manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. YOODA
  6. •
  7. Transmitter
  8. •
  9. YOODA MAGNETIC Series User manual

YOODA MAGNETIC Series User manual

In order to fully explore available functions of MAGNETIC series please take a moment and read this manual before using the device.
MAGNETIC transmitters are compatible with all YOODA brand devices.
Radio receiver range is a variable value and can differ from declared values depending on conditions in which device
operates. Possible sources of changes in range are building construction, interference caused by other radio transmitters
etc.
UP button
STOP button
DOWN button
L1 timer programming
button/CHANNEL + button
P1 configuration change
button/CHANNEL -
Work mode button
Days of the week
Minutes
Hour
Work mode
Direction of roller
shutter movement
Currently channel
(only 5Rwt)
Discharged
battery message
MAGNETIC_1RwT | MAGNETIC_5RwT
www.sukcesgroup.pl
1
1. General information
2. Detailed description
1. Control:
can control single motor, or a group
of up to 20 motors on each channel
2. Range:
200 meters outdoor,
35 meters indoor
3. Battery:
1 x CR2430
4. Power supply:
3 V
5. Dimensions:
80 x 80 x 14 mm
6. Transmitting power:
10 mW
7. Operating temperature:
from 0°C to 50°C
8. Protection degree:
IP 30
Illustrations (from the top):
Fig. 1. Single-channel MAGNETIC remote control with timer, (MAGNETIC_1RwT)
Fig. 2. 55-channel MAGNETIC remote control with timer, (MAGNETIC_5RwT)
The channel is inactive when its number is flashing. Default channels are active in automation. This applies to
a 5-channel transmitter.
1. Manual work mode (MAN symbol will display): standard mode without using time programming function.
2. Automatic mode (AUTO symbol will display): standard mode with activated automatic work time.
3. Random work mode: mode with random time of activation (+/- 15 minutes difference from programmed time).
Time can be set only when device is in manual working mode.
Longer than 10 seconds pause between series of button clicks during programming will cause device to switch off
from time setting mode.
By pressing work mode button
for about 3 seconds work mode
set to manual mode.
Press and hold L1 button
for about 3 seconds
(hour starts to flash).
Using UP and DOWN
buttons set hour.
By pressing L1 button
switch to minute setting.
Using UP and DOWN
buttons set minute.
By pressing L1 button switch
to current day of the week.
Using UP and DOWN
buttons set current
day of the week.
Press and hold P1 button
for about 3 second to confirm
all the changes.
Pressing ‘L1’ button
will start the clock.
By pressing work mode button
for about 3 seconds
set the manual mode.
By pressing work mode button
for about 3 seconds set the
automatic mode.
By pressing work mode button
for about 3 seconds
set the random mode.
Pressing the programming
button P2 again switches
between modes.
Press work mode button to
change automatic or
random mode.
By pressing ‘L1’ or ‘P1’
choose a channel.
By pressing
‘P1’ button for about 3 seconds
automatic mode is deactivated
Channel number is flashing.
Another pressing ‘P1’ button
for about 3 seconds
will activate automatic mode
Channel displays constantly.
2
3. Activating channels in automatic mode
4. Changing work mode
5. Setting current time
1. The programming button replaces the simultaneous pressing of the work mode button and L1 timer programming
button.
2. Group channel is active when all numbers are selected
4. Estimated battery lifespan is 3 year if the device runs 4 commends a day in average.
5. Batteries should be changed when no channel number is displayed after pressing any button or receiving device stops
reacting to commands.
When replacing the battery, pay attention to the correct polarity
Batteries contain substances that may be hazardous to health and may pollute the environment. Used batteries should
be disposed of properly.
3
1. Difference between automatic time of roller shutter opening and closing cannot be shorter than 32 minutes. In case of
smaller than minimal time difference fault message will appear.
2. Changes to opening and closing time can be done only in automatic mode.
3. Longer than 60 seconds pause between series of button clicks during programming will cause device to switch off
from time setting mode without saving any changes.
4. Group channel needs to chosen for transmitter to control all devices at the same time. That applies to all working
modes.
5. If while setting time of automatic opening or closing ‘--:--‘ symbol appears, it means that this time is not active in
automatic mode.
6. To leave time programming mode without saving any changes press STOP button.
7. To control receivers automatically from all channels set up a group channel
8. Group channel is active when all numbers are selected
The above steps need to be repeated for all five channels during the same programming.
By pressing the work mode
button, we set the automatic
or random mode.
By pressing ‘L1’ button
for approximately 3 seconds.
Opening time will appear.
Press L1 button.
Opening hour starts to flash.
Using UP and DOWN
buttons set hour.
Pressing L1 button switch
to minute settings.
Using UP and DOWN
buttons set minutes.
Pressing work mode button
switch to opening hour
settings.
Using UP and DOWN
buttons set minutes.
Using L1 button
buttons set minutes.
Using UP and DOWN
buttons set minutes.
6. Setting automatic opening and closing time
The above steps need to be
repeated for all opening and
closing hour in every day
of the week.
Pressing P1 configuration change
button confirm the set time
and go to set the hour
on the next day of the week.
After programming press and hold P1
button for about 3 second to confirm
all the changes. Set hour is flashing.
Press simultaneously L1 timer
programming button
and work mode button.
7. Programming first transmitter to R-type motors
4
1. Way of programming first transmitter depends on type of radio receiver. When programming first transmitter please
follow instruction of the device that is going to be controlled by the transmitter.
2. Longer than 5 seconds pause between series of button clicks during programming will cause device to switch off from
programming mode without saving any changes.
3. Programming transmitter using this method will result in deleting receiver memory.
Turn on power supply
or press microswitch
(for 2 sec.) when
power is on.
Motor will make a sound.
Roller shutter will make
an up/down move.
Press simultaneously L1 timer
programming
button and work mode button.
Motor will
make a sound.
or
Roller shutter
will make an
up/down move
and the motor
will make a few
short sounds.
Motor will
make a sound.
Press UP button.

This manual suits for next models

2

Other YOODA Transmitter manuals

YOODA MAGNETIC Deluxe 1Rw User manual

YOODA

YOODA MAGNETIC Deluxe 1Rw User manual

YOODA MAGNETIC PRO YSH User manual

YOODA

YOODA MAGNETIC PRO YSH User manual

YOODA MAGNETIC Deluxe-15Rw User manual

YOODA

YOODA MAGNETIC Deluxe-15Rw User manual

YOODA MAGNETIC-PRO-15Rw YSH User manual

YOODA

YOODA MAGNETIC-PRO-15Rw YSH User manual

YOODA CAMELEO_1RwT Configuration guide

YOODA

YOODA CAMELEO_1RwT Configuration guide

YOODA MAGNETIC PRO YSH User manual

YOODA

YOODA MAGNETIC PRO YSH User manual

YOODA MAGNETIC DELUXE YSH Series User manual

YOODA

YOODA MAGNETIC DELUXE YSH Series User manual

YOODA BESH 1RT User manual

YOODA

YOODA BESH 1RT User manual

Popular Transmitter manuals by other brands

Emerson Rosemount 708 Quick installation guide

Emerson

Emerson Rosemount 708 Quick installation guide

Campbell SAT HDR GOES instruction manual

Campbell

Campbell SAT HDR GOES instruction manual

Dwyer Instruments CDX Series Installation and operating instruction manual

Dwyer Instruments

Dwyer Instruments CDX Series Installation and operating instruction manual

Thies CLIMA 5.4103.10.000 Instructions for use

Thies CLIMA

Thies CLIMA 5.4103.10.000 Instructions for use

Spektrum DX4S instruction manual

Spektrum

Spektrum DX4S instruction manual

Continental Electronics 316F instruction manual

Continental Electronics

Continental Electronics 316F instruction manual

YOKOGAWA Dpharp vigilantplant EJA110A user manual

YOKOGAWA

YOKOGAWA Dpharp vigilantplant EJA110A user manual

GE Security S731DV installation instructions

GE Security

GE Security S731DV installation instructions

LRS T9100 user manual

LRS

LRS T9100 user manual

M-system M5 Series instruction manual

M-system

M-system M5 Series instruction manual

Siemens SITRANS LR560 operating instructions

Siemens

Siemens SITRANS LR560 operating instructions

Data Video HBT-15 instruction manual

Data Video

Data Video HBT-15 instruction manual

Honeywell oneWireless XYR 6000 user manual

Honeywell

Honeywell oneWireless XYR 6000 user manual

Nice ON1FM instructions

Nice

Nice ON1FM instructions

Igema DLT2 Installation and operating instructions

Igema

Igema DLT2 Installation and operating instructions

YOKOGAWA EJA210E user manual

YOKOGAWA

YOKOGAWA EJA210E user manual

Lightware WP-UMX-TPS-TX120-US Black quick start guide

Lightware

Lightware WP-UMX-TPS-TX120-US Black quick start guide

Votronic 5543 manual

Votronic

Votronic 5543 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.