6JOHNSON CONTROLS
FORM 201.21-NM2 (616)
TABLE OF CONTENTS (CONT’D)
Water System ........................................................37
Flow Switch..........................................................37
Temperature Sensor(s)..........................................37
Programmed Options............................................38
Programmed Settings............................................38
Date & Time .........................................................38
Start / Stop ............................................................38
Setpoint & Remote Offset ....................................38
FIRST TIME STARTUP...........................................38
Interlocks ..............................................................38
Unit Switch...........................................................38
Start-Up ................................................................38
Oil Pressure...........................................................38
Refrigerant Flow...................................................39
Loading.................................................................39
Condensor & Fan Rotation...................................39
Suction Super Heat ...............................................39
Sub-Cooling..........................................................39
General Operation.................................................39
SECTION 6 - TECHNICAL DATA
WATER PRESSURE DROP CHARTS ....................40
GLYCOL CORRECTION FACTORS......................41
WATER TEMP. AND FLOWS .................................42
PHYSICAL DATA....................................................44
OPERATING LIMITATIONS AND
SOUND POWER......................................................46
ELECTRICAL DATA...............................................47
ELECTRICAL NOTES ............................................50
ELEMENTARY WIRING DIAGRAM ....................52
CONNECTION DIAGRAM ....................................56
LOCATION LABEL.................................................60
DIMENSIONS..........................................................62
TECHNICAL DATA (CLEARANCES) ...................90
WEIGHT DISTRIBUTION &
ISOLATOR MOUNTING ...................................92
ISOLATOR MOUNTING POSITIONS ...................93
SEISMIC ISOLATOR INSTALLATION .................96
NEOPRENE ISOLATOR POSITION ......................98
1" DEFLECTION ISOLATOR INSTALLATION....99
REFRIGERANT FLOW DIAGRAM.....................101
PROCESS & INSTRUMENTATION
DIAGRAM .............................................................102
COMPONENT LOCATIONS ................................103
EQUIPMENT START-UP CHECK SHEET...........120
Unit Checks (NO power)....................................120
Panel Checks
(Power ON-both system switches OFF).............122
Programmed Values............................................123
Chilled Liquid Setpoint ......................................123
Date/Time, Daily Schedule, & Clock Jumper ....123
Initial Start-Up....................................................124
Check Subcooling & Superheat..........................124
Leak Checking....................................................125
CHILLER ELECTRONIC COMPONENTS..........126
Keypad................................................................126
Display................................................................127
Chiller Control Board .........................................128
Relay Output Boards ..........................................129
VSD (Variable Speed Drive) ..............................129
AC to DC Rectier .............................................129
SCR Trigger Board .............................................130
DC Link Filter ....................................................130
1L Line Inductor .................................................131
AC to DC Inverter ..............................................131
Laminated Bus Structure ....................................131
VSD Logic Board ...............................................132
Control Panel to VSD Communications.............132
IBGT Gate Driver Boards...................................133
Current Transformers..........................................133
DV/DT Output Suppression Network ................134
Flash Tank Feed/Drain Valve Controller ............134
DC Bus Voltage Isolation Board.........................135
Chiller Circuit Breaker .......................................135
Autotransformer..................................................135
CHILLER CONFIGURATION JUMPERS............136
Number of Compressors Conguration Jumpers136
VSD LOGIC TO CHILLER MICROPROCESSOR
BOARD RS-485 COMMUNICATION
CONFIGURATION JUMPERS..............................136
MAX VSD FREQUENCY .....................................137
SECTION 7 - OPERATION
OPERATING CONTROLS ....................................138
BASIC OPERATING SEQUENCE........................140
NUMBER OF COMPRESSORS TO START ........141
General................................................................141
Standard IPLV.....................................................141
Optional Optimized IPLV...................................141
MINIMUM VSD COMPRESSOR
START/STOP FREQUENCY.............................142
Minimum VSD Start Frequency.........................142
Minimum VSD Run Frequency..........................142
ACCELERATION/DECELERATION RATE
WHEN STARTING & STOPPING
COMPRESSORS....................................................143
VSD Acceleration/ Deceleration Rates...............143
STANDARD IPLV CAPACITY CONTROL........144
Fuzzy Logic Control...........................................145
Hot Water Starts..................................................146
Lag Compressor Operation in Load Limiting ....146
OPTIONAL IPLV CAPACITY CONTROL...........147
Fuzzy Logic ........................................................148
Hot Water Starts..................................................149