P-250
13
Effect Parameter List / Liste der Effektparameter / Liste
des paramètres d’effets / Lista de parámetros de efectos
Items with a dot indicator (
●
) in the Control column are parameters that can be controlled via assignable controllers.
• Note that this is applicable to the Variation effects (while Insertion is selected) and to the Insertion effects.
HALL1, HALL2
ROOM1, ROOM2, ROOM3
STAGE1, STAGE2
PLATE (reverb, variation, insertion block)
DELAY L, C, R (variation, insertion block)
DELAY L, R (variation, insertion block)
ECHO (variation, insertion block)
CROSS DELAY (variation, insertion block)
EARLY REF1, EARLY REF2 (variation, insertion block)
GATE REVERB
REVERSE GATE (variation, insertion block)
WHITE ROOM
TUNNEL
CANYON
BASEMENT (reverb, variation, insertion block)
No. Parameter Display Value See Table Control
1Reverb Time 0.3-30.0s 0-69 table#4
2Diffusion 0-10 0-10
3Initial Delay 0.1mS-99.3ms 0-63 table#5
4 HPF Cutoff Thru-8.0kHz 0-52 table#3
5LPF Cutoff 1.0k-Thru 34-60 table#3
6
7
8
9
10 Dry/Wet D63>W - D=W - D<W63 1-127
●
11 Rev Delay 0.1mS-99.3mS 0-63 table#5
12 Density 0-4 (reverb, variation block) 0-4
0-2 (insertion block) 0-2
13 Er/Rev Balance E63>R - E=R - E<R63 1-127
14 High Damp 0.1-1.0 1-10
15 Feedback Level –63-+63 1-127
16
No. Parameter Display Value See Table Control
1Lch Delay 0.1-1638.3ms 1-16383
2Rch Delay 0.1-1638.3ms 1-16383
3Cch Delay 0.1-1638.3ms 1-16383
4Feedback Delay 0.1-1638.3ms 1-16383
5Feedback Level –63-+63 1-127
6 Cch Level 0-127 0-127
7High Damp 0.1-1.0 1-10
8
9
10 Dry/Wet D63>W - D=W - D<W63 1-127
●
11
12
13 EQ Low Frequency 32Hz-2.0kHz 4-40 table#3
14 EQ Low Gain –12-+12dB 52-76
15 EQ High Frequency 500Hz-16.0kHz 28-58 table#3
16 EQ High Gain –12-+12dB 52-76
No. Parameter Display Value See Table Control
1Lch Delay 0.1-1638.3ms 1-16383
2Rch Delay 0.1-1638.3ms 1-16383
3Feedback Delay 1 0.1-1638.3ms 1-16383
4Feedback Delay 2 0.1-1638.3ms 1-16383
5Feedback Level –63-+63 1-127
6High Damp 0.1-1.0 1-10
7
8
9
10 Dry/Wet D63>W - D=W - D<W63 1-127
●
11
12
13 EQ Low Frequency 32Hz-2.0kHz 4-40 table#3
14 EQ Low Gain –12-+12dB 52-76
15 EQ High Frequency 500Hz-16.0kHz 28-58 table#3
16 EQ High Gain –12-+12dB 52-76
No. Parameter Display Value See Table Control
1Lch Delay1 0.1-1486.0ms 1-14860
2 Lch Feedback
Level –63-+63 1-127
3Rch Delay1 0.1-1486.0ms 1-14860
4 Rch Feedback
Level –63-+63 1-127
5High Damp 0.1-1.0 1-10
6Lch Delay2 0.1-1486.0ms 1-14860
7Rch Delay2 0.1-1486.0ms 1-14860
8 Delay2 Level 0-127 0-127
9
10 Dry/Wet D63>W - D=W - D<W63 1-127
●
11
12
13 EQ Low Frequency 32Hz-2.0kHz 4-40 table#3
14 EQ Low Gain –12-+12dB 52-76
15 EQ High Frequency 500Hz-16.0kHz 28-58 table#3
16 EQ High Gain –12-+12dB 52-76
No. Parameter Display Value See Table Control
1L->R Delay 0.1-1486.0ms 1-14860
2R->L Delay 0.1-1486.0ms 1-14860
3Feedback Level –63-+63 1-127
4Input Select L, R, L&R 0-2
5High Damp 0.1-1.0 1-10
6
7
8
9
10 Dry/Wet D63>W - D=W - D<W63 1-127
●
11
12
13 EQ Low Frequency 32Hz-2.0kHz 4-40 table#3
14 EQ Low Gain –12-+12dB 52-76
15 EQ High Frequency 500Hz-16.0kHz 28-58 table#3
16 EQ High Gain –12-+12dB 52-76
No. Parameter Display Value See Table Control
1Type S-H, L-H, Rdm, Rvs, Plt, Spr 0-5
2Room Size 0.1-7.0 0-44 table#6
3Diffusion 0-10 0-10
4Initial Delay 0.1mS-200.0ms 0-127 table#5
5Feedback Level –63-+63 1-127
6 HPF Cutoff Thru-8.0kHz 0-52 table#3
7LPF Cutoff 1.0k-Thru 34-60 table#3
8
9
10 Dry/Wet D63>W - D=W - D<W63 1-127
●
11 Liveness 0-10 0-10
12 Density 0-3 0-3
13 High Damp 0.1-1.0 1-10
14
15
16
No. Parameter Display Value See Table Control
1Type TypeA, TypeB 0-1
2Room Size 0.1-7.0 0-44 table#6
3Diffusion 0-10 0-10
4Initial Delay 0.1mS-200.0ms 0-127 table#5
5Feedback Level –63-+63 1-127
6 HPF Cutoff Thru-8.0kHz 0-52 table#3
7LPF Cutoff 1.0k-Thru 34-60 table#3
8
9
10 Dry/Wet D63>W - D=W - D<W63 1-127
●
11 Liveness 0-10 0-10
12 Density 0-3 0-3
13 High Damp 0.1-1.0 1-10
14
15
16
No. Parameter Display Value See Table Control
1Reverb Time 0.3-30.0s 0-69 table#4
2Diffusion 0-10 0-10
3Initial Delay 0.1mS-99.3ms 0-63 table#5
4 HPF Cutoff Thru-8.0kHz 0-52 table#3
5LPF Cutoff 1.0k-Thru 34-60 table#3
6Width 0.5-10.2m 0-37 table#11
7Height 0.5-20.2m 0-73 table#11
8Depth 0.5-30.2m 0-104 table#11
9Wall Vary 0-30 0-30
10 Dry/Wet D63>W - D=W - D<W63 1-127
●
11 Rev Delay 0.1mS-99.3mS 0-63 table#5
12 Density 0-4 0-4
13 Er/Rev Balance E63>R - E=R - E<R63 1-127
14 High Damp 0.1-1.0 1-10
15 Feedback Level –63-+63 1-127
16