MODEL 06206
MARINEWINDTRACKER
INTRODUCTION
TheYOUNGModel06206MarineWindTrackerisacompactwindspeed
and wind direction display. This model has features such as relative
wind angle and NMEA compatibility that make it suitable for shipboard
use.
FEATURES
• 3 digit wind speed display
• 3 digit maximum wind speed or wind direction display
• Multi-color wind direction display with variability display
• Wind speed and direction alarms with delay
• RS-485/NMEA serial connections
• Calibrated 0-5 VDC outputs
• Display brightness control
• 4-20 mA Sensor Inputs
• Luminous front panel markings
PRECAUTIONS
• INDOOR USE ONLY unless placed in approved enclosure.
• Operating temperature range 0-50°C (32-122°F), 0-95% RH.
• Use only recommended power sources; 12-30VDC, 4.5 W.
• Disconnect power when making connections or servicing
sensors.
• MAXIMUM 24 VAC/30 VDC on alarm relay contacts.
FRONTPANEL
1. Wind Speed Display
2. Wind Speed Units Indicator
3. Alarm Status Indicators
4. Maximum Wind Speed or Relative Wind Direction Display
5. Relative Wind Direction and Variability Display
6. Brightness (operate mode), ENTER (setup mode)
7. MAX RESET (operate mode), SELECT (setup mode)
BACK PANEL
1. Power input (12-30 VDC) AC adapter supplied
2. Sensor or 4-20 mA inputs
3. Earth ground connection
4. RS-485/NMEA serial connections
5. 0-5 VDC calibrated outputs
6. Alarm relay connections (normally open)
7. Input selector switch
YOUNG
WIND TRACKER

Page 2
MOUNTING AND START-UP
1. Selectlocationfordisplay.Alocationoutofdirectsunlightprovides
best visibility.
TheWindTracker may be mounted from a bulkhead or installed in
a flush panel by removing the mounting bracket. Panel cutout
dimensions are given in the specifications. An optional rack
mounting panel (Model WS-06280) and protective enclosure
(Model WS-06260) are available from your supplier.
2. Connect cables to terminals. Refer to diagrams on page 5.
Selector switch (item 7 on back panel illustration) should be
DOWN for normal sensor inputs, UP for 4-20 mA or Wind
Monitor-SE signals.
3. Connect GND terminal to suitable earth ground.
4. Insert power supply plug into power jack, plug into standard AC
wall outlet.
The Wind Tracker may also be powered from ships batteries. A
coaxial power plug (2.1mm) must be used. Center is positive.
5. The Wind Tracker will display a software version number for
approximately 4 seconds. It then begins to display wind informa-
tion. The following information is displayed:
• Wind Speed
• Wind Speed Units
• Maximum Wind Speed or Direction degrees
• Relative Wind Direction (single orange indicator)
• Direction Variability (green indicators)
• WS, WD Alarm Status Indicators (if selected)
6. Observe the unit for a few minutes to verify that it is operating
properly.Ifyouwishtochangesettings (ie: wind speed units). See
the following section.
CHANGING SETTINGS
The Wind Tracker has a setup mode that allows you to easily change
sensor type, wind speed units, alarm settings, and other functions.
Press and hold ENTER and SELECT keys (about 5 seconds). The
display will briefly flash “SET UP”, then begin the SETUP sequence.
Change settings with the SELECT key. Press the ENTER key to save
a setting and move to the next step. Abbreviations in the left and right
display windows identify each function and the available selections.
DISPLAY SETUP FUNCTION
LEFT RIGHT Input/Sensor Type
InP LDi Line Driver 4-20 mA input
03 Wind Sentry
04 Wind Monitor-Jr
05 Wind Monitor, Wind Monitor-MA
SEr Serial input from Wind Monitor-SE or main display
If SEr is selected, wind speed units and NMEA
output rate selections do not appear.
Wind Speed Units
SPd unt PressSELECTtochangeunits,ENTERto
proceed.
NMEA Output Rate
OUT FST 16 sentences sent per second
SLO 1 sentence sent per second
Display
dSP SPd Displays MAXIMUM wind speed in right display.
dir Displays WIND DIRECTION degrees
(1° resolution) in right display.
Wind Direction Alarm
ALr no WD alarm not used.
YES WD alarm activated.
If no is selected, the following 2 steps do not
appear.
ALr dir Press SELECT to position alarm sector.
Press ENTER.
ALr SPn Press SELECT to set size (span) of alarm
sector.
Wind Speed Alarm
ALr no WS alarm not used.
YES WS alarm activated.
If no is selected, the following step does not
appear.
ALr 000 WS alarm set point. Press SELECT to
change digits. ENTER to save.
If no alarm is selected, the following 2 steps do not
appear.
Alarm Delay Time
dLY 030 Set alarm delay time in seconds (0-999).
Sound
Snd no No sound with alarm.
YES Audible beeper will sound with alarm.
Test Functions
tSt no Skip test functions.
YES For troubleshooting only. YES will initiate the
following tests.
If no is selected, the unit will return to normal
operation.
tSt Snd Press SELECT to sound beeper.
tSt dSP Press SELECT to illuminate all display seg-
ments.
tSt ALr Press SELECT to close alarm relays.
CAL 0.00 PressSELECTtoalternatebetween0.00Voutand
5.00 Vout at terminals. Use to calibrate external
devices (recorders, etc..)

Page 3
ADDITIONALINFORMATION
ALARMS
Wind speed and wind direction alarm functions are accessed in the
SETUPsequence.Eitherorbothalarmsmaybeused.Whenactivated,
alarmsareindicated onthefrontpanel.Whenanalarmconditionexists,
theindicatorwillblinkandtheassociatedrelaycontactwillcloseandthe
beeper will sound if selected in SETUP. When a delay time is set, the
indicator will not report an alarm condition until it has existed for one
complete delay period. Alarm activity will cease when conditions are
outside the alarm range for one complete delay period. For a "latching"
alarm effect, use the Wind Tracker alarm contacts to activate an
external latching-type relay.
BRIGHTNESS
Adjust display brightness by holding the BRIGHT key.
MAXIMUM / WIND DIRECTION DIGITAL DISPLAY
The right display window can show either MAXIMUM WIND SPEED or
NumericalWINDDIRECTION.Thisselectionismadeinthesetupmode
under Display (dSP).
NMEA OUTPUT
The Wind Tracker features NMEA serial output from the RS-485
terminals. These terminals can be used to operate remote displays or
connect to other NMEA compatible devices. The NMEA output sen-
tence is sent 16 times per second (Fast) or once per second (Slow)
depending on the NMEA Output (OUT) setting in SETUP. For best
remote display, use the Fast setting.
REMOTE DISPLAYS
The Wind Tracker can be used as a remote display by selecting "InP
SEr"duringSETUP.Remotedisplaysareconnectedtothemaindisplay
using the RS-485 terminals. NMEA Serial Protocol is used to operate
remote displays. Up to 16 remote displays can be connected to one
main display. Use the serial input when connecting to a Model 09101
Wind Monitor-SE sensor. See wiring diagram.
VOLTAGE OUTPUTS
The Wind Tracker offers calibrated voltage outputs for both wind speed
and wind direction. This feature allows the use of recorders and other
devices. Full scale voltage for each channel is 5.00 VDC.
4-20mA INPUTS
The Wind Tracker accepts 4-20 mA (Line Driver) inputs. Line Driver
circuitmust provide0-50 M/SWindSpeed scaling("M" suffix). Connect
cableas indicatedonpage 4.Slideswitch onbackmust be UPat power
upforcorrect4-20mAoperation.SelectLDIasinputinSETUP. 24VDC
power is required for line driver applications.
ERROR MESSAGES
The Wind Tracker detects and indicates two errors. Once corrected,
the error indication disappears.
DISPLAY
LDi Err 4-20 mA (line driver) signal. Signal is missing or
outside of acceptable range. Verify proper
switch position or signal.
SEr Err Unit is set to receive RS-485 NMEA serial
signal, but no serial data is coming in. Verify that
NMEA source is operating. Check cables for
proper connection.
WARRANTY
The Wind Tracker is warranted to be free of defects in materials and
constructionfor a period of12months from date ofpurchase.Coverage
is limited to repair or replacement of defective unit.
SPECIFICATIONS
Size: 144 mm (5.65 in) x 144 mm (5.65 in) x 36 mm (1.4 in)
Panel Cutout: 138 mm (5.43 in) x 138 mm (5.43 in)
Compatible Sensors:
Wind Monitor-SE
Wind Monitor
Wind Monitor-MA
Wind Monitor-JR
Wind Sentry
Other Inputs:
4-20 mA
NMEA Serial Input/Output
$WIMWV,ddd,R,sss,u,A[CR][LF]
where:
ddd wind direction in degrees
sss wind speed (ss.s for m/s)
u units (N = knots, K = kilometers/hour,
M = meters/second, S = miles/hour)
Accuracy: ±0.6% F.S.
Display Resolution:
Wind Direction: 10° circular pattern (36 points)
1° w/ dSP dIr selected
Wind Speed &
Maximum: 1 Knot, 1 MPH, 1 KM/H, 0.1 M/S
Voltage Outputs:
Wind Direction Range:
0-5 VDC 0-360°
Wind Speed Range: (dependent on units selected)
0-5 VDC 0-100 Knots
0-100 MPH
0-200 KM/H
0-50 M/S
Alarm Relays: Non-latching
Normally Open contacts for WS and WD.
Contact rating 5A resistive,
2A inductive @ 24 VAC, 30 VDC.
Input Power: 12-30 VDC, 4.5 W
Weight: 1.0 lb (.45 kg) without AC adapter

Page 4
CE COMPLIANCE
This product has been tested and shown to comply with European CE
requirements for the EMC Directive. Please note that shielded cable
must be used.
Declaration of Conformity
Application of Council Directives:
89/336/EEC
Standards to which Conformity is Declared:
EN 50081-1
EN 55022 (CISPR 22 class A)
EN 50082-1 (IEC 801-2, 3, 4)
Manufacturer's Name and Address:
R. M. Young Company
Traverse City, MI, 49686, USA
Importer's Name and Address:
See Shipper or Invoice
Type of Equipment:
Meteorological Instruments
Model Number / Year of Manufacture:
06206/1996
I, the undersigned, hereby declare that the equipment
specified conforms to the above Directives and Standards.
Date / Place:
Traverse City, Michigan, USA February 19, 1996
David Poinsett
R & D Manager, R. M. Young Company

Page 5

Page 6
Table of contents
Popular Marine Equipment manuals by other brands

Bodet
Bodet Harmonys 907710 Installation and operating instructions

Oceanic
Oceanic Data Mask operating manual

Parker
Parker Sea Recovery ULTROClear Series Installation operation & maintenance

Simrad
Simrad SimNet Installation & use

Simrad
Simrad CS90 quick start guide

Volvo Penta
Volvo Penta B7 owner's manual

Fusion
Fusion Apollo MS-RA670 owner's manual

Apollo
Apollo TAS2 SAR BCD User instruction manual

Pfannenberg
Pfannenberg DS-SIL series Instruction Manual/Safety Manual

ESP
ESP MAGDUO MAGDUOSRSQ Installation and maintenance instructions

Lopolight
Lopolight 400-1 Series installation guide

Boss Audio Systems
Boss Audio Systems MR1308UAB user manual