only
ON at Flow
176,4 m3/h
Back Select >
Off at Flow
170,0 m3/h
Back Select >
ON at Flow
176,4 m3/h
Back Select >
Off at Flow
170,0 m3/h
Back Select >
Delay
00010 Sec
Back Select >
Delay
00010 Sec
Back Select >
Relay Function
NO
NC
Back Select >
Relay Function
NO
NC
Back Select >
Relay Function
NO
NC
Back Select >
Relay Function
NO
NC
Back Select >
Flow Direction
Electro-mechanical Relay
Opto Relay
Display only
Not in use
Back Select OK
Electro-mechanical Relay Opto Relay Display only
Relay Function
NO
NC
Back Select OK
Empty Pipe
Electro-mechanical Relay
Opto Relay
Display only
Not in use
Back Select OK
Delay
00010 Sec
Back Select >
Delay
00010 Sec
Back Select >
Delay
00010 Sec
Back Select >
Electro-mechanical Relay Opto Relay Display only
Relay Function
NO
NC
Back Select OK
Delay
00010 Sec
Back Select >
Delay
00010 Sec
Back Select >
Delay
00010 Sec
Back Select >
Service Menu
Sensor Calibration Code
Converter SW Ver.
Product Data
Reset Counter Time
Internal Meas. & Cal.
Minimum Velocity
Calibrate Flow now
Calibrate Volume
Calibrate mA
Test Velocity
Freeze Coil
Read Event Log
Back on Stock
Back Select OK
OK
Relay Function
NO
NC
Back Select >
Relay Function
NO
NC
Back Select >
Relay Function
NO
NC
Back Select >
Relay Function
NO
NC
Back Select >
Status
DO1 Not in use
DO2 R Totalizer Forward
DI R Totalizer Forward
mA output 6.250 mA
Back Select OK
Password
Specify Main Screen Factory Settings Data Logger Set Sensor Name Display Setup
Converter Setup
Main Menu
.
.
Service Menu
.
Converter Setup
Back Select OK
Converter Setup
Back Select OK
Converter Setup
Back Select OK
Type Password
00000
Back Select >
Converter Setup Menu Overview
Gf-2
GB MagFlux Manual 0808
Electromagnetic Flow Meter
Averaging Units mA Output
Minimum Flow
Averaging
0010 sec
Back Select >
Flow Forward
Flow Reverse
Forward & rev. (12mA=0)
Forward & rev. (4 mA=0)
Not in use
Back Select OK
mA Output
20 mA = 20.000 m
3
/t
Back Select >
Minimum Flow
0.177 m
3
/h
Back Select >
Flow
m
3
/sec
l/sec
l/min
l/h
m
3
/h
ft
3
/h
MGD
GPM
Back Select OK
Flow Forward
mA Output
20 mA = 20.000 m
3
/t
Back Select >
(4mA = 0 Flow)
Flow Reverse
mA Output
4 mA = 20.000 m
3
/t
20 mA = -20.000
Back Select >
(12mA = 0 Flow, +4mA = -
20mA)
Forward & rev. (12mA=0)
mA Output
4 mA = 0.00 m
3
/t
20 mA = 20.000 m
3
/t
Back Select >
(4mA = 0 Flow)
Forward & rev.
(4 mA=0)
Converter Setup
Minimum Flow
Averaging
Units
mA Output
R Totalizer Forward
R Totalizer Reverse
R Totalizer Sum
NR Totalizer Forward
NR Totalizer Reverse
NR Totalizer Sum
Batch Counter 1
Batch Counter 2
High Flow
Low Flow
Flow Direction
Empty Pipe
Status
Service Menu
Back Select OK
24h Flow Not in use
R Totalizer Forward
Electro-mechanical Relay
Opto Relay
Display only
Back Select OK
On-time
00100 mSec
Back Select >
Totalizer Forward Unit
l
hl
kl
m
3
ft
3
gal
MG
Back Select OK
Electro-mechanical Relay Opto Relay Display only Electro-mechanical Relay Opto Relay Display only
R Totalizer Reverse
Electro-mechanical Relay
Opto Relay
Display only
Back Select OK
Volume between Pulses
01.00000 m
3
Back Select >
Totalizer Forward Unit
l
hl
kl
m
3
ft
3
gal
MG
Back Select OK
Totalizer Forward Unit
l
hl
kl
m
3
ft
3
gal
MG
Back Select OK
Reset with Digital Input
Yes
No
Back Select OK
On-time
00010 Sec
Back Select >
Volume between Pulses
01.00000 m
3
Back Select >
Reset with Digital Input
Yes
No
Back Select OK
Reset with Digital Input
Yes
No
Back Select OK
On-time
00100 mSec
Back Select >
Totalizer Forward Unit
l
hl
kl
m
3
ft
3
gal
MG
Back Select OK
Volume between Pulses
01.00000 m
3
Back Select >
Totalizer Forward Unit
l
hl
kl
m
3
ft
3
gal
MG
Back Select OK
Totalizer Forward Unit
l
hl
kl
m
3
ft
3
gal
MG
Back Select OK
Reset with Digital Input
Yes
No
Back Select OK
On-time
00100 mSec
Back Select >
Volume between Pulses
01.00000 m
3
Back Select >
Reset with Digital Input
Yes
No
Back Select OK
Reset with Digital Input
Yes
No
Back Select OK
R Totalizer Sum
Totalizer Forward Unit
l
hl
kl
m
3
ft
3
gal
MG
Back Select OK
Reset with Digital Input
Yes
No
Back Select OK
NR Totalizer Forward Batch Counter 1
NR Totalizer Reverse
Reseting the
Batch Counter 1
Automatic
Manually
Adaptive
Back Select OK
Electro-mechanical Relay
Opto Relay
Not in use
Back Select OK
Electro-mechanical Relay Opto Relay
Number of
preSelected (Units)
00.002778 m
3
Back Select >
Not in use
Totalizer Forward Unit
l
hl
kl
m
3
ft
3
gal
MG
Back Select OK
Totalizer Reverse Unit
l
hl
kl
m
3
ft
3
gal
MG
Back Select OK
NR Totalizer Sum
Totalizer total Unit
l
hl
kl
m
3
ft
3
gal
MG
Back Select OK
Batch Counter 1 Unit
l
hl
kl
m
3
ft
3
gal
MG
Back Select OK
Pause with Digital Input
Yes
No
Back Select OK
Adaptive
Maximum Correction
20%
Back Select >
Reset Batch Error
Yes
No
Back Select OK
Automatic
Batch Counter 1 Unit
l
hl
kl
m
3
ft
3
gal
MG
Back Select OK
Pause with Digital Input
Yes
No
Back Select OK
Reseting the
Batch Counter 1
Automatic
Manually
Adaptive
Back Select OK
On-time
00100 mSec
Back Select >
Number of
preselected (Units)
00.002778 m
3
Back Select >
Number of
preSelected (Units)
00.002778 m
3
Back Select >
Manually
Batch Counter 2
Reseting the
Batch Counter 2
Automatic
Manually
Adaptive
Back Select OK
Electro-mechanical Relay
Opto Relay
Not in use
Back Select OK
Electro-mechanical Relay Opto Relay
Number of
preselected (Units)
00.002778 m
3
Back Select >
Not in use
Batch Counter 2 Unit
l
hl
kl
m
3
ft
3
gal
MG
Back Select OK
Pause with Digital Input
Yes
No
Back Select OK
Adaptive
Maximum Correction
20%
Back Select >
Reset Batch Error
Yes
No
Back Select OK
Automatic
Batch Counter 2 Unit
l
hl
kl
m
3
ft
3
gal
MG
Back Select OK
Pause with Digital Input
Yes
No
Back Select OK
Reseting the
Batch Counter 2
Automatic
Manually
Adaptive
Back Select OK
On-time
00100 mSec
Back Select >
Number of
preselected (Units)
00.02778m
3
Back Select >
Number of
preSelected (Units)
00.002778 m
3
Back Select >
Manually
High Flow
ON at Flow
10.000 m
3
/h
Back Select >
Relay Function
NO
NC
Back Select >
OFF at Flow
9.800 m
3
/h
Back Select >
Low Flow
Electro-mechanical Relay
Opto Relay
Display only
Not in use
Back Select OK
Delay
00010 Sec
Back Select OK
Electro-mechanical Relay
Opto Relay
Display only
Not in use
Back Select OK
Electro-mechanical Relay Opto Relay Display only
ON at Flow
10.000 m3/h
Back Select >
OFF at Flow
9.800 m3/h
Back Select >
ON at Flow
10.000 m3/h
Back Select >
OFF at Flow
9.800 m3/h
Back Select >
Delay
00010 Sec
Back Select OK
Delay
00010 Sec
Back Select OK
ON at Flow
176,4 m3/h
Back Select >
Relay Function
NO
NC
Back Select >
Off at Flow
170,0 m3/h
Back Select >
Delay
00010 Sec
Back Select >
Electro-mechanical Relay Opto Relay Display only
ON at Flow
176,4 m3/h
Back Select >
Off at Flow
170,0 m3/h
Back Select >
ON at Flow
176,4 m3/h
Back Select >
Off at Flow
170,0 m3/h
Back Select >
Delay
00010 Sec
Back Select >
Delay
00010 Sec
Back Select >
Relay Function
NO
NC
Back Select >
Relay Function
NO
NC
Back Select >
Relay Function
NO
NC
Back Select >
Relay Function
NO
NC
Back Select >
Flow Direction
Electro-mechanical Relay
Opto Relay
Display only
Not in use
Back Select OK
Electro-mechanical Relay Opto Relay Display only
Relay Function
NO
NC
Back Select OK
Empty Pipe
Electro-mechanical Relay
Opto Relay
Display only
Not in use
Back Select OK
Delay
00010 Sec
Back Select >
Delay
00010 Sec
Back Select >
Delay
00010 Sec
Back Select >
Electro-mechanical Relay Opto Relay Display only
Relay Function
NO
NC
Back Select OK
Delay
00010 Sec
Back Select >
Delay
00010 Sec
Back Select >
Delay
00010 Sec
Back Select >
Service Menu
Sensor Calibration Code
Converter SW Ver.
Product Data
Reset Counter Time
Internal Meas. & Cal.
Minimum Velocity
Calibrate Flow now
Calibrate Volume
Calibrate mA
Test Velocity
Freeze Coil
Read Event Log
Back on Stock
Back Select OK
OK
Relay Function
NO
NC
Back Select >
Relay Function
NO
NC
Back Select >
Relay Function
NO
NC
Back Select >
Relay Function
NO
NC
Back Select >
Status
DO1 Not in use
DO2 R Totalizer Forward
DI R Totalizer Forward
mA output 6.250 mA
Back Select OK
Password
Specify Main Screen Factory Settings Data Logger Set Sensor Name Display Setup
Converter Setup
Main Menu
.
.
Service Menu
.
Converter Setup
Back Select OK
Converter Setup
Back Select OK
Converter Setup
Back Select OK
Type Password
00000
Back Select >
Converter Setup Menu Overview
Gf-2
...
GB MagFlux Manual 0808
Electromagnetic Flow Meter
Averaging Units mA Output
Minimum Flow
Averaging
0010 sec
Back Select >
Flow Forward
Flow Reverse
Forward & rev. (12mA=0)
Forward & rev. (4 mA=0)
Not in use
Back Select OK
mA Output
20 mA = 20.000 m 3/t
Back Select >
Minimum Flow
0.177 m 3/h
Back Select >
Flow
m3/sec
l/sec
l/min
l/h
m3/h
ft3/h
MGD
GPM
Back Select OK
Flow Forward
mA Output
20 mA = 20.000 m 3/t
Back Select >
(4mA = 0 Flow)
Flow Reverse
mA Output
4 mA = 20.000 m 3/t
20 mA = -20.000
Back Select >
(12mA = 0 Flow, +4mA = -
20mA)
Forward & rev. (12mA=0)
mA Output
4 mA = 0.00 m 3/t
20 mA = 20.000 m 3/t
Back Select >
(4mA = 0 Flow)
Forward & rev.
(4 mA=0)
Converter Setup
Minimum Flow
Averaging
Units
mA Output
R Totalizer Forward
R Totalizer Reverse
R Totalizer Sum
NR Totalizer Forward
NR Totalizer Reverse
NR Totalizer Sum
Batch Counter 1
Batch Counter 2
High Flow
Low Flow
Flow Direction
Empty Pipe
Status
Service Menu
Back Select OK
24h Flow Not in use
R Totalizer Forward
Electro-mechanical Relay
Opto Relay
Display only
Back Select OK
On-time
00100 mSec
Back Select >
Totalizer Forward Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
Electro-mechanical Relay Opto Relay Display only Electro-mechanical Relay Opto Relay Display only
R Totalizer Reverse
Electro-mechanical Relay
Opto Relay
Display only
Back Select OK
Volume between Pulses
01.00000 m 3
Back Select >
Totalizer Forward Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
Totalizer Forward Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
Reset with Digital Input
Yes
No
Back Select OK
On-time
00010 Sec
Back Select >
Volume between Pulses
01.00000 m 3
Back Select >
Reset with Digital Input
Yes
No
Back Select OK
Reset with Digital Input
Yes
No
Back Select OK
On-time
00100 mSec
Back Select >
Totalizer Forward Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
Volume between Pulses
01.00000 m 3
Back Select >
Totalizer Forward Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
Totalizer Forward Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
Reset with Digital Input
Yes
No
Back Select OK
On-time
00100 mSec
Back Select >
Volume between Pulses
01.00000 m 3
Back Select >
Reset with Digital Input
Yes
No
Back Select OK
Reset with Digital Input
Yes
No
Back Select OK
R Totalizer Sum
Totalizer Forward Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
Reset with Digital Input
Yes
No
Back Select OK
NR Totalizer Forward Batch Counter 1
NR Totalizer Reverse
Reseting the
Batch Counter 1
Automatic
Manually
Adaptive
Back Select OK
Electro-mechanical Relay
Opto Relay
Not in use
Back Select OK
Electro-mechanical Relay Opto Relay
Number of
preSelected (Units)
00.002778 m 3
Back Select >
Not in use
Totalizer Forward Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
Totalizer Reverse Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
NR Totalizer Sum
Totalizer total Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
Batch Counter 1 Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
Pause with Digital Input
Yes
No
Back Select OK
Adaptive
Maximum Correction
20%
Back Select >
Reset Batch Error
Yes
No
Back Select OK
Automatic
Batch Counter 1 Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
Pause with Digital Input
Yes
No
Back Select OK
Reseting the
Batch Counter 1
Automatic
Manually
Adaptive
Back Select OK
On-time
00100 mSec
Back Select >
Number of
preselected (Units)
00.002778 m 3
Back Select >
Number of
preSelected (Units)
00.002778 m 3
Back Select >
Manually
Batch Counter 2
Reseting the
Batch Counter 2
Automatic
Manually
Adaptive
Back Select OK
Electro-mechanical Relay
Opto Relay
Not in use
Back Select OK
Electro-mechanical Relay Opto Relay
Number of
preselected (Units)
00.002778 m 3
Back Select >
Not in use
Batch Counter 2 Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
Pause with Digital Input
Yes
No
Back Select OK
Adaptive
Maximum Correction
20%
Back Select >
Reset Batch Error
Yes
No
Back Select OK
Automatic
Batch Counter 2 Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
Pause with Digital Input
Yes
No
Back Select OK
Reseting the
Batch Counter 2
Automatic
Manually
Adaptive
Back Select OK
On-time
00100 mSec
Back Select >
Number of
preselected (Units)
00.02778m 3
Back Select >
Number of
preSelected (Units)
00.002778 m 3
Back Select >
Manually
High Flow
ON at Flow
10.000 m 3/h
Back Select >
Relay Function
NO
NC
Back Select >
OFF at Flow
9.800 m 3/h
Back Select >
Low Flow
Electro-mechanical Relay
Opto Relay
Display only
Not in use
Back Select OK
Delay
00010 Sec
Back Select OK
Electro-mechanical Relay
Opto Relay
Display only
Not in use
Back Select OK
Electro-mechanical Relay Opto Relay Display only
ON at Flow
10.000 m3/h
Back Select >
OFF at Flow
9.800 m3/h
Back Select >
ON at Flow
10.000 m3/h
Back Select >
OFF at Flow
9.800 m3/h
Back Select >
Delay
00010 Sec
Back Select OK
Delay
00010 Sec
Back Select OK
ON at Flow
176,4 m3/h
Back Select >
Relay Function
NO
NC
Back Select >
Off at Flow
170,0 m3/h
Back Select >
Delay
00010 Sec
Back Select >
Electro-mechanical Relay Opto Relay Display only
ON at Flow
176,4 m3/h
Back Select >
Off at Flow
170,0 m3/h
Back Select >
ON at Flow
176,4 m3/h
Back Select >
Off at Flow
170,0 m3/h
Back Select >
Delay
00010 Sec
Back Select >
Delay
00010 Sec
Back Select >
Relay Function
NO
NC
Back Select >
Relay Function
NO
NC
Back Select >
Relay Function
NO
NC
Back Select >
Relay Function
NO
NC
Back Select >
Flow Direction
Electro-mechanical Relay
Opto Relay
Display only
Not in use
Back Select OK
Electro-mechanical Relay Opto Relay Display only
Relay Function
NO
NC
Back Select OK
Empty Pipe
Electro-mechanical Relay
Opto Relay
Display only
Not in use
Back Select OK
Delay
00010 Sec
Back Select >
Delay
00010 Sec
Back Select >
Delay
00010 Sec
Back Select >
Electro-mechanical Relay Opto Relay Display only
Relay Function
NO
NC
Back Select OK
Delay
00010 Sec
Back Select >
Delay
00010 Sec
Back Select >
Delay
00010 Sec
Back Select >
Service Menu
Sensor Calibration Code
Converter SW Ver.
Product Data
Reset Counter Time
Internal Meas. & Cal.
Minimum Velocity
Calibrate Flow now
Calibrate Volume
Calibrate mA
Test Velocity
Freeze Coil
Read Event Log
Back on Stock
Back Select OK
OK
Relay Function
NO
NC
Back Select >
Relay Function
NO
NC
Back Select >
Relay Function
NO
NC
Back Select >
Relay Function
NO
NC
Back Select >
Status
DO1 Not in use
DO2 R Totalizer Forward
DI R Totalizer Forward
mA output 6.250 mA
Back Select OK
Password
Specify Main Screen Factory Settings Data Logger Set Sensor Name Display Setup
Converter Setup
Main Menu
.
.
Service Menu
.
Converter Setup
Back Select OK
Converter Setup
Back Select OK
Converter Setup
Back Select OK
Type Password
00000
Back Select >
Converter Setup Menu Overview
Gf-2
GB MagFlux Manual 0808
Electromagnetic Flow Meter
Averaging Units mA Output
Minimum Flow
Averaging
0010 sec
Back Select >
Flow Forward
Flow Reverse
Forward & rev. (12mA=0)
Forward & rev. (4 mA=0)
Not in use
Back Select OK
mA Output
20 mA = 20.000 m 3/t
Back Select >
Minimum Flow
0.177 m 3/h
Back Select >
Flow
m3/sec
l/sec
l/min
l/h
m3/h
ft3/h
MGD
GPM
Back Select OK
Flow Forward
mA Output
20 mA = 20.000 m 3/t
Back Select >
(4mA = 0 Flow)
Flow Reverse
mA Output
4 mA = 20.000 m 3/t
20 mA = -20.000
Back Select >
(12mA = 0 Flow, +4mA = -
20mA)
Forward & rev. (12mA=0)
mA Output
4 mA = 0.00 m3/t
20 mA = 20.000 m 3/t
Back Select >
(4mA = 0 Flow)
Forward & rev.
(4 mA=0)
Converter Setup
Minimum Flow
Averaging
Units
mA Output
R Totalizer Forward
R Totalizer Reverse
R Totalizer Sum
NR Totalizer Forward
NR Totalizer Reverse
NR Totalizer Sum
Batch Counter 1
Batch Counter 2
High Flow
Low Flow
Flow Direction
Empty Pipe
Status
Service Menu
Back Select OK
Converter Setup
24h Flow Not in use
R Totalizer Forward
Electro-mechanical Relay
Opto Relay
Display only
Back Select OK
On-time
00100 mSec
Back Select >
Totalizer Forward Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
Electro-mechanical Relay Opto Relay Display only Electro-mechanical Relay Opto Relay Display only
R Totalizer Reverse
Electro-mechanical Relay
Opto Relay
Display only
Back Select OK
Volume between Pulses
01.00000 m 3
Back Select >
Totalizer Forward Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
Totalizer Forward Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
Reset with Digital Input
Yes
No
Back Select OK
On-time
00010 Sec
Back Select >
Volume between Pulses
01.00000 m 3
Back Select >
Reset with Digital Input
Yes
No
Back Select OK
Reset with Digital Input
Yes
No
Back Select OK
On-time
00100 mSec
Back Select >
Totalizer Forward Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
Volume between Pulses
01.00000 m 3
Back Select >
Totalizer Forward Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
Totalizer Forward Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
Reset with Digital Input
Yes
No
Back Select OK
On-time
00100 mSec
Back Select >
Volume between Pulses
01.00000 m 3
Back Select >
Reset with Digital Input
Yes
No
Back Select OK
Reset with Digital Input
Yes
No
Back Select OK
R Totalizer Sum
Totalizer Forward Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
Reset with Digital Input
Yes
No
Back Select OK
NR Totalizer Forward Batch Counter 1
NR Totalizer Reverse
Reseting the
Batch Counter 1
Automatic
Manually
Adaptive
Back Select OK
Electro-mechanical Relay
Opto Relay
Not in use
Back Select OK
Electro-mechanical Relay Opto Relay
Number of
preSelected (Units)
00.002778 m 3
Back Select >
Not in use
Totalizer Forward Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
Totalizer Reverse Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
NR Totalizer Sum
Totalizer total Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
Batch Counter 1 Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
Pause with Digital Input
Yes
No
Back Select OK
Adaptive
Maximum Correction
20%
Back Select >
Reset Batch Error
Yes
No
Back Select OK
Automatic
Batch Counter 1 Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
Pause with Digital Input
Yes
No
Back Select OK
Reseting the
Batch Counter 1
Automatic
Manually
Adaptive
Back Select OK
On-time
00100 mSec
Back Select >
Number of
preselected (Units)
00.002778 m 3
Back Select >
Number of
preSelected (Units)
00.002778 m 3
Back Select >
Manually
Batch Counter 2
Reseting the
Batch Counter 2
Automatic
Manually
Adaptive
Back Select OK
Electro-mechanical Relay
Opto Relay
Not in use
Back Select OK
Electro-mechanical Relay Opto Relay
Number of
preselected (Units)
00.002778 m 3
Back Select >
Not in use
Batch Counter 2 Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
Pause with Digital Input
Yes
No
Back Select OK
Adaptive
Maximum Correction
20%
Back Select >
Reset Batch Error
Yes
No
Back Select OK
Automatic
Batch Counter 2 Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
Pause with Digital Input
Yes
No
Back Select OK
Reseting the
Batch Counter 2
Automatic
Manually
Adaptive
Back Select OK
On-time
00100 mSec
Back Select >
Number of
preselected (Units)
00.02778m 3
Back Select >
Number of
preSelected (Units)
00.002778 m 3
Back Select >
Manually
High Flow
ON at Flow
10.000 m 3/h
Back Select >
Relay Function
NO
NC
Back Select >
OFF at Flow
9.800 m 3/h
Back Select >
Low Flow
Electro-mechanical Relay
Opto Relay
Display only
Not in use
Back Select OK
Delay
00010 Sec
Back Select OK
Electro-mechanical Relay
Opto Relay
Display only
Not in use
Back Select OK
Electro-mechanical Relay Opto Relay Display only
ON at Flow
10.000 m3/h
Back Select >
OFF at Flow
9.800 m3/h
Back Select >
ON at Flow
10.000 m3/h
Back Select >
OFF at Flow
9.800 m3/h
Back Select >
Delay
00010 Sec
Back Select OK
Delay
00010 Sec
Back Select OK
ON at Flow
176,4 m3/h
Back Select >
Relay Function
NO
NC
Back Select >
Off at Flow
170,0 m3/h
Back Select >
Delay
00010 Sec
Back Select >
Electro-mechanical Relay Opto Relay Display only
ON at Flow
176,4 m3/h
Back Select >
Off at Flow
170,0 m3/h
Back Select >
ON at Flow
176,4 m3/h
Back Select >
Off at Flow
170,0 m3/h
Back Select >
Delay
00010 Sec
Back Select >
Delay
00010 Sec
Back Select >
Relay Function
NO
NC
Back Select >
Relay Function
NO
NC
Back Select >
Relay Function
NO
NC
Back Select >
Relay Function
NO
NC
Back Select >
Flow Direction
Electro-mechanical Relay
Opto Relay
Display only
Not in use
Back Select OK
Electro-mechanical Relay Opto Relay Display only
Relay Function
NO
NC
Back Select OK
Empty Pipe
Electro-mechanical Relay
Opto Relay
Display only
Not in use
Back Select OK
Delay
00010 Sec
Back Select >
Delay
00010 Sec
Back Select >
Delay
00010 Sec
Back Select >
Electro-mechanical Relay Opto Relay Display only
Relay Function
NO
NC
Back Select OK
Delay
00010 Sec
Back Select >
Delay
00010 Sec
Back Select >
Delay
00010 Sec
Back Select >
Service Menu
Sensor Calibration Code
Converter SW Ver.
Product Data
Reset Counter Time
Internal Meas. & Cal.
Minimum Velocity
Calibrate Flow now
Calibrate Volume
Calibrate mA
Test Velocity
Freeze Coil
Read Event Log
Back on Stock
Back Select OK
OK
Relay Function
NO
NC
Back Select >
Relay Function
NO
NC
Back Select >
Relay Function
NO
NC
Back Select >
Relay Function
NO
NC
Back Select >
Status
DO1 Not in use
DO2 R Totalizer Forward
DI R Totalizer Forward
mA output 6.250 mA
Back Select OK
Password
Specify Main Screen Factory Settings Data Logger Set Sensor Name Display Setup
Converter Setup
Main Menu
.
.
Service Menu
.
Converter Setup
Back Select OK
Converter Setup
Back Select OK
Converter Setup
Back Select OK
Type Password
00000
Back Select >
Converter Setup Menu Overview
Gf-2
GB MagFlux Manual 0808
Electromagnetic Flow Meter
Averaging Units mA Output
Minimum Flow
Averaging
0010 sec
Back Select >
Flow Forward
Flow Reverse
Forward & rev. (12mA=0)
Forward & rev. (4 mA=0)
Not in use
Back Select OK
mA Output
20 mA = 20.000 m 3/t
Back Select >
Minimum Flow
0.177 m 3/h
Back Select >
Flow
m3/sec
l/sec
l/min
l/h
m3/h
ft3/h
MGD
GPM
Back Select OK
Flow Forward
mA Output
20 mA = 20.000 m 3/t
Back Select >
(4mA = 0 Flow)
Flow Reverse
mA Output
4 mA = 20.000 m 3/t
20 mA = -20.000
Back Select >
(12mA = 0 Flow, +4mA = -
20mA)
Forward & rev. (12mA=0)
mA Output
4 mA = 0.00 m3/t
20 mA = 20.000 m 3/t
Back Select >
(4mA = 0 Flow)
Forward & rev.
(4 mA=0)
Converter Setup
Minimum Flow
Averaging
Units
mA Output
R Totalizer Forward
R Totalizer Reverse
R Totalizer Sum
NR Totalizer Forward
NR Totalizer Reverse
NR Totalizer Sum
Batch Counter 1
Batch Counter 2
High Flow
Low Flow
Flow Direction
Empty Pipe
Status
Service Menu
Back Select OK
Converter Setup
24h Flow Not in use
R Totalizer Forward
Electro-mechanical Relay
Opto Relay
Display only
Back Select OK
On-time
00100 mSec
Back Select >
Totalizer Forward Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
Electro-mechanical Relay Opto Relay Display only Electro-mechanical Relay Opto Relay Display only
R Totalizer Reverse
Electro-mechanical Relay
Opto Relay
Display only
Back Select OK
Volume between Pulses
01.00000 m 3
Back Select >
Totalizer Forward Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
Totalizer Forward Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
Reset with Digital Input
Yes
No
Back Select OK
On-time
00010 Sec
Back Select >
Volume between Pulses
01.00000 m 3
Back Select >
Reset with Digital Input
Yes
No
Back Select OK
Reset with Digital Input
Yes
No
Back Select OK
On-time
00100 mSec
Back Select >
Totalizer Forward Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
Volume between Pulses
01.00000 m 3
Back Select >
Totalizer Forward Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
Totalizer Forward Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
Reset with Digital Input
Yes
No
Back Select OK
On-time
00100 mSec
Back Select >
Volume between Pulses
01.00000 m 3
Back Select >
Reset with Digital Input
Yes
No
Back Select OK
Reset with Digital Input
Yes
No
Back Select OK
R Totalizer Sum
Totalizer Forward Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
Reset with Digital Input
Yes
No
Back Select OK
NR Totalizer Forward Batch Counter 1
NR Totalizer Reverse
Reseting the
Batch Counter 1
Automatic
Manually
Adaptive
Back Select OK
Electro-mechanical Relay
Opto Relay
Not in use
Back Select OK
Electro-mechanical Relay Opto Relay
Number of
preSelected (Units)
00.002778 m 3
Back Select >
Not in use
Totalizer Forward Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
Totalizer Reverse Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
NR Totalizer Sum
Totalizer total Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
Batch Counter 1 Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
Pause with Digital Input
Yes
No
Back Select OK
Adaptive
Maximum Correction
20%
Back Select >
Reset Batch Error
Yes
No
Back Select OK
Automatic
Batch Counter 1 Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
Pause with Digital Input
Yes
No
Back Select OK
Reseting the
Batch Counter 1
Automatic
Manually
Adaptive
Back Select OK
On-time
00100 mSec
Back Select >
Number of
preselected (Units)
00.002778 m 3
Back Select >
Number of
preSelected (Units)
00.002778 m 3
Back Select >
Manually
Batch Counter 2
Reseting the
Batch Counter 2
Automatic
Manually
Adaptive
Back Select OK
Electro-mechanical Relay
Opto Relay
Not in use
Back Select OK
Electro-mechanical Relay Opto Relay
Number of
preselected (Units)
00.002778 m 3
Back Select >
Not in use
Batch Counter 2 Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
Pause with Digital Input
Yes
No
Back Select OK
Adaptive
Maximum Correction
20%
Back Select >
Reset Batch Error
Yes
No
Back Select OK
Automatic
Batch Counter 2 Unit
l
hl
kl
m3
ft3
gal
MG
Back Select OK
Pause with Digital Input
Yes
No
Back Select OK
Reseting the
Batch Counter 2
Automatic
Manually
Adaptive
Back Select OK
On-time
00100 mSec
Back Select >
Number of
preselected (Units)
00.02778m 3
Back Select >
Number of
preSelected (Units)
00.002778 m 3
Back Select >
Manually
High Flow
ON at Flow
10.000 m 3/h
Back Select >
Relay Function
NO
NC
Back Select >
OFF at Flow
9.800 m 3/h
Back Select >
Low Flow
Electro-mechanical Relay
Opto Relay
Display only
Not in use
Back Select OK
Delay
00010 Sec
Back Select OK
Electro-mechanical Relay
Opto Relay
Display only
Not in use
Back Select OK
Electro-mechanical Relay Opto Relay Display only
ON at Flow
10.000 m3/h
Back Select >
OFF at Flow
9.800 m3/h
Back Select >
ON at Flow
10.000 m3/h
Back Select >
OFF at Flow
9.800 m3/h
Back Select >
Delay
00010 Sec
Back Select OK
Delay
00010 Sec
Back Select OK
ON at Flow
176,4 m3/h
Back Select >
Relay Function
NO
NC
Back Select >
Off at Flow
170,0 m3/h
Back Select >
Delay
00010 Sec
Back Select >
Electro-mechanical Relay Opto Relay Display only
ON at Flow
176,4 m3/h
Back Select >
Off at Flow
170,0 m3/h
Back Select >
ON at Flow
176,4 m3/h
Back Select >
Off at Flow
170,0 m3/h
Back Select >
Delay
00010 Sec
Back Select >
Delay
00010 Sec
Back Select >
Relay Function
NO
NC
Back Select >
Relay Function
NO
NC
Back Select >
Relay Function
NO
NC
Back Select >
Relay Function
NO
NC
Back Select >
Flow Direction
Electro-mechanical Relay
Opto Relay
Display only
Not in use
Back Select OK
Electro-mechanical Relay Opto Relay Display only
Relay Function
NO
NC
Back Select OK
Empty Pipe
Electro-mechanical Relay
Opto Relay
Display only
Not in use
Back Select OK
Delay
00010 Sec
Back Select >
Delay
00010 Sec
Back Select >
Delay
00010 Sec
Back Select >
Electro-mechanical Relay Opto Relay Display only
Relay Function
NO
NC
Back Select OK
Delay
00010 Sec
Back Select >
Delay
00010 Sec
Back Select >
Delay
00010 Sec
Back Select >
Service Menu
Sensor Calibration Code
Converter SW Ver.
Product Data
Reset Counter Time
Internal Meas. & Cal.
Minimum Velocity
Calibrate Flow now
Calibrate Volume
Calibrate mA
Test Velocity
Freeze Coil
Read Event Log
Back on Stock
Back Select OK
OK
Relay Function
NO
NC
Back Select >
Relay Function
NO
NC
Back Select >
Relay Function
NO
NC
Back Select >
Relay Function
NO
NC
Back Select >
Status
DO1 Not in use
DO2 R Totalizer Forward
DI R Totalizer Forward
mA output 6.250 mA
Back Select OK
Password
Specify Main Screen Factory Settings Data Logger Set Sensor Name Display Setup
Converter Setup
Main Menu
.
.
Service Menu
.
Converter Setup
Back Select OK
Converter Setup
Back Select OK
Converter Setup
Back Select OK
Type Password
00000
Back Select >
Converter Setup Menu Overview
Gf-2
...
Sensor Calibration Code
|
Back Select >
S/N not entered
Set Flow Direction
Follow Arrow A
Follow Arrow B
Back Select OK
MagFlux1
Flow 0.00 m 3/h
FTot 00.000 m 3
Select Setup
Service Menu
Sensor Calibration Code
Converter SW Ver.
Product Data
Reset Counter Time
Internal Meas. & Cal.
Minimum Velocity
Calibrate Flow now
Calibrate Volume
Calibrate mA
Test Velocity
Freeze Coil
Read Event Log
Back on Stock
Back Select OK
Set Flow Direction
Follow Arrow A
Follow Arrow B
Back Select OK
Sensor Calibration Code
Sensor Calibration Code
dw5uq4
Back Select OK
Sensor Calibration Code
A B
A B
Sensor Calibration Code
|
Back Select >
S/N not entered
Set Flow Direction
Follow Arrow A
Follow Arrow B
Back Select OK
MagFlux1
Flow 0.00 m 3/h
FTot 00.000 m 3
Select Setup
Service Menu
Sensor Calibration Code
Converter SW Ver.
Product Data
Reset Counter Time
Internal Meas. & Cal.
Minimum Velocity
Calibrate Flow now
Calibrate Volume
Calibrate mA
Test Velocity
Freeze Coil
Read Event Log
Back on Stock
Back Select OK
Set Flow Direction
Follow Arrow A
Follow Arrow B
Back Select OK
Sensor Calibration Code
Sensor Calibration Code
dzzwjrgl
Back Select OK
Sensor Calibration Code
A B
A B
Sensor Label
MJK Automation
Blokken 9
DK-3460 Birkerød
Denmark
Tel +45 45 56 06 56
www.mjk.com