EPDT-322b
■
Caution
1. Before applying higher pressure fluid to the product, check that no problems have occurred in
equipments on the piping.
* Failure to follow this notice may damage the equipment.
2. Completely discharge fluid from the product and piping before leaving the product not operated for a long
time.
* Failure to follow this notice may cause fo
reign substances and scale inside of the piping and may result
in malfunction of the product.
3. If the product is not operated for a long time, perform test working before starting operation.
8.1 Daily inspection
Check the following items while the system is in operation.
Corrosion or crack on the product
Leakage from the product under normal working pressure (check it visually and aurally).
Leakage from joints between the product and piping.
* Please contact us if any abnormal condition is observed.
8.2 Monthly inspection
1. Check that there is no loose piping at inlet and outlet side of the product. In addition, check that the
cap [11] is fastened securely.
2. Check the operation of the product by raising fluid pressure to the set pressure.
For the AL-32ML and the AL-32TML (closed type with a lever), check the operation, by lifting up the
lever, while differential pressure between the set and inlet pressures is within the range of table 3.
* Please contact us if any abnormal condition is observed.
Table 3. The differential Pressure in which the blow-off inspection by lever operation is possible
ifferential pressure between set and inlet
32-40A 0.6 MPa or less
8.3 Troubleshooting
Leakage detected
visually/aurally at the
outlet *
Foreign substance or scale stuck
on contact surface between the
valve [3] and valve seat [2].
Follow the procedure described in
operate the product and eliminate the foreign
substance and scale.
Please contact us if the trouble does not stop.
Damage on contact surfaces
of the valve [3] and valve seat [2].
The product needs to be disassembled
and its parts need to be replaced.
Please contact us.
Excessive vibration applied to the
piping where the product is installed.
The product should not be used on device
or equipment that vibrates excessively.
e pressure difference between the
set pressure and the normal working
pressure is too small.
Increase the pressure difference. If the
set pressure needs to be readjusted,
please contact us.
The pressure momentarily exceeds
the set pressure because of fluid
pulsation.
In view of fluid pulsation, the set pressure
needs to be raised (readjusted) or the
normal working pressure needs to be
lowered. To raise (readjust) the set
pressure, please contact us.
Fluid flows into the outlet piping.
Change the piping layout to keep the fluid
from flowing into the outlet piping.
Blows at a pressure
lower than the set
pressure.
The product specifications are not
consistent with the use condition.
Check the set pressure indication on the
name plate. If the product is not suitable
for the usage condition, replace it with a
proper one.
The pressure gauge is out of
order.
Calibrate the pressure gauge or replace it
with a new one.
The product does not keep the
accuracy of its set pressure.
The set pressure needs to be readjusted.
Please contact us.
*AL-32 and AL-32ML have allowable valve seat leakage and does not close completely (valve seat
leakage cannot be zero).