Yolink YS7904-UC Operation manual

Water Leak Sensor 2
YS7904-UC
Installaon & User Guide
Rev 1.0

Contents
In the Box ·············································································1
Introducon ·········································································2
Set Up ··················································································5
Installaon ···········································································7
Using the YoLink App ···························································14
················About YoLink Control ······························ ············23
·27Maintenance ···················· ················································
Specificaons ········································ ·····30························
Troubleshoong ·································································31
Warning ·············································································32
Customer Service & Warranty ··············································34

In the Box
1
A. Water Leak Sensor
B. Sensor Cable
C. Mounng Hook
D. Quick Start Guide
C.
A.
D.
B.

Introducon
The YoLink Water Leak Sensor 2 is a smart water detector, that can detect the presence or absence
of water, and can either
2
In water le ak dete c on mo de , p r o vi de ea rl y wa rn in g o f wate r l e a k s o r fl o o d i n g b efore
cos t l y p ro pe rt y d am age oc cu rs
In water level detecon mode, provide nofica on of no water, for super vision of water
supplies for pets, house plants, greenhouses, horculture/agricult ure, and so on
Depending on your applicaon for the sensor, a choice of cable is required. The sensor cable
(included) can be used for both detecon modes, but it is ideal for water leak detecon mode.
The water sensor probe (sold separately) is ideal for water level detecon mode
Cable Types: (see illustraons, next page)
The sensor cable detects water along the length of the cable, while the water sensor probe
detects water only at the probe at the end of the cable
Depending on the water leak or level detecon mode, the sensor LED will blink red and the
sensor sounder will emit loud alarm tones. Noficaons will be sent to you via the YoLink app
(available noficaons types are: email, text/SMS and push/banner noficaons on your Apple
or Android smartphone, each configurable in app sengs)
Operaon & Noficaons:

3
Phono Jack
Used for extending sensor
cable
Status LED
* Not visible while there is no
operaon with the SET buon
or while device is in normal
monitoring status
Sensor Cable
Used for water detecon
SET Buon
Phono Plug
Detector Probe
Used for water detecon
or low water level warning
Phono Plug
Mounng Hole
OR You can Replace the Sensor Cable with a
Water Sensor Probe Instead
(Oponal, Sold Separately)
Alarm Tones
One Beep
Device power-up / buon pressed
Two Beeps
Warning
(Two beeps every 2 seconds for
the first minute. Two beeps every
5 seconds for the next 12 hours.
Sustaining two beeps once a
minute aer 12 hours)
Phono Jack
Used for sensor cable
extension
Wall-Mounng Slot
Baery Compartment
Includes two AAA
non-rechargeable
baeries

The LED light indicates the current status of the sensor:
4
Blinking Green
Connecng to Cloud
Fast Blinking Green
Establishing Connecon with YoLink System (YoLink Control)
Slow Blinking Green
Updang
Fast Blinking Red
Removing Connecon to YoLink System (YoLink Control)
Blinking Red Once
Leak or Flooding Warning (water leak detecon mode)
Water Exhausted Warning (water level detecon mode)
Blinking Red And Green Alternately
to Factory DefaultRestoring

Set Up
Set Up - First-Time YoLink Users (Exisng users proceed to Add Device, next page)
* Get ready: your W LeakTo set up and use ater Sensor 2, you will need an Apple iPhone or tablet that is iOS 9.0 or higher, or an Android phone
or tablet that is Android 4.4 or higher
Follow the steps below to set up your Water Leak Sensor 2 via the YoLink app
Download YoLink app through Apple App Store or Google Play Store
Log in or create a new account if required
Download, and log
in to YoLink app
1
* Make sure your hub is connected to the
internet (green LED indicator is
blinking, blue LED indicator is
always on)
Set up YoLink Hub
2
YoLink Hub is required to set up your Water Leak Sensor 2. Please set up your YoLink Hub first
(refer to YoLink Hub manual)
* Ethernet patch cable (included) to your network
(router, switch, etc.), recommended, but oponal.
Otherwise connect your Hub to your home Wi-Fi
network. Refer to the Hub set up manual for more
informaon:
YS1603-UC_User Guide 5
Power
Adapter
Hub
SET

Add Device
Press the SET buon (on front of sensor) once, the Status LED will blink several mes (red,
then green). The green LED indicates the device is online and ready to use
Tap “ ” buon, then scan QR Code on the device
Press the SET buon
(on front of sensor) once
2
SET Buon
* Status LED will blink
red once, then green several
mes(If device is working well
with connecon to the cloud, it will
blink red once only)
Tap “ ” buon
to add devices
1
6

Installaon
The mounng hook is very difficult to relocate aer being affixed to the mounng surface. Test
your locaon before affixing the mounng hook to the surface. Use masking or painters sensor
tape to secure the mounng hook to the surface. Once you have the mounng hook temporarily
mounted then hang the sensor on the hook, test out the sensor. With the app in hand, follow the
Device Alerts secon on page to test water warning and warning removed using the app and 17
observing the status of the sensor as shown on the app (Water Warning or Water Warning
Removed). Oponally, you may set up your automaon (e.g. turn off a valve when water is
detected) to funconally test the alert of the sensor - proceed to the following steps for
informaon on creang automaons, then return to this step
Test the Sensor Locaon Before Installaon
This sensor is not waterproof and is designed and intended only for indoor use. Subjecng this
device to outdoor environment condions such as direct sunlight, extreme hot or cold
temperatures, rain, water and/or condensaon can damage the device and will void the warranty
If flooding is a risk mount the sensor at a higher locaon, where it is less likely to get wet (which
may render it non-funconal)
Please refer to device environmental operaon range on page 30. Use this device outside the
recommended ranges at your own risk
7
Avoid allowing the Water Leak Sensor 2 to be exposed to strong impacts or vibraon
Please add the Water Leak Sensor 2 to the YoLink app before installaon

Depending on your applicaon for the sensor, determine the opmal locaon for the sensor
cable (recommended) or water leak probe:
Select Your Sensor Locaon (Water Leak Detecon Mode):
8
Pl a c e t h e ca bl e di rec tl y u n de r t h e p o t en al s o u rc e of a wate r l ea k (for exa m p l e , un de r a d i s hwa sh er o r
water h eate r)
Place th e cable on t h e flo o r at a locaon w here floodin g is possibl e (for example, nex t to a sump p ump o r
sub-gra de d o or in a b a sement)
If pos sible, locate the cable where it will not be disturbe d by foot traffic or pets
As basement floors may be sloped to allow
for drainage of water, for earliest warning
select a locaon that is at a lower point
rather than a higher point on the floor
Suggested Addional Applicaons:
Basement Floors
Under Laundry Machines
Under Dishwashers
Under Refrigerators (w/Ice Machines)
Near Sump Pumps
Under Fish Tanks/Aquariums
Inside Hot Tubs*
Locaons Subject to Freezing Pipes*
Depending on your applicaon for the sensor, determine the opmal locaon for the water
leak probe (recommended) or sensor cable:
Select Your Sensor Locaon (Water Level Detecon Mode):
Place the water le a k probe cable wi t h the probe in t h e wate r, posioned j u st b e l ow the accepta b l e water
level (so that when the water level recedes, an al e r t will be sent)

Clean the installaon area
Remove t h e protecve l ayer o n the
double-sided tape on t h e boo m of
th e ho ok , ho ok Pl ac e th e at th e
pre-determ i n e d loca o n th e n p ress
it fir m l y fo r at least 5 seconds
Begin Installaon
Skip to page 12 if you are using a water
sensor probe instead of a sensor cable
Method A: Sensor Cable Installaon
Insert the sensor cable’s phono plug
into the water leak sensor ’s phono
jack as shown
9

Hang the sensor on the hook through
the wall-mounng slot
Ad ju s t th e s e ns or c a b l e, pl a c e it to
wh ere a l e a k o r fl o o d in g m ay o c c ur,
or w h e re t h e wate r l e vel w il l d ro p
* For the water level monitoring, please do not bend the
sensor cable in the detecon area
10

Sensor cable extension
Ins ert add io nal se nso r ca ble s a s s how n ( red high lig hted por on s of th e s ens or ca bl e are the dete c o n
areas ), if need ed (refer to page 30 for th e exten sio n c a ble sp eci ficao n s)
11

These Tools may be Required
Method B: Water Sensor Probe Installaon Insert the water sensor probe’s phono
plug into the water leak sensor’s phono
jack as shown
12
Double-sided
Mounng Tape
Self-tapping
Screw
OR
Nail
OR
Phillips Screwdriver Hammer

A d j u s t th e w a t e r s e n s o r p r o b e ,
placing it to where a leak or flooding
may occur, or where the water level
will drop
* Do not bend the water sensor probe in the detecon area
You can use a screw or nail or double-sided
mounng tape to mount the detector
probe
Hang the sensor on the hook through
the wall-mounng slot
13

Using the YoLink App
Device page (Water Leak Detecon Mode)
Alert interval
* Set re-noficaon interval
aer a leak or flooding warning
Default is 5 minutes
Device name
* Edit name on Details page
* Water detected
14
Device history
Water detected and cleared
events, logged with date & me
Connecon status
of sensor and Hub
Details
* Tap to go to Details page
(refer to page 16)
Baery level
current baery level
* Shown red if replacement is required
Real-me status:
Normal or water-detected

Device page (Water Level Detecon Mode)
15
Alert interval
* Set re-noficaon interval
aer the water exhausted
warning
Default is 5 minutes
Device history
Water detected and cleared
events, logged with date & me
Connecon status
of sensor and Hub
Details
* Tap to go to Details page
(refer to page 16)
Baery level
current baery level
* Shown red if replacement is required
Device name
* Edit name on Details page
Real-me status:
Normal or water-exhausted
* Water exhausted

Details page
* Aer changing “Alert Interval” and / or “Device Mode” and / or “Beep” sengs, press the device’s SET buon
once, to sync the new sengs to the device. Otherwise, the device will automacally update within 4 hours
(maximum)
16
Beep sound
aer a leak or flooding warning
or water exhausted warning
Rename the device
Choose a room
for device
Device type
Alert sengs
* Enable or disable alerts
Alert interval
* Set re-noficaon interval
aer a leak or flooding warning
or water exhausted warning
Default is 5 minutes
Add / remove
from favorites
Device history
Water detected and
cleared events, logged
with date & me
Device status
* Normal, Warning
Device EUI (unique)
Device SN (unique)
Temperature value
* Updates when:
1. SET buon pressed
2. On a device alert
3. Baeries are replaced
4. Automacally within 4 hours
maximum
Connecon status
of sensor and Hub
Baery level
current baery level
* Shown red if replacement is
required
Firmware version
* ” indicates a “#### ready now
new update is available (refer
to page 27)
Device model
* Tap to delete the device from
your YoLink account
Device mode sengs
* Water Leak Monitor:
water leak detecon mode.
Water Exhausted Monitor:
water level detecon mode

Device Alerts
17
Method A: Sensor Cable
Water Leak Detecon Mode
When a ny po int of se n sor ca b le detect s water, an al e rt no fica on wi l l be se nt , and t h e
sens or statu s will b e sho w n on your Yo Link a pp (s e e page 2 for mo re i n form a o n abo ut
no fi ca o ns)
Note
The default re-noficaon interval aer
a leak or flooding alert is 5 minutes. This
interval may be adjusted in the Details
page (refer to page 16)
Aer a leak or flooding event, please
remove the sensor cable from the sensor
and do not reconnect it unl both the
sensor cable and locaon is dry

Method B: Water Leak Probe
When both ps of the water leak probe are immersed in water, an alert noficaon will be
sent, and the sensor status will be shown on your YoLink app (see page 2 for more informaon
about noficaons)
Note
The default re-noficaon interval aer
a leak or flooding alert is 5 minutes. This
interval may be adjusted in the Details
page (refer to page 16)
Aer a leak or flooding event, please
remove the water sensor probe from
the sensor and do not reconnect it unl
both the water sensor probe and
locaon is dry
18
Table of contents
Other Yolink Accessories manuals

Yolink
Yolink YS7805-UC Operation manual

Yolink
Yolink YS7903-UC User manual

Yolink
Yolink YS7804-UC User manual

Yolink
Yolink YS7201-UC Operation manual

Yolink
Yolink YS6704-UC User manual

Yolink
Yolink YS7903-UC User manual

Yolink
Yolink Plug Mini YS6604-UC User manual

Yolink
Yolink YS7704-UC User manual

Yolink
Yolink YS6602-UC User manual

Yolink
Yolink YS7704-UC User manual